| 1 | Taking down existing water proofing treatment of any description incl PCC padding,/ or cement plastering work any thickness from roof surfaces, cleaning of roof and prepairing it for further treatment incl make good necessary dubbing out wherever required and removing rubbish from site complete all as specified and directed. |
| 2 | Material and Labour for Brushing neat cement slurry with 3.0 kg of cement per sq. metre complete all as specified and as directed. |
| 3 | Matrial and Labour for Cement Concrete 1:2:4 Type B-0 (12.50 mm Graded Stone aggregate in padding, finishing surface concrete topping even and fair (without using extra cement) of average thickness 40 mm in slope as required over roof complete all as specified and as directed. |
| 4 | Material and Labour for 10 mm thick Plastering in CM 1:4 on concrete roof surfaces using water proofing compound @ 3% by weight of cement and finishing the surface even and fair complete all as specified and directed. (Note: WPC will be measured separately) |
| 5 | Supply only liquid waterproofing compound ISI Marked complete all as specified and directed. |
| 6 | Material and Labour for Applying evenly two coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m incl cleaning surface complete all as specified and as directed. |
| 7 | Material and Labour for APP based polymeric membrane( plain /gravel ) minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application ,The overlaps while torching shall be 100 mm in both directions(longititudinal and transverse directions). All overlap joints shall be sealed throughly by thermofusing both the membrene layers and sealing it with the help of hot trowel. The overlap joints shall be made as monolithic layer complete all as specified and directed. |
| 8 | M & L for precast machine pressed cement concrete tiles with grey cement and no pigments of size 250 x 250 x 20-22mm thick conforming to IS 1237-1980 set in cement slurry laid jointed and pointed in neat cement slurry including bedding layer of 15mm thick screed in CM 1:4 complete all as specified and directed. |
| 9 | M/L for kota stone slab 20-25 mm thick in riser of steps skirting ,dado and pillar laid over cement screed and jointed with including 15mm thick screed bed in CM 1:6 etc set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed. |
| 10 | Supply and Fixing in Repair Rotational moulded polyethylene water storage tanks of capacity 500 Ltrs (Including Dismantling of Existing Tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, including making necessary arrangements for fixing inlet, outlet and overflow pipe and provision of wash out pipe etc and 20 mm ball valves High Pressure PTMT with epoxy coated aluminium rod and high density plastic ball complete all as specified and directed. |
| 11 | Supply and Fix in Repair Ball valves 20/25 mm dia high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed as approved complete all as specified and directed. |
| 12 | Supply and Fix in repair Galvanized Steel Tubes of bore 15/20 mm, 'Medium grade' galvanised, with all necessary fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 13 | Supply and Fix in repair Galvanized Steel Tubes of bore 25 mm, 'Medium grade' galvanised, with all necessary fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 14 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each and removing from site complete all as specified and directed. |
| 15 | Supply and fixing solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, complete all as shown in drawing of relevant item in MES, schedule Part-II , 2004 complete all as specified and directed. |
| 16 | Supply and fixing factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as shown in drawing of relevant item in MES, schedule Part-II , 2004 complete all as specified and directed. |
| 17 | Supply and fixing Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified and directed. |
| 18 | Supply and fixing aluminium handles extruded type of size 125mm, complete all as specified and directed. |
| 19 | Supply and fixing 150 mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and directed. |
| 20 | Supply and fixing 250 mm long aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cost or extruded sections or cost alumminium alloy complete all as specified and directed. |
| 21 | Supply and Fix in Repairs PVC (SWR) pipes of 110 mm Dia, single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls incl all necessary fittings complete all as specified and as directed. |
| 22 | Supply and Fix in Repairs PVC (SWR) pipes of 75 mm Dia, single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls incl all necessary fittings complete all as specified and as directed. |
| 23 | S&F for Bands Straps Supports or stays for Rainwater Ventilating Pipes Including Bolts if required Hooks stay heavy for large complete all as specified and as directed. |
| 24 | Supply and Fix in Repair Gun-metal, globe or gate valves 20/25 mm, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 25 | M&L for 15 mm thick rendering in cement plaster 1:4 on fair face of brick/concrete/stone masonry surfaces including finishing the surfaces even and smooth (without using extra cement) incl mixing with integral water proofing compound complete incl Taking down cement plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and directed. Note:- Integral water proofing compound will be measured and paid separately. |
| 26 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 27 | Dismantling of stone slabs and tiles of any description or thickness in floors & aprons etc laid over bedded and pointed in any mortar complete all as specified and directed. |
| 28 | M&L for coloured tiles in vertical surface 450X300X7mm thick set and jointed over and including 10 mm thick rendering even and rough in CM 1:3 for backing of tiles, jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles complete all as specified and directed. |
| 29 | Material and labour Non skid coloured ceramic tiles 7 to 8 mm thick area of each tils exc.0.11 sqm but not exc 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15 mm thick screed bed in Cement Mortar 1:6 complete all as specified and directed |
| 30 | S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern', size 580 mm x 440 mm, white with integral foot rests, embedded and set in PCC 1:5:10 type E-2 incl flush pipe, traps etc complete fittings and making good to floor including removing rubbish complete all as specified and directed. |
| 31 | S & F in repair 10 ltrs capacity PVC low level flushing cistern, of make specified with inlet, float valve and handle including bracket with 32 mm dia PVC flush pipe complete all as specified and as directed. |
| 32 | S&F in repairs 15 mm SS Pillar taps of long body any colour high pressure screwed for iron pipe and fixed.(Minimum weight15mm-110gms) fixed complete all as specified and directed. |
| 33 | S&F in repairs Vitreous China wash basin, white, flat back, size 580x450irun (for Hospilal use) but including brackets including coupling and waste pipe and Bottle trap of PTMT and Bore 32 mm having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms) complete all as specified and directed. |
| 34 | Demolition of brick work, built in Cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 35 | M&L for brick work with fly ash bricks (modular size bricks), straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed. |
| 36 | M&L for sunken floor treatment as in following precedence (i) The treatment of existing sunken floor is to be dismantled upto full depth of Sunken RCC Slab and the surfaces both vertical and horizontal shall be cleaned by removing all loose mortar, dirt, dust etc. by chisel, hammer, wire brush/Jute Brush and Air Blower machine than apply two coats of elastomeric compound viz back bond WPC-30 over one coat on neat primer i.e. Super latex be applied on clean surface.(ii) Provide 40mm thick PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in sub base and provide 40mm dia GI pipe med gde as in (spout) of 600mm long as in sunken portion. (iii) Then rendering 15mm thick in CM 1:3 using liquid water proofing compound @ rate 200 ml per 50 Kg bag of cement on horizontal and vertical surfaces of sunken portion. Note: Water proofing compound shall be measured and paid separately. (iv) The sunken floor tested for leakage/seepage by ponding it with water for minimum 72 hrs.(v) Then fill the remaining sunken portion with PCC 1:5:10 using brick aggregates including fixing sanitary items requiring embedding in cement concrete. To ensure that there shall not be any seepage/dampness in the slab as seen underneath and side. |
| 37 | S&F in repairs Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 38 | S&F in repairs size of approx 450x600mm looking mirror approved quality with wooden back and edge beading, complete with polishing fixed with screws to wall, complete all as specified and directed. |
| 39 | S&F in repairs chromium plated/SS grating square slit 100 mm dia with or without waste hole complete all as specified and directed. |
| 40 | S&F in repairs PVC connection 15mm size with PTMT nuts of length 600 mm fixing complete all as specified and directed. |
| 41 | S&F in repair chromium plated shower roses 125 mm long with or without swivel joints, any size, including fixing fixing to steel pipe or union complete all as specified and direceted. |
| 42 | M&L PVC (SWR) floor trap plain with grating incl jointing with solvent cement 75 mm bore complete all as specified and direcetd. |
| 43 | S&F in repairs 15 mm bore stop cock,(angle valve) cast copper alloy, fancy type, chromium plated, screwed down, high pre-ssure screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 44 | S&F in repairs 15 mm bore Bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferulle and fixed complete all as specified and directed. Please Enable Macros to View BoQ information |