| 1 | Wiring for light point / Fan point/ Exhaust Fan ponit / Call bell point with 1.5mm2 PVC insulated copper conductor single core cable in pvc casing and capping with piano type switch, phenolic laminated sheet suitable size M.S. Box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc. as reqd. |
| 2 | 3. Group C |
| 3 | Wiring for circuit / sub- main wiring along with earth wire with ( the following sizes of ) PVC insulated copper conductor single core cable in PVC casing and capping etc as reqd. |
| 4 | 2. 2x2.5mm2 + 1x2.5mm2 earth wire |
| 5 | 3. 2x4mm2 + 1x4mm2 earth wire |
| 6 | 4. 2x6mm2 + 1x6mm2 earth wire |
| 7 | Fixing Items |
| 8 | S/F PVC box of size 101mmx178mm (Nominal size)/(4''x7'')PVC board on surface including P/F 3 pin 5/6 amp socket outlet and 5/6 amp piano type switch connection etc as reqd. |
| 9 | S/F PVC box of size 152mmx203mm (Nominal or size)/(6''x8'')PVC board on surface including P/F 6 pin 15/16 amp socket outlet and 15/16 amp piano type switch connection etc as reqd. |
| 10 | 76.2mmX76.2mm conical round plate |
| 11 | S/Fbrass batten /angle holder i/c conection etc as reqd. |
| 12 | S/F 3 pin 5 amp ceiling rose on the existing junction box /wooden block i/c connection etc as reqd |
| 13 | S/F 8W CFL lamp. |
| 14 | S/F 20W CFL lamp. |
| 15 | Supplying & fixing stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc as reqd. |
| 16 | S/F 305mm sweep exhaust fan complete with all accessories i/c connection etc as reqd. |
| 17 | S/F 48'' Sweep (1200mm) A.C ceilling fan complete with down rod canopy, 3 (three) blades but without regulator etc as reqd.( Make Bajaj/Usha or simillar) |
| 18 | S/F ( following way) single/ double pole and neutral , sheet steel MCB distribution board, 240 V on surface/ recessed complete with tinned copper bus bar neutral bus bar , earth bar , din bar, detachable gland plate , interconnection ,phosphatized and powder painted including earthing etc. as reqd. ( but without MCB/RCCB/Isolator). |
| 19 | 3. 8 way single door |
| 20 | Supplying and fixing 5 amp to 32amp rating 230 V 'B' series MCB for lighting and other load of ( following poles ) in the existing MCB DB complete with connection testing and commissioning etc as reqd. |
| 21 | 1. Single pole |
| 22 | S/F( following rating) double pole 240v isolator in the existing MCB DB complete with connection ,testing and commissioning as reqd. |
| 23 | 1. 40 amp Please Enable Macros to View BoQ information |