| 1 | =B2& \\" BoQ\\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (R&D) SECUNDERABAD Name of Work: PROVISION AND INSTALLATION OF NEW INTELLIGENT INTEGRATED FIRE DETECTION AND ALARM SYSTEM AT DRDL, HYDERABAD Contract No: CERD/SEC/TOKEN/01 OF 2026-2027 Bidder Name : PRICE SCHEDULE( This BoQ template must not be modified / replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SlNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Rate in Figures to be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes Total Amount Total Amount in Words |
| 2 | Supply, installation, testing, programming & commissioning of Computer System, i7 Processor, latest generation, 2.93GHz, 4MB Cache with 16 GB RAM, & 1 TB SSD, 2GB 4K Graphics Card, 10/100 Mbps Ethernet card, USB connection & internal modem, Microsoft(R) Windows(R) 10 OS Professional Enterprise or latest, Web server software, 100/1000 Mbps NIC for Network connection and antivirus software as per Specifications. Accessories included 50 Inch UHD 4K LED Screen, Optical Mouse & Key Pad, Windows Licensed software compatible with the above FAS System configuration complete all as specified and directed.NOTE:Fire alarm system shall be connected to a computer-based monitoring system with real-time alarm, fault display, event logging, and reporting. Complete supply, installation, configuration, testing, commissioning, and training shall be included in the contractor’s quoted rate. |
| 3 | Supply, Installation, Testing & Commissioning of scaleable & upgradeable software for Fire Alarm System with features like 3D vector dynamic graphics with AutoCAD import of plan with Zoom In & Zoom Out facility, Plant Viewer, Trend Viewer, Object Viewer, Report Viewer, Alarm router. The Web-Based Server software shall permit use of Standard Web- Browsers such as Microsoft Internet Explorer, Netscape Navigator, etc. The software shall be capable of integration third-party systems and should supports latest IP technology (IP V4/V6). The Web based software shall include Client License for remote viewing. The software shall have Online Engineering capability i.e. Zero Downtime for software graphics modification. Software should be capable to integrate BMS, Gas Suppression & VESDA Panels Seamlessly complete all as specified and directed. Software should comply to OPEN Protocols like:- BACnet/IP for HVAC Automation / BMS- SNMP for UPS & Networking Integration- Modbus/IP for Energy Monitoring- IEC61850 for Electrical & Power Integration- ONVIF for CCTV Integration- OPC for any other Integration. |
| 4 | NOTE:The project comprises multiple buildings, and each building shall be provided with a separate and dedicated 3D graphical representation on the fire alarm computer-based monitoring system. The 3D graphics shall clearly indicate building layout, floors, zones, and locations of all fire alarm devices with real-time fire, fault, and supervisory status. The contractor shall include complete development, configuration, integration, testing, and commissioning of all 3D graphics for each building within the quoted scope, without any additional cost. |
| 5 | Supplying, installation, testing and commissioning of UL 864 10th edition UL Listed and FM approved Analog addressable 2 Loop Fire Alarm Control Panel having the total panel capacity of 252 devices. The panel shall be able to give pin point location of all Fire /fault and Isolation conditions of addressable units via the address codes. The panel shall have the capacity of storing upto 10000 events. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel shall have a 2”x4-3/4” Size VGA monochrome LCD display and having maximum 320 (8 x 40) Characters in the display with optional 24 Zones LED indicators. The panel shall have a built in power supply of 170 Watts and battery charger. Battery charger shall be able to charge the system batteries of upto 33AH capacity. The Panel shall have the capacity of connecting additional 31 panels or Network terminals using network card, with redundancy in the network. The panel shall have the capacity of connecting maximum 16 Remote terminals /16 remote displays or combined by using. The panel shall be compatible for IBMS system with open protocol BACnet over IP complete all as specified and directed. |
| 6 | NOTE :All disturbed existing surfaces shall be made good after completion of works. Any damage caused during execution shall be repaired and restored by the contractor at no extra cost. |
| 7 | All as per Sl Item No 3 above but for 1 Loop Panel. |
| 8 | Supplying, installation, testing & commissioning of UL 864 10th edition UL Listed and FM approved Networkable Repeater Panel. The panel shall be able to give pin point location of all Fire /fault and Isolation conditions of addressable units via the address codes. The panel shall have the capacity of storing upto 10000 events. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel shall have a 2”x4-3/4” Size VGA monochrome LCD display and having maximum 320 (8 x 40) Characters in the display with optional 24 Zones LED indicators. The panel shall have a built in power supply of 170 Watts and battery charger. Battery charger shall be able to charge the system batteries of upto 33AH capacity. The Panel shall have the capacity of connecting additional 31 panels or Network terminals using network card, with redundancy in the network. The panel shall have the capacity of connecting maximum 16 Remote terminals /16 remote displays complete all as specified and directed.NOTE :All disturbed existing surfaces shall be made good after completion of works. Any damage caused during execution shall be repaired and restored by the contractor at no extra cost. |
| 9 | Supply, Installation, Testing & Commissioning of UL268 6th and 7th edition compliance and FM approved Intelligent Addressable multi-criteria detector (optical and thermal sensors) complete with standard base, facility to mount in different comprehensive environment, Tri-color detector-status LED with 360 ° view, microprocessor circuitry with error check; detector self-diagnostics and supervision programs, Rate-of-Rise Detection: 15°F / min. (8.3°C / min.) - Fixed: 135°F (57°C) , Field programmable as rate-of rise or fixed temperature, Polarity insensitive, Superior EMI and RFI immunity, RoHS compliant. Detector shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature in detector shall consider Isolator base in place of standard base OR separate Isolator before and after every detector to comply the same without any extra cost complete all as specified and directed.NOTE:All fire alarm detectors shall be installed on the existing POP/false ceiling without causing any damage or disturbance to the ceiling finishes. In case any damage occurs during installation, the contractor shall be fully responsible for carrying out all necessary repair and reinstatement works to restore the ceiling to its original condition at no additional cost. |
| 10 | Supply, Installation, Testing & Commissioning of UL listed and FM approved intrinsic safe Multi-criteria detector for hazardous zone along with base & line adaptor/Zener diode complete all as specified and directed.NOTE:Fire alarm detectors shall be installed on the existing POP/false ceiling without causing any damage or disturbance to the ceiling finishes. In case any damage occurs during installation, the contractor shall be fully responsible for carrying out all necessary repair and reinstatement works to restore the ceiling to its original condition at no additional cost. |
| 11 | Supply, Installation, Testing and Commissioning of response indicator having two LED, metallic cover with all connections etc complete all as specified and directed.NOTE:Response indicator shall be installed on the existing POP/false ceiling without causing any damage or disturbance to the ceiling finishes. In case any damage occurs during installation, the contractor shall be fully responsible for carrying out all necessary repair and reinstatement works to restore the ceiling to its original condition at no additional cost. |
| 12 | Supplying, installation, testing & commissioning of UL listed and FM approved Intelligent addressable Class X type (Style 7), Control Module with built in dual isolator, polarity insensitive, Tri color LED for status (Green for Normal, Yellow for Faulty and RED for activation), Operating Temp and RH: 0-49degC and <=95%. Module shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature shall provide separate Isolator before and after every Module to comply the same without any extra cost complete all as specified and directed.. |
| 13 | Supply, Installation, Testing and Commissioning of UL listed and FM approved Intelligent addressable Class X type (Style 7), Monitor Module with built in dual isolator, polarity insensitive, Tri color LED for status (Green for Normal, Yellow for Faulty and RED for activation), Operating Temp and RH: 0-49degC and <=95%. Module shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature shall provide separate Isolator before and after every Module to comply the same without any extra cost complete all as specified and directed. |
| 14 | Supplying, installation, testing & commissioning of UL listed and FM approved Intelligent addressable Class X type (Style 7), Manual Pull Station Single Action, Shock and Vibration Resistant, with built in dual isolator, polarity insensitive, Tri color LED for status (Green for Normal, Yellow for Faulty and RED for activation), T-45 Key Reset lockset for easy maintenance, Operating Temp and RH: 0-49degC and <=95%. MCP shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature shall provide separate Isolator before and after every MCP to comply the same without any extra cost complete all as specified and directed. |
| 15 | Supply, installation, testing and commissioning of addressable flame proof MCP along with all fixing accessories in complete all as specified and directed. |
| 16 | Supply, Installation, Testing & Commissioning of UL listed and FM approved Audible base with ‘low-frequency, Provides six (6) field configurable audible-tone complete all as specified and directed. |
| 17 | Supply, Installation, Testing & Commissioning of Flame proof Hooter complete all as specified and directed. |
| 18 | Supply, installation, testing and commissioning of reflective type self aligning motorized Beam detector, receiver remote LED status indicator, sensitivity measurement filters and other mounting accessories complete all as specified and directed. |
| 19 | Supply and fix Fire Alarm sounders / Sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 meter with sound output variation of + 5 DB for 1000 meter range complete all as specified and directed.NOTE for Item no 9 to 16:All disturbed existing surfaces shall be made good after completion of works. Any damage caused during execution shall be repaired and restored by the contractor at no extra cost. |
| 20 | Supply, install, testing & commissioning of ON LINE UPS 2 KVA, 3 phase input and 3 phase output, 30 min backup time 360 V including external battery cabinet 1 UPM (Uninterrupted Power Module) comprising of battery suitable for 360V / 440V and the UPS shall of key features such as: -(a) DSP Technology with IGBT based inverter.(b) Smart LCD display for real-time information.(c) CVCF (Constant Voltage Constant Frequency) operational with battery.(d) Adjustable battery in all 360V modules.(e) Immune to reverse phase sequence & no neutral operation(f) Hot standby, cold start features available.(g) Built in maintenance bypass & static bypass switches.(h) Configuration output voltage setting.(j) Input filter for power factor 0.9.(k) Conformal coated PCB assembles to with stand harsh environment.(l) Inbuilt charger of 20 Amps, parallel redundancy and battery reverse protection in all 360 Volts. |
| 21 | Supply, install, testing & commissioning of ON LINE UPS 3 KVA, 3 phase input and 3 phase output, 30 min backup time 360 V including external battery cabinet 1 UPM (Uninterrupted Power Module) comprising of battery suitable for 360V / 440V and the UPS shall of key features such as: -(a) DSP Technology with IGBT based inverter.(b) Smart LCD display for real-time information.(c) CVCF (Constant Voltage Constant Frequency) operational with battery.(d) Adjustable battery in all 360V modules.(e) Immune to reverse phase sequence & no neutral operation(f) Hot standby, cold start features available.(g) Built in maintenance bypass & static bypass switches.(h) Configuration output voltage setting.(j) Input filter for power factor 0.9.(k) Conformal coated PCB assembles to with stand harsh environment.(l) Inbuilt charger of 20 Amps, parallel redundancy and battery reverse protection in all 360 Volts. |
| 22 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath as required complete all as specified and directed.NOTE:Cable shall be installed on the existing POP/false ceiling without causing any damage or disturbance to the ceiling finishes. In case any damage occurs during installation, the contractor shall be fully responsible for carrying out all necessary repair and reinstatement works to restore the ceiling to its original condition at no additional cost. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |