| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- Short Point :- |
| 2 | Medium Point :- |
| 3 | Long Point :- |
| 4 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 5 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 6 | Wiring for Circuit/Sub-main wiring with the following sizes PVC insulatedcopper conductor cable (FR) in PVC casing capping etc. as required:- 2 x 1.5sq.mm:- |
| 7 | 2 x 2.5 sq.mm:- |
| 8 | 2 x 4 sq.mm:- |
| 9 | 2 X 6 sq mm:- |
| 10 | 4 X 6 sq mm:- |
| 11 | 4 X 10 sq mm |
| 12 | 4 X 16 sq mm |
| 13 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- 1 X 1.5 sq mm |
| 14 | 1 X 2.5 sq mm |
| 15 | 1 X 4 sq mm |
| 16 | 1 X 6 sq mm |
| 17 | Supplying and fixing of the following PVC casing capping with all accessories etc. as required :- 25mm x 12mm |
| 18 | Supplying and fixing of the following PVC conduit (medium gauge) with all accessories on slab/recessed on wall etc as required.: 19/20 mm dia |
| 19 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. : Ding dong call bell |
| 20 | Musical call bell |
| 21 | 3mm thick bakelite sheet |
| 22 | 15 amps power top:- |
| 23 | 32 amps DP kit kat switch:- |
| 24 | Supplying and fixing of the following sizes wooden switch boards with 3mm thick bakelite cover etc. as required.: 300mm x 380mm (12\\" X 15\\") :- |
| 25 | Supplying and fixing of the following sizes PVC switch boards with cover etc. as required.: 1-2 module plastic switch board:- |
| 26 | 6 module plastic switch board:- |
| 27 | 12 module plastic switch board:- |
| 28 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required.: 1-2 module :- |
| 29 | 6 module :- |
| 30 | 12 module :- |
| 31 | Supplying and fixing of the following modular accessories including necessary connection etc. as required.: 6/10 amps one way SP switch (1M) :- |
| 32 | 3 pin 6/10 amps socket outlet (2M):- |
| 33 | 16/20 amps one way SP switch (1M) :- |
| 34 | 3/6 pin 16/20 amps socket outlet (2M):- |
| 35 | 20/25 amps single phase motor starter switch (2M):- |
| 36 | 5 step fan regulator (2M):- |
| 37 | Blank plate (1M):- |
| 38 | Bell push SP (1M) :- |
| 39 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required. |
| 40 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 41 | Earthing with Copper earth plate 600 mm x 600 mm x 3 mm thick i/c accessories and providing masonry enclosure with CI cover plate Size 12\\"x 12\\" having locking arrangement, along with 20 mm dia (medium gauge) watering pipe including CC work etc as required:- |
| 42 | Extra for using salt (12 kg) and charcoal (96kg) for plate earth electrode as required. |
| 43 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
| 44 | Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for loop earthing as required. |
| 45 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required. |
| 46 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 47 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:- |
| 48 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:- |
| 49 | Supplying & installation of 400 mm sweep AC padestal fan with metal blade including connection etc as required:- |
| 50 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required: |
| 51 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 52 | Supplying and fixing of following vertical storage water heater 5 star catagory complete with 15 amps top, connection pipes including necessary connection etc as required.: 25 litre storage capacity:- |
| 53 | Supplying and fixing of following luminaries complete with necessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):- Bulk head fittings with frosted/clear glass suitable for GLS or retrofit CFL/LED (without lamp) : - |
| 54 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 55 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- 60 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 56 | 90 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 57 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 58 | 12 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 59 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- 63 amps 415 volts four strip Copper busbar chamber 6 ways of size (455mmx330mmx120mm):- |
| 60 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:- 32 amps 240 volts DP main switch (rewireable):- |
| 61 | 63 amps 415 volts TPN main switch (rewireable):- |
| 62 | Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:- 63 amps kitkat porcelain fuse unit with base(rewireable):- |
| 63 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.: 4 way SPN MCB DB (double door):- |
| 64 | (2+6) / 8 way SPN MCB DB (double door):- |
| 65 | (2+10) / 12 way SPN MCB DB (double door):- |
| 66 | 4 way horizontal TPN MCB DB (Double door):- |
| 67 | 6 way horizontal TPN MCB DB (Double door):- |
| 68 | Supplying & fixing of following ratings MCB B/C curve having breaking capacity 10 KA in the existing MCB DB including connection as required:- 6 to 32 amps SP MCB:- |
| 69 | 40/50/63 amps TPN MCB:- |
| 70 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- 40 amps DP isolator:- |
| 71 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required : 3 core 4 sq mm |
| 72 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: - 6 sq mm |
| 73 | 10 sq mm |
| 74 | 16 sq mm |
| 75 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : - 1.5 sqmm - 4 sqmm Cable:- |
| 76 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- 40 mm dia |
| 77 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:- |
| 78 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- |
| 79 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 80 | Supplying of 25 cm long ‘L’ hook made with 40mm x 6mm MS flat and fixing with necessary fasten nuts including finishing, painting etc as required.- |
| 81 | Decorative wall light luminaire with frosted glass and chrome finish base including 9W LED bulb (base:E27) complete with all other necessary accessories including connection etc. as required (CCT 3000K/4000K) :- |
| 82 | Supplying, installation and fixing of 18/20W LED tubelight with industrial compact batten suitable for single tubelight with integral LED Driver in double side connection etc as required (CCT 6500K) :- (with 50000 burning hours and minimum lumen output of 2100 lm/watt):-(Cat No: TMC 502 1 x T-LED 22W, PHILIPS make OR similar specifications from Jaguar/Havells make)):- Please Enable Macros to View BoQ information |