| 1 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. |
| 2 | Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. |
| 3 | Providing and Laying in position cement concrete including curing,compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. |
| 4 | M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 5 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 6 | Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 7 | P & F 1st quality Heavy Duty Vitrified Double Charged tileson floor, skirting and steps etc.in different sizes (thicknessminimum 10mm) with water absortion less than or equal0.08% and conforming to IS 15622 of approved make in allcolour and shade, laid with 20 mm thick CM 1: 4 includinggrounting the joints with white cement and matching pigmentetc complete. |
| 8 | size 600 mm X 600mm |
| 9 | Providing and Applying ACRYLIC emulsion polymerwaterproofing chemical coating, on over roof on over roofslabs/terrace/balconies/parapet wall etc.with followingmethod/specification:Paint the surface with regular paint brush so as to obtainapproximately 0.3mm thickness coating. apply the 2nd coatnext day at right angles to the 1st coat so that total thickness ofthe coating should be approximately 0.6mm coverage by usingabove formulation will be 40 ft2/ litre of chemical. paintedsurface does not require any external water curing sincechemical will hold sufficient water for curing.After the primercoat Apply 2 coats of modified acrylic emulsion polymerwater proofing compound having solar heat reductionproperties coating @ 0.330 KG/SQM on the surface of theinterval of 3-4 hours. Undulation on the surface is repairbefore the waterproofing work. |
| 10 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). For toilet block |
| 11 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : |
| 12 | 20mm thick |
| 13 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 14 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete |
| 15 | New Plastered Surface (three or more coats), |
| 16 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: |
| 17 | Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 18 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision |
| 19 | New Work |
| 20 | Providing & making artistic/heritage painting with the using apex ultima or equvalent exterior paint having anti algal and dust pick up resistence without finish as per direction of Engineer incharge on wall faces/panels etc. with approved colour in following pattems including painting base works of required paint in approved quality/brand.The painting shall be based on themes related to flora & fauna like creepers flower pots, animals, birds & natural figures. As the work shall be at the level of similar to enclosed drawing \\"C\\" |
| 21 | P & F European type white glazed vitreous china 1st quality Double syphonic W.C (IS :2556 Mark) with P or S trap including cutting and making good the wall and floor [ In Hall ] |
| 22 | P & F Bib Cock (IS : 8931 Mark), Superior quality ofapproved make: |
| 23 | C.P. Brass bib cock,15mm nominal bore. |
| 24 | P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook ofapproved make and heavy as per direction of Enginner-in-Charge |
| 25 | P & F water closet Seat Covers with brass hinges complete : |
| 26 | Solid PVC (IS 2548 marked) grade-I Black for EWC. |
| 27 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : |
| 28 | Size 610 mm x 510 mm |
| 29 | P & F 15 mm. Dia Connection Pipe of approved quality/make |
| 30 | PVC pipe with C.P. Brass nuts upto length, 450mm |
| 31 | P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: |
| 32 | PVC with PVC bend and superior internal fittings as per IS : 7231 . |
| 33 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. |
| 34 | C.P. Inlet connection 15mm.Brass (IS : 8931 marked) |
| 35 | P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete : |
| 36 | P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete : |
| 37 | P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: |
| 38 | 500 (-do-) |
| 39 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) |
| 40 | 20mm nominal size |
| 41 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. |
| 42 | PVC 110MM pipe Please Enable Macros to View BoQ information |