| 1 | WORK NAME |
| 2 | SITC of Amplifier + Digital Players 350+350 watts, 6 mic & 2 Aux input suitable for sbove speakers having following specification (1) suitable for AC 240 watt & 36V DC operation (2) Power output: 350 W RMS at 10 % THD/500WRMS Max. (3) input channels: Stereo Music Mode L/R 200mV/100k Line/ RIV/200k ohms, mic:6XMic 0.6 mV/4.7K ohms Aux: 2xAux100mV/470Kohms, (4) freq Pesp: 50-15000+3db (5) Tibe Controls: Bass+10db at 100Hz treble+10db at 10kHz (6) speaker output 4 ohms, 8 ohms, 70V & 100V For each zone (7) Digital players MP3 player with USB SD & MMC Card reader and remote control, (8) Din/wt: W510 x H185 x D470mm/ 40.0 kg.Make: Ahuja/ Focal Audio/ Philips/ ONIDA |
| 3 | Supply installation commission & testing of out door garden speaker having following specification (a) Diameter of Done 10 inch (b) Diameter of stand (pipe) in M.S. Inch (c) polyclone tweet-peerless (Holland) 1 inch (d) polypropylene woofer – Iwai (german) 6.5 inch (e) power handing 50 watt RMS (f) impedance 8 ohms nominal (g) sensitive 89 db/w/m (h) Frequency response 65Hz to 18KHz (i) Operation relativr humidity 99% (k) Body material Lexan polycarbonate with S.S. fitting (I) LMT 100v (m) Colour of speakers Dark green, Black, yellow & red (n) Colour of pipe as per requirement to much the speakers. Garden peaker are totally weather proof unbreakable & UV proof Each speaker will be mounted on 50mm dia MS pipe dully painted with PU paint marching colour of speaker having lenth 3 mtr. And suitably grouted in ground with C.C. 1:3:6 in round shape foundation Complete in all respect but without light.,MAKE: Ahuja/ Focal Audio/ Philips. |
| 4 | WORK NAME |
| 5 | Supply & Laying following size' B ' class , G.I. Pipe confirming to IS :1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for layingearth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in-charge. (Earth Excavationwill be Paid Extra)All as per pre approved by Engineer in-charge.For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 32mm dia |
| 6 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | P / L of Double wall corrugated HDPE pipe confirming to IS : 16205P-24, Stiffness Class 750 N, Externally corrugated and havingsmooth surface inside with HDPE Coupler, Elbow, Tee at requiredDepth below the ground for laying cable of following Nominal Outerdia. MFR Test report from NABL accrediated is to besubmitted.(Excavation of Earth & Back filling with compaction is tobe Paid Extra)All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR . 50 mm |
| 8 | Structural steel work riveted, bolted or welded in built up sections,trusses and framed work, including cutting, hoisting, fixing in positionand applying a priming coat of approved steel primer all complete: |
| 9 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10kA breaking capacity (B/ C/D tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC, minimum phase termination capacity of35sq.mm. , conductor line load reversibility , IP 20 contact protectionand fitted in existing distribution board/sheets, minimum electricaloperation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80A & above rating including making connections, testing etc. asrequired. OEM shall have submit NABL / CPRI / ERDA accrediatedlab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work referAnnexure 'A' attached with this BSR 6 A to 32 A rating |
| 10 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathedArrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductorconfirming to IS 8130 of purity >99.6 %, round / flat strip armouringof cables, Inner / outer sheath confirming to IS:5831 in existing RCC/ Hume / Stoneware / PVC pipe/ open duct/cable trench / Cabletray(with cable tie) including testing etc. as required of followingsize. OEM must have it's own in house NABL accrediatedLaboratory for testing procedure as per IS:10810.For additionaltechnical parameters of product / work refer Annexure 'A' attachedwith this BSR 4.0 Sq. mm 2 core |
| 11 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2 x 1.5 sq.mm |
| 12 | SITC of IP-42 and general construction confirming to IS:8623 : 1993,wall/ free standing floor mounted dust and vermin proofcompartmentalised cubical panel as specifications and Otherparameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) asbelow:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alleycompartments having concealed hinged type doors with key typelock with / without detachable extension type structure. Removable3 mm. thick sheet steel gland plates with appropriate size ofknockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Waterrinsing, Activation, derusting, pickling in acid bath, phosphatising &shall be subjected to nine tank process and then Powder coated withapproved shade of minimum 70 microns on both side of panel. Thepanel having PE foam/ Neoprene rubber gasket of not less than3mm thickness ,required hardware , concealed hinged door with keytype locking arrangement for equipment/switchgear earthed with 2.5sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shallbe rigidly supported and made out by flexible copper wires (up to 63amp ) and by solid bus bar (>63 amp ) . control wiring will be carriedout with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5sq.mm flexible copper wire only. All joints / interconnections ofcopper bus bar shall be dully tinned . Clearance between main busbar and risers / metal parts shall be at least 10 mm additional towidth of bus bar Bus bar is insulated by Heat Shrinkable sleeves .Earth and Neutral bus bar shall be half of the size of phase bus bar.( Cost of Bus bar / Flexible wire for Interconnection between Mainbusbar and Switchgear is to be Paid Extra )(d)Wiring between components within switchgear and Incoming /outgoing cable shall be done through the terminal block only. Directconnection shall not be permitted. Each terminal block shall be onepiece moulded, barrier type, 650 volt grade, complete with washers,heads, studs with two nuts and identification strips and shall haveadequate continuous current rating. For tap-offs, adjacent terminalswith shorting strips shall be used. 10% Spare terminal blocks shallbe provided. Wire identification on marking strip shall correspond tothe designation of the wiring diagrams. All wire terminals on theequipment shall also be marked with designation corresponding tothose of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatlybunched and closed in metering chamber, Wiring between terminalsof various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels,adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and Highvoltage Power frequency test (by applying a voltage of 2.5KV for oneminute) shall be measured between phases, between phase andneutral and between phase and earth. both before and after highvoltage power frequency test. The insulation resistance shall not beless than three megaohm. CT Secondary current injection test shallalso be carried out.(h) only outer surface area on all sides shall be measured & panel tobe fabricated only from CPRI approved fabricator only (CPRI Testcertificates to be submitted)All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , referAnnexure \\"A\\" attached with this BSR . |
| 13 | Providing & Fixing of thermoplastic Polycarbonate cable junctionboxes with IP66 rating of protection & knock out for cable entry/outof following sizes including clamps for holding the box, including costof DIN rail for MCB mounting, 10 Sqmm 4 pole connectors for cablesterminals, threaded cable glands made of polyamide material etc.complete in all respect. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work ,refer Annexure \\"A\\" attached with this BSR . 175mm X 150mm X100mm Please Enable Macros to View BoQ information |