| 1 | 1. EXTENSION & RENOVATION OF EXISTING BUILDING : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 2 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete:16.12.1 With common burnt clay F.P.S. (non modular) brick of class designation 7.5 |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.2.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 20mm nominal size). |
| 4 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 7 | 5.9.4 Shelves (Cast in situ) |
| 8 | 5.9.5 Lintels beams plinth beams, girders, bressumers and cantilvers |
| 9 | 5.9.6 Columns, Pillars, Piers, abutments, posts and struts |
| 10 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 14 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 15 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources). |
| 16 | Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in foundations and plinth in :6.12.1 Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 17 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.1 Second class teak wood |
| 18 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of : (Note:- Butt hinges and necessary screws shall be paid separately)9.6.1 12 mm thick plain grade -1, medium density flat pressed three layer particle board FPT - I or graded wood particle board FPT- I, IS : 3087 marked, bonded with BWP type synthetic resin adhesive as per IS : 848 : |
| 19 | Providing and fixing aluminium work for doors windows ventilators and partition with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285 fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e. at top bottom and sides with required EPDM rubber/neoprene gasket etc. aluminium sections shall be smooth rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/penelling, C.P. brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, peneling and dash fasteners to be paid for separately):21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron). |
| 20 | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6mm thick clear float glass both side, having 12mm air gap including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealent) etc. as per specifications, drawings and direction of Egineer-in-charge complete. |
| 21 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.11.41A.1 Double charge vitrified tile polished finish of size of tile 600x600mm |
| 22 | 11.41.A Glazed vitrified tiles matt/antiskid finish of size of tile 600x600mm |
| 23 | 15mm cement plaster on the rough side of single or half brick wall of mix:132.1 1:4 (1 cement: 4 fine sand). |
| 24 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick |
| 25 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete:9.72.6 75x40x2.5mm (ordinary type) |
| 26 | Providing and fixing chromium plated brass handles with necessary screws etc. complete:9.92.1 125mm |
| 27 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :9.74.1 250x10 mm |
| 28 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws etc. complete. |
| 29 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.9.48.2 Fixed to openings/wooden frames with rawl plugs screws etc. |
| 30 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth complete. |
| 31 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 32 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 33 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :12.51.1 Ridges plain (500 - 600mm) |
| 34 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling of size 595x595mm of approved texture, design and paltems having NRC (Noise Reduction coeffcient) of 0.50 (minimum) as per IS 8225:1987 light reflectance of 85% (minimum).Non combustible as per BS:476 (part 4) fire performance as per BS:476 (part 6&7) humidity resistance of 100% thermal conductivity<0.043 W/m K as per ASTM 518:1991 in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 grams per sqm including both sides) comprising of main T runners of size 24x38mm of length 3000mm cross-T of size 24x32mm of length 1200mm and secondary intermediate cross T of size 24x32mm of length 600mm to form grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjusler of size 85x25x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plug at 450mm center to center and 40mm long dry wall S.S. screws. The work shall be carried out as per specification drawing and as per direction of the Engineer-in-charge.With 15mm thick regular edged light weight calcium silicate false ceiling tiles. |
| 35 | Providing and fixing in position wall panelling at all heights with integral densigied calcium silicate panels/tiles of szie 595 x595mm, having NRC (Nolse Reduction coefficient) of 0.50 (minimum) as per IS: 5225:1987, Light reflective of 85% (minimum). Non combustible as per BS:476 (part-4) fire performance as per BS:476 (part 6&7) humidity resistance of 100% thermal conductivity. |
| 36 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth complete. |
| 37 | Finishing with deluxe multi surface paint system for interiors and exteriors using primer asper manufacturers specifications: 13.48.1 Two or more coats applied on walls @ 1.25 lts/10 sqm over and including one coat of special primer applied @ 0.75 ltr/10 sqm |
| 38 | 2. FURNITURES & DIGITAL ITEMS :Wooden Book shelf |
| 39 | Wooden Conference Table |
| 40 | Study Chairs |
| 41 | Secretary Table |
| 42 | Executive Chair |
| 43 | Steel Almirah |
| 44 | 1.5 ton A.C. including 2m copper cable and compatible stabilizer |
| 45 | HP Laptop 15-fd03TU, Silver Intel Core 3 100U processor Windows 11 Home Single Language 39.6cm (15.6) diagonal FHD, anti-glare display Intel Graphics GB DDR5-5200 RAM 512 GB SSD Hard Drive |
| 46 | 3. INTERNAL ELECTRICAL WORKS :Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.1.10.1 Group A |
| 47 | 1.10.2 Group B |
| 48 | 1.10.3 Group C |
| 49 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth |
| 50 | 1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth |
| 51 | Supplying and fixing following modular switch/ socket on the existing switch box /cover including connections etc. as required.1.24.1 5/6 amps switch |
| 52 | 1.24.3 15/16 A switch |
| 53 | 1.24.4.3 pin 5/6 A Socket outlet |
| 54 | 1.24.5 6pin 15/16 A socket outlet |
| 55 | 1.24.8 Bell Push |
| 56 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 57 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1.27.2 3 Module (100mm x 75mm) |
| 58 | 1.27.5 8 Module (125mm x 125mm) |
| 59 | 1.27.6 12 Module (200mm x 150mm) |
| 60 | Supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required.1.28.2 3 Module |
| 61 | 1.28.5 8 Module |
| 62 | 1.28.6 12 Module |
| 63 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 64 | Supplying and fixing brass batten/angle holder including connections etc. as required. |
| 65 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).2.3.1 6 way, Double door |
| 66 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.10.1 Single Pole |
| 67 | Supplying and fixing following rating, double pole, 415V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.12.2 63A |
| 68 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 69 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required. |
| 70 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation sand cushioning, protective covering and refilling the trench etc. as required.7.1.1 Upto 35 sq.mm |
| 71 | Supplying with including fitting fixing of 18 Watt LED Tube Light etc. as directed by the Deptt. |
| 72 | Supplying with including fitting fixing of LED Bulb 9 Watt etc. as directed by the Deptt. |
| 73 | Supplying with including fitting fixing of Ceiling Fan etc. as directed by the Deptt. |
| 74 | Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminium conductor up to 10sq.mm, balance standard conductor, XLPE insulated, core laid up PVC tape inner sheathed, Armor (Aluminium wire for single core upto 70 sq.mm, balance aluminium strip, Galvanised wire for cable upto 2 x 10 sq.mm 4 x 6 sq.mm & balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 650/1100V grad as per IS 7908 (Part-I) 1988 armored U.G. cable as specified and directed by the deptt. (Havells RR or equivalent make as approved by this Deptt).25.00 sq.mm 4 core armoured cable Please Enable Macros to View BoQ information |