| 1 | Excavation in Foundation in ordinary soil (Loamclay or sand) including lift up to 1.5m and lead up to 30m. and including filling, watering and ramming of excavated earth into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the E/I up to a distance of 30m. from the foundation trenches including all T&P phowereh and basket etc. complete. SOR NO.-251 |
| 2 | Concrete with 4cm gauge brick ballast, coarse sand. and cement in proportion 10:5:1 in foundations and under floors including supply of all materials labour and tools and plants etc. required for proper complation of the work.SOR NO.-274 |
| 3 | R.C.C.Work with cement approved coarse sand and 2cm gauge stone girt (Dala) in the propotion of 1:1.5:3 (M-20) in Column Footing excluding supply of reinforcement and its bending but including fixing and bending the same with 24 B.W.G.G.I. banding wire and including necessary centering and shuttring etc.& also including supply of all materilas, labour and T&P etc. required for proper completion of work.As per S.I.No.285 B |
| 4 | R.C.C. Work with cement approved coarse sand and 20 mm gauge (nomianl size) dalla stone aggregate in the proporation of 1:1.5:3 M-20 in R.C.C. Column excluding supply of reinforcement and its bending but including its fixing and binding the same with 24 B W.G.G.I. binding wire and as required supply of all materials, labour centering and shuttering and removal of the same after completion of work. SOR.No. 289 |
| 5 | RCC work with cement C sand and 20 mm Stone grit in 1:2:4 in plinth and lintels bends and sunshed of doors and window S.I. No.-283. |
| 6 | RCC work with cement C sand and 20 mm Stone grit in 1:1.5:3 in Lighter Beam S.I. No.-285B |
| 7 | RCC work with cement C sand and 20 mm Stone grit in 1:1.5:3 in Lighter Beam S.I. No.-284 B |
| 8 | Mild steel or iron in plain work such as in reinforced concrete work to required shape as necessary including dending for proper completion of the work and including supply of steel its wastage. Bend books and authorized overlapping shall be measured. SI No. 504 |
| 9 | Brick work in 1:6 cement and coarse sand of in foundation and plinth including supply of all material, labour tools and plants. etc. required for proper completion of work As per S.I. No. 303.1.A |
| 10 | M-150 class brick work 1:4 cement and approvel Coarse sand in super structure and plinth including supply of all material, labour and tools and plants etc. required for proper completion of work. But in super structure including necessary cutting and moulding of brick work, thikness of wall more than one break and for extra lab our to above items. But walls of one brick 230 mm thick add for extra lab our over item no. S.I.No. 305B+310 |
| 11 | Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level . Cement mortar 1:4 (1 cement :4 coarse sand) PARTITION WALL.SOR NO. 305B+311 |
| 12 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to 1S: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover. D.S.R. NO. 10.6.2 |
| 13 | Fabrication and supply of M.S. grill as per approved design and drawing including the stair case railling etc. with square bars, m.s. angle iron, and m.s. flat iron as per direction of Engineer-incharge, supply of steel and its wastage, cutting, drilling holes and welding joints where necessary including each joint tube perfectaly welded and jointed and grinded to smooth finish. As per SOR NO.-503 |
| 14 | 12 mm. thick plaster in 1:3 cement and coarse sand.required for proper completion of work. As per S.I. No. 583, |
| 15 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 2.5cm thick with 20 mm nominal size stone aggregate.SOR No.601 |
| 16 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per DSR 13.80 |
| 17 | One priming coat of cement primer and two coat oil distemper on new work including supply of material,T&P required for proper completion of work SI No.649+650 |
| 18 | Finishing walls with waterproof cement paint on new work with two coat over one coat primer including supply of all material, labour, T & P complete as per S.I. No. 660 |
| 19 | Two coat painting over one coat primer including supply of all material, labour and tools & plants etc. required for proper completion of the work.as per direction of E/I As per S.I. No. 641 & 642. |
| 20 | ELECTRICAL BOQ |
| 21 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A for Light as per DSR 1.10.1 |
| 22 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B for Fan as per DSR 1.10.2 |
| 23 | LED batten light supplying installation testing & commosioning of LED surface mounted batten light of folowing body material and theconstruction as per IS 10322 with driver , oprating voltage AC 140 volt feq 50/60 hz , 24-26 watt as per DSR2025 8.9.2 |
| 24 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. as per DSR 9.1.3 |
| 25 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver. 5 - 7 watt.DSR No.8.1.1 |
| 26 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 A switch as per DSR 1.24.1 |
| 27 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 3 pin 5/6 A socket as per DSR 1.24.4 |
| 28 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 15/16 A switch as per DSR 1.24.3 |
| 29 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 6 pin 15/16 A socket outlet as per DSR 1.24.5 |
| 30 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm).DSR NO.1.27.3 |
| 31 | Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. as per DSR 1.57 |
| 32 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. as per DSR 10.18 CIVIL Please Enable Macros to View BoQ information |