| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 2 | Providing and laying of stone soling in trenches hand packed all inclusive leads, lifts, loading, unloading, head load, ramming/ dressing and carriage of materials from approved nearest sources to site of work . Complete job. |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 10 | Foundations, footings, bases for columns etc for mass concrete |
| 11 | Stairs (excluding landings) except spiral staircases. |
| 12 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 13 | Suspended floors, roofs, landings, balconies and access platforms. |
| 14 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 15 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 16 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 2 mm thick |
| 17 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer. |
| 18 | Supply and filling of stone Dust/GSB/Nallah Muck in rooms including spreading, levelling, watering, ramming and consolidation, etc complete including all carriages of the same from approved source upto site of work including 50m head load. complete job |
| 19 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): first class KD wood |
| 20 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 21 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws fIRST class KD wood. 35mm thick |
| 22 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge :First class KD wood 35mm thick |
| 23 | Providing and fixing panelling or panelling and glazing shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws incl. Panelling or panelling and glazing of required size all complete as per direction of Engineer-in-charge.fIRST class KD wood. 35mm thick |
| 24 | Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 25 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 26 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete Welded |
| 27 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.50 mm thick with zinc coating not less than 275 gram/m2 including ridges and valleys, hips, sofit and eaves boarding complete job as directed by EIC. |
| 28 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 29 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 30 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 31 | Providing and Fixing PVC Pipes and sanitary Fittings of Approved Brand(Type-B) Including Cost of Labour Charges for Cutting of Wall/Floor incl.laying in proper gradient and fixing in position complete job. 4\\" dia |
| 32 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes with fittings and the base support for tank |
| 33 | Providing, installation, commissioning and testing Hot water Geyser of approved make (Venus, Racold, Jaguar or equivalent) including all fittings and fixtures, including cost angle valves, connection pipes, etc and making necessary connections. 50 litre capacity. Complete job as directed by EIC. |
| 34 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 35 | Providing and fixing of floor Trap (100 mm) of approved brand and manufacture complete job as per directions of EIC. |
| 36 | Providing and fixing of CP floor grating (100 mm) of approved brand and manufacture complete job as per directions of EIC. |
| 37 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in charge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. |
| 38 | PN-16 pipe , 25mm OD(SDR-7.4) |
| 39 | PN-16 pipe , 32mm OD(SDR-7.4) |
| 40 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Medium pipe 40 mm dia incl cutting and making good walls and ceiling for waste pipes, bath wastes, overflow,kitchen euipments waste connections and condensate drainage as per directions of EIC. |
| 41 | Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand), 200mm thick foundation concrete 1:4:8 mix (1 cement : 4 coarse sand; 8 graded stone aggregate 40mm nominal size), inside and outside plastering 12mm thick with cement mortar 1:3 (1 cement:3 coarse sand), finished with a floating coat of neat cement inside and rough plaster on outside and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size), neatly finished complete as per standard design including excavation, refilling and disposal of surplus earth.Inside dimensions 455x610 mm and 45 cm deep,including Providing and fixing SRFC Manhole covers as required,complete job |
| 42 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm |
| 43 | Providing and fixing of Sink mixer of approved brand and manufacture complete job as per directions of EIC. |
| 44 | Providing and fixing 32 mm nominal bore C.P. brass ball cock of approved quality and brand incl all fittings complete job as per directions of EIC. |
| 45 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 46 | Providing & Fixing 25/32 mm Dia PVC Conduit Pipes,Junctions included embedded fixtures / Boxes etc for electric fittings including embedding all complete job |
| 47 | Providing and Fixing of Hardware fittings of approved make and manufacture incl. cost of all fittings and Fixtures/fixing material as per directions of EIC complete job. |
| 48 | Handles 6\\" size |
| 49 | T-Bolt 6\\" size |
| 50 | L-Drop( 200mm) |
| 51 | Providing and fixing PPR Ball Valve of full flow of approved quality and brand incl all fittings complete job as per directions of EIC. |
| 52 | Carriage of materials from approved source to site of work including loading unloading complete. |
| 53 | Stone Aggregates to site from nearest source for an average lead of 30 Km |
| 54 | Sand from nearest source to site for an average lead of 25 Km |
| 55 | Bricks from nearest source an average lead of 25 Km Please Enable Macros to View BoQ information |