| 1 | Earth work in excavation by Mechanical ( Hydrallic) means over areas exceeding 30 cms & upto 5 m in depth 1.5m in width as well as 10 sqm. On plan, disposal of excavated earth upto 1 m, disposed earth to be levelled & neatly dressed( all kinds of soils) |
| 2 | Providing & Laying of stone soling (dully hand packed)including watering dressing and ramming with all carriages, loading un-loading and stacking etc complete. |
| 3 | filling by avaliable excavated earth( excluding rock) in trenchs plinth sides of foundations in layers not exceeding 20 cm in depth consolidated each deposited by ramming and watering lead upto 50 mtr and lift 1.5 mtr |
| 4 | Providing & laying in position cement concrete of specified grade excld. The cost of centring and shuttering all work upto plinth level(1:4:8 coarse sand 40mm nominal size crushed stone agg.) |
| 5 | P/L in position specified grade of reinforced cement cencrete excld. The cost of centring, shuttering, finishing and reinforecement-All work upto plinth level. 1:1.5:3 graded stone agg. 20mm nominal size |
| 6 | RCC work in walls, incld. attchd pilasters, buttresses plinth & string courses, columns, pilars, abts, posts and sturts etc upto floor 5 level excld. Cost of cntring, shuttering, finishing and reinforcement 1:1.5:3 graded crshd stne agg. 20mm nominal size |
| 7 | Providing & laying in position cement concrete of specified grade excld. The cost of centring and shuttering all work upto plinth level M15(1:2:4)coarse sand 20mm nominal size crushed stone agg.) |
| 8 | Centring and shuttering of kit ply including proping, strutting & removal of the same.:Raft and plinth |
| 9 | Lintel band outer, steps, stair base slab, room beam, slab & stair beam |
| 10 | Brick work with FPS bricks of class designation 75 in superstructure in cement mortar 1:6 (1 cement, 6 coarse sand) |
| 11 | Extra for brick work from plinth level up to floor 1v leve qnty vide item 9=73.175 cum |
| 12 | Providing wood work in frames of doors, windows, clerestory windows & other frames, wrought framed & fixed in position imported Kail wood. |
| 13 | Providing & fixing panelled or panelled & glazed shutters for doors & windows and clerestory windows including ISImarked black enamelled M.S Butt hingeswith necessary screws excluding panelling imported kail wood 30mm thick |
| 14 | Providing & fixing panelling for shutters of doors of decorative prelaminated partical board with decorative laminationns on both sides. |
| 15 | Providing and Fixing wire guage shutters using galvanised M.S Wire guage of average width for aperture 1.4 mm in both direction with wire of dia .63 mm for Doors ,Windows and clerestory windows with ISI marked MS pressed but Hinges bright finished of requered size with necessary crews as per directions of engineer by (kiln seasoned and chemically treated Hollock wood) with 30 mm thickness |
| 16 | Providing & fixing of 25x3mm flat iron hold fast 40cm long including fixing to frameswith 10mm dia bolts nuts &wooden plugs and embedding in cement conc block 30x10x5cm 1:3:6mix (1cement:3coarse sand:6 graded st agg)20mm nominal size |
| 17 | 12mm Cement Plaster on the rough side of single or half brick wall of mix 1:6(1 cement:6 fine sand) |
| 18 | Cement Concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone agg) finished with a floating coat of neat cement incld. cement slurry but excld the cost of nosing of steps etc complete 50mm thick with 20mm n/s stone agg crushed |
| 19 | Extra for providing glass panes 3.5 mm thick )instead of ordinary glass panes13.75kg/sqm in doors windows and clerestory window shutters (Area of opening for glass panes excld portion inside shall be measured) |
| 20 | providing and applying 2 mm thick wall puty over plastered based surfaces two coats |
| 21 | Distempring with oil bound washable distemper of approved brand & manufacture to give an even shade New work (2 or more coats)over and incld. Priming coat with cement primer |
| 22 | Finishing walls with water proofing cement paint of approved brand and manufacture |
| 23 | Provision for fixing of MS ornamental grill including priming coat including welding complete job |
| 24 | Painting on G.S sheets with synthetic enamel paint of approved band and manufacture of required colour to give an even shade on New work (two or more coats) including a coat of approved steel primer. |
| 25 | Applying priming coat with ready mixed Pink or grey primer of approved brand and manufacture on WOOD work (hard or soft wood) |
| 26 | Painting with synthetic enamel paint of app. Brand & manufacture to give an even shade 2 or more coats on new work |
| 27 | Reinforcement for RCC work incld straightning, cutting, bending, placing in position & binding all complete (Thermo-mechanically treated bars) |
| 28 | Structural steel welded in built up sections trusses and framed work incld cutting hoisting fixing in positon and applying a priminng coat of approved steel primer all complete i/c fixing of sofiits and eaves boarding with 2mm thick MS sheets etc. |
| 29 | Providing and Fixing HRIB CCGI sheet roofing fixed with polymer coated J or L hooks bolts & nuts 8mm dia with bitumen & GI limpet washers upto( a pitch of 60 degree) excld cost of perlins, rafters & tresses 0.50mm thick with zinc coating not less than 275g/sqm( JIndal) incl. Ridge / valleys etc complete |
| 30 | Providing and Fixing Almunium hardware items :Concield Locks |
| 31 | Towerbolts 100 mm |
| 32 | Handles 150 mm |
| 33 | Handles 100 mm |
| 34 | Carriage of materails By Mech.Transport, from source to site of work:'Stone agg. for an avg lead of 25 km |
| 35 | Sand for an avg lead of 5 km |
| 36 | Bricks for an avg lead of 50 km |
| 37 | Providing & fixing wash basin with C.I/ M.S brackets 15mm C.P Brass piller taps 32mm C.P brass waste of standard pattern incld painting of fittings making good walls White viterous china flat back 630x450mm with a pair of 15mm C.P brass piller taps with stand |
| 38 | Providing and installation of 1HP electric Motor by crompton grieves with all fixtures electric wire 2mm structural steel strong Box with locking system complete job. |
| 39 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.WC Pan 580 mm |
| 40 | Providing & fixing stainless steel A ISI 304 w Kitchen Sink as per ISI 13983 with CI Brackets and stainless steel plug 40 mm including painting of fittings and brackets cutting and making good the walls wherever requered Kitchen sink with drain board 510x1040mm bowl depth 250 mm |
| 41 | Providing and fixing 50 litre Geyser of Approved brand and Manufacture (Havells) with all fixtures like angle value , conection pipe complete job |
| 42 | P/F first class quality ceramic Glazed floor tiles 300 x 300 mm make in colour excpt white, ivory, grey,fume red,brown laid on 20mm bed 1:4 complete Somany, Nitco,Kajaria |
| 43 | P/F first class quality ceramic glazed wall tiles of app make in all colour shades excpt begundy, bottle green black of any size in skirting risers of steps dados over 12mm bed of cement mortar 1:3 complete Somany, Nitco,Kajaria |
| 44 | Providing and laying vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to lS: 15622of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) including grouting the joints with white cement andmatching pigments etc. complete (60x60 cm) |
| 45 | Providing and laying of Precast cement concrete Rings 32'' in soak pit including cost of trenching and refilling Precast cement concrete cap. |
| 46 | Construction of brick masonry manhole chamber 1'-6\\" x 1'-6\\" x 1' deep i/c plaster / polishing with CI manhole cover with frame complete |
| 47 | Providing and fixing soil waste, vent pipes 100 and 75 mm with all fixtures like Trap,elbow,collar,socket including connection with septic and soakage etc complete job |
| 48 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in charge. Internal work Concealed fixing the pipe with clamps with all fittings like bends,Unions, sockets ,Tees,over lap,reducer,plin/Ft elbows,Ft.adopter,tanky niple,plugs and ball valve etc 25 mm dia.(Standard quality Q-therm or RAK therm. |
| 49 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in charge. Internal work Concealed fixing the pipe with clamps with all fittings like bends,Unions, sockets ,Tees,over lap,reducer,plin/Ft elbows,Ft.adopter,tanky niple,plugs and ball valve etc 32 mm dia.(Standard quality Q-therm or RAK therm. |
| 50 | Water storage tank PVC tripple layer of approved brand with all necessary fittings |
| 51 | Stain less steel heavy duty Bib cock long nose |
| 52 | Stain less steel heavy duty angle valve |
| 53 | Soap Case |
| 54 | PVC connections 24'' |
| 55 | Point wiring for switch controlled primary lighting points with 3x1.5 sq mm (P PVC insulated flexible stranded copper conductor wives of Polycab/ Havells/ Anchor Finoles make in recessed or surface conduiting system, incl. the cost of supplying and Fixing of metallic modular grid plate mounted flush, 240 volt 6A control switch housed in zinc chromate passivity Gl box with modular cover plate complete as per specifications and as required. The job includes providing and laying of circult wiring with 3x1.5 14 mm PVC insulated multistranded copper wire lald through PVC conduit from Di to First switch in sub circuit, excl. cost of conduit (C. job). Separate wiring for normal and nverter supply is to be provided and no extra circult wiring shall be paid what so ever reason or length. |
| 56 | Paint wiring for 10A socket out lets with 3x2.5 sq mm (P+N+E)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires of Polycab/ Havells/ Anchor/ Finoles make in recessed or surface conduiting system, incl. the cost of supplying and fixing of metallic modular grid plate mounted flush, 3 no. 240 volt 6A S pin socket out lets along with 3 no. 6A control switch housed in zinc chromate passivity Gil box with modular cover plate complete with internal connections, loop earthing wire of same size as per specifications and as required. The job includes providing and laying of circuit wiring with 3x2.5 sq mm PVC Insulated multistranded copper wire laid through PVC conduit from De to first switch in sub circuit, excl. cost of conduit. (C. job) Separate wiring for normal and Inverter supply is to be provided and no extra circuit wiring shall be paid what so ever reason or length. (Maximum two points shall be connected on one circult |
| 57 | Paint wiring for 10A socket out lets with 3x2.5 sq mm (P+N+E)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires of Polycab/ Havells/ Anchor/ Finoles make in recessed or surface conduiting system, incl. the cost of supplying and fixing of metallic modular grid plate mounted flush, 3 no. 240 volt 6A S pin socket out lets along with 3 no. 6A control switch housed in zinc chromate passivity Gil box with modular cover plate complete with internal connections, loop earthing wire of same size as per specifications and as required. The job includes providing and laying of circuit wiring with 3x2.5 sq mm PVC Insulated multistranded copper wire laid through PVC conduit from De to first switch in sub circuit, excl. cost of conduit. (C. job) Separate wiring for normal and Inverter supply is to be provided and no extra circuit wiring shall be paid what so ever reason or length. (Maximum two points shall be connected on one circult |
| 58 | Point wiring for 164 socket out lets with 3x4 sq mm (P+N+E)FRLS PVC insulated 05 660/1100volt grade ficxible stranded copper conductor wires of Polycab/ Havells/ Anchor Finolex make in recessed or surface conduiting system, incl. the cost of supplying and fixing of metallic modular grid plate mounted flush, 240 voit 16A 6 pin combined shuttered socket out lets along with 240volt 16A control switch housed in zinc chromate passivity Gl box with modular cover plate complete with internal connections loop earthing wire of same size as per specifications and as required. The job includes providing and laying of circuit wiring with 3x4 sq mm PVC insulated multistranded copper wire laid through PVC conduit from DB to first switch in sub circuit, excl. cast of conduit. (C. job) Separate wiring for normal and inverter supply is to be provided and no extra circuit wiring shall be paid what so ever reason or length (Maximum two points shall be connected on one circuit) |
| 59 | Supply, Installation, testing and commissioning of 10Watt LED bulb with holder and PVCO base block/ base plate. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of six months reckoned from the date ofSuccessful commissioning/ handing over of site to the intending department |
| 60 | Supply, Installation, testing and commissioning of1200 mm sweep ceiling fans of Havelb/04Crompton Greaves/Bajaj Usha (Sample to be got approved), incl. cost of celling rose (if required) and making of necessary connections |
| 61 | Supply, installation, testing and commissioning of 200 mm sweep shutter type exhaust01 no. Fans of Havells/Crompton Greaves/lajaj/ Usha (Sample to be got approved), inci, cost of cling rose and making of space in walis/ windows as per site and necessary Connections |
| 62 | Supply and fixing of modular blanking plates on modular switch plates, excluding switch plates |
| 63 | Wiring for circuits/ sulh mains along with earth wire in FRLS PVC insulated 660/1100volt grade fiesible stranded copper conductor wires of Polycab/ Havells/ Anchor/ Finolex make in recessed or surface conduiting system, excluding cost of conduits:2 x 2.5 sq.mm + 1x 2.5 sq. mm for inverter/solar sub main |
| 64 | 2 x 4 sq.mm + 1x 4 sq. mm for normal sub main |
| 65 | 2 x 6 sq.mm + 1 x 6 sq. mm for heating sub main |
| 66 | Supply and fixing of 25 mm dia. Medium grade PVC conduit including its allied 180mtr accessories like bends and concealed deeps, etc. for laying of wires, recessed in RCC slab walls including refacing of walls or fixed with necessary clips and rowel plugs complete |
| 67 | Supply and fixing of fan deep made of heavy gauge sheet In RCC slabs |
| 68 | Supply and fixing of 4 way Double door surface/ recess mounting, 240 V, SP&N MCB02 no. distribution board of sheet steel, dust protected, duly powder painted, Inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. |
| 69 | Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 1012 KA \\"C\\" curve MCB of Legrand/ Havells/ L&T suitable for Inductive load in the MCB distribution board complete with necessary connections |
| 70 | Supply, installation, testing and commissioning of 32A DP rating 240/415V, 10 KА \\"С\\" curve MCB of Legrand/ Havells/ L&T suitable for Inductive load in the MCB distribution board complete with necessary connections. |
| 71 | Supply, installation, testing and commissioning of 40A DP rating 240/415V, 10 КА \\"С\\"01 curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections |
| 72 | Supply, installation, testing and commissioning of 63A DP rating 240/415V, 10 KA \\"C\\"01 по curve MCB of Legrand/ Havells/L&T suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 73 | Supply and fixing of single pole blanking plates on existing MCB distribution boards. |
| 74 | Supply, laying, connecting and commissioning of 25 sq. mm 2 core PVC insulated fiat 30mtr Aluminum un armored LT cable for service line, incl. cost of required al. thimbles/lugs duly crimped. (Over head) |
| 75 | Earthing with Gi earth pipe 2.5 mtr. Long 40 mm dia. Including accessories and providing 01 no. masonry enclosure with cover plate having locking arrangements and watering pipe,trenching and filling with charcoal/coke and salt. |
| 76 | Providing and fixing of 25mmx5mm Gl strip on surface or in recess for extending the 20 mtr earthing from earth electrode to controlling panelin one rim to be laid through required dia, of PVC conduit. Please Enable Macros to View BoQ information |