| 1 | Item Description |
| 2 | M&L for preparation of old plastered or unplastered surface of wall including brooming down or steel wire brushing, scrapping down smoke soot, moulds, mass and efflorescent salts and trading oil and greasy spots including filling of holes with wall care putty and apply two coats of white wash on wall surface (white or tinted) including scaffolding all as speified and directed. Colour and shade as approved by EIC. |
| 3 | M&L for preparation of old plastered or unplastered surface of wall including brooming down or steel wire brushing, scrapping down smoke soot, moulds, mass and efflorescent salts and trading oil and greasy spots including filling of holes with wall care putty and apply two coats of white wash on ceiling surface including scaffolding all as speified and directed. (white or tinted) Colour and shade as approved by EIC. |
| 4 | M&L for preparation of old plastered or unplastered surface of wall including brooming down or steel wire brushing, scrapping down smoke soot, moulds, mass and efflorescent salts and trading oil and greasy spots including filling of holes with wall care putty and apply two coats of distempering oil bound distemper on wall surface including scaffolding all as speified and directed (white or tinted) Colour and shade as approved by EIC. (Make-Asian/Berger/Nerolac) |
| 5 | M&L for preparation of old plastered or unplastered surface ofceiling including brooming down or steel wire brushing, scrapping down smoke soot, moulds, mass and efflorescent salts and trading oil and greasy spots including filling of holes with wall care putty and apply one coat of distempering oil bound distemper on ceiling surface including scaffolding all as speified and directed (white or tinted) Colour and shade as approved by EIC. (Make-Asian/Berger/Nerolac) |
| 6 | M&L for 3mm thick wall care puty on wall. Make - JK, Birla, Asian |
| 7 | M&L Preparation of old decorated wooden surface over 10 CM width or girth and apply one coat of synthetic enamel on wooden surface. Colour shade and make as approved by EIC. (Make-Asian/Berger/Nerolac) |
| 8 | M&L Preparation of old decorated steel surface of any description, over 10 cm width and girth, not otherwise described and apply one coat of synthetic enamel paint on steel surface. Colour shade and make as approved by EIC. (Make-Asian/Berger/Nerolac) |
| 9 | M&Lfor finishing walls with Acrylic smooth exterior paint of required shade on old work (Two or more coats applied @ 1.67 ltr/10 sqm) on existing cement paint surface as directed by EIC. (Make-Asian Apex Shyne exterior/Berger walmasta glow exterior/Nerolac suraksha plus nxt), |
| 10 | M&L for French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on old works with one or more coats. |
| 11 | Taking down damaged cement plaster on brick walls etc. including raking out joints, hacking for key, scrubbing down with water etc. including root out the wild growth and make good with cement mortar 1:4 mix as directed. |
| 12 | M & L for Rendering 12 mm thick on fair faces of brick work or concrete surface with cement plaster 1:4. including Use of all scaffolding, trestles, ladders, cradles, etc. plaster at height if any , necessary for execution of work and protective measures. |
| 13 | M&L for removal of previous water proofing APP membrane from the (Existing roof consist of Solar panels installed on entire roof), cleaning of old layer with wire brush, removing of old loose concrete, filling of brick layer gap with suitable cement/concrete material if any and surface should be dry cleaned and free from oil and grease and existing bitumen surface, loose particles should be removed and damaged spots should be repaired first with cement concrete. First part consist of cut and widen all Cracks in V shape in the size of 8-10mm width and fill the cracks with Dr fixit PU sealant or feviseal HY 100/200 sealant. Second part consist of Apply a priming coat of Dr. fixit Roofseal select, diluted with water in a 2(Roofseal select):1(water) ratio, as a self priming coat . Third part consist of Apply first coat of Dr fixit roofseal select at a rate of 0.45-0.50 ltr/sqm/coat. A glass fibre mesh of size 2.5mmx 2.5mm is sandwiched between the first and second coats while the first coat is still wet. Allow the first coat to dry for 4-6 hrs. Fourth part consist of Apply second and third coats of Dr. fixit roofseal select with the same application coverage, but in direction perpendicular to that of the first and second coats. Allow each coat to air cure for a minimum of 4-6 hours after application Lastly the waterproof area must be air cured for minimum 24-48 hours. Conduct pond test for minimum 24 hrs with 4 inch water head. |
| 14 | M&L for Providing, cement concrete Type B0 1:2:4 (12.5mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges of existing installed solar panels CC blocks bases/sides as directed. |
| 15 | Cutting or uprooting grass/wild growth any type of roof removing old APP treatment, removing rubbish off the premises, cleaning surface and preparing to receive new plaster as directed . |
| 16 | Demolition of cement concrete (un-reinforced) of any description and in any position. |
| 17 | M&L for brushing neat cement slurry with 3.0 kg of cement per sqm and rendering 30 mm thick cement plaster with 1:4 cement mortar on fair faces of brick surface or concrete surface as directed by EIC. |
| 18 | M&L for applying evenly a bitumen cutback priming/tack coat with bituminous primer at 10 kg per 10 SqM |
| 19 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified. Make- Asian, Dr Fixit, STP |
| 20 | M&L for 100mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) |
| 21 | Removing surplus excavated and demolished material to a distance exc 250m but n exc 500m and depositing where directed in soils. Please Enable Macros to View BoQ information |