| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | SITE CLEARANCE |
| 3 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees andsaplings of girth up to 30 cm measured at a height of 1 m above ground level andremoval of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 4 | EARTHWORK EXCAVATION |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 7 | PLAIN CEMENT CONCRETE |
| 8 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 9 | Providing and laying in position machine batched and machine mixed design mix M30 grade cement concrete for reinforced cement concrete work, using cement contentas per approved design mix, including pumping of concrete to site of laying butexcluding the cost of centering, shuttering, finishing and reinforcement, includingadmixtures in recommended proportions as per IS: 9103 to accelerate, retard settingof concrete, improve workability without impairing strength and durability as perdirection of Engineer - in-charge.All work upto plinth level. |
| 10 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 11 | FORMWORK |
| 12 | Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform |
| 13 | Centering and shuttering including strutting, etc. and removal of form for:Walls (anythickness) including attached pilasters, butteresses, plinth and string courses etc |
| 14 | MASONRY WORK |
| 15 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etccomplete. |
| 16 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 17 | PLUMBING WORK |
| 18 | Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 |
| 19 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 10 Kfg/cm - Internal work- Exposed on wall |
| 20 | Providing and fixing in position Pre-cast R.C.C. manhole cover and frame of requiredshape and approved quality.L D - 2.5Rectangular shape 600x450 mm internal dimensions |
| 21 | Providing and fixing CP grating of 6mm thick with rim including setting in floor withwhite cement mortar and making good the floor :125 mm dia |
| 22 | STEEL WORK |
| 23 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoidscratches during transportation and should be supplied in single length upto 12 metreor as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/selftapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch inhorizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required. |
| 24 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes |
| 25 | Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.)trusses etc., including cutting, hoisting,fixing in position and applying a priming coatof approved steel primer, including welding and bolted with special shaped washersetc. complete |
| 26 | Providing and fixing fire resistant door frame of section 143x57 mm having built inrebate made out of 16 SWG G.I. sheet ( zinc coating not less than 120 gm/ sqm) dulyfilled with vermuculite based concrete mix, suitable for mounting 60 minutes firerated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4mm (minimum) alround the frame and fixing with dash fastener of approved size andmake, including applying a coat of approved brand fire resistant primer etc. completeas per direction of Engineer -in-charge (Dash fastener to be paid for separately ). |
| 27 | Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes firerating conforming to IS : 3614 (Part - II), tested and certified as per laboratoryapproved by Engineer-in-Charge, with suitable mounting on door frame, consisting ofvertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of16 SWG G.I. sheet (zinc coating not less than 120 gm/m2) duly filled FR insulationmaterial and fixing with necessary stainless steel ball bearing hinges of approvedmake including applying a coat of approved fire resistant primer etc. all complete asper direction of Engineer -in-charge ( panneling to be paid for separately). |
| 28 | Providing and fixing panic bar / latch (Double point ) fitted with a single body, TrimLatch & Lock on back side of the Panic Latch of reputed brand and manufacture to beapproved by the Engineer -in-charge, all complete. |
| 29 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approvedsteel primer all complete. |
| 30 | PAINTING |
| 31 | Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Two or more coats applied on walls @1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm |
| 32 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. Thecrystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of theengineerincharge. The product performance shall carry guarantee for 10 years against anyleakage.For vertical surface two coats @0.70 kg per sqm |
| 33 | Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. Thecrystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of theengineerincharge. The product performance shall carry guarantee for 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm. |
| 34 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe MultiSurface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqmover an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 35 | Electrical |
| 36 | POINT WIRING |
| 37 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 38 | SUBMAINS |
| 39 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 40 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 41 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 42 | PLUG POINTS |
| 43 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6amps switch |
| 44 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 45 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 46 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 47 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 48 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 49 | DB AND ACCESSORIES |
| 50 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door |
| 51 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 52 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current breaker with overload (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required up to 40A, 2P, 30mA |
| 53 | CABLING AND TERMINATION |
| 54 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 185 sq mm |
| 55 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 185 sq mm |
| 56 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm |
| 57 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm |
| 58 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm |
| 59 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 6 sq mm with factory made clamp |
| 60 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm) |
| 61 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm) |
| 62 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) |
| 63 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 6 sq. mm (22mm) |
| 64 | DG AND ASSOCIATED WORKS |
| 65 | 200KVA DG SET WITH AMF PANEL - Supply, Installation, Testing and Commissioning of ‘Silent Type’ Diesel Generating set of CPCB IV Norms along with having Prime Power Rating of 200 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of Diesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories and Synchronous alternator rated at 200 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class- F/H insulation, Including CPWD/EI/EB approved AMF panel, Base Frame, Fuel Tank, Battery with leads and other accessories with type competent approved Canopy as a complete set. Contractor has to arrange load test at site or at factory without any additional cost or claim. Including First fill of lube oil and Engine safeties – LLOP, HWT, Initial filling of diesel for standard testing procedure up to 6 hours minimum and 12 hours maximum. |
| 66 | Supply, erection, commissioning of additional length of exhaust pipes with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other accessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for installation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building within 10m radius of the exhaust. 300 mm dia |
| 67 | Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm |
| 68 | Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 2.50 sq mm |
| 69 | Thermal insulation for DG Exhaust piping including silencer with glass wool insulation and aluminum cladding, cladding shall be done with minimum 22SWG |
| 70 | SUB PANEL |
| 71 | SUB PANEL: Fabrication, supply, erection, testing and commissioning of floor or wall mounting dust and vermin proof, cubicle type, front operated MV panel board as per IS 8623 - CPRI Certified made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components. The panel shall be with Top/bottom entry to receive incoming & outgoing, all opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. Incomer - 320A 36kA FP Microprocessor based MCCB having isolation duty , isolation duty type 320A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Multifunction meter having multiline LED display with following parameters -Phase wise instantaneous and Average values?Voltage, Current, Power Factor, Phase wise instantaneous and Average values?Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values? Active Energy, Reactive Energy lead & lag, Apparent Energy, PF for 3 phases and average, Instantaneous Frequency, Total Harmonics Distortion ? Phase wise Voltage and Phase wise Current- 1 Set RYB phase indicating LED lamps with control fuses and switches - 1 set. Outgoings: 250A 25kA TP MCCB Thermal Magnetic based - 1 nos, 160A 25kA FP MCCB Thermal Magnetic based - 1 nos, 100A 25kA FP MCCB Thermal Magnetic based - 2 nos. |
| 72 | EARTHING |
| 73 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 74 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 75 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 76 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 77 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 78 | FITTINGS |
| 79 | Supply of 4 feet surface/suspended mounted LED batten type luminaire with a power consumption not more than 20 W, luminaire lumen output of 2000 lumens, luminaire efficacy > 100 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall be made of extruded PC housing, efficient poly carbonate diffuser to provide uniform illumination and wider light distribution. The luminaire shall have a CCT of 4000K /6500 K. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. Including all accessories necessary as required to complete installation. |
| 80 | DOCUMENTATION AND APPROVAL |
| 81 | DOCUMENTATION AND APPROVAL \\"Charges for Preparation of all drawings submitting and getting approval from Electrical Inspectorate, submitting of Completion certificates and arranging inspection, getting sanction and energisation certificates from Electrical Inspectorate & KSEB, obtaining power allocation & power connection etc. for commissioning of the whole installation. All statutory payments will be reimbursed on production of the original receipts. (for modification works) |
| 82 | FIRE FIGHTING |
| 83 | PUMP AND PANEL |
| 84 | a)Supplying,installation,testing and commissioning of Electric driven Main Fire Pump suitable for Automatic operation and consisting of following, complete in all respect , as required : b) Horizontal type, Multi stage ,centrifugal, split casing Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520. C) Suitable HP Squirrel Cage Induction Motor, TEFC, Synchronous speed 1500rpm suitable for operation on 415 V 3 phase 50 HZ AC supply with IP55 Protection for enclosure ,horizontal foot mounted type with class F insulation, conforming to IS 325. d) M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required. e) Suitable cement concrete foundation duly plastered with Anti vibration pads 2280 lpm at 70 m head |
| 85 | a)Supplying,installation,testing and commissioning of Diesel Engine driven Main Fire Pump suitable for Automatic operation and consisting of following, complete in all respect , as required :(Diesel Driven Pump) b) Horizontal type, Multi stage ,centrifugal, split Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520. C) Suitable HP ,1500rpm,water cooled with radiator,diesel engine conforming to relevant IS standard complete with auto starting mechanism 12/24 V Electric starting equipment,diesel tank, exhaust pipe extended upto 10m outside pump house duly insulated with 50 mm thick glass wool with 1 mm thick Al sheet cladding residential silencer, instruments and protection as per standard specifications, stop solenoid for Auto stop in the event of fault with audio indications, painted with post office red colour etc as required. d) M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required. e) Suitable cement concrete foundation duly plastered with Anti vibration pads2280 lpm at 70 m head |
| 86 | a)Supplying, installation, testing and commissioning of Electric driven Pressurisation Pump suitable for Automatic operation and consisting of following, complete in all respect , as required :(Jockey Pump) b) Horizontal type, Multi stage ,centrifugal, split casing Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520. C) Suitable HP Squirrel Cage Induction Motor, TEFC type suitable for operation on 415 V 3 phase 50 HZ AC supply with IP55 Protection for enclosure ,horizontal foot mounted type with class F insulation, conforming to IS 325. d)M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required. e) Suitable cement concrete foundation duly plastered with Anti vibration pads180 lpm at 70m Head |
| 87 | Fabrication, supply, installation, testing and commissioning of Electrical Control Panel of cubicle construction Floor mounted type fabricated out of 2 mm thick CRCA sheet compartmentalised with hinged lockable doors, dust vermin proof, powder coated of approved shade after 7 tank treatment process cable alleying interconnection with suitable size copper conductor cable or solid copper strip having switchgearsand accessories, mopuntigs and internal wiring, earth terminals, numbering etc., complete in all respects suitable for main fire pump , pressurisation pump and diesel pump set complete as per CPWD specification with following incoming and outgoings suitable for operation of 415 V, 3 phase, 50 Hz, AC supply with enclosure protection class IP 42 as required: INCOMING : 250A, 50kA 4P MCCB ,Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter 0-250A with selector switch and CTs etc. LED Type RYB phase indicating Lamps ,ON/OFF, Trip indicating lamps set of Cu Bus Bar 300A . OUT GOING :(Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) MAIN FIRE PUMP: 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. JOCKEY PUMP : 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROL: Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump,Terrace pump in sequence as per specification consisting of relays, timers. Sensors,annunciation window for fault indication, complete as per specification |
| 88 | Supply, installation, testing and commissioning of lever operated 25mm dia Gate/ball valve conforming to IS 9890:1981 with forged body, brass/stainless steel ball and shall be internally threaded to receive pipe connections 25mm dia |
| 89 | Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters FIRE in black and gold. Cost shall be inclusive of providing MS stand for 2 nos of fire buckes, or , duly painted over a coat of primer. |
| 90 | PIPES,VALVES AND ACCESSORIES |
| 91 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:25 mm dia |
| 92 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:50 mm dia |
| 93 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:80mm dia |
| 94 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:100mm dia |
| 95 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:150mm dia |
| 96 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:200mm dia(Wall thickness 6.3mm) |
| 97 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 1239/3589 i/c fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., in ground including welding ,excavation and providing cement concrete blocks as supports, Anti corrosive treatment with coal tar ,Asphalt type as per IS 10221, refiiling the trench etc., of following sizes150 mm dia |
| 98 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:80 mm dia |
| 99 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:150 mm dia |
| 100 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:200 mm dia |
| 101 | Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.80mm dia |
| 102 | Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.150mm Dia |
| 103 | Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates,pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipeof required size, flanges, orifice plate, gasket etc of follwing sizes as required: 150 mm dia |
| 104 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required |
| 105 | supplying and fixing air vessel made of 250 mm dia 8 mm thick MS sheet , 1200 mm in height with Air release valve on top and flanged connection to riser , drain arrangement with 25 mm dia Gun metal wheel valve with required accessories , pressure guage and painting with synthetic enamel paint of approved shade as required. |
| 106 | Providing and fixing of pressure switch in MS pipeline including connection etc as required: |
| 107 | Providing and fixing of flow switch in MS pipe including connection etc as required:150 mm dia |
| 108 | Providing, installation ,testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel , Grade 304,sheet with3 mm dia holes with stainless steel flange.200 mm dia |
| 109 | Providing fixing SS fire brigade suction hose coupling (draw-out connection) with nut for female coupling as per IS standards complete with built-in check valves,with65 mm dia flanged outlet complete with bolts, nuts and rubber insertions as requiredand as per IS standards |
| 110 | FIRE BRIGADE INLET : Supply, installation, testing and commissioning of 3 way tank filling Inlet connection of 63 mm dia. valves instantaneous coupling type arrangement to be connected to wet riser main. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail