| Sl. No. | Item Description |
| 1 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m,incl filing of surplus excavated earth as directed by Engineer-incharge. All Kinds of soil |
| 3 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 5 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloumn pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints,surrounding of pipes and conduits etc.complete(plinth area of the building at ground floor only shall be measured as per I.S.6313(Part ll 1981) aldrine emulsifiable concrete or any other approved material such as hepthachlor or chlordance will be used.The rate of application of chemical emulsion shall be as follows:- |
| 6 | Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering-All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). Incl. Water proofing as required as per direction of E/I . |
| 8 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads Including the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 9 | All works above plinth level upto floor V level Same as above item , Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in all labour , material, T&P etc complete in all respect for all floor Lvl. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 11 | Class 150 brick work in 1:4 cement & coarse sand of 1.50 fineness modulus mortar in foundation & plinth including supply of all material labour and tools and plants etc required for proper completion of work. |
| 12 | Class 150 brick work in 1:4 cement & coarse sand of 1.50 fineness modulus mortar in super structure including supply of all material labour and tools and plants etc required for proper completion of work. |
| 13 | Half brick masonry with Class 150 brick work in 1:4 cement & coarse sand of 1.50 fineness modulus mortar in super structure including supply of all material labour and tools and plants etc required for proper completion of work. |
| 14 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 65 x 125 mm |
| 15 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) Same as above item , 35 mm thick |
| 16 | Providing and fixing M.S grills of required pattern in frames of windows etc. with M.S flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. |
| 17 | Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : 125x64x2.5 mm |
| 18 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16mm X 5mm |
| 19 | Providing and fixing bright finished brass door latch with necessary screws etc. complete 250x16mm X 5mm |
| 20 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm |
| 21 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complet150x10mm |
| 22 | Providing and fixing chromium plated brass handles with necessary screws etc. complete: 125mm |
| 23 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 24 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 25 | Providing and fixing factory made uPVC glazed /wire mesh windows/doors comprising of lead free uPVC multi-chambered frame,sash and mullion/coupler (where ever required) extruded profiles having minium wall thickness of 1.70 mm for series R1 and R2 profiles and 2.10 mm for series R3 and R4 profiles confirming to EN : 12608 in any shape, colour and design duly reinforced with galvinised mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads ,interlocks Inline sash adaptor(where ever required) of appropriate dimension,EPDM gasket,hardware,SS 304 grade fastners of minium 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for mixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame,sash and mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners,including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjasent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD Specification and direction of Engineer -in-charge. Section of steel reinforcement and cross section of uPVC profiles to be as per design approved by Engineer -in-charge.Wire mesh/Glazing of plain/toughened/laminated/ double glass unit with/ without high performance coating as per design requirements and conforming to IS : 3548 & IS : 16231 shall be paid separately. Note :- Structural design proof checked from a Government Engineering Institute,to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m /sec as per IS : 875-Part 3 (ii) Sites with structure height more than 20m for all wind speeds Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (40 mm & above) X (40 mm & above) & Sash (25 mm & above) X (50 mm & above) with Zinc alloy (Zamak) power coated handle on every panel along with multi-point locking system (Height up to 1.2 metre) |
| 26 | Same as above item but Using R4 series with frame (64 mm & above) X (45 mm & above) & Sash (44 mm & above) X (55 mm & above) with Zinc alloy (Zamak) power coated handle on every panel along with multi-point locking system (Height above 1.8 metre) |
| 27 | Providing and fixng glazing in aluminium door, window, ventilator shutters and partitions etc. without EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With glass panes of 5 mm thickness(weight not less thar 12.5 kg/sqm) |
| 28 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 29 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 30 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 31 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 32 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab above 0.50 sqm |
| 33 | same as above item but Extra for fixing marble/granite stone over and above coresponding basic ite, in facia and drops of width upto 150 mm with expoxy resin based (Araldite or equivalent) adhesive including cleaning etc. complete. |
| 34 | same as above item but Extra for providing opening of required size & shape for wash basins/kitchen sink in kitchen platform. Vanity counters and similar location in marble/granite/stone work including necessary holes for pillar taps etc. including rubbing,moulding and polishing of cut edges etc. complete. |
| 35 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20mm(avearage) thick base of cement mortar 1:4(1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 36 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 37 | Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete.(Unpolished) Size of Tile 60x60 cm |
| 38 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm |
| 39 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 60x60 cm |
| 40 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 41 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4( 1 cement: 2 coarse sand: 4 graded stone aggregate of 20mm nominal size) over P.V.C sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3(1 cement: 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete. |
| 42 | 12mm cement plaster of mix: 1:6(1 cement: 6 coarse sand) including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 43 | 15mm cement plaster on the rough side of single or half brick wall of mix: 1:6(1 cement: 6 course sand) including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 44 | 20mm cement plaster of mix:1:4(1 cement: 4 course sand) including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 45 | Applying primer coats with primer of approved brand and manufacture , having low VOC (Volatile Orginic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50grams/litre |
| 46 | Wall painting with premium acrylic emulsion paint of interior grade,having VOC (Volatile Orginic Compound) content less than 50grams/litre of approved brand and manufacture,including applying additional coats wherever required to achieve an even shade and colour. Two coats |
| 47 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 48 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 49 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 50 | Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections. |
| 51 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 52 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 53 | 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. White sand stone |
| 54 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board |
| 55 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles |
| 56 | Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross \\"T\\" of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main \\"T\\" at 600mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. |
| 57 | Design and execution of stone jali work using CNC machines on 50 thick red stone as per approvalwith dry cladding with SS Cramp on SS Framework of 304 grade anchored to existing surface with baseplate and anchor fasteners As per requirement in profile with Stone balustrade for support approval of the Architect/Engineer-in-charge. (Total Height- 1m from finished floor lvl) P&F Cubicals of toilet |
| 58 | Providing and filling of Cinder/Khangar in sunken slab areas including loading, transportation, unloading, spreading,watering and compaction complete as directed at site. |
| 59 | Supply and fixing of 6mm clear toughened + 1.52mm PVB layer + 6mm toughened clear ST-167 laminated glass with MS structural supply fabrication erection with chemical bolt, plate, structural calculation live load, dead load, wind pressure with 1 coats of anti-corrosive zynchromite yellow /red surface primer and 2 coats of approved DUCO paints as per structural design handling lifting, loading unloading from all respect for skylight. |
| 60 | Providing and fixing Glassfiber Reinforced Concrete (GFRC) Ornamental elements Casted with GRC Concrete Mix Design in approved size, Pattern, thickness of Internal Merber25-30mm thick) and size. The element should be made from '53 grade' White Portland Cement manufactured by 'JK Cement' or equivalent Quartz fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘NEG Japan’ or equivalent, Super Plasticizers manufactured by 'BASF' or equivalent, Polymers manufactured by 'BASF' or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by 'BAYFERROX (Germany)’ or 'Phenocheme Industries or equivelent. The material casting should take place in Synthetic Rubber / FRP mould manufactured by 'Reckli'. The GRC Material flextural strength average L.O.P should be above or equivalent to 12N/MM2 for test done on 28days cured samples which thickness should be 50-60mm. The vendor shall submit shop drawings of the same and drawings to be duly approved from Architect/Engineer-in -charge at site. Providing & fixing of GRC maierial/ items should be done using \\"Dry fixing\\" method onto structural support members i.e RCC, Brick work, Mild streel using red oxide & paint. Fixing of GRC material to be done with fixture, GI Fasteners, self tapping screws with all necessary Clits/Clamps, Dash Pins and Fasteners. The vendor shall submit shop drawings of the same and drawings to be duly approved from Architect/Engineer-in -charge at site. (Mentioned items rates is only for GRC Materials.) GRC Decorative Front Elevation Wall Cladding Panel, Size:- 2524mmx900mm |
| 61 | Same as above but GRC Decorative Front Elevation Wall Cladding Panel, Size:- 3522mmx900mm |
| 62 | Same as above but GRC Decorative Columan, Size:- 3450mmx 766mm |
| 63 | Same as above but GRC Decorative Columan, Size:- 3450mmx 618mm |
| 64 | Same as above but GRC Decorative Columan, Size:- 3450mmx 383mm |
| 65 | Same as above but GRC Decorative Columan, Size:- 4200mmx 900mm |
| 66 | Same as above but GRC Decorative Columan, Size:- 4200mmx 750mm |
| 67 | Same as above but GRC Decorative Columan, Size:- 4200mmx 495mm |
| 68 | Same as above but GRC Decorative Window Jaali, Size:- 1537mmx 600mm |
| 69 | Same as above but GRC Decorative Window Jaali, Size:- 2396mmx 600mm |
| 70 | Same as above but GRC Decorative Window Jaali, Size:- 3400mmx 600mm |
| 71 | Same as above but GRC Decorative Edicule, Size:- 2164mmx 1327mm |
| 72 | Same as above but GRC Decorative small Dome with Arch on terrace floor, Arch Size:- 920mm x 900mm, Dome Size:- 450mm X 459 |
| 73 | Same as above but GRC Decorative small Dome only at Mumty Floor, Dome Size:- 450mm X 459 |
| 74 | Same as above but GRC Decorative Boundry wall panel at terrace floor, Height-750mm |
| 75 | Same as above but GRC Decorative Cornice at terrace floor, Size:-450mm X 100mm |
| 76 | Same as above but GRC Decorative Cornice at First floor(side entrance & Porch Cornice), Size:-450mm X 265mm |
| 77 | Same as above but GRC Decorative Cornice at Mumty floor, Size:-450mm X 100mm |
| 78 | Providing and fixing Glassfiber Reinforced Concrete (GFRC) Ornamental elements Casted with GRC Concrete Mix Design in approved size, Pattern, thickness of Internal Merber25-30mm thick) and size. The element should be made from '53 grade' White Portland Cement manufactured by 'JK Cement' or equivalent Quartz fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘NEG Japan’ or equivalent, Super Plasticizers manufactured by 'BASF' or equivalent, Polymers manufactured by 'BASF' or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by 'BAYFERROX (Germany)’ or 'Phenocheme Industries or equivelent. The material casting should take place in Synthetic Rubber / FRP mould manufactured by 'Reckli'. The GRC Material flextural strength average L.O.P should be above or equivalent to 12N/MM2 for test done on 28days cured samples which thickness should be 50-60mm. The vendor shall submit shop drawings of the same and drawings to be duly approved from Architect/Engineer-in -charge at site. Providing & fixing of GRC maierial/ items should be done using \\"Dry fixing\\" method onto structural support members i.e RCC, Brick work, Mild streel using red oxide & paint. Fixing of GRC material to be done with fixture, GI Fasteners, self tapping screws with all necessary Clits/Clamps, Dash Pins and Fasteners. The vendor shall submit shop drawings of the same and drawings to be duly approved from Architect/Engineer-in -charge at site. (Mentioned items rates is only for GRC Materials.) GRC Decorative Columan in Porch area , Size:- 3600mm x 490mm |
| 79 | Same as abobe but GRC Decorative Box paneling on porch roof, Size:- 1070mm x 450mm |
| 80 | Same as abobe but GRC Decorative Box paneling on porch roof, Size:- 1070mm x 650mm |
| 81 | Same as abobe but GRC Decorative Arch in front of Porch between column, Size:- 4200mm x 900mm |
| 82 | Same as abobe but GRC Jaali Border thickness 50mm and pattern thickness will be 25-35mm, Size:- 2715mm x 1050mm, Size:- 1539mm x 1030mm, Size:- 1336mm x 1030mm |
| 83 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 84 | Providing and fixing factory made uPVC glazed /wire mesh windows/doors comprising of lead free uPVC multi-chambered frame,sash and mullion/coupler (where ever required) extruded profiles having minium wall thickness of 1.70 mm for series R1 and R2 profiles and 2.10 mm for series R3 and R4 profiles confirming to EN : 12608 in any shape, colour and design duly reinforced with galvinised mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads ,interlocks Inline sash adaptor(where ever required) of appropriate dimension,EPDM gasket,hardware,SS 304 grade fastners of minium 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for mixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame,sash and mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners,including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjasent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD Specification and direction of Engineer -in-charge. Section of steel reinforcement and cross section of uPVC profiles to be as per design approved by Engineer -in-charge.Wire mesh/Glazing of plain/toughened/laminated/ double glass unit with/ without high performance coating as per design requirements and conforming to IS : 3548 & IS : 16231 shall be paid separately. Note :- Structural design proof checked from a Government Engineering Institute,to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m /sec as per IS : 875-Part 3 (ii) Sites with structure height more than 20m for all wind speeds Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R3 series with frame (55 mm & above) X (40 mm & above) & Sash (30 mm & above) X (55 mm & above) with Zinc alloy (Zamak) power coated handle on every panel along with multi-point locking system (Height up to 1.8 metre) |
| 85 | LANDSCAPPING Trenching in ordinary soil up to a depth of 60cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). |
| 86 | Supplying and stacking of good earth at site including royalty but excluding carriage (earth measured in stacks will be reduced by 20% for payment). |
| 87 | Supplying and stacking at site dump manure from approved source, excluding carriage (manure measured in stacks will be reduced by 8% for payment): Screened through sieve of I.S designation 16mm |
| 88 | Fine dressing the ground complete with All Recpect as per direction of E/I |
| 89 | Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/and good earth to be paid separately). |
| 90 | Mixing earth and sludge or manure in proportion specified or directed. |
| 91 | Providing and laying Neelgiri/Korean grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light watering with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. |
| 92 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20%:1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately): Holes 60cm dia, and 60cm deep |
| 93 | Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 94 | Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 95 | Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge. |
| 96 | Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge. |
| 97 | Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 98 | Providing and stacking of Saraca indica (Sita Ashok) of height 105-120cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 99 | Providing and stacking of Tradescantia, full of leaves in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge. |
| 100 | Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. |
| 101 | Providing and stacking of Syngonium golden of height 30-45 cm. with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. |
| 102 | Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 103 | Providing and stacking of Cassia biflora of height 90-105 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. |
| 104 | Providing and stacking of Ficus panda of height 60-75 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the officer-in-charge. |
| 105 | Providing and stacking of Quisqualis indicia of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. |
| 106 | Providing and stacking of Clerodendrum splendens of height 30 cm to 45cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. |
| 107 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C |
| 108 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C |
| 109 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C |
| 110 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C |
| 111 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 112 | same as above but 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 113 | same as above but 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 114 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 115 | same as above but 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 116 | same as above but 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 117 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 118 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 119 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 120 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 121 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 122 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 123 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 124 | Same as above but 3 pin 5/6 A socket outlet |
| 125 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm) |
| 126 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door |
| 127 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door |
| 128 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 129 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 130 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A |
| 131 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A |
| 132 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 A |
| 133 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A |
| 134 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 135 | Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc 10KVA |
| 136 | Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. |
| 137 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet |
| 138 | Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm) |
| 139 | Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 140 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. 1 run of cable |
| 141 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 142 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25 mm |
| 143 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 32 mm |
| 144 | Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
| 145 | same as above but 150 mm width X 50 mm depth X 1.6 mm thickness |
| 146 | same as above but 600 mm width X 62.5 mm depth X 2 mm thickness |
| 147 | Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP4 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
| 148 | Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. |
| 149 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box wall speakers complete as required |
| 150 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speaker cable Single pair, 2-core, 1.5 sqmm |
| 151 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 152 | Supplying and Fixing 25mm dia Flexible Steel Conduit Pipe along with all ancillaries and accessories like coupler etc. as Required. |
| 153 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 154 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 155 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 156 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 157 | Design, manufacture, supply at site and coordination with contractor for installation, Testing & Commissioning of the following front operated front access 2mm thick steel enclosure free standing/ISMC 75 mm base Channel, indoor type, dust and vermin proof, Main LT Panel with hinged and lockable doors complete with interconnections, electrolytic aluminium crimping lugs, brass glands, bonding to earth and painting,, suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system. The size of cable alley shall be sufficient enough to accommodate the number of run of cable sizes as mentioned in the SLD / Specifications / drawing etc. The said panel shall be also constructed in according with all the statutory authorities / local electricity department / agency (DHVBNL)norms. MAIN LT PANEL (indoor Type) INCOMER 1 no. 400 amps 16 kA 690 Volt (Insulation Voltage) TPN MCCB with Microprocessor based release with protection functions-overcurrent 40%-100% with time setting,selective short circuit 60%-1000% with time setting ,instantaneous short circuit 150%-1200% complete with: 400/5 ratio Class 1.0 for metering 1 - Digital Ammeter scaled 0-400 amps with 3 way and OFF selector switch 1 - Voltmeter scaled 0-500 volts with 3 way and Off selector switch 1 - Multi function Meter (MFM) with RS 485 of 0.5 accuracy to measure voltage, current, power factor, frequency, KW , KVA, KWH, KVAh. Red/Green ON/OFF indicating lamps 1 set of three RYB phase indicating lamps 1- Amber indicating lamp for auto trip 1- Blue indicating lamp for spring charged 1- Surge Protection Device BUSBAR SECTION Electrolytic high conductivity aluminium three phase and neutral busbars. The busbar rating shall be atleast 1 amp per 1mm square, 500 amps suitable to withstand symmetrical fault level of 25 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOING SECTION 1 nos. 250 amps 32 kA 690 volt TPN MCCB with thermal over load and magnetic short circuit release 3 nos - Cast resin current transformers of 250/5 ratio Class 0.5 for metering 1 - Digital Ammeter scaled 0-250 amps with 3 way and OFF selector switch Red/Green ON/OFF indicating lamps 1 nos. 200 amps 25 kA 690 volt TPN MCCB with thermal over load and magnetic short circuit release 3 nos - Cast resin current transformers of 200/5 ratio Class 0.5 for metering 1 - Digital Ammeter scaled 0-200 amps with 3 way and OFF selector switch The Main LT Panel shall be complete with all interconnections, labels wiring, etc as required |
| 158 | Design, manufacture, supplying of the following front operated front access 2mm thick steel enclosure free standing, outdoor type, dust and vermin proof, Feeder Pillars/Panel with IP54 whether proof protection with hinged and lockable Double doors complete with interconnections, electrolytic aluminium crimping lugs, brass glands, bonding to earth and painting,, suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system. Feeder pillar shall be provided with rain canopy. (meter chambers of size 400mm x 400mm each having 6 mm thick bakelite sheet and sealing & locking arrangement with the Space provision for direct type three phase KWH meter and window for meter reading. complete wiring upto KWH meter & meter to MCB shall be done by using adequately rated flexible single core copper wires.) (Supply, sealing & fixing of KWH meter shall be done by authority) Feeder pillar (IP54) suitable for outdoor application having cable entry from bottom only complete with following: INCOMING 1 no. 100 Amps TPN MCCB 16 kA with thermal over load and magnetic short circuit release compete as required. BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 125 amps having interleaving design throughout having a maximum current density as per IEC 60439 suitable to with stand symmetrical fault level of 16 kA at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 4 nos. 63 Amps 690 volt 10 kA FP MCB with fixed neutral with thermal magnetic protective releases. 3 nos. 40 Amps 690 volt 10 kA FP MCB with fixed neutral with thermal magnetic protective releases. 2 nos. 63 Amps 690 volt 10 kA DP MCB with fixed neutral with thermal magnetic protective releases. 1 no. 40 Amps 690 volt 10 kA DP MCB with fixed neutral with thermal magnetic protective releases. 3 no 63 amp 10 kA DP MCB with thermal magnetic protective releases outgoing complete each with Dual setting 24 hour calibrated time switch for automatic operation of the supply, 63 amp Contactor for operation of the outgoing supply through the Time Switch and with 4 nos 10-25 amp SPN 10 kA MCB's in each phase as outgoing. The Feeder Pillar shall be complete with all interconnections, labels wiring, etc as required |
| 159 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm |
| 160 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Above 35 sq. mm and upto 95 sq. mm |
| 161 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Above 95 sq. mm and upto 185 sq. mm |
| 162 | Supply & making cable end termination XLPE insulated 1100 Volt grade cables including the cost of crimping aluminium heavy duty lugs, brass double compression glands, insulation tape etc. complete as required and as below. 3.5 core 150 Sq mm Al XLPE Cable |
| 163 | Supply & making cable end termination XLPE insulated 1100 Volt grade cables including the cost of crimping aluminium heavy duty lugs, brass double compression glands, insulation tape etc. complete as required and as below 3.5 core 120 sq. mm AL. Cable |
| 164 | Supply & making cable end termination XLPE insulated 1100 Volt grade cables including the cost of crimping aluminium heavy duty lugs, brass double compression glands, insulation tape etc. complete as required and as below 3.5 core 95 sq. mm AL. Cable |
| 165 | Supply & making cable end termination XLPE insulated 1100 Volt grade cables including the cost of crimping aluminium heavy duty lugs, brass double compression glands, insulation tape etc. complete as required and as below 3.5 core 70 sq. mm AL. Cable |
| 166 | Supply & making cable end termination XLPE insulated 1100 Volt grade cables including the cost of crimping aluminium heavy duty lugs, brass double compression glands, insulation tape etc. complete as required and as below 3.5 core 50 Sq mm Al XLPE Cable |
| 167 | Supply & making cable end termination XLPE insulated 1100 Volt grade cables including the cost of crimping aluminium heavy duty lugs, brass double compression glands, insulation tape etc. complete as required and as below 4 core 35 sq. mm AL. Cable |
| 168 | Supply & making cable end termination XLPE insulated 1100 Volt grade cables including the cost of crimping aluminium heavy duty lugs, brass double compression glands, insulation tape etc. complete as required and as below 4 core 25 sq. mm AL. Cable |
| 169 | Supply & making cable end termination XLPE insulated 1100 Volt grade cables including the cost of crimping aluminium heavy duty lugs, brass double compression glands, insulation tape etc. complete as required and as below 4 core 16 sq. mm AL. Cable |
| 170 | Supply & making cable end termination XLPE insulated 1100 Volt grade cables including the cost of crimping aluminium heavy duty lugs, brass double compression glands, insulation tape etc. complete as required and as below4 core 10 sq. mm AL. Cable |
| 171 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 172 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 173 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 174 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required 160 mm dia (OD-160 mm & ID-135 mm nominal) |
| 175 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required 200 mm dia (OD-200 mm & ID-175 mm nominal) |
| 176 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100 mm dia |
| 177 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required 150 mm dia |
| 178 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required 250 mm dia |
| 179 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required 300 mm dia |
| 180 | Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 15 |
| 181 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 15 |
| 182 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 15 |
| 183 | Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 15 |
| 184 | Supply laying and termination control cabling with copper conductor PVC insulated and PVC sheathed armoured cables on existing tray including the cost of making connections, glands, copper lugs, ferrules/ cable tags complete as required as below: 2 core 2.5 sqmm |
| 185 | Supply laying and termination control cabling with copper conductor PVC insulated and PVC sheathed armoured cables on existing tray including the cost of making connections, glands, copper lugs, ferrules/ cable tags complete as required as below 4 core 2.5 sqmm |
| 186 | Supply laying and termination control cabling with copper conductor PVC insulated and PVC sheathed armoured cables on existing tray including the cost of making connections, glands, copper lugs, ferrules/ cable tags complete as required as below 6 core 2.5 sqmm |
| 187 | Supply laying and termination control cabling with copper conductor PVC insulated and PVC sheathed armoured cables on existing tray including the cost of making connections, glands, copper lugs, ferrules/ cable tags complete as required as below2 core 4.0 sqmm |
| 188 | Supply and fixing of ABC type fire extinguisher 5 kg as per IS 2171 : 1976 mounted on wall hook |
| 189 | Supplying and fixing 1000 mm wide rubber matting (complying with IS 15652-2006) and suitable to withstand following and as approved by local electricity supply agency. 11 kV Rubber mat |
| 190 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. |
| 191 | Providing first aid box complete as per Indian Red cross society/ St. John Ambulance Brigade and conforming to IS 2217-1963. |
| 192 | M.S. buckets 5 Nos. of 10 litres capacity painted with red oxide paint & lettered as ‘Fire’ with White, complete with mounting free stand including filling with dry sand. |
| 193 | Supply of Rubber hand gloves 11KV grade, as per IS 4770-1968. |
| 194 | Supply, Unloading, receiving, storing,handling, testing and commissioning of 1.1 KV grade cross linked polyethylene (XLPE) armoured aluminum conductor cables. 3 core 10 sq mm |
| 195 | Supply, Unloading, receiving, storing,handling, testing and commissioning of 1.1 KV grade cross linked polyethylene (XLPE) armoured aluminum conductor cables3 core 6 sq mm |
| 196 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm |
| 197 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (19mm) |
| 198 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3 X 6 sq. mm (19mm) |
| 199 | SSupplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (for light fixture) 3 x 1.5 sq. mm |
| 200 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 201 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 202 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 8.0 metre and upto 10.0 metre |
| 203 | Supply, Receiving, storing, handling, shifting at desired location, assembling of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs,Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket for fixing DP MCB & Power terminal for LILO of LT cabling with all accessories as supplied by the manufacture , 9 mtr. Long pole with top dia 70 mm and bottom dia 155 mm with base plate of size 260 x 260 x 16 mm as required. |
| 204 | Supply, fabrication and erection of Single arm bracket 1500mm overhanged made of 48.3 OD dia G.I. pipe (3.25mm thick) as per IS:1161 welded to canopy 400mmm long with angle of inclusion of 105 Degree to the vertical. The canopy should be suitable for 100/70mm top dia pole. The bracket should be hot dip galvanised along with 3 number 10 mm dia ss bolts. |
| 205 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 206 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 207 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 208 | Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim 12 -15 watt |
| 209 | Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 36 watt |
| 210 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18- 22 Watt |
| 211 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 90 watt |
| 212 | Supply, installation, testing & commissioning of 10W LED 2ft batten luminaires with housing made of Aluminum Extrusion for thermal management with an anodized finish. Luminaire should be suitable for Wall/Ceiling mounting with SS clamps. Luminaire shall deliver excellent illumination & visual comfort with CRI of >80, High transmittance Opal Polycarbonate diffuser for glare-free symmetric light distribution. Luminaires should be with 100 lm/W System Efficacy and designed for Avg. LED Life (L70 B50) 50,000 Burning Hours & with high efficient Photobiologically safe LEDs. Luminaire should be Powered by an integral electronic constant current Potted driver offering THDi<15% , compliance, Output Short-circuit protection, Surge Voltage protection, and other reliability tests as per IS:15885 Part 2/Sec 13. Luminaires should be provided with 4kV surge protection. . Luminaire Should conform to IP20 Classification Luminaires manufacturer to have an in-house NABL-accredited Laboratory for testing Photometric parameters. |
| 213 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum) |
| 214 | Supply of exhaust fan with gravity louvers and bird guards etc. complete as required for 250 mm dia. |
| 215 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 216 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 217 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 218 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 219 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink of approved make as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board 510x1040 mm bowl depth 250 mm |
| 220 | Providing and fixing approved make hand shower (Health faucet) of 1.2mtr long with 8mm dia Easy Flex Tube with wall hook and flow restrictor with flow rate 6 litre per minute at 3 bar in chrome finish and wall hook. |
| 221 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 222 | Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge.For physically handicap person consisting of; Wall Hung WC with PP soft close seat cover, HingesWall with built in Jet Concealed Cistern Cistern-01 no. Flush Plate -01 no Wall hung Wash Basin -01 no Spatula Single lever Wall mounted Grab bar 600 mm long - 2 nos Wall mounted Hinged hand rail 750 x 100-01 no Bottle Trap Waste Coupling Stainless soap dish Tissue paper holder |
| 223 | Providing & fixing heavy quality PVC waste pipe for sink including PVC waste fitting Complete Flexible Pipe 40mm Dia |
| 224 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 225 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 226 | Providing & fixing toilet paper holder C.P. brass as per direction of E/I |
| 227 | Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipes for soil, waste SWR Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors), reducers, couplers, cowels, clamps, hangers, rubber rings, clean outs, provision for C P Grating fixing for any waste connection from washing machine etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc. inside duct / suspended from floor under false ceiling for proper completion of the work. The rubber ring shall confirm to IS:5382. ( (SOIL, WASTE, RAIN WATER & VENT) 75 mm diameter pipe |
| 228 | Same as above item but 110 mm diameter pipe |
| 229 | Same as above itembut 160 mm diameter pipe |
| 230 | Providing and fixing in position Upvc full bore P / S trap with 50 mm water seal (IS : 14735) of the following sizes . Making proper connection with solvent cement. |
| 231 | Providing, fixing & testing uPVC pipes, conforming to IS 4985 class 3 (6 kg/cm2) including injection moulded fittings, jointing with solvent cement, cutting and making good the floors and walls and jointing to trap/waste pipe, complete of outer dia. (Indirect waste) 40 mm diameter pipe |
| 232 | Providing, fixing & testing uPVC pipes, conforming to IS 4985 class 3 (6 kg/cm2) including injection moulded fittings, jointing with solvent cement, cutting and making good the floors and walls and jointing to trap/waste pipe, complete of outer dia. (Indirect waste) 50 mm diameter pipe |
| 233 | Providing, fixing & testing uPVC pipes, conforming to IS 4985 class 3 (6 kg/cm2) including injection moulded fittings, jointing with solvent cement, cutting and making good the floors and walls and jointing to trap/waste pipe, complete of outer dia. (Indirect waste) 63 mm diameter pipe |
| 234 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 235 | Providing and fixing PTMT towel rail complete with brackets fixed towooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour |
| 236 | Providing & fixing soap dish holder of approved design. |
| 237 | Providing and fixing CP brass single lever low flow wall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete with flow rate 2.5 litre per minute at 3 bar including cutting and making good the walls where required. |
| 238 | Providing,Fixing wall mounted of approved make Double Coat hook on door complete. |
| 239 | Providing and fixing CP brass 2 Way Bib cock with wall flange with flow restrictor with flow rate 2.5 litre per minute at 3 bar. |
| 240 | Providing, fixing, testing & commissioning of Floor drain made of uPVC reducing elbow (110x63 mm) with horizontal drain outlet of 63 mm OD, round top of 110 mm OD. (Floor Drain) |
| 241 | Providing & fixing uPVC clean out plug with suitable opening with threaded uPVC socket fixed to uPVC pipe joints as required complete in all respects. 110 mm dia |
| 242 | Providing, fixing and testing of uPVC SWR inlet fittings with two or three saddle inlets of 40, 50 or 63 mm size, fabricated from 110 mm outer dia uPVC pipes and fixed to uPVC traps with solvent cement joint complete in all respect. |
| 243 | Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge. Circular Type 125 mm nominal dia with 25 mm waste hole |
| 244 | Providing, Installing & fixing storage type water heater of approved make (vertical/horizontal type ) with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. Capacity 25 litres |
| 245 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes |
| 246 | Same as above but 20 mm nominal outer dia Pipes |
| 247 | Same as above but 25 mm nominal outer dia Pipes |
| 248 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer dia Pipes |
| 249 | same as above but 25 mm nominal outer dia Pipes |
| 250 | same as above but 32 mm nominal outer dia Pipes |
| 251 | same as above but 40 mm nominal outer dia Pipes |
| 252 | same as above but 50 mm nominal outer dia Pipes |
| 253 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work 50 mm nominal outer dia Pipes |
| 254 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20mm nominal bore |
| 255 | same as above but 25mm nominal bore |
| 256 | same as above but 40mm nominal bore |
| 257 | same as above but 50mm nominal bore |
| 258 | same as above but 65mm nominal bore |
| 259 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore |
| 260 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 15 |
| 261 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 15 |
| 262 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 15 |
| 263 | Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 50 mm diameter pipe |
| 264 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 265 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15mm nominal bore |
| 266 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore |
| 267 | Providing and fixing C.P. brass angle valve for basin mixture and geyser points of approved quality confirming to IS: 8931. |
| 268 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 50 mm dia |
| 269 | Providing, fixing, testing & commissioning of level operated water type butterfly valve conforming to IS : 13095/BS 5155 having CI iron body , SS 316 grade dick, EPDM / nitride complete with 2 Nos. matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes with locking arrangement. Pressure Rating PN 25 : 80 mm dia. Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 25 rating as specified. |
| 270 | same as above but 65mm dia. |
| 271 | Providing & fixing CI `Y' Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. 80mm nominal bore |
| 272 | Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: Underground / Overhead Tanks.) 25mm dia pipe, 600mm long with size of 250x250x6 mm MS plate |
| 273 | same as above but 32mm dia pipe, 600mm long with size of 250x250x6 mm MS plate |
| 274 | same as above but 40mm dia pipe, 600mm long with size of 300x300x6 mm MS plate |
| 275 | same as above but50mm dia pipe, 600mm long with size of 350x350x6 mm MS plate |
| 276 | Supplying and fixing in position of approved quality Solenoid Valve with by-pass arrangement, isolation cock etc. complete with all required accessories such as level sensor, level indicator, level controller and required cabling for the same. 50 mm dia |
| 277 | Providing, Installing and Giving satisfactory field testing of Static (Ultrasonic) Domestic Battery operated, MID (Measuring Instrument Directives) approved Static AMR Water Meters diameters having no moving/fixed part in contact with water, with fully body made up of composite material, confirming to ISO 4064 along with manufacturing test certificate and Guarantee certificate with Meter & Battery Guaranteed up-to 10 years with RF Technology for communication. Memory of the device should be directly accessible through an optical scanner. 50 mm dia |
| 278 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 150 mm diameter HDPE pipe/ RCC pipe / S. W. pipe |
| 279 | same as above but 250 mm diameter HDPE pipe/ RCC pipe / S. W. pipe |
| 280 | same as above but 300 mm diameter HDPE pipe/ RCC pipe / S. W. pipe |
| 281 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180 x 150mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation15 |
| 282 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150mm dia RCC pipe |
| 283 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 250mm dia RCC pipe |
| 284 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 300mm dia RCC pipe |
| 285 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designatio 15 With common burnt clay F.P.S. (non modular) bricks of class designation 15 |
| 286 | same as above item but Extra for depth for manholes: Size 90 x 80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 15 |
| 287 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 288 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality HD - 20 Circular shape 560 mm internal diameter |
| 289 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter |
| 290 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete For pipes 350 to 450 mm diameter |
| 291 | Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 15 |
| 292 | Excavating trenches by mechanical / manual means of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,for all depth including getting out the excavated soil,& then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposing of surplus excavated soil as directed, within lead of 50m. All kinds of soil Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia |
| 293 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: Ordinary rock Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 294 | Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. Ordinary Rock |
| 295 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12mm dia steel bar conforming to IS :1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and heaving manufactures permanent identification mark to be visible even after fixing \\" including fixing in manholes with 30x20x15 cm cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size )complete as per design. |
| 296 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. HD-20 circular shape 560 mm internal diameter. |
| 297 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil 100 mm dia. |
| 298 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 200 mm nominal size dia. |
| 299 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia. |
| 300 | Supplying, filling, spreading & levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 301 | Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 302 | Supplying, filling, spreading & levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer –in-charge. |
| 303 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 304 | Providing and fixing suitable size threaded mild steel cap/shoe or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia |
| 305 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. |
| 306 | Supply, installing, testing and commissioning of factory assembled clear water packaged hydro-pneumatic pumping system ( with variable frequency drive for NOS pump) as per following details: The packaged unit shall be complete with required delivery and suction header along with all necessory valve and other accessories: : ( to be place on terrace for Domestic water supply) a) Pumps: Vertical monoblock booster pumpset with mechanical seal and VFD-2 nos. (1 working) Material of Construction (M.O.C): Corrosion Resistant in genera Casing — Stainless Steel -AISI 304b) Pressure Tank: FRP vessel with replacable polyetheruethane (PEU) bladder certified for drinking water. Minimum 8 Bar pressure rating — 1No. 150 Lts. Capacity. c) Interconnecting Pipe work, Valves and Vibration Eliminators : Common suction & delivery headers in hot dipped galvanised iron pipe, Isolating valves, non return valves, Y-strainer and vibration eliminators on suction & delivery side of pumps.including making connection with the exiisting suction header d) Common fabricated base frame, duly painted. e) Power and control cabling between panel and pumps. f) Accessories like presure guages, pressure switches etc. g) Electric control panel mounted on the skid for automatic operation of pumps comprising incoming switch fuse unit/MCBB, digital voltmeter & ammeter with selector switches, over load and under voltage protection devices, single phase preventors, MCB and DOL starter for NOS pump, indicating lights etc. all complete. Programmable Control System shall be PLC based, duly authentiated by the Pump Manufacturer. Notes: 1) Switchgear and starter ratings are indicative. The Tenderer shall quote for the actual rating required as per the pump model proposed by him. etc complete as per direction of E/I |
| 307 | Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free batteries -1 set. |
| 308 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 309 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 310 | Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 311 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 312 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 313 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 314 | g) Electric control panel, cubical type, made out of 14 guage MS sheet stove enamelled, for automatic/manual/remote operation of the fire pump above. Control panel (to be installed at terrace near the pump) with incoming 63A TPN switch disconnector, DOL automatic pressure switch operated starters with push buttons for manual over ride, control wiring, ammeter, voltmeter, phase indicators, Remote Panel with push buttons for manual operation(the remote panel shall be located at ground level) all complete (The Contractor must submit the Single Line Diagram and Fabrication drawing for Consultant's approval before supplying the panel).Note: h) Shade: The entire package including pump, skid, interconnecting piping shal be finished in Fire Red Colour. |
| 315 | Supplying,Installation,testing & commissioning of dust & vermin proof double door with canopy type taperd roof wall / floor mounted compartmentlised feeder piller type cubical control Panel for fire fighting terrace pump of front area not less than 1.0 Sqmtr. and depth not less than 300 mm, made out of 2mm thick CRCA sheet with 100 Amp. 4 strip aluminium bus bars with front openable door & locking arrangement, interconnection, control wiring, intrigation with pressure switch i/c suppying & fixing following switchgears & control gears/starters etc. as required. Incomming 63 Amps. TP & N SFC with HRC fuses Voltmeter (0-500 Volt) with selector switch. Ammeter (0-60 Amps.) with selector switch & CTs. Set of 3 phase indication lamp Suitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation. Selector switch for local/remote, auto/manual/off operation ON/OFF indication etc. |
| 316 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge. 3 X 10 sq. mm (22mm) |
| 317 | Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/ masonary Open Duct/ cable tray/ open in air etc. as requred. 3 core, 10 sq.mm. Aluminium Armoured |
| 318 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. ( For Underground ) 100 mm. Dia |
| 319 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Plant Room piping/Vertical Riser/Downcomer/Floor) 25 mm dia |
| 320 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Plant Room piping/Vertical Riser/Downcomer/Floor) 80 mm dia |
| 321 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Plant Room piping/Vertical Riser/Downcomer/Floor) 100 mm dia |
| 322 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal |
| 323 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal |
| 324 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia |
| 325 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 150 mm dia |
| 326 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia |
| 327 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 mm dia |
| 328 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal |
| 329 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 36 m |
| 330 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal |
| 331 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe. |
| 332 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 333 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 334 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required |
| 335 | Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete. |
| 336 | Providing & Fixing of MS door made up of 16 gauge MS Sheet capable of accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. CO2 & 1 No. Dry podwer type portable fire extinguishers & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & \\"FIRE HOSE\\" written on front. (Approx. size of door: 2100 mm HEIGHT, WIDTH OF DOOR AS PER SHAFT SIZE ) |
| 337 | Providing and fixing hose cabinet of size 750mmX600X250mm made of 16 gause thick MS sheet with 4 mm thick float glass doors in front painted \\"FIRE\\" in red paint i/c recessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15 mtr. long hose pipe. 1 no. brach pipe mounted on wall or raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant. as directed by Engineer-in-Charge. |
| 338 | Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges. 80 mm dia |
| 339 | Supply and fixing of 4 Nos G.I round bottom FIRE BUCKET of 9 LTR. Capacity field with stand including proper supporting /mounting arrangement MS Angle Iron Frame painted by fire red colour over 2 coats of red oxide paint and written with white paint FIRE complete in all respects as per direction of Engineer Incharge . |
| 340 | Providing and fixing of 4.5 Kg. carbon-di-oxide type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase ingernal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming ro IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with internal charge. |
| 341 | Providing and fixing 6.0 Kg. ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with inernal charge. |
| 342 | Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:13386 . |
| 343 | Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEY confirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285. |
| 344 | Providing and fixing 2 kg capacity clean agent-HFC 236FA Stored Pressure type fire extinguisher ISI marked under IS:15683 complete with imported Novec 1230 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and Restrictions. |
| 345 | Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. |
| 346 | Supply, Installation, testing & Commissioning of DX type split AC units with air cooled condenser mounted in outdoor unit complete with scroll /rotary compressor ,condensor,wiring & accessories.Indoor units shall be wall mounted type complete with evaporator,fan,filter,drier, expansion devices & microprocessor control panel along with all accessories with refrigerant & oil charge,cordless remote controls.The unit shall be suitable for working,50 cycle /second ,1 phase AC supply .The unit shall be designed to take care of veritcal head 10mt & horizontal length of 15 mt & necessary oil seprator shall be included,Necessary supporting arrangement for both indoor & outdoor units ( Powder Coated /Epoxy painted MS stand for ODU units as per approved make shade by Architect)with necessary vibration isolation arrangement as per site condition etc.( without condensate drain pipe ,electrical pipe ,electrical power & control cabling between indoor & outdoor unit which shall be paid seprately ). The Color of the outdoor units to be finalized by the Architect as per building Architectural elevation. All Unit shall be Minimum 3 Star Rating Based The Outdoor unit Compressor must be provided with 1 Year Warranty Period. Dust Filter Civil Work such as wall hole making , wall chiseling, refilling of chiseling part with mortar etc as per site condition. Nitrogen pressure testing for leakages & flushing during piping installation & after commissioning between IDU & ODU with flar nuts Removable Covers for all indoor & Outdoor units shall be supplied & put on the units after installation & commissioning. Incoming power supply shall be provided near each indoor units Sound level of Outdoor unit shall be 70 Db at 1 Mt Distance Drain pump Voltange Stabilizer (V Guard Make) MAKE: DAIKIN/MEI/SAMSUNG HI WALL UNITS v |
| 347 | Same as above but 2.0 TR HI WALL Split |
| 348 | Supply, installation, testing and commissioning of Propeller Type Heavy Duty Exhaust Fan complete with bird screen,gravity louvers, metal clad MCB & starter,5m length copper cable, earthing wire all compete as required, suitable for single phase, 230 volts, 50Hz AC. supply of following capacities: 1x200 MM Dia Propeller Fan |
| 349 | Supply,installation,testing and commissioning of ceiling suspended with abs body Inline fans with Multi speed controller complete with bird screen, rain guard, metal clad MCB & starter ,5m length copper cable, earthing wire all compete as required of following capacities and shop drawing mentioned. MAKE: GREENHECK/SUNON 1000 CFM ,20mm St.Pr. |
| 350 | Supply, installation, testing and commissioning of copper refrigerant piping (Two Length) duly insulated with 9mm thick nitrile rubber of Class \\"O\\" between the above indoor & outdoor units as shown on drawing enclosed .with necessary supports etc 1/4 inch & 3/8 for 1TR , 1/2 inch &1/4 for 1.5TR & 2TR . 1.5 TR Hi Wall Unit |
| 351 | Same as above but 2.0 TR Hi Wall Unit |
| 352 | Providing and fixing U-PVC pipe with fittings of 10 kg /cm3. with 6mm thick Nitrile rubber of Class \\"1\\" inculding all fittings and jointing with solvent cement and , including cutting holes in walls ,wherever required and making good the same, complete as directed by the Engineer in charge. 25 mm Dia. of pipe OD |
| 353 | same as above but 32 mm Dia. of pipe OD |
| 354 | Supply and laying ,testing and commissioning of following sizes of Copper conductor control cables with PVC conduit & fixing clamps and effecting proper connections to equipment etc. of following sizes : POWER CUM CONTROL CABLING FOR UNITS 4C X 2.5 sqm or as per manufacture Std of units |
| 355 | Supply, installation, testing and commissioning of 1 No. 10 Passenger Machine Room Less (MRL) Elevator, 680 Kg capacity, 1.0 MPS speed, 3 stops with automatic centre opening doors, complete with stainless steel cabin, LED lighting, control panel, safety devices, wiring and all accessories, including testing, commissioning and 12 months warranty & maintenance, complete as per approved specifications and manufacturer standards. (MAKE-KONE,SCHINDLER) |
| 356 | RETRO REFLECTIVE SHEET OF MICRO PLASTIC GRADE CONFIRM TO IRC TO-67 2022 & TYPE XI STANDARD OF ASTM D4956-09 SPECIFICATION WITH 2 MM ALLUMINIUM SHEET OR 4 MM THICK ALLUMINIUM COMPOSITE PANNEL . HIGH RESULATION UV-STABILIZED PRINTING OF TEXT ,SYMBOL AND A UNIQUE QR CODE .SIGNAGE (MR) |
| 357 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 358 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 359 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 360 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete prepared with batch mixing machine |
| 361 | Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) per cm depth per cm width per metre length |
| 362 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia |
| 363 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia |
| 364 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.ection of Engineer -in-charge. 100 mm nominal size dia |
| 365 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia |
| 366 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 367 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 100 mm dia |
| 368 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 100 mm clamp. |
| 369 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 100 mm dia. |
| 370 | Providing and fixing G.I Pipe including G.I Fittings including trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 65 mm nominal dia Pipes |
| 371 | Sypply and Installation of 100-120 LPM Submersible Pump Set of 7.50 H.P. capacity, K.S.B. Make including Starter panel, support wire, A. Meter etc. complete. |
| 372 | Supply and fixing of nylon jali around the slotted pipes complete as required. up to 10 meter |
| 373 | Sypply and laying of alluminium conductor pvc insulated Submersible cables 1100 volts grade 4 SQ.MM 3-1/2 core |
| 374 | Water testing chemical and bactriological of Tubewell as per direction of E/I Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail