Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Main building (Civil works): Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil |
| 2 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 3 | Providing and laying in positon cement concrete of specified grade excluding the cost of centering and shutttering - All work up to plinth level: Providing and laying in positon cement concrete of specified grade excluding the cost of centering and shutttering - All work up to plinth level : 1:3:6 |
| 4 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 |
| 5 | Extra for providing and mixing water proofing material in cement concrete per 50kg work in doses by weight of cement as per manufacturer's specification. |
| 6 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering , shuttering, finishing and reinforcement - All works up to plinth level: 1:1.5:3 |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 |
| 9 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : Cement mortar 1:6 |
| 11 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 12 | Centering and shuttering including strutting, propping etc, and removal of form for: Foundation, footing, base of columns, pile cap, raft and mass concrtete works etc. |
| 13 | Centering and shuttering including strutting, propping etc, and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 14 | Centering and shuttering including strutting, propping etc, and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts |
| 15 | Centering and shuttering including strutting, propping etc, and removal of form for: Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 16 | Centering and shuttering including strutting, propping etc, and removal of form for: Staircase with sloping or stepped soffits including risers and stringers but excluding landing. |
| 17 | Edges of slabs and breaks in floors and walls. Under 20 cm wide. |
| 18 | 12 mm Cement plaster of mix. In cement mortar 1:4 |
| 19 | 15 mm Cement plaster on the rough side of single or half brick wall mix. In cement mortar 1:6 |
| 20 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigmentsetc. complete. Size of Tile 600x600 mm |
| 21 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and olishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red |
| 22 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 23 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching igments etc., complete. |
| 24 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 25 | Supplying and stacking at site. 53 mm to 22.4 mm size stone aggregate |
| 26 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hard packing, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . |
| 27 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 28 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 29 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge. Profile E. Fixing with adjustable lugs with split end tail to each jamb |
| 30 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 31 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. |
| 32 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.. 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. |
| 33 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of :(Note:- Butt hinges and necessary screws shall be paid separately). 12 mm thick one side Pre-laminated particle board (decorative lamination on one side and other sides balancing lamination) grade -1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT-1 conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and pre-laminated conforming to IS : 12823, Grade -1, Type II marked : |
| 34 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). |
| 35 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 36 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 37 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20kg/ 10sqm. |
| 38 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications. Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 39 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 40 | Supplying chemical emulsion in sealed containers including delivery asspecified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 41 | Diluting and injecting chemical emulsion for post constructional anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 42 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 43 | Providing and fixing aluminium sliding door bolts I.S.I. marked anodised ( anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete.with nuts and screws etc. complete : 300 x 16 mm |
| 44 | Providing and fixing aluminium tower bolts I.S.I. marked anodised ( anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete.with nuts and screws etc. complete : 250 x 10 mm |
| 45 | Providing and fixing aluminium handles I.S.I. marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete.with nuts and screws etc. complete : 125 mm |
| 46 | Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. 100 x 70 x 4 mm (ordinary type) |
| 47 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : 20 mm dia (heavy type) |
| 48 | FLAG HOISTING PADESTAL: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil |
| 49 | Providing and laying in positon cement concrete of specified grade excluding the cost of centering and shutttering - All work up to plinth level: 1:3:6 |
| 50 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 51 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth. Cement mortar 1:4 (1 cement : 4 coarse sand). |
| 52 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand). |
| 53 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and olishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.2 Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red |
| 54 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. stainless steel nuts& bolts complete , i.e. fixing the railing with necessary accessories & stainless steel dash gasteners, stainless steel bolts etc of required size , on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in charge.(For payment, only weight of stainless Steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts , fasteners etc will be considered) |
| 55 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.18.10.5 40 mm dia nominal bore (Flag Hoisting pipe) |
| 56 | Fire Extinguiser (4 nos.) |
| 57 | Supply, fitting & fixing of Verticale Blinds for Windows. |
| 58 | SANITARY WORKS: Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 59 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern |
| 60 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 61 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 62 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 63 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms |
| 64 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 65 | Providing and fixing toilet paper holder : C.P. brass |
| 66 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. |
| 67 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. In exposed surfaces or in trenches. 100 mm nominal dia pipes. |
| 68 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia. Sand cast iron S&S as per IS - 3989 |
| 69 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia. Sand cast iron S&S as per IS - 3989 |
| 70 | Providing and fixing plain bend of required degree. 100 mm dia. Sand cast iron S&S as per IS : 3989 |
| 71 | Providing and fixing soil, waste and vent pipes : 100 mm dia. Sand cast iron S&S pipe as per IS: 1729 |
| 72 | Providing and fixing PTMT grating of approved quality and colour.Circular type. 100 mm nominal dia |
| 73 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix, foundation concrete 1:5:10 , inside plastering 12 mm thick with cement mortar 1:3, finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455 x 610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 74 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 75 | WATER SUPPLY WORKS: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 50 mm nominal dia Pipes |
| 76 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 15 mm dia nominal bore |
| 77 | Providing and fixing C. P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore |
| 78 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 79 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore |
| 80 | Providing and fixing gun metal non- return valve of approved quality (screwed end). 50 mm nominal bore. Horizontal |
| 81 | Providing and fixing gun metal non- return valve of approved quality (screwed end). 50 mm nominal bore. Vertical |
| 82 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 83 | SEPTIC TANK: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil. |
| 84 | Providing and laying in positon cement concrete of specified grade excluding the cost of centering and shutttering - All work up to plinth level: 1:3:6 |
| 85 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering , shuttering, finishing and reinforcement - All works up to plinth level: 1:1.5:3 |
| 86 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : Cement mortar 1:4 |
| 87 | Brick work in cement mortar with 1st class brick including racking out joints and dewatering if necessary and curing complete as directed in sub structure upto plinth level. In prop 1:4 |
| 88 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 |
| 89 | Centering and shuttering including strutting, propping etc, and removal of form for: Foundations, footings, bases of columns etc. for mass concrete |
| 90 | 15 mm Cement plaster on the rough side of single or half brick wall mix 1:6. |
| 91 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18mm thick |
| 92 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 93 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 94 | Electrical Works: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 95 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 96 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 97 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 98 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 99 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 100 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm |
| 101 | Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured/Armour (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988, U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). 3 Core, 2XWY 2XFY. 2.5 Sq. mm.3 Core Copper arm. cable |
| 102 | Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured/Armour (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988, U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). 3 C x 2.5 Sq.mm End Termination (Lugs & double compression gland). |
| 103 | Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured/Armour (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988, U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). 3 Core, 2XWY 2XFY. 2.5 Sq. mm. 3 Core Submersible |
| 104 | Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). 3 & 1/2 Core A2XFY. 120.00 Sq. mm. 3 & 1/2 Core armoured U.G. cable |
| 105 | Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). 3 & 1/2 Core A2XFY. 70.00 Sq. mm.3 & 1/2 Core armoured U.G. cable |
| 106 | Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). 3 & 1/2 Core A2XFY. 3.5 C x 240 Sq.mm End Termination (Lugs & double compression gland) |
| 107 | Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). 3 & 1/2 Core A2XFY. 3.5 C x 120 Sq.mm End Termination (Lugs & double compression gland) |
| 108 | Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). 3 & 1/2 Core A2XFY. 3.5 C x 70 Sq.mm End Termination (Lugs & double compression gland) |
| 109 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 110 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 111 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch |
| 112 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet |
| 113 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet |
| 114 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet |
| 115 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 63 A industrial socket |
| 116 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 117 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 118 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100 mmX75 mm) |
| 119 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (100 mmX75 mm) |
| 120 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 Module |
| 121 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module |
| 122 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 123 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 124 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/ Isolator). 6 way (4 + 18), Double door |
| 125 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/ Isolator). 8 way (4 + 24), Double door |
| 126 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door |
| 127 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 128 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole |
| 129 | Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 40A |
| 130 | Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 63A |
| 131 | Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4P RCBO of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 30mA sensitivity 4P RCBO. (ABB, Schneider MG, legrand, Hager make). 25A |
| 132 | Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 133 | Earthing with Copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 134 | Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required. |
| 135 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm) |
| 136 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with G.I nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I nut bolt & spring washer spaced at 50 mm) |
| 137 | Supply, installation, Testing & Commissioning of Panel, as per technical specification and consultants drawings as per requirement and as directed by the consultant: Panel Tag: P-1 Main LT PANEL (always consult the Consultants SLD; the below given details are brief description): Incoming No 1: Each of the incoming feeder will consist of: 1 No. 400A FP MCCB 36KA, 1 Lot - Indicating Lamps, 1 Set - Digital Multimeter (V,I,F,KWH), 1 Lot -Control Fuse, SP MCB, Accessories as required. Bus Coupler-400A FP MCCB 36kA, Bus Bar-1 Set, 1 Set -400A TPN Alum Bus Bar of 65kA Short circuit rating for 1 Sec with heat shrunk colour coded PVC sleeve fitted using DMC/SMC mounts: Incoming No. 2: Each of the incoming feeder will consist of- 1 No.-250A FP MCCB 36KA, 1 Lot - Indicating Lamps, 1 Set - Digital Multimeter (V,I,F,KWH), 1 Lot -Control Fuse, SP MCB, Accessories as required. Bus Bar-1 Set Outgoings feeders as follows: All out going feeders will have, 1 Lot - Lamps For on/off/trip, Feeder Ratings are furnished below: 2 Nos. -100A 36kA FP MCCB , 5 Nos. -25A 10kA FP MCB, 1 No. -250A 36kA FP MCCB. |
| 138 | Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant: 80 Watt Highbay light |
| 139 | Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant: 7.5 Watt Cob |
| 140 | Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant: 4000 Lumen 6500K; Recessed LED Panel suitable grid or plain gysum ceiling of size 595x595mm |
| 141 | Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant: 3000 Lumen 6500K; Recessed LED Panel suitable grid or plain gysum ceiling of size 595x595mm |
| 142 | Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant: 2400 Lumen 6500K; Recessed LED Panel suitable grid or plain gysum ceiling of size 595x595mm |
| 143 | Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant: 1800 Lumen 6500K; Recessed LED Down Light |
| 144 | Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant: 1500 Lumen 6500K; Recessed LED Down Light |
| 145 | Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant: 1200 lumen 6500K; Recessed type LED Down Light |
| 146 | Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant: 800 lumen 6500K; Surfaced type LED Down Light |
| 147 | Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant: 3000 Lumen/3000K LED Street Light |
| 148 | Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant: 3500 Lumen / 3000K LED Post Top Lantern |
| 149 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 150 | Supplying of 450 mm sweep exhaust fan(metal body) in the existing suitable size of the above fan etc as reqd. |
| 151 | Supply, installing, testing and commissioning of wall mounted air cooled Five star rateing split air conditioning units with ingrated drain pump as described in specifications. The unit shall be complete with decorative type fan coil unit and external condensing unit, complete in all respects, inclusive of copper refrigerant piping, GI condensate drain piping, valves and insulation quoted price shall include cost of cooling thermostat, power wiring, control wiring and earthing. The unit capacities shall be as follows:Note : Fins and copper tubes of Air Cooled Condenser alongwith copper tubing / piping with all joints and U-Bends exposed to coastal areas corrosive atmosphere / aggressive ambient, shall be painted with special corrosion prevention coating either in factory or at site. 1.5 Ton Hi wall split Air Conditioning Unit with standard Static pressure |
| 152 | Supply, fitting and fixing of outdoor type Glow Sign Board made of M.S. Frame/ Aluminum frame, Galvinised Sheet & Acrylic Sheet as directed by the department including lettering, low energy conservation light, transportation and all accessiores complete. |
| 153 | Cost of meter with meter cabinet etc. (As per APDCL approved rate) |
| 154 | Load Security for 15 KW of load. |
| 155 | Supplying with installation, testing and commissioning of Aquaguard Water Filter - Model - Geneus DX. |
| 156 | Supplying with installation, testing and commissioning of Iron Remover for Water Filter. |
| 157 | Supplying with installation, testing and commissioning of HP Desktop Computer (All In One): Product SKU- HP 24-f0123in AIO PC, Processor- 9th Gen Core i5 9400T HC, Windows 10+, 4GB RAM, HDD- 1 TB + 256GB SSD, Graphics 2GB, Screen size- 23.48\\" FHD White |
| 158 | Supplying with installation, testing and commissioning of G-Series Printer: Model G-4010 MFP- WiFi & ADF Genuine CISS Printer with 4 Ink system/ up to A4 Borderless Printing/ Page Yield: |
| 159 | Supplying with installation, testing and commissioning of Scanner - EPSON make, Model - EPSON DS- 1630. |
| 160 | Brick Boundary wall: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m, as directed by Engineer-in-Charge. All kinds of soil |
| 161 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 |
| 162 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 |
| 163 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 |
| 164 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete |
| 165 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 166 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts |
| 167 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 168 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth. Cement mortar 1:4 |
| 169 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 |
| 170 | 15 mm cement plaster on the rough side of single or half brick wall of mix. 1:4 |
| 171 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 172 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, Gates, Grills and similar works. |
| 173 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. Water thinnable cement prime. |
| 174 | Finishing walls with Acrylic Smooth exterior paint of required shade. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 175 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
| 176 | MS Gate with 2 nos. RCC post & tie beam: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m, as directed by Engineer-in-Charge. All kinds of soil |
| 177 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 |
| 178 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 |
| 179 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 |
| 180 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete |
| 181 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 182 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts |
| 183 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 184 | 15 mm cement plaster on the rough side of single or half brick wall of mix. 1:4 |
| 185 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 186 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. Water thinnable cement prime |
| 187 | Finishing walls with Acrylic Smooth exterior paint of required shade. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 188 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, Gates and similar works. |
| 189 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
| 190 | Drain (Length 70 M): Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil. |
| 191 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 192 | Providing and laying in positon cement concrete of specified grade excluding the cost of centering and shutttering - All work up to plinth level: In Prop. 1;3:6 |
| 193 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering , shuttering, finishing and reinforcement - All works up to plinth level: 1:1.5:3 |
| 194 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in: Cement mortar 1:4 |
| 195 | Centering and shuttering including strutting, propping etc, and removal of form for: Foundations, footings, bases of columns etc. for mass concrete |
| 196 | 12 mm Cement plaster of mix. 1:6 |
| 197 | 15 mm Cement plaster on the rough side of single or half brick wall mix. 1:6 |
| 198 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 199 | Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge |
| 200 | Culvert (Length 7.60 M): Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil. |
| 201 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 202 | Providing and laying in positon cement concrete of specified grade excluding the cost of centering and shutttering - All work up to plinth level: In Prop. 1:3:6 |
| 203 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering , shuttering, finishing and reinforcement - All works up to plinth level: 1:1.5:3 |
| 204 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in: Cement mortar 1:4 |
| 205 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 |
| 206 | Centering and shuttering including strutting, propping etc, and removal of form for: Foundations, footings, bases of columns etc. for mass concrete |
| 207 | 12 mm Cement plaster of mix 1:6 |
| 208 | 15 mm Cement plaster on the rough side of single or half brick wall mix. 1:6 |
| 209 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 210 | Road: Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary soil. Manual Means. Without dewatering. In ordinary soil |
| 211 | Construction of Subgrade and Earthen Shoulders (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table (300-2) (a), ( Including cost of testing of materials at site and laboratory as directed by the deptt.). From Private Land . |
| 212 | Extra lead beyond initial lead of 3.00 Km |
| 213 | Compacting original ground supporting subgrade (Loosening of the ground upto a level of500 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of table 300-2 for subgrade construction.) |
| 214 | Granular Sub-base with Close Graded Material: Plant Mix Method (Construction of granular sub- base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density,complete as per cl. 401( Including cost of testing of materials at site and laboratory as directed by the deptt.). Using Grading-I material |
| 215 | Cost of haulage for Grading-I material excluding loading and unloading |
| 216 | Granular Sub-base with Close Graded Material: Plant Mix Method (Construction of granular sub- base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density,complete as per cl. 401( Including cost of testing of materials at site and laboratory as directed by the deptt.). Using Grading-II material |
| 217 | Cost of haulage for Grading-II material excluding loading and unloading |
| 218 | Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density (with an initial lead of 5.0 km.). By manual means, Grading-I, Using screening crushable type such as moorum or gravel |
| 219 | Cost of haulage for Grading-I material excluding loading and unloading |
| 220 | 100mm thick interlocking precast blocks having compressive strength of 50 N/sq.mm. |
| 221 | DEEP TUBE WELL (150 MM DIA WITH PVC CASING PIPE): Preparing of site for placement of drilling rig including excavation of mud pit, circulation drain, collection chamber etc. all complete as directed. |
| 222 | Movement of rig to drilling site including cost of POL all complete as directed. |
| 223 | Transportation of ancilary equipment, camp materials, welding set, rig accessories etc. including cost of POL all complete as directed.. Up to 100.00 Km |
| 224 | Transportation of all store materials including cost of POL all complete as directed. Up to 100.00 Km |
| 225 | Transportation of air compressior to the drilling site with all accessories including the cost of POL all complete as directed. Up to 100.00 Km |
| 226 | Construction of temporary accomodation and low cost sanitary facility for drilling staff all complete as directed. |
| 227 | Providing water suplly facilities at drilling all complete as directed. |
| 228 | Providing 300 mm dia PVC pipe for outer casing at boring well of Supreme/Prince make. |
| 229 | Drilling with drilling bit in over burden portion of soil formation including of soil sample at every 3m depth of wherever there is change of strata in sample box with distinguish mark up to depth of rock formation and withdrawing the drill bit for lowering as directed with 245mm/305mm dia drill bit. |
| 230 | Casing and sinking/lowering of MS pipe 200mm dia including cost of pipe and labour charges for cashing, welding the joints and sinking by drilling Rig in position all complete (Outer Casing MS pipe). |
| 231 | Casing and sinking/lowering of PVC pipe 115mm dia including cost of pipe and labour charges for cashing, jointing and sinking in position all complete (inner casing PVC pipe). |
| 232 | Casing and sinking/lowering of PVC filter 115mm dia including cost of filter and labour charges for cashing, jointing and sinking in position all complete (inner casing PVC filter). |
| 233 | Developing of the DTW with air compressor, make Kirloskar/Cumins all complete as directed. |
| 234 | Supplying, fitting, fixing MS clamp of size 15 mm thick and 150 mm width having projection of 300 mm and three holes of 20 mm dia for clamping the plates by 16 mm dia hexagonal bolts of length 75 mm and nuts on both sides encircling the column pipe including two coat of enamel paint over one priming coat of different dia all complete as directed and specified. 200 mm dia |
| 235 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge (Suction pipe). CPVC pipes. 40 mm nominal dia pipe |
| 236 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge (Delivery pipe). CPVC pipes. 40 mm nominal dia pipe |
| 237 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 238 | Supplying including installation, connection as approved by the Deptt., testing and commissioning of Submersible pump set 3 (Three Phase) (Varuna/ CRI suitable for 100 mm bore well and above), 5 HP, 50 Stage with MCB controlled Submersible motor pump set, Control panel with rope and submersible cable (6 mm), submersible clamp, etc. complete as directed and specified by the deptt. 5 HP, 50 Stage Submersible motor pump set including accessories complete. |
| 239 | Site Development: Banking excavated earth in layers not exc. 20 cm in depth, braking clods, watering, rolling each layer with 1/2 ton roller or wooden or steel rammers etc. lead upto 50 mtr. And lift upto 1.50 mtr. |
| 240 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hard packing, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . |
| 241 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 242 | Horticulture work: Providing and displaying of Seaforthia Palm having ht. 1.20 m. to 1.50 m. with 8-10 suckers, well developed, fresh and healthy lush green leaves from bottom to top in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 243 | Chinese palm |
| 244 | Fan palm |
| 245 | Providing and Displaying Ficus Starlight with fresh, healthy and attractive foliage 45 to 60 cm spread 75 to 90 cm ht., specimen bushy ,in 35 cm Cement Pot as per direction of the officer-in-charge. |
| 246 | Providing and Displaying Cyprus Golden 30 to 45 cm ht. well developed good Golden colour foliage, Conial Shape in 25 cm Earthen Pots as per direction of the officer-in-charge. |
| 247 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar. |
| 248 | Office Furniture & Fixture: ADCI`s TABLE: Model: HT 528: Main Table Size: 1800 W x 750 D x 750 H MM, Side Unit Size: 905 W x 440 D x 750 H MM as per specifications. Make: Featherlite. |
| 249 | Account, Ext. Officer & Asst. Cabin Table: Model: V-MT 1575: Size: 1500 W x 750 D x 750 H, Side Table: 1200 W x 450 D x 750 H as per specifications. Make: Featherlite. |
| 250 | Dias TABLE: MAIN TABLE SIZE: 2100 x 900 x 750 H with both side gromet hole as per specifications. Make: Featherlite. |
| 251 | STORAGE: Model: FSTO: Size: 900 W x 450 D x 2100 H as per specifications. Make: Featherlite. |
| 252 | Canteen Table: Model: Multi purpose Table: Size: 900 Dia x 750 H as per specifications. Make: Featherlite. |
| 253 | RECEPTION TABLE: Model: Reception 2A: Size: 2400 W x 750 D x 1050 H mm as per specifications. Make: Featherlite. |
| 254 | ADCI`s CHAIR : Model: Astro HB as per specifications. Make: Featherlite. |
| 255 | ADCI`s VISITOR`s CHAIR: Model: Contact Project VA as per specifications. Make: Featherlite. |
| 256 | Account, Ext Officer & Asst. Dias & Reception Chair: Model: Contact Project MB as per specifications. Make: Featherlite. |
| 257 | Account, Ext Officer & Asst Visitor Chair: Model: Magna VA as per specifications. Make: Featherlite. |
| 258 | SEMINAR CHAIR: MODEL: MAGNA WD as per specifications. Make: Featherlite. |
| 259 | Canteen Chair: Model: Tang as per specifications. Make: Featherlite. |
| 260 | SINGLE SEATER SOFA: Model: E007 1S as per specifications. Make: Featherlite. |
| 261 | TWO SEATER SOFA: Model: E007 2S as per specifications. Make: Featherlite. |
| 262 | Center Table Oval Shape: Size: 1050 L x 600 D x 450 H as per specifications. Make: Featherlite. |
| 263 | Foundation Stone Laying Ceramony |
| 264 | Inauguration Ceramony Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail