| 1 | Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and gravel mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge-Upto 1.5mtr Depth |
| 2 | Beyond 1.5mtr to 3.00 mtr Depth |
| 3 | Filling the Foundation and Plinth, Sides of Foundation, etc. with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge-Ground Floor |
| 4 | Disposal of surplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as per the direction of the Engineer-in-charge-Ground Floor |
| 5 | Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge.( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work. |
| 6 | Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. -Ground Floor |
| 7 | Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge- Ground Floor |
| 8 | Beyond 1.5 M to 4.5M Depth |
| 9 | Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 Including the cost of Centering and Shuttering (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement.-R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc-Beyond 1.5 M to 4.5M Depth |
| 10 | R.C.C. Plinth Beam- Ground Floor |
| 11 | R.C.C. Beams, columns, grider and bressmer etc.- Ground Floor |
| 12 | First Floor |
| 13 | Second Floor |
| 14 | Terrace Floor |
| 15 | R.C.C. Floor and Roof slab, landing, balconies,Projecting sun shades and chajjas up to 4.3Mtr. Height.- Ground Floor |
| 16 | First Floor |
| 17 | Second Floor |
| 18 | Terrace Floor |
| 19 | R.C.C. stairs excluding landing but including railing.- Ground Floor |
| 20 | First Floor |
| 21 | Second Floor |
| 22 | R.C.C. Lintel: Ground Floor |
| 23 | First Floor |
| 24 | Second Floor |
| 25 | Terrace Floor |
| 26 | R.C.C. walls and fins including attached pillasters.: Ground Floor |
| 27 | Providing & fixing TOR Fe-500 HYSD Reinforcement bars of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge.Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment)-Ground Floor |
| 28 | First Floor |
| 29 | Second Floor |
| 30 | Terrace Floor |
| 31 | Providing and laying Brick Masonry work in Foundation & Plinth using Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge.-Ground Floor |
| 32 | Providing and laying Brick masonry work in Superstructure using Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:4) for Half Brick Masonry Wall with provisions for 2 nos 6mm dia MS bar at each 4th layer after immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. ( Excluding Cost Of Steel Reinforcement -Ground Floor |
| 33 | First Floor |
| 34 | Second Floor |
| 35 | Providing and laying of Full Brick Masonry work in Superstructure using Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge.-Ground Floor |
| 36 | First Floor |
| 37 | Second Floor |
| 38 | Terrace Floor |
| 39 | Providing 6 mm thick Cement Plaster in Cement Mortar of (1:4) to Ceilings of Roof Slabs, Stairs, Landings, Chajja, Shelves, Columns, Beams and Lofts etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing , sundries, T&P etc. complete as per direction of the Engineer-in-charge-Terrace Floor |
| 40 | Providing 12mm thick cement plaster in cement mortar (1:4) to the surface of half brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge.-Ground Floor |
| 41 | First Floor |
| 42 | Second Floor |
| 43 | Providing 12mm thick Cement Plaster to the Surface of Brick Masonry Wall in Cement Mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge.(Inside Even Surface)-Ground Floor |
| 44 | First Floor |
| 45 | Second Floor |
| 46 | Terrace Floor |
| 47 | Providing 16mm thick cement plaster in cement mortar (1:6) to the surfaces of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. (Inside Uneven Surface)-Ground Floor |
| 48 | First Floor |
| 49 | Second Floor |
| 50 | Providing 18mm thick cement plaster on external surfaces of brick surfaces in two coats consisting of under layer 12mm thick in CM 1:6 (1 cement : 6 coarse sand) and top layer of 6mm thick cement plaster 1:4 ( 1 cement : 4 coarse sand) mixed with integral water proofing material of including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge.-Ground Floor |
| 51 | First Floor |
| 52 | Second Floor |
| 53 | Terrace Floor |
| 54 | PLINTH PROTECTION-Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated approved design mix Reinforced Cement Concrete of grade M-20 in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality, size and grading obtained from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of all labour, conveyance, royalty, loading, unloading, watering, curing, sundries, hire & running charges of machineries, cost of admixture in recommended proportions ( as per IS 9103 ) to retard/accelerate the setting time of concrete, improve workability without imparting the strength and durability, etc. all complete as per the direction of the Engineer-in-charge.(but excluding the cost of reinforcement, centering and shuttering.)Ground Floor |
| 55 | Providing average 25mm thick grading Concrete in C.C (1:2:2 ) using 6mm size crusher broken black hard granite chips using 2% water proofing cement compound (Make: Sika / Fosroc / Equivalent) after scraping and cleaning the roof surface and finishing smooth to proper slope and gradient including cost of all materials, conveyance, sundries,T&P watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge.-First Floor |
| 56 | Terrace Floor |
| 57 | FINISHING WORK- Supplying and finishing the plastered surface of wall using Cement Based Wall Putty (Water Based) of approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge.(Make: Birla White/J K Wall Putty)-I. Internal Walls-Ground Floor ( External +Internal) |
| 58 | First Floor |
| 59 | Second Floor |
| 60 | Terrace Floor |
| 61 | First Floor |
| 62 | Second Floor |
| 63 | Terrace Floor |
| 64 | Providing and applying Two Coats Plastic Emulsion Paint of approved make, quality and shade over a coat of wall primer of approved quality to the internal plastered surfaces including throughly brushing the surface to make free from foreign materials, sand papering, priming including cost of all materials, cost of all labour, conveyance, loading, unloading, scaffolding, staging, watering and curing, T&P etc. complete as per the direction of the Engineer-in-charge.(Note: Colour & shade to be approved before procurment & use).(Make:Dulux/Nerolac/Berger/Asian Paint)-Ground Floor |
| 65 | First Floor |
| 66 | Second Floor |
| 67 | Providing and Painting with Two Coats Weather Coat Paint (exterior grade) of approved make & shade manufactured by reputed manufacturer make an even finished surface over a coat of water bound cement primer and wall putty in all heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete.-Ground Floor |
| 68 | First Floor |
| 69 | Second Floor |
| 70 | Terrace Floor |
| 71 | Providing and painting Two Coats of Synthetic Enamel Paint of approved quality, brand and shade over a coat of red oxide primer to Iron Work including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. (Note: Colour & shade to be approved before procurment & use).(Make:Dulux/Nerolac/Berger/Asian Paint)-Ground Floor |
| 72 | First Floor |
| 73 | Second Floor |
| 74 | Terrace Floor |
| 75 | FLOORING WORK-Providing and laying of 600 mm x 600 mm Matt Finished Vitrified Floor Tiles confirming to IS : 15622 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) (Make:Somany/Jhonson/RAK/Kajaria)-Ground Floor |
| 76 | First Floor |
| 77 | Second Floor |
| 78 | Providing and laying of Vitrified Tiles in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 600mm x 600mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.)-Ground Floor |
| 79 | First Floor |
| 80 | Second Floor |
| 81 | Providing & laying granite stone flooring using 20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 in Stair Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade with typical half nosing and cutting grooves etc including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge. (Colour: Tan Brown)(Note- Sample of granite tiles shall be approved before procurement and use.) -Ground Floor |
| 82 | First Floor |
| 83 | Second Floor |
| 84 | Providing & laying granite stone flooring in Floors and landing using 20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of granite tiles shall be approved before procurement and use.) -Ground Floor |
| 85 | First Floor |
| 86 | Second Floor |
| 87 | Terrace Floor |
| 88 | Providing & laying granite stone tiles in dado/skirting using 10mm thick granite stone slab of approved quality, colour and size upto 0.4 Sqm as per IS 14223 to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to IS IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of granite tiles shall be approved before procurement and use.) -Ground Floor |
| 89 | First Floor |
| 90 | Second Floor |
| 91 | Terrace Floor |
| 92 | Providing 25 mm thick A.S. flooring with base C.C. (1:2:4) using 20 mm size hard granite crusher broken chips after roughening, scraping, cleaning the base, watering well and laying flooring to required level in panels 2m x 2m (Max.) by using dividing glass strips of 40 x 4 mm size, well compacted and top finishing smooth by trowel with a thick coat of neat cement punning, polished well including cost of all materials, labour, conveyance, sundries, T&P, curing etc. complete as per direction of Engineer-in-Charge.-Terrace Floor |
| 93 | Providing & laying kota stone slabs in floors using 16 mm thick kota stone slab of approved quality, colour and size above 0.4 Sqm laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement : 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.)-Ground Floor |
| 94 | First Floor |
| 95 | Second Floor |
| 96 | Providing & laying kota stone slabs in dado/Skirting using 16 mm thick Kota stone of approved quality, colour and size above 0.4 Sqm laid over an under layer of 12mm thick cement mortar (1:3) (1 cement: 3 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.)-Ground Floor |
| 97 | First Floor |
| 98 | Second Floor |
| 99 | Supplying, fitting & fixing of M.S Rolling shutter confirming to BIS specification as per approved design and drawing including cutting holes in brick/RCC surface and grouting the hold fasts/clamps properly in line and plumb with CC(1:2:4) using 12mm size black hard granite chips and making good to the damages including cost of all materials ,transportation, all labour, sundries, T&P and priming one coat with approved quality metal primer etc. complete as per direction of Engineer in charge.Ground Floor |
| 100 | Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.All Floor |
| 101 | Supplying,Installation of pressed Steel Doors of the specified dimensions and accessories such as hinges,door stopper,tower bolt, door handle ,door closer,dead lock,consedaled flush bolt,Shaft lock,martise lock and vision panel etc. complete as mentioned along with warranty covverage and after sales service etc.inclusive of all costs,taxes,GST,cost of delivery charges ,fixing,fittings and any other invidential charges etc.complete.4 Nos Hinges,1 No Door Stoppers,1 No Tower Bolt,1 No martise lock & Vision panel (Door Size 1200x2400) All Floor |
| 102 | Providing and fixing 65mm X 125mm factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.(Make: WPC Door Frame: Century/Black Cobra/Rajshri Plastiwood)Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.Terrace Floor |
| 103 | Providing and fixing of 30 mm thick factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with SS 304 Grade Matt Finished 3 Nos butt hinges of Size 100mm X 60mm X 2.5mm, 1 No 250mm X 16mm Aldrop,1 No 150mm x16mm tower bolt,2 No 150mm length Door handle with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Make: WPC: Century / Black Cobra / Rajshri Plastiwood, Hardware Fittings: Godrej / Dorset / Link / Dorma) Terrace Floor |
| 104 | Providing and fixing of 12mm thick Clear Toughened Glass Frameless Door With Dorma Premium Fittings.Dorma Premium (9111198) Unilite Package BTS 75,UL PT 10 with Cover,UL PT 20 with Cover,UL US 10 Luck with Cover and PT 24,Dorma Premium (9137121) H Type Handle 450mm,12mm Clear Toughened Glass with Cutout and Hole, including the cost of all materials, hardware fittings, cost of all labour, conveyance, loading, unloading, T&P, etc, complete as per the direction of Engineer-in-Charge.All Floor |
| 105 | Providing and fixing 12 mm thick frame less toughened glass partition Dorma Premium (911298) PT 90 Side Connector and PT 80 Glass to glass Connector with Silicone,12mm Clear Toughened Glass with Cutout and Hole,including perimeter sealing of glass to glass joints with silicon sealant ,etc.as per drawing and specification including the cost of all materials ,T&P,etc all complete as per the direction of Engineer-in-Charge. (Make: Dorma/Godrej)In all Floor |
| 106 | Supplying and installing Aluminium System - Fixed windows made out of ALUPURE/ WINPLUS/ ALTECH/REKLAD make frame dimension of 39mm x 42mm for with corners mechanical joints. Aluminium Systems are extruded through Billets with 6063 T6 Grade and 6mm thick toughen frosted glass with complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours due finishing techniques such as anodising and powder finishing. The system can accomodate Forsted glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of MCCOY /Dowcorning or equivalent. ORSupplying and installing Aluminium System - Openable windows made out of ALUPURE/ WINPLUS/ ALTECH/REKLAD make frame dimension of 39mm x 62.9mm & Sash dimension of 46mm x 92mm for with corners mechanical joints. Aluminium Systems are extruded through Billets with 6063 T6 Gradeand 6mm thick toughen frosted glass with complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate Forsted glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent.ORSupplying and installing Aluminium System - Sliding windows made out of ALUPURE/ WINPLUS/ ALTECH /REKLAD make frame dimension of 88mm x 40 & Sash dimension of 31mm x 61.5mm for with corners mechanical joints. Aluminium Systems are extruded through Billets with 6063 T6 Grade and 6mm thick toughen frosted glass with complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours due to finishing techniques such as anodising and powder finishing. The system can accomodate Forsted glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent.All Floors |
| 107 | Supplying, fitting & fixing of M.S. Grill made out of M.S. flats/square bars as per drawing and design fixed in position to proper plumb, including a coat of priming with approved quality metallic primer, materials including cost, conveyance, transportation of all materials, cost of all labour, sundries, T&P etc. complete as per direction of Engineer in charge. All Floors |
| 108 | S.S Railing:Supplying, fabricating & fixing of polished stainless steel (304 grade) items made out of pipes, angles, flats, plates, hollow tube, square pipe bracing as per approved design and specification, buffing, polishing etc. with cost, conveyance, labour in railing, parapet, staircase, space frame etc required for the work complete in all respect as per direction of Engineer-in-charge.For all Floor |
| 109 | Subhead- I (Internal Electrification)Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Make-Havells/Polycab/Finolex/RR Kable ) of ISI marked with 20 mm dia PVC heavy class FRLS non metallic conduit(Make-AKG/Polycab/precision/norpack/sudhakar) with 6A modular type switch(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) ) ISI marked , and ceiling rose ISI marked of modular type G.I box with cover , of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection .Raw power supply switch board shall be separate from emergency power supply switchboard as per direction of Engineer -in -Charge.Each light point should have provision for ceiling rose & angle holder point.Group-A: L.P= F.P= C.B.P= |
| 110 | Group-B: L.P= F.P= C.B.P= |
| 111 | Group-C: L.P= F.P= C.B.P= |
| 112 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 113 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. |
| 114 | Supplying and fixing including testing and commissioning of 6A modular socket outlet with 6 Amp switch including providing GI modular box with faceplate etc as required.Switch & socket: (modular type) (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) 1 nos 6 Amp 3-pin socket with 6 Amp switch. |
| 115 | 2 nos 6 Amp 3-pin socket with 2 nos 6 Amp switch. |
| 116 | Supplying,fixing of 16A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. |
| 117 | Supplying and installation of 25A AC starter Modular type or any other equivalent reputed make as approved coil voltage-415 Volt A.C. & O/L range of suitable range range on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .(Make-Legrand/Schneider/ Havells/ABB) |
| 118 | Receass wiring for circuit/submain wiring with the following mentioned size PVC insulated, copper conductor FRLS, single core cable (Make-Havells/Polycab/Finolex/RR Kable/KEI/Gloster) in recessed PVC FRLS conduit HEAVY duty (Make-AKG/Polycab/precision/norpack/sudhakar) of mentioned size as approved) as required as per direction of Engg.-in-Charge.. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT ) (2X2.5+1X1.5) |
| 119 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit .(BDB to POWER CKT ) (2X4+1X1.5) |
| 120 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic FRLS heavy duty PVC conduit .(PANEL TO SPDB ) (2X6+1X2.5) |
| 121 | 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) |
| 122 | 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(PANEL TO ACDB) (4X10+2X6) |
| 123 | SITC of recess/surface mounted 2'x2' 36 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make-panasonic/havells/LT/Bajaj/Phillips/Crompton/Wipro) . The luminaire must be Replacement Warranty will be 5years. |
| 124 | SITC of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coated sheet steel of 25W and system lumens output not less than 3250 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (2 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 2 years. |
| 125 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 126 | SITC of energy efficient LED tube light fittings with decorative alumunium LED batten along with LED tube light having power rating 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser i/c connection etc as required.The luminaire should be Replacement Warranty will be 2 years (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). |
| 127 | SITC of Energy efficient surface /recess mounted square /round shape 12 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 128 | SITC of surface Mounted Led bulk head Lighter comprising of 10W LED BULK HEAD LIGHTwith non integral / integral driver, 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy > 120 lm/W. LED driver PF 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer mandatory i/c connection wire, testing etc. to complete the job. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) |
| 129 | SITC of Energy efficient surface /recess mounted round shape 6 W LED spot luminaire of dimension of consists of white powder coated , die-cast Aluminium housing with high quality opal diffuser for glare-free uniform lighting distribution and lumen output of 660 lumens, CRI not less than 80,CCT of 6500 K,THD less than 10%, with electronic driver, internal surge protection of 2.5 KV , The fixture design should be with flicker free operations ripple <5%, L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.( TO BE USED FOR TOILET )(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 130 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 131 | SITC of Energy efficient surface /recess mounted square /round shape 9W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 9 watt and lumen output of 900 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 132 | Supplying, installation, testing and commssioning of BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery ≥ 215(m3/min) Make-USHA(Technix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .1200 mm sweep |
| 133 | Supplying of Exhaust fan / fresh air fan with louvre (Make -Crompton/ Orient/ Havells/Polycab) as required.200 mm sweep fibre body Exhaust air fan |
| 134 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers (MakeHavells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 135 | Supply,Installation, Testing & Commissioning of of 10 Passenger lift gearless with Machine room Capacity,Elevator G+3 Floors (Shaft size should not be less than-1750mm(Left to right)x1950mm(Front to back)) (Min. Car size-1300mmx1350mm, car opening should not be less than 800mm) with ACVVVF drive/Control for constant load of 680 kg ARD 1.25 MPS,all SS materials shall be of grade SS-304 with thickness not less than 1.6mm, SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc . Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cutting including Fireman's switch complete in all respect.The Elevator should be suitable for physically handicapped person. (MAKE:OTIS/Mitsubishi/Schindler)Serving four floors (G+1st to 2nd) & Travel 12.6 mtrs. |
| 136 | 20KVA UPS FOR ELV AND OFFICE ROOMSupply ,installation ,testing & commissioning of 20KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sicuency corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 32 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric / APC/ VERTIV) LOAD OF OT,ICU) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD. |
| 137 | BDBS,DB,AC DB,FLOOR PANELS,MCBSSupplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ ABB ITUS/LK -Exora-N as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.6 Way(8+12+18) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 138 | 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 139 | Supplying and fixing following rating RCBOs/ MCBs in the existing DB complete with connections,testing and commissioning etc. as required.Supplying and fixing 63Amps 4P 415 volts MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/LK in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years. |
| 140 | Supplying and fixing 40 Amps , 2P, 415 volts, RCCB breaking capacity 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/LK in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 141 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/LK in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 years.. |
| 142 | Supplying and fixing of following sizes of heavy gauge PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 143 | Supply and laying of 25/32mm U PVC trunking system and acessories.(Make:Legrand/MK(honeywell) |
| 144 | Providing and fixing extra down rod of 20 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored. |
| 145 | FIRE EXTINGUISHER SYSTEMSupply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex) |
| 146 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex) |
| 147 | Supplying, installation, testing and commissioning of Mechanical Foam type 9 litre capacity Fire Extinguisher, ISI marked, IS: 10204, containing 540 ml AFFF liquid ISI marked, IS: 4989 Part II and a polyurethane coated CO2 Gas Cartridge, ISI marked, IS: 4947 complete with gunmetal union cap, nylon hose with plastic foam making branch and wall mounting bracket.(Make: superimax/Cese fire/Minimax) |
| 148 | Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \\"FIRE\\" in black out side and handle with mounting bracket. |
| 149 | First Aid Box. |
| 150 | Shock Treatment Chart (Odia / Hindi & English). |
| 151 | 8 mm thick Rubber Mat. |
| 152 | Danger Board. |
| 153 | FIRE DOWNCOMERSupply,Installation,Testing & Commissioning of 'C' Class heavy duty MS pipe (as per IS 1239 upto 100 mm NB and IS 3589 for above 100 mm 6.33mm thick) with flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts of following size on surface along wall / shaft with MS bracket, suspended from ceiling/ beam with suspenders duly painted with two coats of primer and finished with enamel paint of approved colour laid through pipe or in trench after wrapping with hassen cloth after applying coal tar primer as required as per direction of Engineer-in- charge.Make-TATA/SAIL/JINDAL100 mm dia |
| 154 | 80 mm dia |
| 155 | 40 mm dia |
| 156 | Supply,Installation,Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge.Make-Newage/Minimax/Fireshield |
| 157 | Supply,Installation,Testing & Commissioning of 63 mm NB and 15meter long RRL Fire Hose fitted with 63mm intstantaneous stainless steel male & female SS coupling, complete by GI wire binding for Internal Hydrant as per direction of Engineer-in-charge. Make-Newage/Minimax/Fireshield |
| 158 | Supply,Installation,Testing & Commissioning of Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I., complete with all accessories as per direction of Engineer-in-charge. Make-Newage/Minimax/Fireshield |
| 159 | Providing, fitting & fixing of 2-Way GM fire brigade connection consisting of 63 mm dia instantaneous type male couplings with built-in check valves, 150mm dia flanged outlet complete with bolts, nuts and rubber insertions confirming to IS:904 with ISI mark including testing & commissioning the system etc. all complete as per apporoved specification & direction of EIC. Make-Zoloto/Audco/Leader |
| 160 | Providing and fixing GI earthing WITH strip 25mm x 6 mm From all motors and MCC panel to be connected in allapproved manner to general earthing system. Please Enable Macros to View BoQ information |
| 161 | Providing and fixing GI earthing WITH strip 25mm x 6 mm From all motors and MCC panel to be connected in allapproved manner to general earthing system. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail