| 1 | Total amount of the \\"Rate Schedule\\" sheet SCHEDULE OF QUANTITY AND RATE FOR REPLACEMENT OF ACSR BARE CONDUCTOR BY 11 KV AAAC AL-59, 99 SQMM. COVERED CONDUCTOR OF 11 KV TOWN FEEDER UNDER 33/11 KV SUB-STATION, LACHHIWALA UNDER EDSD, DOIWALA UNDER EDD, DOIWALA AGAINST E-TENDER SPECIFICATION NO.19/EDCRDDUN/2026-27 Name of The Bidder's Firm: 0.0 Sl. No. Description of Work Unit Qty Rate Amount Part [A] (Supply Portion) |
| 2 | LT Clamp for ST Pole SP-55 With N&B |
| 3 | PP & Clamp for ST Pole SP-55 with N&B |
| 4 | Stay Clamp for ST Pole SP-55 with Nut & Bolt |
| 5 | Stay Clamp for ST Pole SP-33 with Nut & Bolt |
| 6 | PP & Clamp for ST Pole SP-33 with N&B |
| 7 | Shackle Insulator 100x115 mm. with N&B |
| 8 | Stay Insulator |
| 9 | IPC with Aluminium Bail for Earthing |
| 10 | 11 KV Cable Ties for Pin Insulator |
| 11 | 11 KV IPC for Covered to Covered Conductor |
| 12 | 11 KV IPC for Covered to Bare Conductor |
| 13 | 11 KV Mid Span Jointing Kit |
| 14 | 11 KV Tension Clamp with Bail & IPC |
| 15 | 11 KV AAAC Covered Conductor AL-59, 99 Sqmm. Total - Part [A] 0.0 Part [B] (Labour Portion) |
| 16 | Cartage of ST pole from store centre to construction site with loading, unloading at both points and proper stacking. SP-33 (approx 51-70 Km.) Nos 10.0 0.0 SP-55 (approx 0-20 Km.) Nos 8.0 0.0 |
| 17 | Cartage of other material (other than poles) by vehicle fro Store Center to nearest construction site Store including loading and unloading at both ends. (0-20 Km.) Rs.Per Qtl. Qtl 25.6 0.0 |
| 18 | Head load cartage of following Poles from road to site. Upto 0 to 1 Km. SP-33 Nos 10.0 0.0 SP-55 Nos 8.0 0.0 |
| 19 | Earthing with M.S. Earth rod of 2.5 meter long by hammering of M.S. Rod to proper depth and connecting the earth electrode with the help of G.I. wire as per construction manual. |
| 20 | Fabrication of M.S. Channel Angle iron after cutting in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESPO sehedule and local approved drawing. |
| 21 | Excavation of earth for stay pit of size 0.06x0.06x1/2 mtr. in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work |
| 22 | Fixing , tightening and nozzaling of Stay with pole and stay rod on required tension as per drawing / RESPO manual. 11 KV line Nos 8.0 0.0 |
| 23 | Grouting of Stay in size 0.6x0.6x0.3 in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cernent,sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESPO Manual. |
| 24 | Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work |
| 25 | Erection of following Single support pole in proper level and alignment alongwith fixing of all accessories, like top channel & clamps as per RESPO construction Manual. SP-33 Nos 10.0 0.0 SP-55 Nos 10.0 0.0 |
| 26 | Grouting of pole in size 0.45x0.45x1/9 of the support in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cement,sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESPO construction Manual. |
| 27 | Muffing of poles size 0.45 cm x 0.60 cm radius with cc 1:3:6 (1 cement: 3 coarse sand : 6 graded stone 10mm nominal size) block size 45cm height from ground level including cost of cement, stone and sand etc. |
| 28 | Dismantling of SP-33 Single Pole |
| 29 | Dismantling of Guarding in 11 KV line |
| 30 | Erection of Bracket in 11 KV line |
| 31 | Guarding of LT/11 KV line |
| 32 | T-off Connection complete 11 KV line |
| 33 | Disconnection & Reconnection of Consumer Service Cable |
| 34 | Dismanlting & Reinstallation of Street Light |
| 35 | Laying of LT XLPE AB Cable 3x95+1x70 sqmm. |
| 36 | Dismanlting of LT XLPE AB Cable 3x95+1x70 sqmm. |
| 37 | Tightening of Stay Set |
| 38 | Back Cartage of Petty Material, 0-20 km |
| 39 | Fixing of IPC with Aluminium Bail for Earthing |
| 40 | Jumpering and connection complete on the D/P conductor to TPMO fuse set & T/F |
| 41 | Realignment of Tilted Pole |
| 42 | Fixing of 11 KV 90KN Tension Clamp B&IPC |
| 43 | Fixing of 11 KV Suspension Ties |
| 44 | Fixing of 11 KV Mid Span Jointing Kit |
| 45 | Fixing of 11 KV IPC for Covered to Covered Conductor |
| 46 | Fixing of 11 KV IPC for Covered to Bare Conductor |
| 47 | Fixing of Disc Insulator for AAAC Conductor |
| 48 | Fixing of 11 KV Pin Insulator |
| 49 | Supply & Fixing of Anti Climbing Device |
| 50 | Laying, Spreading and Stringing of AAAC Conductor |
| 51 | Removing Old Conductor by Opening Jumper |
| 52 | Route cleareance by cutting of tree branches / pruning, lopping and chopping of trees for L.T., 11 & 33 KV line. Total - Part [B] 0.0 TOTAL [Part-(A) + Part (B)] 0.0 Place Date Superintending Engineer Please Enable Macros to View BoQ information |