| 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 2 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 3 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 4 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet. |
| 5 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 6 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 7 | Extra for providing and fixing wind ties of 40x 6 mm flat iron section. |
| 8 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'S or 'L' hooks, bolts & nuts 8 mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafers, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified: 2 mm thick corrugated (2.5\\" 0r4.2\\" or 6\\") or step-down (2\\" or 3\\" or 6\\" ) as specified. |
| 9 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) |
| 10 | Providing flat iron brackets 50x3 mm size with necessary bolts, nuts and washers etc. for fixing G.S. sheets gutters with purlins. |
| 11 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete: 0.63 mm thick with zinc coating not less than 275 gm/m2. |
| 12 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick |
| 13 | Finishing walls with Acrylic Smooth exterior paint of required shade: Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface. |
| 14 | Finishing walls with water proofing cement paint of required shade: Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat. |
| 15 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work |
| 17 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 18 | 12 mm cement plaster of mix: 1:6(1 cement: 6 fine sand) |
| 19 | Providing and fixing ball bearing for rolling shutters. |
| 20 | Extra for providing mechanical device chain and crank operation for operating rolling shutters: Exceeding 10.00 sqm and upto 16.80 sqm in the area. |
| 21 | Dismantling PVC rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 150 mm dia pipe. |
| 22 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, as per instruction of EIC (i) Single socketed pipes (supreme or equivalent): 150 mm diameter |
| 23 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4(1 cement: 4 coarse sand) and making good the wall etc. complete. |
| 24 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. Bend 87.5° : 150 mm bend |
| 25 | Providing unskilled labour for cleaning of drain, shifting of drill bet, old GS sheet, mq, bq drilling pipe , moter parts within CMPDI campus etc in complete all respect. |
| 26 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 27 | Circuit/sub-main wiring in PVC conduit : Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable 1.1 kv grade in surface/recessed medium class PVC conduit as required. A. 2x1.5 sq.mm + 1.1.5 sq.mm earth wire. |
| 28 | B. 2x2.5 sq.mm + 1x2.5 sq.mm earth wire |
| 29 | C. 2x4 sq.mm + 1x4 sq.mm earth wire. |
| 30 | Supplying and fixing piano/flush type switch/socket on the existing switch box/cover including connections etc. as required : A. 5/6 amps switch |
| 31 | B. 15/16 amps switch |
| 32 | C. 3 pin 5/6 amps socket outlet |
| 33 | D. 6 pin 15/16 amps socket outlet |
| 34 | Supply and fixing 3 pin 5 A, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 35 | Supply and fixing 5A to 32 A rating 240/415V ,10 kA \\"C\\"- curve miniature circuit breaker suitable for inductive load for following pole in the existing MCB DBs complete with connections , testing , commissioning etc. as required. A. Single pole |
| 36 | B. Double pole |
| 37 | C. Triple Pole and Neutral |
| 38 | Supplying and fixing following ways surface / recess mounting vertical type 415 V TPN MCB MCB distribution board of sheet steel, dust protected ,duly powder painted inclusive of 200A tinned copper bus bar , common neutral link , earth bar , din bar for mounting MCBs (But without MCBs and incomer) as required (Note : Vertical type MCB , TPDB is normally used where 3 phase outlets are required. (But without MCB/RCCB/Isolator). A. 4 way (4 + 12) double door |
| 39 | B. 8 way (4 + 24) double door |
| 40 | Supply and fixing of PVC angle/ batten Holder including connections etc as required . |
| 41 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnatic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel ,making connections etc. as required . A. 30 kA, 100 amps four pole |
| 42 | B. 36 kA, 125 amps four pole |
| 43 | Supplying and fixing of following sizes of PVC/G.I box on surface / recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. A. 75 mm x 75mm x 60mm deep/ (4\\" x 4\\") |
| 44 | B. 100mm x 100mm x 60mm deep/ (4\\" x 7\\") |
| 45 | C. 200 mm x 125mm x 60mm deep/ (6\\" x 8\\") |
| 46 | Supply and fixing of off load Changeover switch (side handle) in sheet enclosure 415 V AC of following rating (Make - Havells, HPL, L&T or equivalent). A. 200 amps |
| 47 | Providing and fixing following capacity busbar chamber with 4 strips of length 300mm made of copper suitable for following capacity complete with all accessories including connections, earthing the body etc. as required. A. 4 way 100 amps |
| 48 | Supplying and fixing stepped type electronic fan regulator on the existing switch box including connection but excluding plate etc. as required. |
| 49 | Supply of material and laying in ground including sand brick etc. complete 1.1 KV grade single tape armoured aluminium cable of following sizes including glanding crimping connections etc per meter of length (Make - Havells, Polycab or equivalent). A. 4 core 10 sq.mm |
| 50 | B. 3 1/2 core 25 sq.mm |
| 51 | C. 2 Core 06 sq. mm |
| 52 | Supply and fixing of 100 W LED street light luminare as required : (make Havells ,philps , HPL ,or reputed Make..) |
| 53 | Supply and fixing of LED batten light tube fitting 20 W LED 6500k (make - Havells ,philps , HPL ,or reputed Make..) |
| 54 | Supply and fixing of following size LED flood light as required : (make havells,bajaj , HPL ,or reputed Make..). A. 100 W LED |
| 55 | Supply and fixing of street light holding arm 1 Mtr. Long. |
| 56 | Earthing with G.I. earth pipe 4.5 mtr long . 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required |
| 57 | Supply and installation of 450 mm (18\\") metal body wall fan with speed regulator suitable for Single phase 220V,50HZ AC supply |
| 58 | Supply and installation of 1200 mm Ceiling fan with speed regulator suitable for Single phase 220V,50HZ AC supply |
| 59 | Supply and installation of 450 mm (18\\") metal body Exhaust fan suitable for Single phase 220V,50HZ AC supply |
| 60 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |