| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 1mtr. |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:A)1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 3 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness)including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses,string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with.1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20mm nominal size) with 20% boulders. |
| 5 | Providing and laying cement concrete in retaining walls , return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks,anchors blocks, plain window sills, fillets etc upto floor V level, including cuing but excluding the cost of centring, suttering and fnishing with 1:3:6 ( 1 cement: 3coarse sand :6 graded stone aggregate 20mm nominal size) with 20% Boulders. |
| 6 | Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement.A)1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with A) 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level A) Cold twisted bars. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 10 | Foundations, footings, bases for columns |
| 11 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 12 | Columns, pillars, piers, abutments, posts and struts. |
| 13 | Suspended floors, roofs, landings, balconies and access platforms. |
| 14 | Edges of slabs and breaks in floors and walls. A) Under 20cm wide. |
| 15 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :A)Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 16 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 17 | Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs andsteps etc. |
| 18 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):A)Sal wood |
| 19 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).A)Second class deodar wood. |
| 20 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick A)Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked |
| 21 | Providing and fixing 35mm glazed shutters for doors, windows and clerestory windows using 4mm thick float panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Second class deodar wood. |
| 22 | Providing and fixing wooden moulded beading to door and window frames withiron screws, plugs and priming coat on unexposed surface etc. complete:A)2nd class teak wood 50 x 20 mm |
| 23 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.A)Fixed to openings / wooden frames with rawl plugs screws etc. |
| 24 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 25 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622 of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigments etc. complete.A)Size of tile 600x600 mm |
| 26 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades,in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cementand matching pigments etc. complete.Size of tile 600x600 mm |
| 27 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 28 | 12mm Cement plaster of mix: A)1 : 6 ( 1 cement : 6 fine sand) |
| 29 | 15mm Cement plaster on the rough side of single or half brick wall of mix: A)1 : 6 ( 1 cement : 6 coarse sand) |
| 30 | Distempering with 1st quality acrylic distemper (ready mixed)having VOC content less than 50 gms/litre,two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications |
| 31 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 32 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 33 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.A)Two or more coats on new work. |
| 34 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete :A)300x16 mm |
| 35 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :A)100x10 mm |
| 36 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.A) 125 mm |
| 37 | Providing and fixing aluminum hanging floor door stopper, ISI marked,anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :A) Single rubber stopper |
| 38 | Providing and fixing aluminum casement stays, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 39 | Supplying and fixing modular switches/sockets, deep lights including wiring, connections of electric points complete item as per necessory at site. (LMR) |
| 40 | Cement concrete flooring 1;2;4 (1 cement:2 coarse sand :4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. a) 50 mm thick with 20mm nominal size stone aggregate. |
| 41 | Providing and fixing white vitreous china laboratory sink with C.I.brackets, C.P. brass chain with rubber plug, 40mm C.P. brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete,including painting of fittings and brackets, cutting and making good the walls wherever required :A) Size 600x450x200 mm |
| 42 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipesA)110 mm diametre . |
| 43 | Providing and fixing on wall face un-plasticized - PVC mouldedfittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Bend 87.5° |
| 44 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.2mm thick. |
| 45 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.A)Using flats 30x6mm for diagonal braces and central cross piece. |
| 46 | Providing and laying in position flow trap including all fittings ,complete job.(LMR) |
| 47 | Carriage of the following materials by Mechanical Transport and head load from source to site of work incl. loading, unloading and stacking complete :- |
| 48 | Sand for an average lead of 50 Km. |
| 49 | Stone aggregate below 40mm nominal size for an average lead of 50 Km. |
| 50 | Stone aggregate 40mm nominal size and above for an average lead of 50 Km. |
| 51 | Bricks for an average lead of 120 Km. |
| 52 | Stone/boulder for an average lead of 1 Km. Please Enable Macros to View BoQ information |