| 1 | Disconnecting existing PVC water tanks exc. 250 litre and n. exc. 500 litre capacity , setting aside for treating the platform surfaces and hoisting, reconnecting and refixing in position after cleaning the tank complete all as specified & directed. |
| 2 | Disconnecting existing PVC water tanks exc. 500 litre and n. exc. 1000 litre capacity , setting aside for treating the platform surfaces and hoisting, reconnecting and refixing in position after cleaning the tank complete all as specified & directed. |
| 3 | Taking up or down old un serviceable steel tubing including GI fittings and connections of walls, ceiling, floor etc of 15mm bore complete all as specified & directed. |
| 4 | Ditto as per item No 3 above but 20 mm bore complete all as specified & directed. |
| 5 | Refixing old steel tubing 20mm bore and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified & directed. |
| 6 | Supply & fix 15mm bore, steel water tubing medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing complete all as specified & directed. |
| 7 | All as per serial item No. 06 above, but 20mm bore. |
| 8 | S&F in repair 20 mm dia Gun -metal,globe or gate valves,with iron wheel head ,screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 9 | S&F in repair 15 mm dia Gun -metal,globe or gate valves,with iron wheel head ,screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 10 | Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillers etc complete as specified & directed. |
| 11 | Material & labour brick work in CM 1:6 with old size sub class B, bricks straigh or curved on plain exeeding 6m mean radius complete all as specified & directed. |
| 12 | Taking down cement plaster from wall/ celing and soffits of chajja etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified & directed. |
| 13 | Taking down old un serviceable eaves gutters and rainwater pipes PVC(any size or pattern), including all fittings, heads, shoes, bends, swan-necks, clamps any type etc. measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 14 | S&F 110 mm bore PVC (SWR) Soil waste, rain water pipe and vent pipes single socketed in any length with rubber ring joints fixed to walls, floor etc. as per site requirement making good disturbed portion to match the existing complete all as specified and directed. |
| 15 | Supply and fix PVC bends 110 mm bore, any radius complete all as specified & directed. |
| 16 | Material & labour 15 mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces finished even and smooth (without using extra cement complete all as specified and directed. |
| 17 | Material and Labour preparation of old plastered or unplastered surfaces of wall including cornices, pilaster etc by brooming down or steel wire brushing, scrapping down smoke Soot, moulds, moss and trading oil and greasy spots etc and apply Two coats of cement base paint white or tinted complete as specified and directed. |
| 18 | M&L for two coat of cement based paint over a coat of alkali resistant primer after preperation of new plaster surfaces on surfaces of walls Complete all as specified and directed. |
| 19 | Taking down of old roof treatment of any description including Brick bat coba finishes,benching coping, cement mortor screeds,chinamosic tiles,brick/pcc tiles, ceramic tiles from roof surfaces etc including cleaning ,brushing and watering to joints and grooves and throwing the demolition materials/waste, debris away from the MOD Land, roof of height n.ecx 11 mtr etc complete all as specified and directed. |
| 20 | Material and labour for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in roof , paddings, mud stops slightly chamfered or rounded in edges including required grove cutting complete all as specified and directed. |
| 21 | M&L Cutting out cracks to V-section in existing roof surfaces, chases pinning in making good to facings where required and repair with fiber reinforced mortor equivalent to ( MAPEGROUT T40 ) mixed with SBR in ratio 1:1 for repair of cracks and that filled with sigle component polyurethane sealent eqivalent to (NITOSEAL :PU50) at the roof for the water proofing as per manufacturer instructions complete all as specified and directed. |
| 22 | Material & labour for cleaning the surface of the stone/concrete roof and slab with wire brush/ mechanical grinder and specialized water misting techniques applying water jet using a fine nozzle sprinkling system calibrated to spray a fine mist along the stone/concrete surface and removing complete and applying one coat of sealer @ 0.2 kg/sqm of SBR equivalent to (Dr Fixit 302 Super latix) and cement in ratio of 1:1 having a capacity of filling cracks of less than 3mm and having bonding agent propertycomplete all as specified and directed.Note : 1. This item has to be applied on mother slab before laying any screed bed or PCC as a water proofing process. 2. This item shall be carried by authorised applicator of manufacturer. |
| 23 | M & L applying high performance polyurethene liquid membrane waterproofing coating cold applied in two coats @ 1.5kg/Sqm/2coats spray/brush applied, with an elongation of 300% to 700% and tensile strength of not less than 3N/Sqmm as per ASTM D412 and ASTM C2370, crack bridging ability of 3.5mm as per ASTM C1305, shore a hardness of not less than 60 as per ASTM D2240. The item includes applying epoxy primer @ 0.15Kg/Sqm and a geotextile of 40 GSM to be applied which is the combination of base and hardener water based epoxy system as per manufacturer's instructions complete all as specified and directed. Note:- 1. The contractor shall submit a garantee of 07 year from the date of completion of work for waterproofing treatment alongwith manufactures's garantee. The 5% amount of item No 19 to 23 for waterproofing treatment shall be withheld from contractor's final bill till the expiry of gurantee period. The contractor at his own option may furnish fix deposit receipt pledged in favour of GE(E) Agra against gaurantee money.2. The water proofing work complete against BOQ item No.21 to 23 shall be carried out by authorised applicator of manufacturer. The name of applicator shall be got approved from GE before commencement of work. |
| 24 | M& L for plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in coping, kneelers, apex stone, benching, water trough and the like, including necessary form work (straight or curved) watering, slightly rounded or chamfered angles, throating etc complete all as specified and directed. |
| 25 | Material & labour for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in CM (1:6) surfaces finished even and fair faces complete all as specified and directed. |
| 26 | Material & labour 5mm thick rendering in CM 1:3 concrete surfaces of ceiling etc, finished surfaced even & smooth with out using extra cement complete all as specified & directed. |
| 27 | Material and labour for preparation of newly plastered wall surface and applying two coats oil bound distemper a coat of 3mm thick interior wall care putty and a coat of primer.complete all as specified and directed. |
| 28 | Material & labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash to match the existing as required, complete all as specified & directed. |
| 29 | S&F in repairs Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for pipe upto 110 mm bore complete all as specified and directed . |
| 30 | Supply & fixing rotational moulded polyethylene water storage tanks 500 liters capacity, (cylindrical, vertical in closed top) hoisted and fixed in position with all fittings Including ball valves high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and dismantling existing water tanks complete all as specified & directed. |
| 31 | Supply & fixing rotational moulded polyethylene water storage tanks 1000 liters capacity, (cylindrical, vertical in closed top) hoisted and fixed in position with all fittings Including ball valves high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and dismantling existing water tanks complete all as specified & directed. |
| 32 | Supply and fix 25 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape in any requirement complete to walls and ceilings or laid in floors iincluding all connected brass CPVC fittings and cutting grooves, filled with CM 1:6 complete all as specified Please Enable Macros to View BoQ information |