| 1 | Engagement of Excavator (JCB) for Land development works including cutting of wild trees, leveling, dressing, scraping of existing road surface, dismantling of brick drain etc. as per direction of EIC. |
| 2 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation. |
| 3 | Labour for lowering and stacking after dismantling in parts R.S. joists, channels, angles, tees, plates etc. complete as directed. From 1st floor level. |
| 4 | Engagement of hydra for shifting of M.S structural material as directed by EIC within the plant premises. |
| 5 | Loading in to trucks at the lifting point, unloading at destination, stacking properly in go downs or yard etc. as directed including carriage by head load up to a lead of 50.00 m at each of the two points. |
| 6 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. |
| 7 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. a) Pakur Variety. |
| 8 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal siz ) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety. |
| 9 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in ground floor (i) Tor steel/Mild Steel III. OTHER MANUFACTURERS NOT SPECIFIED. |
| 10 | Hire and labour charges for shuttering with centering and necessary staging up to 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (up to roof of ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation. |
| 11 | Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed.(i) 16 mm dia. bolt (a) 300 mm long. |
| 12 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in-charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rates includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental charges such as electricity charges, labour insurance charges etc. II) For Structural Works in Roof Trusses etc. using joists, channels and angles of specified section weighing less than 22.5 kg/ m. |
| 13 | Removing loose scales blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint. |
| 14 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 15 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface: With super gloss (hi-gloss) - iv) Two coats (with any shade except white). |
| 16 | Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wall after unscrewing bolts, nuts, screws etc. and stacking the material at site as directed. |
| 17 | Supplying, fitting & fixing Zn-Al alloy (55% AI & 45% Zn) coating of 150 grams per sq. meter (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapezoidal profile of approved make (excluding the supporting frame 16 work) fitted and fixed with 55 mm & 25 mm self-tapping screw, EPDM Washer 16 mm dia. & 3 mm thick As per etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). (i) In Roof:-a) With 0.5 mm thick sheet. |
| 18 | Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc. complete.(225mm end lapping)(A) 300 mm lapping each way (a) With 0.60 mm sheet. Please Enable Macros to View BoQ information |