| 1 | Surface dressing of the ground including removingvegetation and in-equalities not exceeding 15cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kind of soil. |
| 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 3 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 4 | Finishing walls with acrylic smooth exterior paint ofrequired shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 5 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 6 | Finishing with Epoxy paint ( two or more coats) ofapproved brand and manufacture at all locationsprepared and applied as per manufacturer's specification including appropriate priming coat, preparation of surface etc. complete [Payment shall be made after submission of Test Certificate issued by the Manufacturer]. On steel work |
| 7 | Repairs to plaster of thickness 12 mm to 20 mm inpatches of area 2.5 sqm and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground with all leads and lifts including finishing even and smooth and curing complete as per direction of the Engineer in charge: With cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 8 | 12 mm cement plaster of mix cement mortar 1:4 (1 cement : 4 fine sand). |
| 9 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checkingof all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of aluminium composite panel material of approved thickness and specification. Thealuminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approvedlaboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till thehanding over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium compositepanel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings andas directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.\\" 16.25.1 Aluminium Composite Panels of 4mm total thickness with Top coil– 0.50mm AA3003 / AA3105 / AA5005 Grade manufactured as per IS-737 1986, FR Grade ClassB1 with 3mm Mineral Core with minimum 70-72%Inorganic content (Aluminium Hydroxide and Magnesium Hydroxide) 28-30% Organic content (LDPE) conforming to ASTM E-119-16,18 and EN 13501-1, class B1,and Bottom coil– 0.50mm AA3003 / AA3105 / AA5005 Grade, manufactured as per IS-737 1986 with minimum 25 microns lead free PVDF Coating conforming to AAMA2605 on top coil and Service coating on Back Coil (4- 6 microns) having minimum panel weight of 7.5Kg/m2 |
| 10 | Providing and fixing Precast chequered cement concrete tiles18mm thick, laid in footpath & courtyard, on 20 mm thick bedof cement mortar 1:4(1 cement :4 fine sand) jointed with neat cement slurry including rubbing and cleaning etc. all complete as per direction of Engineer-in-charge.In dark shade using ordinary cement |
| 11 | Providing and fixing on wall face unplasticisedRigid PVC rain water pipes (working pressure 4kg/cm2) conforming to IS : 13592 Type A includingjointing with seal ring conforming to IS : 5382leaving 10 mm gap for thermal expansion etc.complete as per direction of Engineer-in-charge : Single socketed pipe - 110 mm OD |
| 12 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-A including jointing withseal ring conforming to IS : 5382 leaving10mmgap for thermal expansionetc. complete as per direction of Engineer-in-charge : |
| 13 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for nplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-A including jointing with seal ring conforming to IS : 5382 leaving10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge : Bend 87.5° 110 mm. |
| 14 | Providing and fixing 25mm x 1.40 mm clips made out of aluminium strip of approved design to unplasticised PVC rain water pipes by means of Plastic Wall Plugs fitted in the brick work /R.C.C work by drilling with the help of mechaine and screwed with M.S. screws of required length and making good the wall etc. complete as per direction of Engineer-in-charge. 110 mm. |
| 15 | Supply & installation of pre-painted Galvalume sheets for roofing/ cladding (size, shape and pitch of corrugation as approved by Engineer-in-charge) in 550mpa steel grade, made out of Cold Rolled Steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to ASTM A792/A792M and AS1397, Alloy coating AZ150/AZ70, colour coated with high quality Polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required and as per direction of Engineer-in-charge.0.40 mm thickness. |
| 16 | Providing and fitting of 2 nos Glow sign board (Bangali / English) with AMC Logo as per direction of the Engineer In Charge. Please Enable Macros to View BoQ information |