| 1 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil |
| 2 | Excavating in trenches n exc 1.5m wide and n exc 1.5 mtr depth and average 1.5 mtr in depth and getting out for foundation etc in Hard/dense soil |
| 3 | Returning filling in spreading levelling watering and well ramming in layer n.exc. 25 cm thick. |
| 4 | Removal excavated surplus soil to a distance n.exc. 50 m and depositing at level n.exc. 1.5 m above the starting point all as directed by Engineer-in-Charge |
| 5 | M&L Demolition of Cement Concrete (un rainforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and as directed by Engineer-in-Charge. |
| 6 | Dismatling Stone slabs,paver block and tiles of any description or thickness in floors, aprons etc. |
| 7 | M & L for hardcore of gauge n exc 63 deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface |
| 8 | M&L cement concrete 1;4:8 type D2 (40mm aggregate) 75 mm thick as in sub base |
| 9 | M&L for 50 mm sand cushioning under interlocking in floors including watering and consolidation. |
| 10 | M&L for Machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 60 mm thickness, M-35 with grey cement and pigment grade all as specified and directed by Engineer-in-Charge. |
| 11 | M&L for filleting in any position and to any shape in cement mortar 1:4 including all mitres, stops etc section of fillet exc 25 but n.exc 50 Sqcm |
| 12 | Dismantling floor, hearth or wall tilling including cement mortor bedding (but not backing), removing serviceble tiles to store and rubbish off the premises complte all as specified. |
| 13 | M&L for Coloured Non Skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed in CM 1:6 |
| 14 | M&l for Glazed ceramic tiles of any colour in vertical surfaces 300 x 600x 8mm thick mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat cement plaster in CM 1:4 including refixing electric points and switch boards where as specified and as directed by Engineer-in-Charge |
| 15 | Taking up or down steel tubing and connections, 15mm size of pipe including cleaning for re-fixing or removal to store |
| 16 | Taking up or down steel tubing and connections, 20mm size of pipe including cleaning for re-fixing or removal to store |
| 17 | Supplying and laying of CPVC pipes 20mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling/conceal or laying in floors complete all as specified. |
| 18 | Supplying and laying of CPVC pipes 25mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling/conceal or laying in floors complete all as specified. |
| 19 | S&F in repairs two piece EWC 680x360x765mm snow white, with seat cover and Twin flushing cistern including 32 mm flush pipe complete all as specified and directed by Engineer-in-Charge by Engr-in-Charge as per Jaquar / CERA -CAT No. S1021103 S Trap 230mm, CAT No S1060101 Cistern, CAT No B1510124 seat cover, CAT No B1810101 Twin Flush fittings all as specified |
| 20 | S&F Pillar taps 15 mm dia, cast copper alloy, with capstan heads, fancy type chromium plated ,screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed in repairs complete all as specified. |
| 21 | S&F in Bib taps 15 mm dia, fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed for 15 mm dia pipe fixed in repairs complete all as specified |
| 22 | S&F in rep Stop/angle valves 15 mm dia, fancy type chromium plated, singl /double way screwed down, high pressure, screwed both ends for 15mm dia pipe or for unions fixed in repairs |
| 23 | S&F CP Health faucet of brass body with wall hook and 1 mtr stainless steel braided connection pipe fixed in repair complete all as directed by Engineer-in-Charge Cat No F8030107AB or equivalent in Hindware / Parryware. |
| 24 | S&F Stainless steel soap dish, white of size 160X160X90 mm as approved fixed with brass screws or embedded in wall . Cat No. F5003106 or equivalent in other makes as specified |
| 25 | S&F in rep Tubular Towel rail brass chromium plated 20mm dia fancy type 60cm long including bracket fixed between flanges complete Cat No. F5015104CH or equivalent in Hindware/ Parryware |
| 26 | S & F in repair Wash basins, Vitreous China white (flat back type) size 630x450mm, including brackets complete all as specified |
| 27 | M&L for 32mm size Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed , |
| 28 | S&F in repair 600X450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick commerical plywood with aluminium channel frame alround and 02 No's hanging clips and fixed to wooden plugs with CP brass screws and cup washers complete all as specified and as directed by Engineer-in-Charge. |
| 29 | S&F in repairs Vitreous China urinal, coloured of size 420x395x635mm large flat back with all fittings including spreader, CP connection suitable for 15mm bore stop valve, discharge pipe and taking down the existing one. |
| 30 | Demolition of Brickwork or stone/bou-lder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 31 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. |
| 32 | M & L PCC (1:4:8) type D-2 (Using 40 mm graded stone agg.) as in foundation, filling and mass concrete. |
| 33 | Formwork to sides of concrete foundation, footings, base of columns, raft and raft beams, sides and soffits if any of foundation and plinth beams and similar work, vertical or to better of rough finished surfaces of concrete of flat. |
| 34 | S&F MS TMT bars 10 mm dia & over, cut to length, bent to shape required including cranking and bending and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and as directed by Engineer-in-Charge. |
| 35 | M&L M-15 (Nominal Mix) with 20mm graded agg in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete |
| 36 | M&L for Brickwork with Sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 in narrow widths including Cutting out bricks/stone, forming toothing for, and bonding new into old brickwork /stone masonry |
| 37 | M&L for Rendering 15 mm thick CM 1:6 on fair faces of brick work or concrete surfaces and to be finished even and smooth(without using extra lime or cement) |
| 38 | All as per item no 37 here-in-before but in cm 1:4 on external surfaces . |
| 39 | M&L 5mm thick cement plastering in cement mortar 1:3 on concrete surfaces of ceiling finished even and smooth without using extra cement. complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply only Integral Water Proofing Compound |
| 41 | M&L for Pre-Polished calibrated Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 15 mm thick screed in CM 1:6 including rubbing and polishing complete |
| 42 | M&L for 18 to 20 mm thick Granite (of any type) work in single piece (table rubbed and polished) in steps, floors, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade over and including 20mm thick CM (1:6) bedding layer complete all as specified and as directed by Engineer-in-Charge. |
| 43 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings |
| 44 | M&L Rolled sections as in main and cross beams, hip and jack rafters;pillar post, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates etc confirming to Fe-410W (Gde E-250) quality -A grade complete all as specified and directed by Engineer-in-Charge |
| 45 | M&L for preparation of old/new steel surfaces, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of anti-corrosive epoxy(poly Urethane based) over a coat of epoxy primer of approved make complete all as specified and directed by Engineer-in-Charge. |
| 46 | S&F Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment of FE 410-W (Gde-E-250) quality B |
| 47 | S&F MSA Flat wind ties for roof including securing bolts, posts and struts including all necessary drilling bolt or riveting etc and similar work confirming to FE-290 Gde E-165. |
| 48 | S &F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 49 | S &F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/ roof covering/cladding to wall, fixed with self tapping screws as specified |
| 50 | M&L for filleting section of fillet exc 25 but n.exc 50 sq cm in cement mortar 1;3 in any shape in cement mortar. |
| 51 | M&L for complete removal of old plastered surfaces of walls, ceiling,Pillars, cornices etc by brooming down with steel wire brush, scraping down smoke shoot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying 3 mm thick white cement based wall care putty on plastered surface of internal wall and ceiling smooth finish.etc of approved make & shade on walls and other places complete all as specified and as directed by Engineer-in-Charge.Note-: Rates are inclusive all scafoldings used for up to the height of 4 storeys. |
| 52 | M&L for one coat of acrylic waterbased interior grade primer @ 0.8 ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface for painting of subbsequent coats up to 15M height all as directed by Engineer-in-Charge. |
| 53 | M&L for applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface up to 15M height complete all as specified and directed by Engineer-in-Charge. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. |
| 54 | M&L for complete removal of smoke, shoot,moulds,vegetation, moss and efflorescent salts and trading oil and greasy spots from surface areas using high-pressure water jet spray technology pressure (5000-10000)PSI , as part of surface preparation for repainting. by skilled labour complete all as directed by Engineer-in-Charge.Note-: Rates are inclusive all scafoldings used for up to the height of 4 storeys. |
| 55 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/old surfaces including removal of old paint and preparation of surface all as specified and as directed by Engineer-in-Charge. |
| 56 | Taking down chowkats or frames N.exc 1.5 Sqm with shutter (without taking of shutter from the frame. |
| 57 | Taking down chowkats or frames exc 1.5 and n. exc 4.00Sqm with shutter (without taking of shutter from the frame). |
| 58 | M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately) |
| 59 | M&L for Factory Made 24mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Flush Door Shutter of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cum an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 50 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixing with 3 nos stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company. |
| 60 | S&F Aluminum powder coated partitions, partly panelled & partly glazed with 12 mm thick both side laminated MDF board in bottom panel and 5mm thick tinted glass in top panel fixed with clips,extra aluminium support, aluminium beads, rubber gaskets etc., centre to centre distance of vertical member shall n.exc 1mtr and horizontal members shall n.exc 1.10 mtr using following aluminum powder coated section as mentioned in Jindal Catalogue complete all as specified & as directed by Engineer-in-Charge :- (a) SP – 20048 (b) DP - 20047 (c) Glazing clips - 19352 |
| 61 | S&F powder coated Aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws, 5mm th glass(Plain/frosted) and all necessary arrangements including frame for chowkate etc. complete all as specified |
| 62 | S & F 100 mm size Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, typeB-11 |
| 63 | S&F Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed 150mm long. |
| 64 | S&F 200mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed |
| 65 | S&F 100mm Extruded brass handles, fabricated type polished |
| 66 | Taking down (dismantling)wall and ceiling boards(fibre, pulp, insulation, etc) or insulation boards/slab/blankets, any thickness, including cover fillets complete all as specified and as directed by Engineer-in-Charge. |
| 67 | S&F \\"RAJSHRI\\" BRAND 22mm thick False Ceiling made of PVC insulated panels of size 600mm x 600mm. Wall thickness of panel 1.5mun (±0.1) on both side. On 22mm EPS panel 1.5mm (±0.1) Plain PVC sheet of Density 600 Kg/Cbm manufactured by an ISO-9001-2015 cetified company, is stuck on both side with adhesive The panel is inserted in a frame made of anodised Aluminum \\"T\\" section of size 1\\"x1\\" (25mm x 25mm) in square type grid of size 2' x 2' (600mm x 600mm) The aluminium framework is supported from the ceiling with the help of 'J' hook and G.I. wire/6mm M.S. rods of required sizes to maintain proper level. The aluminium framework is supported on side wall with the help of aluminium \\"L\\" section of size 1\\"x1\\" (25x25mm) angles. Complete as per direction of Engineer-in-charge, manufacturer's specification & drawing, |
| 68 | Taking down steel rolling shutter of any size with all fittings complete |
| 69 | S&F in repairs 1 mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; gear operated type with bevel gear box and crank handle |
| 70 | Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credits and making good distrubed surfaces of walls, floors etc complete all as specified and directed by Engineer-in-Chargeat site. |
| 71 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed by Engineer-in-Charge. |
| 72 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed by Engineer-in-Charge. |
| 73 | Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard complete all as specified and as directed by Engineer-in-Charge. |
| 74 | M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLS multi stranded conductor cable in and including PVC casing caping ISI marked inclusive of tees ,bend ,elbows etc fixd to wall/ceiling upto and including modular box of required module for housing modular switch socket etc with modular cover plate with frame of required module complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLS cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal complete all as specified and directed by Engineer-in-Charge for following :-(a) One light point controlled by one, one way modular switch 6 Amps |
| 75 | All as per item no 74 here-in-before (b) One fan point/ exhaust fan point controlled by one, one way modular switch 6 Amps and regulator |
| 76 | All as per item no 74 here-in-before (c) One 2/3 pin 6 Amps modular switch socket outlet point controlled by one modular switch on the same board. |
| 77 | All as per item no 74 here-in-before (d) One 2/3 pin 6 Amps modular switch socket outlet point controlled by one modular switch on independent board. |
| 78 | All as per item no 74 here-in-before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 79 | S & F for modular switch,1 way 6 amp,1 module 230 Volts complete all as specified and directed by Engineer-in-Charge. |
| 80 | S & F for modular switch,1 way 16 amp,1 module 230 Volts complete all as specified and directed by Engineer-in-Charge. |
| 81 | S & F for modular socket outlet 2/3 pin combined, 6 amp, 2 module 230 Volts complete all as specified and directed by Engineer-in-Charge. |
| 82 | S & F for modular socket outlet 2/3 pin combined, 6A/16A amp, 2 module 230 Volts complete all as specified and directed by Engineer-in-Charge. |
| 83 | S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified |
| 84 | S & F for modular BLDC fan regulator 120W, 2 module complete all as specified and directed by Engineer-in-Charge at site. |
| 85 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC casing caping of white/ ivory colour and its accessaries ISI marked of suitable size fixed to wall/ceiling including one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 4 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 86 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed by Engineer-in-Charge. |
| 87 | S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed by Engineer-in-Charge. |
| 88 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed by Engineer-in-Charge. |
| 89 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with PVC insulated twin twisted copper wire of suitable size complete. |
| 90 | S&F for ceiling fans complete with blades, down rods,electronic and accessories, 230 V, 1200 mm sweep. Min air dilivery 210 CFM with service value 6.00, BEE. Five star rated with brushless direct current motor (BLDC) including connecting up with three core flexible copper conductor cable suitable size from ceiling rose to fan terminal with necessary accessories complete all as specified and directed by Engineer-in-Charge. |
| 91 | Supply and fixing LED Bldg sec light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 92 | M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x6.0 mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0mm dia Protedcted by light GI Pipe 20 mm dia and 15 dia med grade for watering pipe and connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, iron funnel,Iron pit cover and chamber all as shown in electrical plate No. 3 connected to earthing test point including testing on completion complete all as specified and directed by Engineer-in-Charge. |
| 93 | Suppy and fixing PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep all as specified and directed by Engineer-in-Charge. |
| 94 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 1.5 Sq mm nominal area and drawing into existing surface/recessed steel cable tray fixed to wall/ceiling including one run of PVC insulated with 1.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 2.5 sqmm cableand one run of 1 sqmm cable will be measured as one unit |
| 95 | M&L for safe dismentling and removal of 04 LAN server boxes currently mountd on the all ensuring proper disconnecting of all associatedd power data and grounding cabls without cauing any damage to the existing infrastructure and handed over to user at site duly properly cleaned. Care must be taken to preserve the physical conition of the server boxes and the mounting sufaces all as specified and directed by Engineer-in-Charge. |
| 96 | Taking down existing end cables of point wiring for fan and recessed mounting LED luminaire 600 mm x 600 mm carefully and refixing and jointing the same in their oiginal position after complition of false ceiling work all as specified and directed by Engineer-in-Charge. |
| 97 | M&L for careful dismantling and removal of existing casing caping with all enclosed electrical wirring and switch boxes from the floor, ensuring no damage to the building structure or associatedd installations, disconnection of all circuits after proper isolation of supply, labeling and safe removal of wires, unscrewing and detaching the casing caping sections an neatly stacking all removed materials including wires, casing caping channels and accessoris shall be accounted for and formally handed over to the MES representative with proper documentation and ensuring complete site clearance after complition all as specified and directed by Engineer-in-Charge. |
| 98 | M&L for careful dismentling and removal of existing wall mounting surveillance camera along with its all associatedd mounting hardware, brackets and cabling without cauusing damage to the equipments or surrounding structure, disconnection of power and signal cables, proper labeling/tagging of connctions, carefully detachment of the camera and accessories. The dismentled camera shall be handed over in working condition to the ddesignated user/authority alongwith all associated parts, mounting structure and accessoie complete all as specified and directed by Engineer-in-Charge. |
| 99 | M&L for safe dismantling, relocation, reinstallation, and commissioning of the existing LT Panel of capacity 415 volts, 3 phase, 50 Hz, comprising incoming and outgoing feeders, metering, protection devices, and busbar arrangements. The scope covers disconnection of all incoming and outgoing cables with proper marking/tagging, careful shifting of the panel to the new designated location, preparation of the foundation/base frame, re-fixing and alignment of the panel, reconnection of all cables using suitable lugs, glands, and accessories, and provision of adequate earthing as per IS/IEC standards. All work shall be carried out ensuring minimal downtime, with strict adherence to electrical safety procedures, proper insulation resistance testing, functional checks, and final commissioning for reliable and safe operation. The relocation shall be executed by skilled personnel using suitable tools, equipment, and lifting arrangements, maintaining compliance with relevant statutory norms complete all as specified and directed by Engineer-in-Charge Please Enable Macros to View BoQ information |