| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 2 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | Providing and laying in position cement concrete ofspecified grade excluding the cost of centering andshuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 6 | Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete upto plinth level.Hot rolled deformed bars |
| 7 | Centring and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. |
| 8 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. Complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 9 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 10 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : With cement mortar 1:4(1 cement: 4 coarse sand). |
| 11 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 12 | 12 mm cement plaster of mix: 1:6 (1 cement : 6 fine sand) |
| 13 | Providing & Applying polymer modified, flexiblecementatious negative side waterproofing coating withelastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of selfpriming of cementatious waterproofing polymer(dilutionwith water in the ratio of 1:1) and two coats of cementatiouswaterproofing polymer (dilution with water in the ratio of3:1 ) after scrapping and properly cleaning the surface toremove pre-existing paint film & loose particles till plaster isvisible, complete in all respect as per the direction ofEngineer-in-Charge. |
| 14 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 15 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. |
| 17 | Removing white or colour wash by scrapping and sandpapering and preparing the surface smooth includingnecessary repairs to scratches etc. Complete |
| 18 | Finishing walls with textured exterior paint of required shade : Old work (One or more coats) applied @ 1.82 ltr/10 sqm. |
| 19 | Distempering with 1st quality acrylic distemper (readymixed) having VOC (Volatile Organic Compound ) contentless than 50 gram/ litre, of approved brand and of requiredsaid and colour complete to give and even said. Old work (one or more coats) |
| 20 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 21 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 22 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below |
| 23 | Taking out existing wooden door shutter, repair by cutting,painting etc. and refixing of repaired door shutters toexisting door frames, including replacement of hinges withscrews, etc. as required, all complete as per the direction ofthe Engineer-in-charge. |
| 24 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal Size). |
| 25 | Providing and fixing ISI marked flush door shuttersconforming to IS : 2202 (Part I) non-decorative type, coreof block board construction with frame of 1st class hardwood and well matched commercial 3 ply veneering withvertical grains or cross bands and face veneers on bothfaces of shutters: 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 26 | Providing and fixing ISI marked flush door shuttersconforming to IS : 2202 (Part I) non-decorative type, coreof block board construction with frame of 1st class hardwood and well matched commercial 3 ply veneering withvertical grains or cross bands and face veneers on bothfaces of shutters: 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary Screws |
| 27 | Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers(wood powder/ rice husk/wheat husk) and non toxicadditives (maximum toxicity index of 12 for 100 gms)having minimum density of 650 kg/cum and screwwithdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength 50 N/mm2, modulus ofelasticity 850 N/mm2 and resistance to spread of flame ofClass A category with property of being termite/borerproof, water/moisture proof and fire retardant and fixingwith stainless steel butt hinges of required size withnecessary full body threaded star headed counter sunk S.Sscrews, all as per direction of Engineer-In- Charge. (Note:stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick |
| 28 | Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid door/window/Clerestory Yvindows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and Natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVCsolvent cement and screwed with full body threaded starheaded SS screws having minimum frame density of 750kg/cum, screw withdrawal strength of 2200 N (Face) &1100 N (Edge), minimum compressive strength of 58N/mm2, modulus of elasticity 900 N/mm2 andresistance to spread of flame of Class A category withproperty of being termite/borer proof, water/moistureproof and fire retardant and fixed in position with M.Shold fast/lugs/SS dash fasteners of required dia and lengthcomplete as per direction of Engineer-In- Charge. (M.S holdfast/lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mmtolerance in dimensions i.e depth and width of profile shallbe acceptable. Variation in profile dimensions on plus sideshall be acceptable but no extra payment on this accountshall be made. Frame size 45x 70mm |
| 29 | Providing and fixing ISI marked oxidised M.S. sliding doorbolts with nuts and screws etc. complete : 250X16 mm |
| 30 | Providing and fixing ISI marked oxidised M.S. tower boltblack finish, (Barrel type) with necessary screws etc.Complete : 150 X10 mm |
| 31 | Providing and fixing ISI marked oxidised M.S. handlesconforming to IS:4992 with necessary screws etc.Complete :125 mm |
| 32 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less tha grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete : 150 x10 mm |
| 33 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. Complete : 125 mm |
| 34 | Providing and fixing aluminium sliding door bolts, ISImarked anodised (anodic coating not less than grade AC10 as per IS : 1868), transparent or dyed to requiredcolour or shade, with nuts and screws etc. Complete : 250x16 mm |
| 35 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in – charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 36 | Dismantling W.C. Pan of all sizes including disposal ofdismantled materials i/c malba all complete as perdirections of Engineer-in-Charge. |
| 37 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White Vitreous China Orisssa pattern W.C. pan of size 580 x 440 mm with integral type foot rests |
| 38 | Providing and fixing White Vitreous China pedestal type water closet (European type W.C. pan ) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid |
| 39 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter |
| 40 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 75 mm |
| 41 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 42 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. Complete.110 mm |
| 43 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110X110X110 mm |
| 44 | Providing and fixing 10 cm PVC nahani trap with grating etc. Complete. |
| 45 | Providing,laying and fixing,jointing Eco drain 110 mm SN8 NuDrain Upvc pipes or of equivalent make,manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends,tees,coupler,etc,jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. Complete. |
| 46 | Providing, laying and fixing,jointing Eco drain 160 mm SN8 NuDrain Upvc pipes or of equivalent make,manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends,tees,coupler,etc,jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. Complete. |
| 47 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 470x420 mm bowl depth 178 mm |
| 48 | Providing and fixing wash basin with C.I. brackets, 15 mmC.P. brass pillar taps, 32 mm C.P. brass waste of standardpattern, including painting of fittings and brackets, cuttingand making good the walls wherever require: White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap |
| 49 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe 32 mm dia |
| 50 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 51 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 52 | Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. Complete. |
| 53 | Providing and fixing Ist quality ceramic glazed wall tilesconforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados,over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 54 | Providing and fixing plain lining with necessary screws/ nuts & bolts / nails, including a coat of approved primer on one face, and fixed on wooden / steel frame work , complete as per direction of Engineer incharge (frame work shall be paid for separately ). 12 mm thick commercial ply conforming to IS : 1328 BWR type. |
| 55 | Providing and fixing acrylic plastic sheet panels of approved quality in required thickness plain clear or any colour or obscured linings in lieu of glass pans to doors / windows including providing and fixing clips, putty etc. Complete . (b) 3 mm thick. |
| 56 | Providing and fixing 600x450 mm beveled edge mirror ofsuperior glass (of approved quality) complete with 6 mmthick hard board ground fixed to wooden cleats with C.P.brass screws and washers complete. |
| 57 | Providing and fixing M.S. grills of required pattern inframes of windows etc. with M.S. flats, square or roundbars etc. including priming coat with approved steelprimer all complete. Fixed to steel windows by welding |
| 58 | Finishing with Epoxy paint (Two or more coats ) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface ,etc. Complete. On concrete work |
| 59 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 60 | Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box |
| 61 | Providing 25 mm to 30 mm thick partition of polished black Kadappa stone slab of approved quality including giving required size & shape etc. Fixing in cement mortar 1:3 curing and cement etc. Complete. a) One side polish |
| 62 | structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 63 | Supplying of Ferric alum including transportation charges. |
| 64 | Supplying of Chlorine liquid including transportation charges. |
| 65 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces |
| 66 | Providing and fixing pre coated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shapewherever required. |
| 67 | Constructing brick masonry manhole in cement mortar 1:4( 1 cement : 4 coarse sand ) with R.C.C. top slab with1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 gradedstone aggregate 20 mm nominal size), foundation concrete1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 gradedstone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarsesand) finished with floating coat of neat cement andmaking channels in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominalsize) finished with a floating coat of neat cement completeas per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 68 | Extra for depth for manholes : Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 |
| 69 | Providing, hoisting and fixing upto floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span upto floor five level including the cost of required centring, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surfaces but excluding the cost of reinforcement with 1:1.5:3(1 cement: 1.5 coarse sand : 3 graded stone aggregate 20mm nominal-size). |
| 70 | Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS :12894, in super structure above plinth and upto floor V level. : Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 71 | Neat cement punning. |
| 72 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, bymechinical / manual means ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: Pipes, cables etc, not exceeding 80 mm dia. But not exceeding300mm dia |
| 73 | Providing and fixing bolts including nuts and washersComplete. |
| 74 | Providing and fixing PTMT extension nipple for water tankpipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms |
| 75 | Providing and fixing PTMT grating of approved quality andColour. 100 mm nominal dia |
| 76 | White washing with lime to give an even shade : Old work (two or more coats) |
| 77 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete: New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 pram/litre |
| 78 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 79 | Reinforced cement concrete work in beams, suspended foors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 80 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 81 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats Two coats |
| 82 | Finishing walls with textured exterior paint of required shade : Finishing walls with textured exterior paint of required shade : Old work (Two or more coats on existing cement paint surface applied @ 3.28 Itr/10 sqm. |
| 83 | Providing and fixing chromium plated brass handles with necessary screws etc. Complete: 125 mm |
| 84 | 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multichambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). |
| 85 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 86 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal dia Pipes |
| 87 | 20 mm nominal dia Pipes |
| 88 | 25 mm nominal dia Pipes |
| 89 | 50 mm nominal dia Pipes |
| 90 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 15 mm dia nominal bore |
| 91 | 20 mm dia nominal bore |
| 92 | 25 mm dia nominal bore |
| 93 | 50 mm dia nominal bore |
| 94 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : 25 mm dia (heavy type) |
| 95 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 96 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 97 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20rnm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 98 | Constructing soak pit 1.20x1.20x1.70 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 99 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White |
| 100 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M 30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 101 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |