| 1 | Sch 'A' Part-I (Building Work)DESIGN AND CONSTRUCTION OF PROVISION OF 24 X MD ACCN FOR MAJ AND ABOVE UP TO BIRG, 24 JCO’S AND 104 OR’S MD ACCN EXCLUDING INTERNAL AND EXTERNAL SERVICES AT TWO POCKETS AT NEW CANTT PRAYAGRAJ ON ENGINEERING, PROCUREMENT AND CONSTRUCTION (EPC) MODE COMPLETE AS DETAILED IN SCOPE OF WORK AND OTHER DOCUMENTS OF TENDER. |
| 2 | Total amount of Sch 'A' Part II (Site clearance, excavation and earth work) |
| 3 | Total amount of Sch 'A' Part III (Internal Water Supply ) |
| 4 | Total amount of Sch 'A' Part IV (Internal Electrification) |
| 5 | Total amount of Sch 'A' Part V (Road, Path, Culvert) |
| 6 | Total amount of Sch 'A' Part VI (Area Drainage) |
| 7 | Total amount of Sch 'A' Part VII (Sewage Disposal) |
| 8 | Total amount of Sch 'A' Part VIII (RCC security wall, compound/boundary wall fencing and gate |
| 9 | Total amount of Sch 'A' Part IX (External Water Supply ) |
| 10 | Total amount of Sch 'A' Part X (External Electrification ) |
| 11 | Total amount of Sch 'A' Part XI (DG Sets) |
| 12 | Total amount of Sch 'A' Part XII (Lifts) |
| 13 | Total amount of Sch 'A' Part XIII (Fire Fighting And Alarm System) |
| 14 | Total amount of Sch 'A' Part XIV (Lightning Protection ) |
| 15 | Total amount of Sch 'A' Part XV (Geysers) |
| 16 | Total amount of Sch 'A' Part XVI (Rain Water Harvesting) |
| 17 | Total amount of Sch 'A' Part XVII (Demolition of Buildings) |
| 18 | Sch 'A' Part - XVIII (Miscellaneous Items for B/R & E/M Works)Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as \\"Rs 0.00 under col.5 siginifies this fact only. |
| 19 | Internal Water SupplyS&F two way bib cock/ angle valve, cast copper alloy, chromium plated with crutch or butterfly handles screwed for iron pipe or for brass ferrule 15 mm bore complete all as specified and directed. |
| 20 | INTERNAL ELECTRIFICATIONM&L for Point wiring complete for One light/ceiling fan/Exhaust fan point controlled by one way switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core cable including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 25 mm in roof /floor suitable for modular switch with suitable size modular metal flush box not less than 1.20mm thick with inner and outer cover plate & frame etc of required colour complete, including PVC insulated multistanded ISI marked unsheathed FRLSH cable 1100 volts grade of size 1.50 sqmm single core FRLSH copper conductor cable as earth wire connected to common earth dolly etc. complete all as specified and directed.Note :-(a) Colour code of cable Phase-Red, Neutral- Black and Earth-Green. (b) All switch of security light should be near stair case front side. |
| 21 | M&L for Point wiring complete for One bell point controlled by one bell push 6 Amp with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core cable including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 25 mm in roof /floor suitable for modular switch with suitable size modular metal flush box not less than 1.20mm thick with inner and outer cover plate & frame etc of required colour complete, including PVC insulated multistanded ISI marked unsheathed FRLSH cable 1100 volts grade of size 1.50 sqmm single core FRLSH copper conductor cable as earth wire connected to common earth dolly etc. complete all as specified and directed.Note :-(a) Colour code of cable Phase-Red, Neutral- Black and Earth-Green. |
| 22 | M&L for Point wiring complete for One 5 pin 5 Amp switch socket outlet point on independent board with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core cable including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 25 mm in roof /floor suitable for modular switch with suitable size modular metal flush box not less than 1.20mm thick with inner and outer cover plate & frame etc of required colour complete, including PVC insulated multistanded ISI marked unsheathed FRLSH cable 1100 volts grade of size 1.50 sqmm single core FRLSH copper conductor cable as earth wire connected to common earth dolly etc. complete all as specified and directed.Note :-(a) Colour code of cable Phase-Red, Neutral- Black and Earth-Green. (b) Height of socket should be 1.20 m above from floor. |
| 23 | M&L for Point wiring complete for One light point controlled by two way switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core cable including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 25 mm in roof /floor suitable for modular switch with suitable size modular metal flush box not less than 1.20mm thick with inner and outer cover plate & frame etc of required colour complete, including PVC insulated multistanded ISI marked unsheathed FRLSH cable 1100 volts grade of size 1.50 sqmm single core FRLSH copper conductor cable as earth wire connected to common earth dolly etc. complete all as specified and directed.Note :-(a) Colour code of cable Phase-Red, Neutral- Black and Earth-Green. |
| 24 | M&L for Point wiring complete for Power point controlled by one switch with PVC insualted and unsheathed FRLSH cable 2.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core cable including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 25 mm in roof /floor suitable for modular switch with suitable size modular metal flush box not less than 1.20mm thick with inner and outer cover plate & frame etc of required colour complete, including PVC insulated multistanded ISI marked unsheathed FRLSH cable 1100 volts grade of size 2.50 sqmm single core FRLSH copper conductor cable as earth wire connected to common earth dolly etc. complete all as specified and directed.Note :-(a) Colour code of cable Phase-Red, Neutral- Black and Earth-Green. |
| 25 | S&F MCCB VTPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suit-able size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabri-cated, powder coated complete with out MCCB 4 pole 160 Amp, 16 KA capacity and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed. |
| 26 | S&F MCCB of rating 200 Amp, 4 pole, 415 Volts AC fixed type with breaking capacity 25 KA DPX3 200 type as per ICE-60947-1 ics 100% of Icu, Adjustable tripping 0-0.3-1-3s with adjustable 70% to 100% and thermal magnetic release to be fixed in existing panel complete all as specified and directed . |
| 27 | S&F MCCB of rating 160 Amp, 4 pole, 415 Volts AC fixed type with breaking capacity 25 KA DPX3 160 type as per ICE-60947-1 ics 100% of Icu, Adjustable tripping 0-0.3-1-3s with adjustable 70% to 100% and thermal magnetic release to be fixed in existing panel complete all as specified and directed . |
| 28 | S&F MCCB of rating 125 Amp, 4 pole, 415 Volts AC fixed type with breaking capacity 25 KA DPX3 160 type as per ICE-60947-1 ics 100% of Icu, Adjustable tripping 0-0.3-1-3s with adjustable 70% to 100% and thermal magnetic release to be fixed in existing panel complete all as specified and directed . |
| 29 | S&F modular PVC box with 20 Amp MCB SP including 16 Amp Modular Top plug complete all as specified and directed. Note: This item is catered for connection of AC/Geyser. |
| 30 | CHIMENYSupply and fixing testing, commissioning of electric chimney for kitchen with stainless steel sheet with filter less , heat auto clean of robust operation including Al ducting, angle frame, threading rods, nut bolts along with controlling dampers Nos and suitable blower motor of suitable size having 1500 M3/Hrs controlling/display panel with auto clean facility system including Cable PVC insulated sheathed LT 1100 V grade with copper conductor of size 3 core 10 sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable clamps spacers bolts nuts etc complete all as specified and as directed. Make FABER Model No. HOOD IRIS BLDC FL HC BK 60 or equivalent as approved by GE. |
| 31 | Supply and fixing testing, commissioning of Aluminum exhaust size 100 mm dia with all fittings for extension of Exhaust of Chimney, including fixing arrangement and making hole on wall to exhaust the fumes to the atmoshphere complete all as specified and directed. |
| 32 | EXTERNAL WATER SUPPLYExcavation in hard standing for crossing the road as per the authorized width for tak-ing out/laying/cleaning/repairing of CI/GI pipe lines all as directed including making good the road cut to match with the existing surface either with bituminous macadam or with PCC 1:2:4, type B-2 (using 40mm graded crushed stone aggregate) complete all as specified and directed. |
| 33 | M&L for laying, jointing and testing Ductile iron pipe 100mm bore Class 'K-7' with socket and in and including spigot ends centrifugally cast, suitable for tyton type joints, in any length, laid in trenches complete all as specified and directed. |
| 34 | M&L for laying, jointing and testing Ductile iron pipe 150mm bore Class 'K-7' with socket and in and including spigot ends centrifugally cast, suitable for tyton type joints, in any length, laid in trenches complete all as specified and directed. |
| 35 | M&L for laying, jointing and testing Ductile iron pipe 100mm bore Class 'K-9' flanged both ends with in and including rubber gasket ends centrifugally cast, suitable for flanged joint, in any length, laid in trenches complete all as specified and directed. |
| 36 | M&L for laying, jointing and testing Ductile iron pipe 150mm bore Class 'K-9' flanged both ends with in and including rubber gasket ends centrifugally cast, suitable for flanged joint, in any length, laid in trenches complete all as specified and directed. |
| 37 | Supply and fixing PP-R Gate valves (brass insert) of size 20 mm outer dia complete all as specified and directed. |
| 38 | Supply and fixing PP-R Gate valves (brass insert) of size 40 mm outer dia complete all as specified and directed. |
| 39 | Supply and fixing PP-R Gate valves (brass insert) of size 63 mm outer dia complete all as specified and directed. |
| 40 | Supply and fixing PP-R Gate valves (brass insert) of size 90 mm outer dia complete all as specified and directed. |
| 41 | Construction of fly ash brick masonry valve pit chamber of size 900 mm X 900 mm X 900 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed. |
| 42 | Construction of fly ash brick masonry valve pit chamber of size 600 mm X 600 mm X 600 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed. |
| 43 | Construction of fly ash brick masonry valve pit chamber of size 450 mm X 450 mm X 450 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed. |
| 44 | Supply and fixing Foot Valve conforming to IS 4038, 100 mm (4”) dia complete all as specified and directed. . |
| 45 | EXTERNAL ELECTRIFICATIONSupply, install, connecting, testing and commissioning of outdoor type, Transformer 315 KVA capacity step down IS -1180 Part I/2014 (revised) latest amendment in Mar 2021, amendment No. 1,2,3&4 in SSR Part -I.( Energy efficiency level -3) BEE Star rated energy saving with dual ratio on HT side 11/0.433 KV at no load, 3 phase , 4 wire AC, 50 Hz, AC double core type copper wound ,oil immersed ,air natural oil natural cooled with external cooling tubes ,transformer delta connection on HV Side and star connection on LV side in accordance with vector symbol DYN-II with neutral brought out on secondary side and having tapping in step of + 7.5% step of 2.5% each to be changed by means of hand operated off load tap changing gear arrangement including first fill of transformer oil as per IS -335 and including all fitting /accessories as specified. Transformer should have cable box on LT side and brass bushing on HT side ,oil temperature gauge ,dehydrating breather with first fill of dehydrating silica gel ,oil conservator tank ,explosion vent ,rating and terminal marking plate, oil level gauge ,oil drain and filter valve ,independent earth point and neutral fittings ,earth terminal at body base ,voltage regulation should be as per IS and limit of temp rise after continuous full load run as specified in SSR part -I and IS - 1180 Part I (revised) shall be stand by adjusted to suit the maximum ambient temp prevailing at site all as specified comprising with the following specification :- accepting officer to check the above system. |
| 46 | (a) Oil conservator with filling hole and cap with drain plug. (b) Silica gel breather with oil seal and first filling of dehydrating agent.(c) Pressure release valve with automatic resetting arr4engement after release of pressure- 01 set(d) Oil temperature gauge (indicator) having range (0-120 degree Centigrade)with max reading pointer 100 mm dia with shut off valve between the conservator and main tank.(e) Adequate No of Thermometer pocket including one No for accommodating bulb type Thermometer.(f) Drain cum bottel filter valve.(g) Top filter valve.(h) Prismatic oil level gauge.(j) Inspection cover(k) Cover lifting Lugs.(l) Jaking and lifting lugs(m) Bi directional plain rollers -04 Nos.(n) Rating and diagram plate.(o) Separate neutral bushing brought out for earthing on LV side.(p) First filling of transformer oil conforming to IS 335-1972 with latest amendments. (q) One No Air insulated cable box on HV side suitable for XLPE cable (r ) Air insulated plain bus bar terminals for bus connection including jointing materials.(t) Earthing terminals -02 nos located on diagonally opposite transformer tank base.(u) Copper alloy termination studs for connecting cables at HV and LV sides. |
| 47 | Supply, installation, testing and commissioning of 200 KVAR rated capacity automatic power factor controller (APFC) system of ready to use conforming to IS : 8623 and suitable for 415 V, 3 Phase, 50 Hz AC and housed in elegant, fabricated from minimum 2.00 mm thick CRCA sheet with anti-corrosive coating and finally powder coated in texture RAL 7032 and consisting of the following:- (a) Three phase & neutral, aluminiun bus bar having current carrying capacity 300 Amps of suitable size including bus bar epoxy insulators and heat shrinkable PVC sleeve to differentiate the three phase.(b) A set of heavy duty capacitor Nos of 50 KVAR, 2 No. 2 Nos of 25 KVAR, and 4 Nos. 12.5 KVAR, type MPP-H by using metalised polypropylene technology having total losses less than 0.5 W/KVAR, high overload and frequent switching capability conforming to IS: 2834, IEC 831 capacitors should provided with special sequential pressure sensitive disconnector. (c) TP ACB 630 Amps 50 KA load adjustable 70% to 100% thermal setting conforming to IS: 13943 to ensure positive isolation with suitable terminations. |
| 48 | Supply, installation, testing and commissioning of HT 11 KV , 3 phase , 3 wire totally enclosed metal clad extensible type outdoor , floor mounted horizontal drawn out , vertical isolation type vacuum circuit breaker of ca-pacity 630 amps , motor operated , spring charged having rupturing capaci-ty of 350 MVA and including suitable batteries for DC 24 volt(12X2 volts,90AH batteries) consists of the following description for each HT pan-el and interlocking arrangement(a) Housing for circuit breaker carriage - 01 No(b)Mechanical inter locking and automatic safety shutter gear including pad locking arrangement- 01No(c ) isolating plugs - 06 Nos(d) 01 N 18.5 KA at 11 KV , 630 amps VCB comprising of the following :-(i) Assembly of 3 vacuum interrupters complete with epoxy support insu-lator and self aligning finger type isolating contacts(h) 01 Nos 3 phase horizontal draw out type potential transformer 100 KV burden and accuracy mounted on drawable housing for 11 KV 110 volt with protection fuse complete. (j) Rear cable termination provision for terminating 3 core up to 120 sq mm XLPE cable (k) Digital Ampere meter dual range with selector switch 0-200/ 100/5 amps (l) Digital Volt meter with selector switch 0-15 KV (m) triple pole non directional IDMT relay having minimum 02 element for over current setting 50 % - 200 % and one element for earth fault protec-tion setting 20 % - 80 % with instantaneous high set element with Current transformer -(03 set)- 01No.(n) On/Off/Trip indication -01 No(o) TNC switch - 01 No(p) Trip circuit helthy indication lamp with push button - 01 No(q) 3 phase RYB indication with lamp & holder - 01 set(r) Cable glands of suitable size(s) In built integral earthing(t) Common bus bar having 630 amps capacity with enclosure |
| 49 | Supply and erecting two poles structure with 02 Nos of Steel tubular pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 type 11 M long conforming to IS complete with bolts, nut, & screw all as specified and directed.(a) Excavation in trenches not exceeding 1.5meter wide and 2.0 M deep for pole foundation and getting out in soft loose soil, returning filling in the excavated of the soil after fixing the pole in foundation ramming earth around in layer not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 meters.(b) M& L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate ) n foundation 900mm x 600 mm cross section and painting depth 1.5 metre for concrete in casing the pole upto GL all as directed. (c) M& L for providing PCC (1:3:6) type C2 ( using 40mm graded stone aggregate ) for plinth block /collar above GI 2000 mm high and 450 mm dia all a directed and specified.(d) M& L for painting of poles extremely with one coat of black bituminous paint (upto planting depth ) and above plinth block concrete collar with two coat of aluminium paints over a red oxide coat primer including preparation of surface including painting of 30 cm wide bands 3 Nos. with synthetic enamel paint of appropriate colour in alternate layer upto the height of 1.5 M above plinth block. |
| 50 | M&L for cutting of PCC/Hard standing/WBM road not exceeding 30 cm in width not exceeding 60 cm in depth for passing of HT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 using 20 mm graded stone aggregate complete all as specified and directed. Please Enable Macros to View BoQ information |
| 51 | M&L for cutting of PCC/Hard standing/WBM road not exceeding 30 cm in width not exceeding 60 cm in depth for passing of HT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 using 20 mm graded stone aggregate complete all as specified and directed. Please Enable Macros to View BoQ information |