| 1 | Schedule-A |
| 2 | Dismantling of existing roof Treatment including Taking down of roof plaster of any description all as specified and as directed by Engr-in charge.Rate of this item is inclusive of disconnect fitment of solar water tank or solar Panel ,any type of cable ,Pipes etc and refixing in the same position after completing of roof treatment.complete all as specified and directed by Engineer-in-Charge..complete all as specified and directed by Engineer-in-Charge. |
| 3 | Demolition of Cement Concrete (un-reinforced) of any description, not exc. 150mm thickness (above or below Ground Level) and removing the same from Site(s),complete all as specified and directed by Engineer-in-Charge. |
| 4 | M&L for 25mm thick PCC 1:2:4 Type B0 (12.5mm Graded Stone Aggregate) as in sub floor, sub bases, floors,roof etc., including rough top surface to receive floor finish complete all as specified and directed by Engineer-in-Charge. |
| 5 | M&L providing cement concrete in roof or mud stops using type B-1, 1:2:4 (20mm graded aggregate) rounded or chamfered on edges or making slope as in coping, benching, roof levelling course, bed block for flooring, rungs, window cills etc. complete all as specified and directed by Engineer-in-Charge. |
| 6 | Demolition of brick work or stone/boulders masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etac but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and directed by Engineer-in-Charge. |
| 7 | M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mena radius built in cement mortar 1:4. complete all as specified and directed by Engineer-in-Charge. |
| 8 | Taking down Cement Plaster from wall and ceiling of any description from Brick/concrete surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and directed by Engineer-in-Charge. |
| 9 | M&L for 15 mm thick cement plastering in CM 1:4 on brick/concrete surfaces of roof and parapet, mixed with water proofing compound, finished even and smooth without using extra cement . complete all as specified and as directed by Engineer-in-Charge. Note :- 1)Water proofing compound shall be measured & paid separately. . |
| 10 | Supply only liquid water proofing compound |
| 11 | M&L for 10mm thick cement rendering in CM 1:3 on brick/concrete surfaces of roof, mixed with water proofing compound,and finishing the surface even and smooth before application of priming coat complete all as specified and directed by Engineer-in-Charge. |
| 12 | M&L for preparation of surface by scrapping and properly cleaning the existing roof . Apply first coat Fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with Sun Reflective Index (SRI) of 100-110, having minimum elongation of 350%, tensile strength of 2.9 Mpa and shall have cracks bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure reduce surface temperature upto 10 degree Celsius with 33% dilution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45 gsm/sqm and pasting it properly with overlap of 50mm and allow it to dry. Apply second of undiluted coat @ 0.45ltr/sqm. Apply third and final coat undiluted @0.45ltr/sqm complete all as specified and directed by Engineer-in-Charge. Note: 1) Work to be carried out by authorised applicator as per manufacturers instructions. 2)The surface will be testing for leakage/seepage for water ponding for 48 hrs. |
| 13 | M&L for brick wall treatment by applying two component elastomeric omeric acrylic polymer modified cementitious waterproofing coating, SmartCare Ultra Block 2K or approved equivalent, having >220 % elongation as per ASTM D 2370, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 3.5 mm as per EN 1062. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturers specifications. Minimum consumption shall be 2kg/sqm. Supply and applying bond coat application mix AP SC Repair Polymer and cement in ratio of 1:1. Brush apply 1 or 2 continuous coat of mix and ensure minimum consumption shall be 0.2kg/sqm. complete all as specified and directed by Engineer-in-Charge. Note: 1) Work to be carried out by authorised applicator as per manufacturers instructions. |
| 14 | M&L for PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in coping, benching, roof levelling course, bed block for flooring, rungs, window cills etc complete all as specified and directed by Engineer-in-Charge. |
| 15 | M & L two coats of cement based paint on newly plastered surface including all preparation complete all as spd and directed. complete all as specified and directed by Engineer-in-Charge. |
| 16 | M&L for preparation of newly plastered surfaces of walls by Vacuum based sanding machine complete all as specified, applying wall care putty min 2mm thick (multi purpose mixer shall be used for uniform and proper mixing of putty), primer and applying two coats oil emulsion distemper white or coloured by auto roller complete all as specified and directed by Engineer-in-Charge. |
| 17 | M&L for preparation of newly plastered surfaces of ceiling by Vacuum based sanding machine complete all as specified, applying wall care putty 2mm thick (multi purpose mixer shall be used for uniform and proper mixing of putty),primer and applying two coats oil emulsion distemper white or coloured by auto roller complete all as specified and directed by Engineer-in-Charge. |
| 18 | Taking up or down unserviceable Steel Water Tubing 80mm bore(dia) in any situation, with Fittings and Connections, such as socket, elbow, tee, union,reducer socket,tee reducer etc, complete all as specified and directed by Engineer-in-Charge. |
| 19 | S&F Galvanised Steel Water Tubing 80 mm Bore (dia), ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situ-ation such as socket, elbow, tee, union,reducer socket,tee reducer etc., complete all as specified and directed by Engineer-in-Charge. |
| 20 | Refixing old steel tubing 80 mm bore (dia)& connections in new or old position (Walls, ceiling, floors, etc.) in any Situation including replacement of old un serviceable fittings such as socket, elbow, tee, union,reducer socket,tee reducer etc. complete all as specified and directed by Engineer-in-Charge. |
| 21 | Taking up or down unserviceable Steel Water Tubing 50mm bore(dia) in any situation, with Fittings and Connections, such as socket, elbow, tee, union,reducer socket,tee reducer etc, complete all as specified and directed by Engineer-in-Charge. |
| 22 | S&F Galvanised Steel Water Tubing 50 mm Bore (dia), ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situ-ation such as socket, elbow, tee, union,reducer socket,tee reducer etc., complete all as specified and directed by Engineer-in-Charge. |
| 23 | Refixing old steel tubing 50 mm bore (dia) & connections in new or old position (Walls, ceiling, floors, etc.) 100mm Bore (dia), in any Situation including replacement of old un serviceable fittings such as socket, elbow, tee, union,reducer socket,tee reducer etc. complete all as specified and directed by Engineer-in-Charge. |
| 24 | Taking up or down unserviceable Steel Water Tubing 32mm bore(dia) in any situation, with Fittings and Connections, such as socket, elbow, tee, union,reducer socket,tee reducer etc, complete all as specified and directed by Engineer-in-Charge. |
| 25 | S&F Galvanised Steel Water Tubing 32 mm Bore (dia), ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situ-ation such as socket, elbow, tee, union,reducer socket,tee reducer etc., complete all as specified and directed by Engineer-in-Charge. |
| 26 | Refixing old steel tubing 32 mm bore (dia) & connections in new or old position (Walls, ceiling, floors, etc.) 100mm Bore (dia), in any Situation including replacement of old un serviceable fittings such as socket, elbow, tee, union,reducer socket,tee reducer etc. complete all as specified and directed by Engineer-in-Charge. |
| 27 | Taking up or down unserviceable Steel Water Tubing 25mm bore(dia) in any situation, with Fittings and Connections, such as socket, elbow, tee, union,reducer socket,tee reducer etc, complete all as specified and directed by Engineer-in-Charge. |
| 28 | S&F Galvanised Steel Water Tubing 25 mm Bore (dia), ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situ-ation such as socket, elbow, tee, union,reducer socket,tee reducer etc., complete all as specified and directed by Engineer-in-Charge. |
| 29 | Refixing old steel tubing 25 mm bore (dia) & connections in new or old position (Walls, ceiling, floors, etc.) in any Situation including replacement of old un serviceable fittings such as socket, elbow, tee, union,reducer socket,tee reducer etc. complete all as specified and directed by Engineer-in-Charge. |
| 30 | Taking up or down unserviceable Steel Water Tubing 20mm bore(dia) in any situation, with Fittings and Connections, such as socket, elbow, tee, union,reducer socket,tee reducer etc, complete all as specified and directed by Engineer-in-Charge. |
| 31 | S&F Galvanised Steel Water Tubing 20 mm Bore (dia), ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situ-ation such as socket, elbow, tee, union,reducer socket,tee reducer etc., complete all as specified and directed by Engineer-in-Charge. |
| 32 | S&F in repair 25 mm Bore gun metalGlobe/Gate valves with iron wheel/Lever half turn fixed-in-repairs. complete all as specified and directed by Engineer-in-Charge. |
| 33 | S&F in repair 32 mm Bore gun metalGlobe/Gate valves with iron wheel/Lever half turn fixed-in-repairs complete all as specified and directed by Engineer-in-Charge. |
| 34 | S&F in repair 80mm Bore gun metalGlobe/Gate valves with iron wheel/Lever half turn fixed-in-repairs complete all as specified and directed by Engineer-in-Charge. |
| 35 | S&F in repair 20 mm Bore gun metalGlobe/Gate valves with iron wheel/Lever half turn fixed-in-repairs complete all as specified and directed by Engineer-in-Charge. |
| 36 | Taking down and refixing of old 25 mm Bore gun metalGlobe/Gate valves with iron wheel/Lever half turn fixed-in-repairs complete all as specified and directed by Engineer-in-Charge |
| 37 | Taking down and refixing of old 32 mm Bore gun metalGlobe/Gate valves with iron wheel/Lever half turn fixed-in-repairs complete all as specified and as directed by Engineer in charge. |
| 38 | Taking down and refixing of old 80mm Bore gun metalGlobe/Gate valves with iron wheel/Lever half turn fixed-in-repairs complete all as specified and directed by Engineer-in-Charge. |
| 39 | Taking down and refixing of old 20mm Bore gun metalGlobe/Gate valves with iron wheel/Lever half turn fixed-in-repairs complete all as specified and directed by Engineer-in-Charge. |
| 40 | S&F 110/75 mm dia PVC SWR pipe laid to wall and floor and fixed with clamp and icluding dismantling of old existing PVC/CI/concrete pipes of any description, jointed in cement mortar(any description) and removing to store. complete all as specified and directed by Engineer-in-Charge. |
| 41 | S&F in repair 110/75 mm dia PVC SWR Bend complete all as specified and directed by Engineer-in-Charge. |
| 42 | Dismantling structural steel work incl. steel door,gate,window guard bars,grills etc. complete all as specified and directed by Engineer-in-Charge. |
| 43 | M&L fabricated frame work as in doors of gate of angle iron or other section with gusset plate rails, braces etc. having Fe-290(Gde E-165) ,complete drilled for fixing steel sheeting or other covering door etc to be prepared for hanging with and including hinges . complete all as specified and directed by Engineer-in-Charge. |
| 44 | Taking down door / window shutter with/without frame of area exc 1.50 but n exc 4.0 Sqm, each and removing from site, complete all as specified and directed by Engineer-in-Charge. |
| 45 | S&F 35 mm thick factory made flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both the faces . complete all as specified and directed by Engineer-in-Charge. |
| 46 | S&F MS medium weight cold rolled butt hinge ISI Marked 100mm size, fixed with screw complete all as specified and directed by Engineer-in-Charge. |
| 47 | M&L preparation of new or previously untreated surfaces of wood of any description not otherwise described width or girth and applying two coats of synthetic enamel paint over & incl one coat of pink primer complete all as specified and as directed by Engineer in Charge. |
| 48 | M&L preparation of new or previously untreated steel surfaces of any description not otherwise described width or girth and applying two coats of synthetic enamel paint over & incl one coat of red oxide primer complete all as specified and as directed by Engineer in Charge. |
| 49 | Demolition of stone slab and tiles fixed with bedded and jointed of any description. complete all as specified and directed by Engineer-in-Charge. |
| 50 | M&L for 18-20 mm thick machine cut Kota stone slab of size 550mm x 550mm in flooring over cement screed bed 20 mm thick in CM 1:4 and jointed with gray cement slurry mix with pigment to match the shade of slab including rubbing and mirror polishing in repairs, complete all as specified and directed by Engineer-in-Charge. |
| 51 | Demolition of reinforced cement concrete including all quoins, arches, slab, etc. complete all as specified and directed by Engineer-in-Charge. |
| 52 | Material and labour precast RCC 1:2:4 as in cover slabs,shelves and similar work type B1 using 20 mm graded stone agg etc. and set in Cm 1:4 incl forms work complete all as specified and directed by Engineer-in-Charge. |
| 53 | Material and labourfor TMT bar upto & including 10 mm dia and over cut to length bent to shape required including cranking bending, spirally hooping spirally for hooking for columns hooking ends and binding with mild steel wire annealed not less than 0.9 mm dia or securing with clips quality conforming to Fe-410-S or Fe-410-0 complete all as specified and directed by Engineer-in-Charge. |
| 54 | Removing dismantled material from site and depositing outside of Mod land exc 10 km n.exc 15km as per NGT norms. Note :- 1)Searching of Place of Disposal out side the MOD Land will be the responsibility of Contractor and rate of any distance shall be included in quoted unit rate. complete all as specified and directed by Engineer-in-Charge Please Enable Macros to View BoQ information |
| 55 | Removing dismantled material from site and depositing outside of Mod land exc 10 km n.exc 15km as per NGT norms. Note :- 1)Searching of Place of Disposal out side the MOD Land will be the responsibility of Contractor and rate of any distance shall be included in quoted unit rate. complete all as specified and directed by Engineer-in-Charge Please Enable Macros to View BoQ information |