| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 1mtr. |
| 2 | All kinds of soil. |
| 3 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.A) All Kind of soil. |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) with 20% boulder. |
| 6 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering,shuttering, finishing and reinforcement. All work upto plinth level.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :A)Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 8 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 9 | Structural steel work in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. A)Welded |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with A) 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level A) Cold twisted bars. |
| 12 | Structural steel work in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. A)Welded |
| 13 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.A)0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 14 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I.limpet and bitumen washers complete.A)0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 16 | Foundations, footings, bases for columns |
| 17 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 18 | Suspended floors, roofs, landings, balconies and access platforms. |
| 19 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 20 | 15mm Cement plaster on the rough side of single or half brick wall of mix: A)1 : 6 ( 1 cement : 6 coarse sand) |
| 21 | 12mm Cement plaster of mix: A)1 : 6 ( 1 cement : 6 fine sand) |
| 22 | Providing and fixing strips in joints of terrazzo/ cement concrete floors.A) Glass strips |
| 23 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc.complete A)50 mm thick with 20mm nominal size stone aggregate |
| 24 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).A)Second class deodar wood. |
| 25 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick A)Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked |
| 26 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.A)Second class Kail wood |
| 27 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 28 | A)200x10 mm |
| 29 | 100x10 mm |
| 30 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm |
| 31 | 100 mm |
| 32 | Providing and fixing aluminum hanging floor door stopper, ISI marked,anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :A) Single rubber stopper |
| 33 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete :250x16 mm |
| 34 | Distempering with 1st quality acrylic distemper (ready mixed)having VOC content less than 50 gms/litre,two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications |
| 35 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 36 | Applying priming coat: With ready mixed pink or grey primer of approved brandand manufacture on wood work (hard and soft wood) |
| 37 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.A)Two or more coats on new work. |
| 38 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mmnominal size well rammed and consolidated and grouted with fine sand including finishingthe top smooth and curing complete |
| 39 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 40 | Wiring for light point /fan point/exhaust fan point/call bell point/ with 1.5 sqm F.R.L.S pvc insulated copper conductor single core cable in surface/ressed medium glass pvc conduit, moduler switch, moduler plate, suitable g.gi box and earthing the point with 1.5 sq mm FRLS pvc insulated copper conductor single core cable etc. as required. (LMR) |
| 41 | Decorative painting which includes beautification on walls by way of alphabet writing, picture drawing of slogans,numerical, cartoon images as per BALA (building as learning and pattern) complete job. (LMR) |
| 42 | Carriage of the following materials by Mechanical Transport and head load from source to site of work incl. loading, unloading and stacking complete :- |
| 43 | Sand for an average lead of 20 Km by MT & 3.5 km by HL. |
| 44 | Stone aggregate below 40mm nominal size for an average lead of 20 Km by MT & 3.5 km by HL. |
| 45 | Stone aggregate 40mm nominal size & above for an average lead of20 Km by MT & 3.5 km by HL. |
| 46 | Bricks for an average lead of 90 Km by MT & 3.5 km by HL. |
| 47 | Stone/boulders for an average lead of 500 mtr Please Enable Macros to View BoQ information |