| 1 | Taking down cement plaster on brick work of any description including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and as directed. |
| 2 | M&L for 15mm thick plaster of cement mortar (1:4)rendering on fair faces of brick work or concrete surfaces in two layer (10mm & 5mm( mixed as per manufracturer instruction waterproofing compound finishing the surface even & smooth without using extra cement complete all as specified and as directed.(Note- WPC shall be measured and paid separately) |
| 3 | M&L 15mm thick rendering in cement mortar 1:6 on fair face of brick work or concrete surface finished fair and even complete all as specified and as directed. |
| 4 | M&L for rendering 5mm thick plastering in cement mortar (1:3) on ceiling , soffits of slabs, chajjas , columns and beams etc and finished the plastered surface even and smooth without using extra cement complete all as specified and as directed. |
| 5 | Supply only integral water proofing compound conforming to IS : 2645-1975 specification complete all as specified and as directed. |
| 6 | M&L for preparation of newly plastered surfaces of walls and applying one coat of wall care white putty and sand papering surfaces to achieve smooth surfaces and applying acrylic based distemper emulsion, two coats, white or any tinted over a coat of alkaline resistant primer including washing floors, cleaning glass, joinery, electrical fittings, wiring etc. of drops and splashes complete all as specified and as directed. |
| 7 | M&L for preparation of old decorated distempered surfaces of walls by washing, rubbing down and stopping of distempered and painted surfaces and distempering walls by applying one coat of acrylic based distemper emulsion of any tint/shade including wall putty/white cement wherever required to fill the wall cracks/holes complete all as specified and as directed complete all as specified and as directed. |
| 8 | M&L Preparation of new surfaces plastered or unplastered and applying three coat of white wash on wall complete all as specified and as directed. |
| 9 | M&L Preparation of old decorated surfaces plastered or unplastered wall and applying two coat of white wash complete all as specified and as directed. |
| 10 | M&L for preparation of newly plastered surfaces on wall/ceiling/ chajjas and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 Ltre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm as per the manufacturer instruction complete all as specified and as directed. |
| 11 | M&L for complete removal of existing treatment of old decorated treatment on wall/ceiling/chaijas by scrapping make the surface free from dust, loose paints etc. or equivalent makes viz Xpress sanding machine having sanction vacuum bag or by manual scrapping and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/old surfaces as per the manufacturer instruction complete all as specified and as directed. |
| 12 | M&L for preparation of newly plastered or unplastered surfaces of ceilings and applying three coats of white wash including washing floors, cleaning glass, joinery, electrical fittings, wiring etc. of drops and splashes complete all as specified and as directed. |
| 13 | M&L for preparation of old plastered or unplastered surfaces of ceiling by brooming down or steel wire brushing: scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying two coats of white wash on old decorated surfaces of ceiling including washing floors, cleaning glass, joinery, electrical fittings, wiring etc. of drops and splashes complete all as specified and as directed. |
| 14 | Dismantling wrought iron or mild steel work of any description not other wise provided complete all as specified and as directed. |
| 15 | S&F steel work in tubular trusses MS pipes in vertical column, rafter, parlins complete using ERW or induction butt welded tubes conforming to IS-1161 of 1979 or IS-4923 of 1968 grade st 240 with one shop coat complete all as specified and as directed. |
| 16 | Dismantling Plain or corrugated sasbestose sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 17 | S&F Pre-painted galvalume aluminum zinc coating Gl based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed. |
| 18 | S&F Pre-painted galvalume aluminum zinc coating Gl based plan steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 19 | M&L for preparation of new of previously untreated steel and iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 20 | Taking up or down steel tubing and connections of 15 mm bore complete all as specified and as directed. |
| 21 | S&F of Tubes, medium grade, 15mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed. |
| 22 | Refixing of old steel tubing and conections in new or old position (wall, ceiling, floors, etc) including necessary cleaning of 15 mm bore complete all as specified and as directed. (serviceable pipe obtained from item No 20 have-in-before |
| 23 | Taking up or down steel tubing and connections of 20 mm bore complete all as specified and as directed. |
| 24 | S&F of Tubes, medium grade, 20 mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed. |
| 25 | Refixing of old steel tubing and conections in new or old position (wall, ceiling, floors, etc) including necessary cleaning of 20 mm bore complete all as specified and as directed (serviceable pipe obtained from item No 25 have-in-before. |
| 26 | Disconnecting existing tanks of capacity exceeding 500 Itrs and n.exceeding 1000 ltrs setting a side (or lowering if required for repairs, cleaning etc re connecting and refixing in same position after completion of roof treatment complete all as specified and as directed. |
| 27 | Demolition of cement concrete (un-reinforced) of any description and in any position complete all as specified and as directed. |
| 28 | M&L for PCC type B1 1:2:4 (using 20 mm stone aggregate) in water tank plateform, flooring etc complete all as specified and as directed. |
| 29 | Dismantling water tank exc 500 & n.exc 1000 ltr capacity complete all as specified and as directed. |
| 30 | S&F 1000 Itrs capacity rotaional moulded polythelene water storage(cylindrical vertical with closed top) hoisted and fixed in positions including necessary fittings all specified in SSR Part I complete all as specified and as directed. |
| 31 | Dismantling water tank n.exc 500 & n.exc 1000 ltr capacity complete all as specified and as directed. |
| 32 | S&F 500 Itrs capacity rotaional moulded polythelene water storage (cylindrical vertical with closed top) hoisted and fixed in positions including necessary fittings all specified in SSR Part I complete all as specified and as directed. |
| 33 | M&L cleaning of PVC over head tank of capacity exc 500 ltr but not exc 1000 ltr (double or triple storey building) and getting out/taking out and removing the accumulated other foreign /foul material etc (solid/semi solid) removing the same including writing the date of cleaning in tank surface by white paint complete and as specified and as directed. |
| 34 | M&L cleaning of PVC over head tank of capacity n exc 500 Itr (double or triple storey building) and getting out/taking out and removing the accumulated other foreign /foul material etc (solid/semi solid) removing the same including writing the date of cleaning in tank surface by white paint complete all as specified and as directed. |
| 35 | Taking down tarfelt with cement plaster/PCC from roof surfaces and lowering and removing the same to a from the site roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed. |
| 36 | M&L for 10 mm thick Screed bed or bedding layers in CM 1:4 in order to maintain proper slope over Existing roof surface for applying single component acrylic polymer modified/APP Membrane with water proofing compound as per manufracturer instruction finished even and smooth with out using Extra cement complete all as specified and as directed (Note: - WPC shall be measured and paid separately) |
| 37 | M&L for cutting out cracks to \\"V\\" section (shape) in existing roof slab terracing cleaning out and filling solidely with a hot bitumen and clean dry sand mortar (1:1) complete all as specified and as directed. |
| 38 | M&L for water proofing treatment to RCC roof slab including parapet comprising of the following course treatment/specified from bottom to top (a) Applying bituminous primer @0.4 Itr/Sqm over plastered surfaces of roof including parapet surfaces over the priming coat laying one layer APP based polymeric membrane of approved manufacturer, 3mm thick of weight not less than 3.60 Kg /Sqm reinforced with non woven polyester fabric weight not less than 160 gms/Sqm Edges of APP membren shall be inserted to vertical surfaces of wall as per per relevent IS or as per manufacturer instructions polymeric membrane shall be taken to a height of 60 cm(minimun) and then inserted in side the groove of parapet wall and shall be finished by a membrance flashing (B) Application of Two coat of bituminous aluminium paint over the polymeric membrane after necessary preparation and cleaning complete and as specified and as directed. |
| 39 | M&L for providing and applying single component acrylic polymer modified, fibre reinforced waterproof coating Roof Guard in 4 coats of application (a) applying primer coat with Primer @ 0.3 kg /sqm (b) over priming coat applying roof guard as specified below or manufacturer instructions with fibre reinforcement a length of approx 1m @ 0.75kg/sqm on the flat or vertical surfaces over parapetwall and ensure that there are no bubbles of creases. Overlapping of the fibre is a minimum of 50mm and allow this coat to dry for a period of 2-6 hrs depending on the atmospheric condition. (c) Applying second coat of roof guard @0.75Kg/sqm (d) Applying final coat of primer @ 0.08kg/sqm after 2nd coat has dried properly. (Note Water Proffing treatment shall be carried out by authorised applicator approved by the manufacturer.) |
| 40 | S&F in repair 20 mm dia PVC ball cock (PVC float valves) complete high pressure with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut complete all as specified and as directed. |
| 41 | Taking down or demolition and breaking up drain / Rain water pipes pipes (SGW,AC, PVC SWR)75/100 mm dia complete all as specified and as directed. |
| 42 | S&F 75 mm PVC(SWR) pipe socketed in any length with rubber ring joints, fixed to wall or in floors complete all as specified and as directed |
| 43 | S&F 110 mm bore PVC (SWR) pipes single sockets in any length with rubber ring joints fixed to wall or laid in floor complete all as specified and as directed. |
| 44 | S&F PVC(SWR) 75mm bore bends complete all as specified and as directed. |
| 45 | S&F PVC(SWR) 110 mm bore bends complete all as specified and as directed. |
| 46 | S&F PVC(SWR) 110 mm bore junction single, (Single T) equal or unequal with access door complete all as specified and as directed. |
| 47 | S&F PVC(SWR) 75 mm bore junction single, (Single T) equal or unequal with access door complete all as specified and as directed. |
| 48 | S&F PVC(SWR) 110 mm bore branch piece, double(doubleY) equal or un equal with access door coomplete all as specified and as directed. |
| 49 | Taking down eaves gutters gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan- necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories complete all as specified and as directed. |
| 50 | S & F Eaves gutters PVC pipes (160mm size or pattern), including all fittings, heads, shoes, brackets, (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed. |
| 51 | S & F Eaves gutters PVC bend (160mm size or pattern) dimenishing pieces or tapers complete all as specified and as directed. |
| 52 | S&F Mild steel sheet eaves gutters, galvanised class 3 thickness 1 mm thick 150 mm dia, half round with rounded edges complete all as specified and as directed. |
| 53 | S&F Mild steel Angles (internal or external) or nozzle pieces (Out lets)1 mm thick 150 mm dia, half round with rounded edges complete all as specified and as directed. |
| 54 | S&F Mild steel Drop ends (for spigot or socket ends) or nozzles 1 mm thick 150 mm dia, half round with rounded edges complete all as specified and as directed. |
| 55 | S&F Mild steel Stop ends (for spigot or socket ends) 1 mm thick 150 mm dia, half round with rounded edges complete all as specified and as directed. Please Enable Macros to View BoQ information |