| 1 | Surface dressing of the groundincluding removing vegetation and inequalitiesnot exceeding 15 cm deep anddisposal of rubbish, lead up to 50 m andlift up to 1.5 m. in all kinds of soil. |
| 2 | Disposal of building rubbish /malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all lead including all lifts involved. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in over areas foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 4 | Extra for every additional lift of 1.5 m or part thereof in. |
| 5 | Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : |
| 7 | Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. |
| 8 | Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cmdepth and dressing complete. |
| 9 | Supplying and filling in plinth with crusher stone dust/ coarse sand under floors including, watering, ramming consolidating in layers not exceeding 20cm in depth and dressing complete. |
| 10 | With 20mm nominal size graded stone aggregate. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 12 | Walls (any thickness) including attached pilasters butteresse s, plinth beams and string courses etc.up to plinth level |
| 13 | Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing reinforcement - All work up to plinth level |
| 14 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete .(Note:-1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3. Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) |
| 15 | Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg / cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete. |
| 16 | Making plinth protection 50mm thick of cement concrete grade M10 over 75mm bed of dry metal ballast 40mm nominal size well rammed and consolidated and filled with sand including finishing the top smooth (with 20mm nominal size graded stone aggregate.) |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 18 | Lintels, beams, girders, bressumers and cantilevers. |
| 19 | Suspended floors, roofs, landings, balconies and access platform. |
| 20 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses,fillets, columns, pillars, posts and struts su spended floor roof slab,beams, etc. up to floor two level excluding cost of centering,shuttering, finishing and reinforcement : |
| 21 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete .(Note:-1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3. Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) |
| 22 | Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg / cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc .complete |
| 23 | 12 mm cement plaster of mix : |
| 24 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 25 | 6 mm cement plaster of mix :CM 1:3 (1 cement: 3 sand) |
| 26 | Providing and laying vitrified floor tiles (widhout soluble salt) or prited (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS: 15622 of approved make in all colours & shades, 1st quality premium in flooring laid on 20mm thick cement mortar 1:4 (1 cement:4 sand) including grouting the joints with white cement and matching pigments etc, complete. |
| 27 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to I.S. 4454- part-1 and M.S. top cover of required thickness for rolling shutters. |
| 28 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators side /top /centre hung with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design (sectional weight of only steel members shall be measured for payment). |
| 29 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. |
| 30 | With ready mixed red oxide zincchromatic on steel/ iron works havingVOC content less than 250 grams/litre |
| 31 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, Like birla white /JK white or equivalent, over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. |
| 32 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: |
| 33 | Finishing walls by any mechanical ormanual means with water proofingcement paint of required shade:New work (Two or more coats applied @3.84 kg/10 sqm). |
| 34 | Painting with synthetic enamel paint ofapproved brand and manufacture to givean even shade: Two or more coats onnew work |
| 35 | Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. |
| 36 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. |
| 37 | Bend 87.5° |
| 38 | Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of bombay nail of required length including making good the wall etc. complete. |
| 39 | Point wiring (excluding metallic switch box & sheet but including switches,sockes,lamp,holders,ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :- |
| 40 | b) Primary Medium point |
| 41 | 3 Pin 6 Amp socket outlet on Separate Board |
| 42 | Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. Socket outlet point with 1.5 Sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board . |
| 43 | Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification |
| 44 | Supplying and fixing PVC conduit ISI marked along with the accessories in concealed system etc. as required |
| 45 | Supplying and fixing of approved make modular type metal box with modular frame/ base plate and cover plate including fixing in concealed / surface excluding switch,socket etc. as required for:- |
| 46 | 12 Module |
| 47 | Supply and fixing as per specification pendent holder ofapproved make including flexible cord up to 3 metre length withnecessary materials complete |
| 48 | Supply and fixing in position LED lamp of approved make |
| 49 | Supplying and fixing of approved make step type electronic Fan regulator including connection etc. as required on existing board |
| 50 | Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/1979 with up to date ammendments. |
| 51 | Supply and fixing Led tube rod comprising of LED tube with non integral / integral driver, 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy > 80 lm/W. LED driver PF 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer mandatory i/c connection wire, testing etc. to complete the job. 2 Yrs Guarantee certificate from manufacturer. |
| 52 | Supply and fixing street light with high power LED of 3 to 6 W eachon existing bracket assembled on single MCPCB, system lumensoutput with efficacy>120 lm/W. luminiare having color temp upto6500K & 50000 burning hrs. life with minimum @ L 70, The colourrendering index of LED light should be more than 70. Luminiarecomprises of driver, PF> 0.95 & surge protection 10KV. Housingmade of pressure die cast aluminium with heat resistant flatglass/Lens type, IP65 protection. Submission LM 79-08/IS16106(2012), IEC60598, IEC61347i/c connection wire, testing etc. tocomplete the job. Please Enable Macros to View BoQ information |