| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 1mtr. All kind of Soil. |
| 2 | Ordinary Rock. |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:A)1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering,shuttering, finishing and reinforcement. All work upto plinth level.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:A)1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 6 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :A)Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 7 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 8 | Providing and fixing pressed steel door frames conforming to IS: 4351 , manufactured from commercial mild steel sheet of 1.60mm thickness,including hinges jamb, lock jamb, bead and if required angle threshold ofmild steel angle of section 50x25mm, or base ties of 1.60mm pressed, mild steel welded or rigidly fixed together by mechanical means, including M.S pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B A) Fixing with adjustable lugs with split end tail to each jamb |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement withA) 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level A) Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 12 | Foundations, footings, bases for columns |
| 13 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 14 | Suspended floors, roofs, landings, balconies and access platforms. |
| 15 | Edges of slabs and breaks in floors and walls. A) Under 20cm wide. |
| 16 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 17 | 12mm Cement plaster of mix: A)1 : 6 ( 1 cement : 6 fine sand) |
| 18 | 15mm Cement plaster on the rough side of single or half brick wall of mix: A)1 : 6 ( 1 cement : 6 coarse sand) |
| 19 | Cement concrete flooring 1;2;4 (1 cement:2 coarse sand :4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. a) 50 mm thick with 20mm nominal size stone aggregate. |
| 20 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).A)Second class deodar wood. |
| 21 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick A)Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked |
| 22 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.A)Second class Kail wood |
| 23 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : :A)250X16mm |
| 24 | 200x10 mm |
| 25 | 100x10 mm |
| 26 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm |
| 27 | 100 mm |
| 28 | Providing and fixing aluminum hanging floor door stopper, ISI marked,anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :A) Single rubber stopper |
| 29 | Providing and fixing aluminum casement stays, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 30 | Distempering with 1st quality acrylic distemper (ready mixed)havingVOC content less than 50 gms/litre,two or more coats on new work of approved manufacturer, of required shade and colour complete as permanufacturer’s specifications |
| 31 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 32 | Applying priming coat:A) With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 33 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.A)Two or more coats on new work |
| 34 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 35 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 36 | Providing and fixing electric points complete in all respects as necessory as site.(LMR) |
| 37 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes. 110 mm diametre. |
| 38 | Providing and fixing M.S. grills of required pattern in frames of windows etc.with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 39 | Carriage of the following materials by Mechanical Transport and head load from source to site of work incl. loading, unloading and stacking complete :- |
| 40 | Sand for an average lead of 25 km. |
| 41 | Stone aggregate 40mm and above for an average lead of 25 km. |
| 42 | Stone aggregate below 40mm nominal size for an average lead of 25 km. |
| 43 | Bricks for an average lead of 60 km Please Enable Macros to View BoQ information |