| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 min width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides andramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth asdirected: All kinds of soil : |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level. 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) Crushed . |
| 3 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. Layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m. |
| 6 | Dumping of stone in Horizental on level including the cost of stone complete job. |
| 7 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) & Extra for brick work with common burnt clay bricks /cement concrete bricks in superstructure above plinth level upto floor five level. |
| 8 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) & Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts ans sturts, etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded crushed stone aggregate 20mm nominal size). |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 11 | Reinforcement for RCC work including straightening cutting, bending, placing in position & binding all complete with TMT bars. |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns |
| 13 | Centring and Shuttering including strutting, propping etc and removal of form work for Suspended floors, roofs, landings, balconies and access platform. |
| 14 | Centring and Shuttering including strutting, propping etc and removal of form work for Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 15 | Centring and Shuttering including strutting, propping etc and removal of form work for Lintels, beams, plinth beams, girders,bressumers and cantilevers. |
| 16 | Centring and Shuttering including strutting, propping etc and removal of form work for Edges of Slabs and Break in floors and walls (Under 20 cms wide). |
| 17 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): (Sal Wood). |
| 18 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cemen concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 gradedstone aggregate 20 mm nominal size). |
| 19 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to openings / wooden frames with rawl plugs screws etc. |
| 20 | 6 mm Cement plaster to ceiling of mix 1 : 3 ( 1 cement : 3 fine sand). |
| 21 | 15mm cement plaster of mix 1:6 (1 cement : 6 fine sand). |
| 22 | 12mm Cement plaster on the rough side of single or half brick wall of mix 1 : 6 ( 1 cement : 6 fine sand). |
| 23 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 24 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). 35mm Thick (Second class Kail wood). |
| 25 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Particle Board 12mm thick Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked. |
| 26 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 35mm thick (Second class Kail wood). |
| 27 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class Kail wood |
| 28 | Providing and fixing sliding door bolts ISI marked oxidised transparent or dyed to required colour or shade with nuts and screws etc. complete :250x16 mm. |
| 29 | Providing and fixing ISI marked oxidized M.S. tower bolt with necessary screws etc. complete 150x10 mm. |
| 30 | Providing and fixing ISI marked oxidized M.S. tower bolt with necessary screws etc. complete 100x10 mm. |
| 31 | Providing and fixing ISI marked oxidized M.S. handles with necessary screws etc. complete.125 mm. |
| 32 | Providing and fixing ISI marked oxidized M.S. handles with necessary screws etc. complete.100 mm. |
| 33 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer. |
| 34 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm). |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work. |
| 36 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre |
| 37 | Providing & fixing electric points complete in all respect as per necessary as site. |
| 38 | Carriage of materials by mechanical transport including loading / unloading and stacking complete. Sand lead up to 45 kms avg. |
| 39 | Carriage of materials by mechanical transport including loading / unloading and stacking complete. Stone aggregate lead up to 40 kms avg. |
| 40 | Carriage of materials by mechanical transport including loading / unloading and stacking complete. Bricks lead up to 240 kms avg. |
| 41 | Carriage of materials by manually including loading / unloading and stacking complete. Sand lead up to 300 mtr avge. By H.L. |
| 42 | Carriage of materials by manually transport including loading / unloading and stacking complete. Stone aggregate lead up to 300 mtr avge. H.L. |
| 43 | Carriage of materials bymanually transport including loading / unloading and stacking complete. Bricks lead up to 300 mtr avge. H.L. Please Enable Macros to View BoQ information |