| 1 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 2 | Providing corrugated G.S. sheet roofing including vertical /curved surface fixed with polymer coated J or L hooks, boltsand nuts 8 mm diameter with bitumen and G.I. limpetwashers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 0.63 mm thick with zinc coating not less than 275 gm/m |
| 3 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 4 | Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 901 to 2000 Sq.Cm : |
| 5 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg./Cm2 .) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia |
| 6 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:3.17.1 Coupler (socket) 110 MM DIA |
| 7 | 3.17.9 Bend 87 .5 110 MM DIA |
| 8 | Pipe Clip 110 MM DIA |
| 9 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar. |
| 10 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 11 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) |
| 12 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffoldingTwo or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect |
| 13 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade One or more coats on old work. |
| 14 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of basewith sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision New Work |
| 15 | Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , attop ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately).For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing offittings wherever required (lockes shall be paid for separately). |
| 16 | Powder coating aluminum ( minimum thickness of powdercoating 50 micron) |
| 17 | Extra for shutters of sliding aluminum windows |
| 18 | Providing and fixing glazing in aluminium door, window,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and thedirections of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.)With float glass panes of 5.0 mm thickness ( weight not lessthan 13.50 kg/sqm) |
| 19 | S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding. |
| 20 | Providing and fixing 12 mm thick prelaminated three layermedium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde syntheticresin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 21 | Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges Sand or other approved stone 50mm thick. |
| 22 | Plaster on new surface on walls in cement sand mortar 1:4including racking of joints etc. complete fine finish :12.2.2 20mm thick |
| 23 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, SillsCounters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Jalore (P-white / S-white/ Rosy Pink colour) |
| 24 | Above 3601 Cm2 Slabs |
| 25 | Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge Granite/Kota Stone Work (i) Full Edge moulding |
| 26 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 27 | Grading roof for water proofing treatment with waterproffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate 20 mm nominal size) |
| 28 | Providing and Applying ACRYLIC emulsion polymerwaterproofing chemical coating, on over roof on over roof slabs/terrace/balconies/parapet wall etc.with following method/specification: Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. paintedsurface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work. |
| 29 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design |
| 30 | Filling the gap upto 5 mm depth and 5 mm width in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineerin- charge complete. Please Enable Macros to View BoQ information |