| 1 | M&L surface dressing not exc. 15cm deep in soft and loose soil, complete all as specified and directed. |
| 2 | M&L for forming embankments including raising earth, spreading in layers not exc. 30cm thick, watering, ramming/ rolling, consolidating with power roller of 8 to 12 tonne and finishing to required size, shape etc., not exc. 1.5m high from base, complete all as specified and directed.Note :- Earth shall be obtained from borrow pits excavated within the MoD land as per the directions of Eng-in-Charge. Rate quoted shaal be deemed to include trasportation and excavation of borrow pits. |
| 3 | Excavation in trenches not exc. 1.5 m deep and not exc. 1.5 m width in soft/loose soil, complete all as specified and directed. |
| 4 | M&L PCC Type D-2, 1:4:8 using 40 mm aggregate as in foundation, complete all as specified and directed. |
| 5 | Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 6 | Returning filling in with approved excavated soil including spreading, levelling in layers not exc. 25cm thick, complete all as specified and directed. |
| 7 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed. |
| 8 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and directed. |
| 9 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 10 | All as per item No 09 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders. |
| 11 | M&L for RCC design mix M-25 (using 20mm graded stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 12 | M&L Brickwork with Fly Ash bricks (Old size), straight or curved on plan exc. 6m mean radius built in 1:6 cement mortar complete all as specified & directed. |
| 13 | Rendering 5mm thick in cement mortar 1:4 on fair faces of brick/concrete surface finished fair and even complete all as specified and directed. |
| 14 | M&L for rendering 15 mm thick on fair faces of brick work in CM in 1:4 finished even and fair and mixing with water proofing liquid as per manufacturer instruction (but excluding the cost of water proofing liquid ) external surface, complete all as specified and directed. |
| 15 | Supply only Integral crystalline water proofing compound, complete all as specified and directed. |
| 16 | M&L for preparation of new plastered and primed surface and applying two coats of interior acrylic emulsion on walls, complete all as specified and directed. |
| 17 | M&L for two coats of water based premium acrylic smooth exterior emulsion of approved colour with silicon addictive & colour stay technology excellent dirt pick up resistance with low VOC less than 50 gram/ltr as per the LEEDS specification anti algal propertiess in two coats @ 1.79 ltrs (undiluted)/10sq mtrs diluted with water as per manufacturer instructions complete all as specified and directed. |
| 18 | M&L for 1mm thick wall care putty with one coat of acrylic water based exterior / interior grade primer @0.9 ltrs (undiluted)/10sq mtrs diluted with water 1:1 ratio. Allow 6-8 hrs to dry the surface for painting of subsequent coats, complete all as specified and directed |
| 19 | S&F mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel, hollow or flat sections) including distance pieces, cleats etc. conforming to Fe-410-W (Gde E-250) quality A, including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 20 | S&F Pre-painted galvalume aluminium zinc coting GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws ,complete all as specified and directed |
| 21 | S&F Pre-painted galvalume aluminium zinc coting GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed |
| 22 | S&F translucent polycarbonate corrugated roofing sheet, coloured, 3 mm thick as in roof covering/ cladding to wall, fixed with screws, complete all as specified and directed. |
| 23 | M&L for machine cut kota stone slab 16-18 mm thick (pre polished) laid and jointed with grey cement slurry mixed with pigments to match the shade of stone in flooring over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed |
| 24 | M&L for hardcore of broken stone or boulder of gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15cm thick, watered and rammed/ consoldating with power roller of 8 to 12 tonne to a true surface, complete all as specified and directed. |
| 25 | M&L for 100 mm thick cement concrete 1:2:4 type B-2 using 40 mm graded aggregate as in sub base, sub floor, floors etc. complete all as specified and directed. |
| 26 | M&L for 75 mm thick PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in plinth protection, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 27 | M&L for PCC 1:2:4 type B-1 (20mm graded stone aggregate) as in kerb around tiles and paver block slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 28 | S&F outdoor heavy duty vitrified tiles of size 600 X 600mm and 20mm thick, anti-skid, UV- resistant, exterior grade, laid over and including 75mm thick PCC M-10 (using 20mm graded stone aggregate) as base layer with 20mm thick cement mortar screed bed in CM 1:4, tiles set in cement slurry/adhesive as per manufacturer's specifications, joints filled with polymer-modified grout of matching shade, including surface preparation, cutting to size, curting and finishing complete all as specified and directed. |
| 29 | M&L for point wiring light/fan/bell point with PVC insulated FRLS unsheathed single core cable of multistranded copper conductor of size 1.5 sqmm as phase & neutral drawn in and including PVC conduit medium grade not less than 20 mm dia, ISI marked, duly concealed to wall/floor or above false ceiling of suitable size with all fitting and accessories laid on wall/ceiling alongwith 1.5 sqmm stranded PVC insulated FRLS unsheathed copper conductor(Green in color) as earth wire and connected to common earth dolly for the following incl making good to surface with CM(1:4) plaster and paint to match the surface complete incl provn of electrogalvanised steel terminal switch boxes of suitable thickness and white bakelite plastic laminated top sheet cover and fixed with brass screws cup washer for fixing switches/socket/regulators etc complete all as specified and directed. |
| 30 | All as per item No. 29 above but for on independent board with cables of size 4 sqmm. |
| 31 | S&F switch Piano Flush button single pole one way 5 Amp complete all as specified and directed. |
| 32 | S&F switch piano flush single pole one way 15/16 Amps complete all as specified and directed. |
| 33 | S&F socket outlet flush type 5/6 pin 15 Amps 230V AC complete all as specified and directed. |
| 34 | M&L for ceiling rose 3 terminal / PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 35 | S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 36 | S&F MCB DB SPN 4 way with 100 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and directed. |
| 37 | S&F MCB DB SPN 8 way with 100 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and directed. |
| 38 | S&F MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified and directed. |
| 39 | S&F MCB, SPN, AC, 240 volts of 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 40 | S&F LED bldg light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 41 | S&F sub main wiring with two single core FRLS PVC insulated unsheathed multistranded copper conductor of size 6 Sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area FR PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including 20mm dia 'medium grade' PVC concealed conduits and fittings, complete all as specified and directed.NOTE: One unit length shall measured as two run of main wire and one run of conduit & earth wire |
| 42 | Supply, laying in trenches, connecting and testing LT UG cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm x 2 core complete all as specified and directed. |
| 43 | S & F bore steel tubing galvanised “Light Grade” of 32mm on Wall for protection of cables, complete all as specified and directed. |
| 44 | M&L for earthing complete with galvanished steel earth plate electrode 600x600x6.0 mm thick buried directly in ground and earth pit not less than 2.25 mtr deep below NGL and top edge of the plate not less than 1.5 Mtr deep below NGL, surrounded with adequate qty of char coal dust mixed with salt to a packed thickness not less than 15 Cm on all sides of earth plate incl excavation, earth work, returning filling in , removal of surplus soil to a distance in n.exc. 50 mtr incl GI wire 4mm dia nut bolts etc to earth plate one end connected to continuous earth wire incl GI pipe watering light grade with CI funnel and wire mesh and PCC 1:2:4 type B-1 as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1 duly re-enforced with MS bar 6mm dia @ 150mm C/C both ways with 10mm dia MS bar lifting handles, all as described in electric plate No. 3 of SSR part-I complete all as specified and directed. Please Enable Macros to View BoQ information |