Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-05-2026 | Corrigendum DATE | Date | 04-06-2026 |
| Sl. No. | Item Description |
| 1 | NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects.For 110mm dia Coupler |
| 2 | HSR Item 22.85.3-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia PipesHSR Rate(Rs.) 233.00 Through Rate |
| 3 | HSR Item 21.100.3-Making holes for HCL soil / Waste pipe by core cutting up to 200 mm thick slabs and sealing with Drip seal sealant complete in all respect. 3. 125 mm dia pipeHSR Rate(Rs.) 812.00 Through Rate |
| 4 | NS Item -Providing and fixing 40mm CPVC Union in CPVC pipe including cutting and Jointing the pipe with solution etc. complete in all respects as per direction of engineer incharge |
| 5 | NS Item -Providing and fixing CPVC Ball valve of 25 mm dia including cutting and Jointing the pipe with solution etc. complete in all respects as per direction of engineer incharge. |
| 6 | HSR Item 21.100.4-Making holes for HCL soil / Waste pipe by core cutting up to 200 mm thick slabs and sealing with Drip seal sealant complete in all respect. 4. 150 mm dia pipeHSR Rate(Rs.) 928.00 Through Rate |
| 7 | HSR Item 21.100.2-Making holes for HCL soil / Waste pipe by core cutting up to 200 mm thick slabs and sealing with Drip seal sealant complete in all respect. 2. 100 mm dia pipeHSR Rate(Rs.) 638.00 Through Rate |
| 8 | HSR Item 22.209-Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.HSR Rate(Rs.) 813.00 Through Rate |
| 9 | HSR Item 22.211-Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.HSR Rate(Rs.) 523.00 Through Rate |
| 10 | NS Item -Providing and fixing 50 mm dia CPVC Union in CPVC pipe including cutting and Jointing the pipe with solution etc. complete in all respects as per direction of engineer incharge |
| 11 | NS Item -Providing and fixing CPVC Ball valve of 20 mm dia including cutting and Jointing the pipe with solution etc. complete in all respects as per direction of engineer incharge. |
| 12 | NS Item -Providing and fixing Auto closing concealed Urinal Flush valve with flange Jaquar make (PRS-073) or equivalent approved brand complete in all respects to the satisfection of engineer in charge. |
| 13 | NS Item -Providing and fixing CPVC Ball valve of 40 mm dia including cutting and Jointing the pipe with solution etc. complete in all respects as per direction of engineer incharge. |
| 14 | NS Item -Providing and fixing CPVC tank connector/ tank nipple 25 mm including cutting hole and Jointing the pipe in water tank with solution etc. complete in all respects as per direction of engineer incharge |
| 15 | NS Item -Providing and fixing CPVC tank connector/ tank nipple 32 mm including cutting hole and Jointing the pipe in water tank with solution etc. complete in all respects as per direction of engineer incharge |
| 16 | NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects.For 110mm diaNahani Trap without Jali (110x110) mm |
| 17 | NS Item -Providing and fixing CPVC tank connector/ tank nipple 50 mm including cutting hole and Jointing the pipe in water tank with solution etc. complete in all respects as per direction of engineer incharge |
| 18 | NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects.For 110mm diaSingleTee with door |
| 19 | NS Item -Providing and fixing Angular stop cock with wall Flange Jaquar make (OPP-15053PM) or equivalent approved brand complete in all respects to the satisfection of engineer in charge. |
| 20 | HSR Item 21.100.5-Making holes for HCL soil / Waste pipe by core cutting up to 200 mm thick slabs and sealing with Drip seal sealant complete in all respect. 5. 175 mm dia pipeHSR Rate(Rs.) 1102.00 Through Rate |
| 21 | HSR Item 22.85.5-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 5. 40 mm nominal outer dia PipesHSR Rate(Rs.) 430.00 Through Rate |
| 22 | HSR Item 22.85.4-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia PipesHSR Rate(Rs.) 311.00 Through Rate |
| 23 | NS Item -Providing and fixing Bib cock with wall Flange Jaquar make (OPP-15037PM) or equivalent approved brand complete in all respects to the satisfection of engineer in charge. |
| 24 | HSR Item 22.79.1-Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 1. 100 mmHSR Rate(Rs.) 88.00 Through Rate |
| 25 | HSR Item 22.33-Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.HSR Rate(Rs.) 10809.00 Through Rate |
| 26 | HSR Item 22.15-Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge.HSR Rate(Rs.) 735.00 Through Rate |
| 27 | HSR Item 20.26.2-Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 2. 22.86 cm thick wallHSR Rate(Rs.) 242.00 Through Rate |
| 28 | HSR Item 4.16.1.2-Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia.HSR Rate(Rs.) 64.00 Through Rate |
| 29 | HSR Item 22.14.2.1-Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.2.1. Flexible pipe32 mm diaHSR Rate(Rs.) 57.00 Through Rate |
| 30 | NS Item -Providing and fixing CPVC Ball valve of 32mm dia including cutting and Jointing the pipe with solution etc. complete in all respects as per direction of engineer incharge. |
| 31 | NS Item -Providing and fixing zinc coated chilly/ hanging clamps along with 10 mm dia GI tie rod and 10 mmx75 mm fasteners for all heightsvfor specified dia pipe complete in all respects to the satisfection of engineer in charge. .110 mm dia pipe |
| 32 | NS Item -Providing and fixing zinc coated chilly/ hanging clamps along with 10 mm dia GI tie rod and 10 mmx75 mm fasteners for all heightsvfor specified dia pipe complete in all respects to the satisfection of engineer in charge. .150 mm dia pipe |
| 33 | NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects.For 110 mm dia . P-Trap |
| 34 | NS Item -Providing and fixing Soap Dispenser with glass bottle of Jaquar make (ACN-1135N) or equivalent approved brand complete in all respects to the satisfection of engineer in charge. |
| 35 | NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects.For 110mm diaBend87.5 degree |
| 36 | NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects.For 110mm diaSingleTee |
| 37 | NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects.For 110mm diaVentCowl |
| 38 | NS Item -Providing and fixing 25mm CPVC Union in CPVC pipe including cutting and Jointing the pipe with solution etc. complete in all respects as per direction of engineer incharge . |
| 39 | NS Item -Providing and fixing 20 mm CPVC Union in CPVC pipe including cutting and Jointing the pipe with solution etc. complete |
| 40 | NS Item -Providing and fixing Pillar cock auto closing system Jaquar make (PRS-031) or equivalent approved brand complete in all respects to the satisfection of engineer in charge. |
| 41 | NS Item -Providing and fixing Health Faucet with 1 metre Long Easy Flex Tube in Chrome Finish Including wall hook of Jaquar make (ALD-565) or equivalent approved brand complete in all respects to the satisfection of engineer in charge. |
| 42 | HSR Item 22.222.2.1-Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B160mm o/d SWR UPVC pipe lines laid completeHSR Rate(Rs.) 534.00 Through Rate |
| 43 | HSR Item 22.222.2.2-Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B110mm o/d SWR UPVC pipe lines laid completeHSR Rate(Rs.) 322.00 Through Rate |
| 44 | HSR Item 22.221.9-Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. 9. Size 560mm x 450mm (Under counter oval)HSR Rate(Rs.) 2359.00 Through Rate |
| 45 | HSR Item 22.106.1-Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore HSR Rate(Rs.) 457.00 Through Rate |
| 46 | HSR Item 22.98.5-Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 5. 50 mm nominal boreHSR Rate(Rs.) 730.00 Through Rate |
| 47 | HSR Item 22.181-Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.HSR Rate(Rs.) 7.00 Through Rate |
| 48 | HSR Item 22.109-Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.HSR Rate(Rs.) 49.00 Through Rate |
| 49 | HSR Item 22.86.4-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia PipesHSR Rate(Rs.) 429.00 Through Rate |
| 50 | HSR Item 22.103.3-Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal boreHSR Rate(Rs.) 292.00 Through Rate |
| 51 | HSR Item 22.103.2-Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 2. 20 mm nominal boreHSR Rate(Rs.) 294.00 Through Rate |
| 52 | HSR Item 22.101.2.1-Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length15 mm nominal boreHSR Rate(Rs.) 51.00 Through Rate |
| 53 | HSR Item 22.98.4-Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal boreHSR Rate(Rs.) 567.00 Through Rate |
| 54 | HSR Item 22.86.3-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia PipesHSR Rate(Rs.) 333.00 Through Rate |
| 55 | HSR Item 22.86.2-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia PipesHSR Rate(Rs.) 264.00 Through Rate |
| 56 | HSR Item 22.119.2-Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 2. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.HSR Rate(Rs.) 360.00 Through Rate |
| 57 | HSR Item 22.53.2-Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 2. For 75 mm dia pipe HSR Rate(Rs.) 141.00 Through Rate |
| 58 | HSR Item 22.53.1-Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 1. For 100 mm dia pipe HSR Rate(Rs.) 145.00 Through Rate |
| 59 | HSR Item 22.222.2.3-Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B90mm o/d SWR UPVC pipe lines laid completeHSR Rate(Rs.) 273.00 Through Rate |
| 60 | HSR Item 20.28.1-Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repointing, replastering, replacing bitumen and colour or white washing where required. 1. 75 mm thickness of roof or floorHSR Rate(Rs.) 85.00 Through Rate |
| 61 | HSR Item 20.28.2-Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repointing, replastering, replacing bitumen and colour or white washing where required. 2. 115 mm thickness of roof or floorHSR Rate(Rs.) 103.00 Through Rate |
| 62 | HSR Item 20.28.3-Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repointing, replastering, replacing bitumen and colour or white washing where required. 3. 150 mm thickness of roof or floorHSR Rate(Rs.) 145.00 Through Rate |
| 63 | NS Item -Providing and fixing Urinal (Back Inlet) with fixing accessories having size 385x325x635 mm Jaquar make (URS-WHT-13253N) or equivalent approved brand complete in all respects to the satisfection of engineer in charge. |
| 64 | NS Item -Providing and fixing Toilet paper holder with stainless steel flap of Jaquar make (ACN-1153S) or equivalent approved brand complete in all respects to the satisfection of engineer in charge. |
| 65 | HSR Item 22.11.1-Providing and fixing draining board with C.I. brackets including painting of brackets, cutting and making good the walls wherever required : 1. White glazed fire clay draining board of size 600x450x 25 mmHSR Rate(Rs.) 911.00 Through Rate |
| 66 | HSR Item 22.85.6-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 6. 50 mm nominal outer dia PipesHSR Rate(Rs.) 648.00 Through Rate |
| 67 | NS Item -Providing and fixing CPVC Ball valve of 50 mm dia including cutting and Jointing the pipe with solution etc. complete in all respects as per direction of engineer incharge. |
| 68 | NS Item -Providing and fixing CP jali/grating SS 304, 100 mm with hinges complete in all respects. |
| 69 | NS Item -Providing and fixing CP brass Waste coupling 32 mm of Jaquar make (ALD-705) or equivalent approved brand complete in all respects to the satisfection of engineer in charge. |
| 70 | NS Item -Providing and fixing CP brass Towel Ring round with round flange of Jaquar make (ACN-CHR-1121BN) or equivalent approved brand complete in all respects to the satisfection of engineer in charge. |
| 71 | HSR Item 8.27.2-Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 2. Granite workHSR Rate(Rs.) 230.00 Through Rate |
| 72 | HSR Item 6.60.1-Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints. 1. 200 mm wide.HSR Rate(Rs.) 555.00 Through Rate |
| 73 | HSR Item 6.24.2-Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2. All works above plinth level up to floor IV levelHSR Rate(Rs.) 4511.00 Through Rate |
| 74 | HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand)HSR Rate(Rs.) 113.00 Through Rate |
| 75 | HSR Item 10.106-Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 0 0 0HSR Rate(Rs.) 966.00 Through Rate |
| 76 | HSR Item 10.70.3-Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 3. Size of Tile 800x800 mmHSR Rate(Rs.) 113.00 Through Rate |
| 77 | HSR Item 6.1.6-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)HSR Rate(Rs.) 2442.00 Through Rate |
| 78 | HSR Item 10.72-Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles.HSR Rate(Rs.) 4.00 Through Rate |
| 79 | HSR Item 8.5-Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width up to 150 mm with epoxy resin based adhesive, including cleaning etc. complete.HSR Rate(Rs.) 189.00 Through Rate |
| 80 | HSR Item 7.51-Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor IV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately).HSR Rate(Rs.) 4144.00 Through Rate |
| 81 | HSR Item 6.16-Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). HSR Rate(Rs.) 6113.00 Through Rate |
| 82 | HSR Item 9.18-Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.HSR Rate(Rs.) 147.00 Through Rate |
| 83 | HSR Item 9.11.1-10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10HSR Rate(Rs.) 488.00 Through Rate |
| 84 | HSR Item 13.37.3-Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 3. 80x0.90 mm M.S. laths with 0.90 mm thick top coverHSR Rate(Rs.) 2030.00 Through Rate |
| 85 | HSR Item 12.159.2-Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in- charge . (Cost of aluminium snap beading shall be paid in basic item): 2. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)HSR Rate(Rs.) 922.00 Through Rate |
| 86 | HSR Item 6.30.15-Centering and shuttering including strutting, propping etc. and removal of form for 15. Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the likeHSR Rate(Rs.) 155.00 Through Rate |
| 87 | HSR Item 10.50.1-Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in- Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.HSR Rate(Rs.) 2707.00 Through Rate |
| 88 | HSR Item 6.61.1-Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminium base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical location in load application areas that accommodates multi directional seismic movement without stress to it`s components. System shall consist of metal profiles with a universal aluminium base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre- engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall confirm to ASTM 6063). 1. Floor Joint of 100 mm gapHSR Rate(Rs.) 4472.00 Through Rate |
| 89 | HSR Item 6.63.1-Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer- In-Charge. The joints shall be of extruded aluminium base members with, self aligning and self centering arrangement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminium base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). 1. Roof Joint of 100 mm gapHSR Rate(Rs.) 4124.00 Through Rate |
| 90 | HSR Item 6.62.1-Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminium base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings and complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminium profiles exhibiting minimal exposed aluminium surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 1. Wall Joint of 100 mm gapHSR Rate(Rs.) 3660.00 Through Rate |
| 91 | HSR Item 13.38-Providing and fixing ball bearing for rolling shutters.HSR Rate(Rs.) 322.00 Through Rate |
| 92 | HSR Item 13.39.1-Extra for providing mechanical device chain and crank operation for operating rolling shutters. 1.Exceeding 10.00 sqm and up to 16.80 sqm in the areaHSR Rate(Rs.) 938.00 Through Rate |
| 93 | HSR Item 8.7.1.2-Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 1.2. Wedge expansion typeFastener with threaded dia 10 mmHSR Rate(Rs.) 21.00 Through Rate |
| 94 | HSR Item 11.35-Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.HSR Rate(Rs.) 23.00 Through Rate |
| 95 | HSR Item 2.B0156- B0156. Common burnt clay F.P.S. (non modular)bricks tile class designation 10HSR Rate(Rs.) 4465.00 Rate |
| 96 | HSR Item 5.25-Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.HSR Rate(Rs.) 1562.00 Through Rate |
| 97 | HSR Item 5.14-Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.HSR Rate(Rs.) 35.00 Through Rate |
| 98 | HSR Item 9.46.3-Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm longG.I. wire at every junction, including fixing perimeter channels0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 3. 12.5 mm thick tapered edge gypsum moisture resistant boardHSR Rate(Rs.) 868.00 Through Rate |
| 99 | HSR Item 10.12-Providing and laying of 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.HSR Rate(Rs.) 422.00 Through Rate |
| 100 | HSR Item 10.51-Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc.HSR Rate(Rs.) 2534.00 Through Rate |
| 101 | HSR Item 6.30.16.1-Centering and shuttering including strutting, propping etc. and removal of form for 16.1. Edges of slabs and breaks in floors and wallsUnder 20 cm wideHSR Rate(Rs.) 114.00 Through Rate |
| 102 | HSR Item 10.63.3-Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 3. Size of Tile 800x800 mmHSR Rate(Rs.) 1164.00 Through Rate |
| 103 | HSR Item 5.7.4-Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar HSR Rate(Rs.) 585.00 Through Rate |
| 104 | HSR Item 5.27-Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge.HSR Rate(Rs.) 327.00 Through Rate |
| 105 | HSR Item 11.4.2-10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand)HSR Rate(Rs.) 114.00 Through Rate |
| 106 | HSR Item 11.17-Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in- chargeHSR Rate(Rs.) 234.00 Through Rate |
| 107 | HSR Item 28.14-Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).HSR Rate(Rs.) 375.00 Through Rate |
| 108 | HSR Item 2.B0146- B0146. Brick batsHSR Rate(Rs.) 357.00 Rate |
| 109 | HSR Item 6.30.3-Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platformHSR Rate(Rs.) 208.00 Through Rate |
| 110 | HSR Item 6.27-Extra for R.C.C./ B.M.C/ R.M.C. work above floor IV level for each three floors or part thereof.HSR Rate(Rs.) 244.00 Through Rate |
| 111 | HSR Item 8.32-ALUMINIUM COMPOSITE PANELSDesigning, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis and design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metallic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material and labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item , as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminium Composite Panel Cladding (including width of groove) shall be measured in sqm up to two decimal places.HSR Rate(Rs.) 2475.00 Through Rate |
| 112 | HSR Item 29.5-Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge.For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevant Item).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %,shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.HSR Rate(Rs.) 1425.00 Through Rate |
| 113 | HSR Item 31.14.6-Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in- Charge complete in all respect including drilling and cost of all materials 0 0 0 6. 25mm dia (hole size 30 mm dia & depth upto 300 mm) 0 0HSR Rate(Rs.) 1159.00 Through Rate |
| 114 | HSR Item 34.26-Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including Reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.HSR Rate(Rs.) 542.00 Through Rate |
| 115 | HSR Item 6.15.1-Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone- III) : 3 graded stone aggregate 20 mm nominal size)HSR Rate(Rs.) 5969.00 Through Rate |
| 116 | HSR Item 6.30.5-Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantileversHSR Rate(Rs.) 296.00 Through Rate |
| 117 | HSR Item 9.47.1-Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer- in-charge. 1. GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.HSR Rate(Rs.) 921.00 Through Rate |
| 118 | HSR Item 11.68.3-Applying priming coat: 3. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel worksHSR Rate(Rs.) 19.00 Through Rate |
| 119 | HSR Item 29.4-Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm /sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminium sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.HSR Rate(Rs.) 1323.00 Through Rate |
| 120 | HSR Item 29.6-Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminium sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised/ Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, TandP, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.HSR Rate(Rs.) 1405.00 Through Rate |
| 121 | HSR Item 31.14.2-Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in- Charge complete in all respect including drilling and cost of all materials 0 0 0 2. 10 mm dia (hole size 14 mm.& hole depthup to 100 mm) 0 0HSR Rate(Rs.) 522.00 Through Rate |
| 122 | HSR Item 31.14.3-Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in- Charge complete in all respect including drilling and cost of all materials 0 0 0 3. 12mm dia (hole size 16mm.& hole depth upto 120 mm) 0 0HSR Rate(Rs.) 638.00 Through Rate |
| 123 | HSR Item 31.14.7-Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in- Charge complete in all respect including drilling and cost of all materials 0 0 0 7. 32 mm dia bar hole size 36 mm dia & depth up to 320 mmHSR Rate(Rs.) 1275.00 Through Rate |
| 124 | NS Item -Providing and fixing of 3 mm thick Fiber glass UV stabilized material sheet of DND or equivalenet make fixing with self screw and filling with silicon complete to the satisfaction of engineer incharge. |
| 125 | HSR Item 9.31-Providing and fixing Hi, Rib profiled sheets 0.60mm TT (Total Thickness) (only ± 0.2mm tolerance allowed) Hi Tensile galvalume/Zincalume steel sheet of theapproved make having a hot dip metallic Zinc-Aluminium alloy (AZ-150) coating of minimum (150 gms/sqm) with 550 Mpa yield strength of approved blue colour (RAL-5012) the colour coating shall be as per IS 15965 of SMP or Super Durable Polyester Paint XRW fixed with hex head self-drilling screw sloping roof without curvature as per approved specification, drawing and design of the CorporationHSR Rate(Rs.) 508.00 Through Rate |
| 126 | HSR Item 6.26.1-Extra for providing richer mixes up to plinth and at all floor levels. 1. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)HSR Rate(Rs.) 59.00 Through Rate |
| 127 | HSR Item 6.30.2-Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.HSR Rate(Rs.) 282.00 Through Rate |
| 128 | HSR Item 6.30.1-Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concreteHSR Rate(Rs.) 156.00 Through Rate |
| 129 | HSR Item 6.30.7-Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircasesHSR Rate(Rs.) 290.00 Through Rate |
| 130 | HSR Item 6.32.1-Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 1.Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)HSR Rate(Rs.) 146.00 Through Rate |
| 131 | HSR Item 6.26.3-Extra for providing richer mixes up to plinth and at all floor levels. 3. Providing M-40 grade concrete instead of M-25 grade BMC/ RMC.(Note : Cement content considered in M-40 is @ 360 kg/ cum)HSR Rate(Rs.) 178.00 Through Rate |
| 132 | HSR Item 9.57.3-Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameterHSR Rate(Rs.) 269.00 Through Rate |
| 133 | HSR Item 9.58.1.3-Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.3.Coupler 150 mmHSR Rate(Rs.) 118.00 Through Rate |
| 134 | HSR Item 9.58.5.3-Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3.Bend 87.5°150 mm bendHSR Rate(Rs.) 129.00 Through Rate |
| 135 | HSR Item 9.58.6.3-Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 6.3.Shoe (Plain) 150 mm ShoeHSR Rate(Rs.) 113.00 Through Rate |
| 136 | HSR Item 9.61-Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms.HSR Rate(Rs.) 81.00 Through Rate |
| 137 | HSR Item 10.13.1-Providing and laying cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 1. 18 mm thickHSR Rate(Rs.) 263.00 Through Rate |
| 138 | HSR Item 11.60-Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.HSR Rate(Rs.) 59.00 Through Rate |
| 139 | HSR Item 13.29.1-Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 1. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all completeHSR Rate(Rs.) 79.00 Through Rate |
| 140 | HSR Item 12.89-Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.HSR Rate(Rs.) 701.00 Through Rate |
| 141 | HSR Item 12.132.1-Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where everrequired) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape and size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware`s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing and direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 1. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area up to 0.75 sqm)HSR Rate(Rs.) 4933.00 Through Rate |
| 142 | HSR Item 13.41-Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).HSR Rate(Rs.) 396.00 Through Rate |
| 143 | HSR Item 28.6-`Providing and applying waterproofing treatment to sound, moisture free concrete surface using liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks up to 2 mm. It shall be applied in two coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. The membrane formed shall confirm to following minimum properties:1) Elongation : )400% as per ASTM D 4122) Tensile Strength : 2.5 N/mm2 as per ASTM D 4123) Adhesion in-peel test : )50 N as per ASTM C- 8364) Recovery from 350% elongation : 95% as per ASTM D 4125) Water Vapour Transmission 2.3mm film: 0.6 g/m2/hr6) Initial Hardness Shore A : min 60 as per ASTM D 22407) Root resistant : protection screed requiredSystem includes supply , application and termination of coating all complete as per the manufacturer`s methodology. Clean the RCC slab/screed surface and wall for treatment by removing dust, dirt and layers of concrete over the surface. etc. by mechanical tools and wire brushing. Pressure grouting at construction joints or honeycombs with non shrink cementations grout by mixing shrinkage compensating admixture per bag of cement as per manufacturer`s recommendations. Prepare a side gola of 50X50 mm at the junction using polymer modified mortar. Providing and applying liquid applied single component pitch free polyurethane coating in 2 coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. (Fibre cloth/fleece/reinforcement should not be used in between two coats of PU as it has adverse effect on elongation property and also affects bonding with slab). Termination shall be done 300 mm above FFl by providing a groove cut of 30mm x 30mm and seal it with shrinkage compensated polymer modified mortar.Lay a 150 GSM geotextile layer to protect the coating fromexternal damage on final coating before laying of screed concrete/final finish. It shall be applied as per manufactures specification. Rates are incl of surface preparation, grouting and chemical application only.(Rates for geotextile, protection plaster and final finishes such as screed or Brick bat filling for slope, china mosaic, tiles etc is not included in above item. It will be added as per EIC requirements).`HSR Rate(Rs.) 694.00 Through Rate |
| 144 | HSR Item 29.1-Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.HSR Rate(Rs.) 321.00 Through Rate |
| 145 | HSR Item 29.2-Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide, desiccants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in- Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.29.6)For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, plus 12mm Air gap plus 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.HSR Rate(Rs.) 2269.00 Through Rate |
| 146 | NS Item -Providing and fixing Urinal Glass partition 8 mm thick of Jaquire make model no JSE-CHR-810US450X or equivalent complete in all respects as per direction of engineer incharge. |
| 147 | HSR Item 8.26.2.2-Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shadeArea of slab over 0.50 sqmHSR Rate(Rs.) 2776.00 Through Rate |
| 148 | HSR Item 31.14.4-Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in- Charge complete in all respect including drilling and cost of all materials 0 0 0 4. 16mm dia (hole size 20 mm dia & depth upto 200mm) 0 0HSR Rate(Rs.) 812.00 Through Rate |
| 149 | HSR Item 31.14.5-Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in- Charge complete in all respect including drilling and cost of all materials 0 0 0 5. 20mm dia (hole size 24 mm dia & depth upto 240mm) 0 0HSR Rate(Rs.) 986.00 Through Rate |
| 150 | HSR Item 11.67.1-Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 1. Water thinnable cement primerHSR Rate(Rs.) 22.00 Through Rate |
| 151 | HSR Item 8.28-Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. HSR Rate(Rs.) 393.00 Through Rate |
| 152 | HSR Item 9.10.1-Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 1. With residual type petroleum bitumen of grade VG -10HSR Rate(Rs.) 93.00 Through Rate |
| 153 | HSR Item 9.17.1-Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chaseHSR Rate(Rs.) 112.00 Through Rate |
| 154 | HSR Item 11.5.4-12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand)HSR Rate(Rs.) 104.00 Through Rate |
| 155 | NS Item -Providing and fixing Fire Rated door having double/single leaf 46 mm thick made out of 1.2 mm thick powder coated galvanised steel sheet of approved color having 120 mins fire rating conforming to IS : 3614 (Part 2) or EN1634- 1-1999, tested and certified as per approved laboratory with door frame of GI having single ribbed grooved profile of section 100X55 mm made out of 1.60 mm thick galvanised steel sheet with a factory pre punched groove so as to accommodate fire and smoke seal of size 10X4 mm with zinc coating not less than 120gm/m2. The doors shutter should be duly filled rock wool insulation complete in all respects to the satisfaction of enginner incharge.(The Cost of smoke/fire seal , vision panel, hardware are excluded.) |
| 156 | NS Item -Fire / Smoke seal for double leaf door set : Providing and fixing RP 120 Seal for acoustic, fire and smoke protection, suitable for wooden and steel frames, self adhesive, Finish = Black, Length = 1 x 2000mm, Height- 2 x 2750mm complete as per direction of engineer in charge |
| 157 | NS Item -Providing and fixing single skin 0.8 mm thick MS sheet doors having frame size 100mmx30mm (single skin) duly powder coated in red color and including hardware such as MS pin type hinges Allen lock, 5 mm thick float glass with rouber gasket etc complete in all respect as per direction of engineer incharge. |
| 158 | HSR Item 6.30.6-Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and StrutsHSR Rate(Rs.) 262.00 Through Rate |
| 159 | HSR Item 6.30.4-Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ) HSR Rate(Rs.) 223.00 Through Rate |
| 160 | HSR Item 9.59.3-Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 3. 150 mm HSR Rate(Rs.) 154.00 Through Rate |
| 161 | HSR Item 10.67.3-Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 3. Size of Tile 800x800 mm HSR Rate(Rs.) 1181.00 Through Rate |
| 162 | HSR Item 11.6.1-15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 138.00 Through Rate |
| 163 | HSR Item 13.30.1-Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 1. Hot finished welded type tubesHSR Rate(Rs.) 105.00 Through Rate |
| 164 | HSR Item 11.82.1-Painting the wooden / metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new workHSR Rate(Rs.) 49.00 Through Rate |
| 165 | HSR Item 12.15-Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).HSR Rate(Rs.) 186.00 Through Rate |
| 166 | HSR Item 12.103.2-Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 2. Twin rubber stopperHSR Rate(Rs.) 52.00 Through Rate |
| 167 | HSR Item 12.133.2-Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape and size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame and sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware`s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing and direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 2. Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of2.3 ±. 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door up to 2.50 sqm) HSR Rate(Rs.) 7728.00 Through Rate |
| 168 | HSR Item 12.151-Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side and 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fasteners 14 Nos. ( 5 each on vertical style and 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).HSR Rate(Rs.) 1209.00 Through Rate |
| 169 | HSR Item 12.154-Providing and fixing glazing in fire resistant door shutters, fixed panels and partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, and special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity and radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW and EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqmHSR Rate(Rs.) 34022.00 Through Rate |
| 170 | HSR Item 12.158.2-Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 2. Pre-laminated particle board with decorative lamination on both sidesHSR Rate(Rs.) 789.00 Through Rate |
| 171 | HSR Item 29.3-Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.HSR Rate(Rs.) 2326.00 Through Rate |
| 172 | HSR Item 10.73-Providing and fixing ceramic and Glazed tiles/ vitrified tiles/ of any size of approved make in floors / dados, laid in any pattern as specified over base of 3 mm thick adhesive of reputed brands as per IS specification 15477-2004 using 5 Kg. adhesive per sqm area of tiles and jointed with white cement slurry mixed with pigment to match the shade of tiles excluding cost of tiles.HSR Rate(Rs.) 1247.00 Through Rate |
| 173 | HSR Item 13.29.2-Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksHSR Rate(Rs.) 83.00 Through Rate |
| 174 | HSR Item 28.47-Providing and fixing thermal insulation with Resin bonded rock wool conforming to IS: 8183, density 48 kg/m3, 50 mm thick, wrapped in 200 G virgin Polythene bags placed over existing false ceiling and held in position by criss- crossing Gl wire.HSR Rate(Rs.) 189.00 Through Rate |
| 175 | HSR Item 11.74.2-Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 2. Two coatsHSR Rate(Rs.) 38.00 Through Rate |
| 176 | HSR Item 11.3-Neat cement punning.HSR Rate(Rs.) 29.00 Through Rate |
| 177 | HSR Item 28.22-Providing and Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge.HSR Rate(Rs.) 306.00 Through Rate |
| 178 | HSR Item 11.95.1-Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)HSR Rate(Rs.) 88.00 Through Rate |
| 179 | HSR Item 5.15.1-Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: 1. G.S. SheetHSR Rate(Rs.) 43.00 Through Rate |
| 180 | HSR Item 2.B0966- B0966. Mild steel tubes hot finished welded typeHSR Rate(Rs.) 58.00 Rate |
| 181 | HSR Item 2.B0244- B0244. Rib profiled galvalume/ Zincalume steel sheetHSR Rate(Rs.) 63.00 Rate |
| 182 | HSR Item 2.B0169- B0169. Autoclaved aerated cement (AAC) blocksHSR Rate(Rs.) 2054.00 Rate |
| 183 | NS Item -Providing and fixing Auditorium Chair, SEAT REST ASSEMBLY: The seat rest assembly is 1.5±0.1 cm thk. flat plywood measured as per QA method described in OCP- QLTA-P14-18 and in-situ moulded with polyurethane foam and upholstered with polyester fabric and enclosed by an injection moulded cover. The Seat has an auto-tip up feature making it stay in upright position when not in use enabling clear row passage. The seat profile has a large waterfall edge to help the users get necessary comfort in popliteal region.*SEAT SIZE: 45.0 cm. (W) x 50.5 cm (D) x 13.8 cm (T)Approx. BACKREST ASSEMBLY: The backrestassembly is made up of 1.2±0.1cm thk flat plywood measured as per QA method described in OCP-QLTA P14-18 upholstered with polyester fabric and enclosed by an injection moulded back cover. The back foam is designed with contoured back support for extra comfort. *HIGH BACKSIZE: 48.7 cm. (W) x 76.9 cm (H) x 12.5 cm (T) Approx.HIGH RESILIENCE (HR) POLYURETHANE FOAM:The HRpolyurethane foam for Seat and Back is moulded with Density= 45 plus /- 2kgs/m³. LEG FRAME ASSEMBLY:The leg frame assly is fabricated from M.S. tube 6.0±0.03cm x 4.0±0.03cm x 0.2±0.016cm thk. welded with grouting member. It is black powder coated ( DFT 40-60 microns ) and grouted to the floor using anchors. ARMRESTASSEMBLY: The armrest is made up of black integral skin polyurethane with 65 plus /-10 Shore `A` hardness and reinforced with M.S. insert fixed with leg frame. The armrests are scratch and weather resistant. ARMREST CLADDING:The armrest cladding is made up of 0.9±0.1 cm thk Plywood and upholstered with polyster fabric. The cladding is fixed to Aisle Side panel Only. All in between panels will not have armrest cladding. POWDER COATING: All steelcomponents are Epoxy Polyester Powder Coated ( DFT 40-60 microns ) Complete to the satisfaction of engineer in charge.Make:- Godrej model Glamour Nxt |
| 184 | NS Item -Aluminium Flashing 0.9mm thick: Flashings manufactured from aluminium alloy AA 3004(AlMn1Mg1) as specified in BS EN 1396: 2007 thickness of 0.9 mm and Fluorocarbon PVDF finish of minimum 25 micron thickness on the exposed surface. The material shall be of same color.Girth – max 576 mm complete as per the direction of engineer in charge. |
| 185 | NS Item -STAGE SIDE WINGS: Providing, installation, testing and commissioning of rotatable stage side wings, minimum 1200 mm (4’-0”) wide, height as per stage requirement, fabricated out of 50 mm × 25 mm (minimum 2 mm thick) MS pipe framework, filled with rockwool insulation of approved density ( minimum 48 kg/m3), covered on both sides with 6 mm thick BWP plywood, and overlaid with fire-retardant fabric of approved shade conforming to BS 5867 Part II Type B/C / NFPA 701, stretched and fixed over the BWP plywood surface, including stitching where required, hinges/rotating mechanism, necessary stiffeners, surface preparation, primer and finish paint to MS members, complete as per approved drawings and directions of Engineer-in-Charge.(Fabric make:- Innovative/ Response/Raymond/D-Decor/Vista) |
| 186 | HSR Item 8.24.4-Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface. 4. 12 mm thickHSR Rate(Rs.) 1720.00 Through Rate |
| 187 | HSR Item 11.91-Melamine polishing on wood work (one or more coat).HSR Rate(Rs.) 55.00 Through Rate |
| 188 | NS Item -STAGE WALL PANELLING: Providing and fixing 20 mm thick coloured Acoustic Panels in size 1220 x 610 mm of Natural panel having Premium Square Edge. Panels are made of Pine Wood fibers containing cellulose binded with Magnesite. The panels will be screw fixed @ 200mm on GI metal frame of 50 x 50mm,0.5 mm thick making a grid of 610 x 610mm c/c. The frame is to be made in proper line after leveling. The panels will be backed with 50mm Rockwool of 48 kg/cum inserted inside the grid of 610 x 610mm which will comprise of minimum NRC 0.90 as per IS: 8225/ ISO: 354/ ASTM: 423 – 90 a. The panel meets the stringent fire test required having Class ‘P’ rating for Ignitability test as per BS 476 part 5 and Class ‘1’ rating as per BS 476 part 7 for Surface Spread of Flame test. Class ‘P’ and Class ‘1’ are the highest rating. BS 476-part 6 Fire Propagation index, I = not greater than 4.11. It should meet all technical parameter complete as per direction of Engineer in Charge.MAKE: Armstrong / Anakon/ Ecophon / Ecotone/Credence,Baux. |
| 189 | NS Item -WALL PANELLINGProviding and Fixing of Spandex System fabric confirming to BS 5867 Part II B (Type B/C) /NFPA 701 having fabric weight minimum 400 GSM (Fabric make:-Innovative/ Response/Raymond/D-Decor/Vista or equivalent) on G.I studs 2400mm X 50mm web and flanges of 15 and 50 mm fully knurled giving it high strength, hot dipped galvanized steel With 120 GSM zinc coating specially designed for Acoustic vibration management and long life with a backing 50mm thick Rock wool @48kg/cum density insulation intact with chicken mess wires. 600x1200x15mm Magnesite pine wool tile with NRC 0.9-1 to be mechanically fastened on the G.I Studs.Then 12 mm clip rail system are screw fixed on to the 12 mm MDF waterproof and Acoustics panel’s .Then the Spandex is stretched over the clip rail system. The installed system should provide NRC OF 1.00. Spandex colour as per Architect choice-Ref attached specifications for more details.Makes -Armstrong / Anakon/ Ecophon/Ecotone/Credence/Baux. |
| 190 | HSR Item 10.54.1-Providing and fixing 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : 1. Second class teak woodHSR Rate(Rs.) 3423.00 Through Rate |
| 191 | NS Item -Providing and fixing machine tufted loop pile carpet flooring of approved make, shade and design, having 100% nylon yarn composition, suitable for heavy-duty commercial use, with pile height 7–8 mm and total thickness 10 mm, pile weight not less than 850 g/m² and total weight not less than 1670 g/m², having woven polypropylene primary backing and secondary backing of action back/felt back with Ecoflex NXT or equivalent, in roll form of approx. 30 m length × 4.0 m width, conforming to flammability requirements as per 16 CFR 1631 and smoke density less than 450 as per ASTM E662, with light fastness of minimum grade 4, thermal resistance of approx. 0.09 m² K/W, and impact sound insulation (?LW) of 28 dB, having antistatic and anti-skid properties, the carpet to be laid over prepared cementitious flooring using approved epoxy-based adhesive (Gorilla or equivalent),Spinta color series or equivalent including surface preparation, cutting, jointing, edge finishing, and proper alignment, complete in all respects as per manufacturer’s specifications and direction of Engineer-in-Charge. Makes:- Armstrong/Forbo/Divine |
| 192 | NS Item -Providing and fixing of skylight glazing system at any height with 13.52 mm thick toughened laminated glass (6mm Colored T plus 1.52 PVDF layer plus 6mm Clear Toughned glass), glass shall be rest on existing powder coated extruded aluminium member with aluminium cover plate, weather silicon sealent and other fixing hardware etc. Glazing shall be fixed on existing MS framework with all necessary accessories incl. , screws , EPDM glazing gasket etc. to ensure proper sealing and waterproofing complete to the satisfaction of engineer incharge. Glass panels sizes shall be appx. 1000x1000mm max. The rate includes the cost of wastage of glass, transportaion, scaffolding etc. (MS work and aluminum work shall be Paid seperatly.)Note:- Scaffolding and safety measures etc to be included in the contractor’s scope no extra claim on will provided to agency |
| 193 | NS Item -DOUBLE LEAF DOUBLE ACTION GLASS DOORS (2100X 1800 X 12MM GLASS )- clip in profile system 45mm (EV1 silver finish ) Supply and Fixing of 12mm toughened glass door with DORMAKABA /equivalent Alterra lite System- 45 frames all around the door. Door frame ALTERRA LITE 45- Double leaf double Action Door_Complete Assembly 3M Stock Length End profiles of size 45X50mm with The profiles shall be suitable for Glass thickness of 12 mm.The Profile shall be matt natural anodized, the door hardware and profile manufacturer to supply shoud be from single supplier and supply all the necessary clips, seals and fixing accessories for the system with patch fitting with stainless steel cover as ( PT 24 top pivot patch ) , ( PT 10 bottom patch) ,( PT 20 Top patch),(US-10- corner lock with EPC ), Dormakaba Antimicrobial pull Handle TGDI-H type 600 back to back with 500mm CTC, adjustable fixing for glass ,Length =600mm, 32mm dia, - SS304 Finish: mill , dormakaba floor spring BTS 75V with std. spindle and cover plate. As per EN 1154.(500,000 cyle tested) , Finish: Satin stainless steel.Dorma floor stop half dome with 45mm dia with fixing accessories, in satin Chrome .Final certifications of products should be submitted be from the product manufacturer for the originality of the product . The above work complete in all respect as per approved drawings and to the satisfaction of Architect /Engineer-in-Charge. SatinFinish. All Profiles to be with 2 mm Gauge thickness Excluding 20 Micron of Anodizing. Approved Manufacturer: Slim line frame solution : DORMAKABA /equivalent Glass : Saint Gobain/Asahi |
| 194 | NS Item -ALTERRA LITE SINGLE GLAZED TOUGHENED GLASS PARTITIONS - WITH CLIPIN PROFILE SYSTEM-45 FRAME :-Supply and Fixing of slim line Glass partition system with 12mm Toughened Glass using DORMAKABA Alterra lite with 45mm Frames natural anodised finish or Equalent frames to a height of maximum 3mtr ( 3000mm ) or as per archietcs drawing.The Fixed glass to be fixed using Alterra lite base profiles 45x25mm profiles at Top and Bottom and side profiles of 45x25mm at sides. The profile size to be 45x25mm to be fixed on to the floor/wall/ ceiling as per the architect design. H -Junction profiles to be used at all Glass to Glass vertical joints along with 90 Deg L Junction Profiles and T Junction profiles necessary as per design.In case of Glass overall panel 45x50mm Overpanel Profile to be used.In case of Open glass edges end Profiles size 45 x50mm to be used. The DORMAKABA profiles shall be suitable for Glass thickness of 12mm.The Profile shall be natural anodized finish ,the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. Final certifications of products should be submitted be from the product manufacturer for the originality of the product.The above work shall be complete in all respect as perapproved drawings and to the satisfaction of Engineer-in- Charge. All Profiles to be with 2 mm Gauge thickness excluding 20 Micron of Anodizing. Approved Manufacturer: Profiles/Frames: DORMAKABA/Equivalent Glass: Saint Gobain/Asahi |
| 195 | NS Item -Providing and fixing of Fresh Color Restroom/Toilets Cubicles Systems :- MODLE TYPE - TITAN SS SERIES Thickness of Compact Laminate : 12 mm Color of HPL Boards: Single Color Size of Cubicle :- As per drawing /1000 mm x 1550 mm with height 2100mm Door Size : 1750mm (H) X 600mm (W) Overall Height Of Cubicle : 2100mm (Including bottom Gap of 150mm) Accessories: Standard – Stainless Steel - 304 Grade accessories a) SS “U” Channel□ b) SS “F” channel - c) SS Top Rail SS d) SS Coat Hook e) SS Privacy Thumb turn c/w Occupancy Indicator f) SS Door Knob g) SS Hinges with Cover h) SS Adjustable Foot - i) Rubber Lining for Groove j) S.S.Screws 304 G and P.V.C Wall Plugs complete in all respects and to the entire satisfaction of engineer incharge . (Merino / equivalent) |
| 196 | NS Item -Providing and fixing SS 304 Ball Bearing hinges 4`x3` for fire rated door complete as per direction of engineer in charge. |
| 197 | NS Item -Door Closer : Providing and fixing fire rated rack and pinion door closer of make Dormakaba TS 71 EN size 3/4 , with std. arm and with two independent closing valves and latching speed adjustable by arm. Full plastic cover. Silver finish. As per EN 1154. The door closer shall have a 10 year mechanical guarranty / warranty from the manufacturer and the same shall be submitted to the Engineer -in-charge. |
| 198 | NS Item -Handle : Providing and fixing DORMAKABA pull Handle TGDI-D 300 back to back with adjustable fixing for glass, wood and metal doors in satin stainless steel. The pull handles should have supporting washer with raised bevelling on the outer surface. Length =300mm, 22mm dia, -SS304. The Door Handle shall have atleast 1 year mechanical guarranty / warranty from the manufacturer and the same shall be submitted to the Engineer -in-charge. |
| 199 | NS Item -Door Stop half dome : Providing and fixing Dormakaba floor stop half dome with 45mm dia with fixing accessories, in satin Chrome. |
| 200 | NS Item -Providing and fixing Dormakaba PHB 3000 series or equivalent fire-rated panic exit device suitable for double leaf doors, with 3-point vertical rod locking (top, bottom and latch), complete with PHT external trim (lever handle) and Euro profile cylinder, tested and certified to EN 1125, including all accessories such as strikes, rod guides, and fixing hardware, complete as per manufacturer’s specifications and direction of Engineer-in-Charge. |
| 201 | NS Item -Providing and Fixing Dormakaba or equivalent Stainless Steel Grade 304 Flush Bolt, suitable for fire-rated double leaf doors, having body length 172 mm with 300 mm long rod, with all necessary accessories such as strikes, guides, and fixing hardware etc. complete as per direction of engineer in charge. |
| 202 | NS Item -Providing and fixing Dormakaba or equivalent fire- rated dead lock, having 55 mm backset, with 20 mm wide square forend, suitable for fire-rated door assemblies. The lock body and face plate shall be made of Stainless Steel Grade 304, complete with matching SS 304 strike plate, 70 mm long key cylinder (EPC – Euro Profile Cylinder), and all necessary fixing screws and accessories complete in all respects as per manufacturer’s specifications and direction of Engineer-in-Charge. |
| 203 | HSR Item 2.B0963- B0963. Top cover of Rolling shutters 0.90 mm thickHSR Rate(Rs.) 402.00 Rate |
| 204 | HSR Item 9.46.4-Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm longG.I. wire at every junction, including fixing perimeter channels0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 4. Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturer s specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60 HSR Rate(Rs.) 1032.00 Through Rate |
| 205 | HSR Item 32.47.2-Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance = 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 and7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre and 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer- in-charge. 2. With 20 mm thick bevelled tegular mineral fibre false ceiling tile (NRC 0.7)HSR Rate(Rs.) 1465.00 Through Rate |
| 206 | NS Item -Providing and fixing wood-based slatted acoustic panels with linear perforations, comprising FR grade High Density Fibreboard (HDF) density not less than 800 kg/m³, finished with decorative melamine laminate on exposed surfaces........The panels shall be of size 2440 mm (H) × 128 mm (W) × 15 mm (T), having 2 mm wide grooves at 15 mm pitch, with tongue and groove edge profiling for seamless and continuous appearance........The rear face of the panels shall be acoustically perforated with 10 mm diameter circular holes, backed with 0.2 mm thick non-woven acoustic fleece, achieving an overall Noise Reduction Coefficient (NRC) of 0.90.......The panels shall be fixed over a G.I. framework system, comprising: Vertical studs made out of GI sections of size 50 mm (web) × 35 mm (flange) × minimum 0.5 mm thick, placed at maximum 600 mm c/c and Floor and ceiling channels of size 50 mm × 32 mm × minimum 0.5 mm thick. The cavity formedbetween the framework shall be filled with mineral wool (rock wool) insulation of 25 mm thickness and 48 kg/m³ density, to achieve the desired acoustic performance.The panelling should be properly done in proper alignment, level and to ensure complete coverage of beams, columns, and recessed/hollow areas. All work shall be executed as perapproved drawings and instructions of the Engineer-in-Charge complete in all respects for all heights and levels. Makes: Armstrong / Ecophon/Ecotone/Credence/Baux/Envirotech |
| 207 | HSR Item 10.3-Supplying and providing of Tangri River Sand under floors Including watering and compaction in 25cm layers, dressing etc. complete In all respects (As per item 10.2)HSR Rate(Rs.) 494.00 Through Rate |
| 208 | NS Item -REAR CURTAIN: Supply, installation, testing and commissioning of Vertical Stage Curtain , made out of inherently fire-retardant polyester fabric / glazed cotton velvet cloth/approved by engineer incharge, confirming to BS 5867 Part II B (Type B/C) /NFPA 701 having febric weight minimum 650 GSM (Fabric make:-Innovative/ Response/Raymond/D- Decor/Recron FR/ Indorama/ventures/Trevira CS), size appox 17 mtr/as per stage opening and approved drawings, with vertical upward and downward motorized operation,Modren theater Draphery/as approved by engineer incharge complete in all respects.The work shall include providing and fixing heavy-duty curtain fabric, stitched with proper pleats (fullness 1.5 to 2 times), reinforced edges, eyelets, and necessary accessories, mounted on MS/GI curtain rails, brackets, runners, master runners, cup links, pulleys, and complete suspension system using 3 mm dia steel wire rope, mini drums, counterweights, and limit switches.The system shall be operated by minimum 2 HP electric motor with suitable gear box, complete with two numbers air-break contactors (LandT / Siemens make), push button control station for UP / DOWN / STOP operation, wiring, safety interlocks, and electrical accessories, complete.Motor mounting shall be done on a C-channel platform fixed to the side wall, including all supports, anchors, nuts, bolts, and alignment. The curtain cloth shall be certified fire retardant, with test certificates to be submitted complete to the satisfaction of Engineer-in-Charge.Warranty:Minimum 5 years warranty on the complete motorized curtain system from the date of installation. |
| 209 | NS Item -MAIN CURTAIN/: Supply, installation, testing and commissioning of Vertical Stage Curtain , made out of Inherently fire-retardant polyester fabric / glazed cotton velvet cloth / approved by engineer incharge, confirming to BS 5867 Part II B (Type B/C) /NFPA 701 having febric weight minimum 650 GSM (Fabric make:-Innovative/ Response/Raymond/D- Decor/Recron FR/ Indorama/ventures/Trevira CS ), size appox 21 mtr/as per stage opening and approved drawings, with vertical upward and downward motorized operation,Modren theater Draphery/as approved by engineer incharge complete in all respects.The work shall include providing and fixing heavy-duty curtain fabric, stitched with proper pleats (fullness 1.5 to 2 times), reinforced edges, eyelets, and necessary accessories, mounted on MS/GI curtain rails, brackets, runners, master runners, cup links, pulleys, and complete suspension system using 3 mm dia steel wire rope, mini drums, counterweights, and limit switches.The system shall be operated by minimum 2 HP electric motor with suitable gear box, complete with two numbers air-break contactors (LandT / Siemens make), push button control station for UP / DOWN / STOP operation, wiring, safety interlocks, and electrical accessories, complete.Motor mounting shall be done on a C-channel platform fixed to the side wall, including all supports, anchors, nuts, bolts, and alignment. The curtain cloth shall be certified fire retardant, with test certificates to be submitted complete to the satisfaction of Engineer-in-Charge.Warranty:Minimum 5 years warranty on the complete motorized curtain system from the date of installation. |
| 210 | HSR Item 7.22.2-Brick work with common burnt clay non- modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in: 2. Cement mortar 1:6 (1 cement : 6 coarse sand)HSR Rate(Rs.) 4488.00 Through Rate |
| 211 | NS Item -Design - Designing, Providing and fixing KingZip KINGSPAN SF400 “SELF SUPPORTED”CONCEALED FIX ALLUMINIUM STANDING SEAMROOFING SYSTEM OFKingspan KingZip or equivalent make at any height, comprising of the following layers. i) Top Layer –KingZip Kingspan SF 400 or equivalent profiled sheeting manufactured from Aluminium alloy AlMnlMgl as specified in BSEN 1396:2007 – Quality AA 3004, thickness of 0.9 mm with PVDF coating minimum 25 micron thick on the exposed surface and finish as approved by Engineer-in-Charge.Ultimate tensile strength: minimum 200 N/mm2, 0.2% Proof Stress: min 185 N/mm2, Modulus of elasticity: 70,000 N/mm2. Sheets are to be laid to meet the requirements of the building geometry and fixed on Aluminium halters. Aluminium halters to be fixed purlins with SS 304 screws. The profiled roof panel should have 24nos. of Micro ribs of height 1.5mm in between 3Nos of Mini ribs for extra strength Accessories, Fasteners.Sheets are to be laid to meet the requirements of the building geometry and fixed on Aluminium Halters. The installation team shall be fully trained and approved by the supplier.. ) Halter – Aluminium Halters of grade 6082(T6) of suitable height with thermal barrier pads 6mm to be fixed to the sub purlins with SS 304 screws only. iii) Insulation -shall be 100 mm thick (orlaid in two layers of 50mm with vapour barrier ) Rockwool with minimum density 60 kg/m3 as approved by Engineer-In- Charge. iv) vapour control barrier – Polyethylenefilm or Aluminium foil of 0.20mm thick, heavy-duty type. v) Liner - sheet manufactured from 0.47mmbase metal thickness (BMT) .The panel shall be of 980- 1015mm effective cover width, 28- 30mm rib height, 190- 203 mm pitch, manufactured out of Hi tensile pre-painted Zincalume/Galvalume steel-AZ150 (min. 150 gms/sq.mt total on both sides) having minimum yield strength of 550 MPa with Super durable Polyester /SMP or approved equivalent quality paint coat as per AS/NZS 728 Class 3. The entire Double skin system is installed over the structure purlin. The contractor shall prepare the shop drawings based on the drawings supplied by the Engineer-in-charge for approval.Make:- Kingspan Jindal,Tata steel colors, Aluform. |
| 212 | NS Item -STAGE FRILLS: Providing, supplying, stitching, fixing, testing and commissioning of stage frills of approved shade and texture, made of fire-retardant polyester fabric / glazed cotton velvet cloth / approved by engineer incharge, confirming to BS 5867 Part II B (Type B/C) /NFPA 701 having febric weight minimum 650 GSM ,(Fabric make:- Innovative/ Response/Raymond/D-Decor/Recron FR/ Indorama/ventures/Trevira CS) complete , fixed on 28 mm dia GI pipe (Heavy duty) with adjustable supports, installed above the stage as per approved stage positioning plan, including all fittings, accessories and labour.The stage frill shall have a minimum finished depth of 300 mm (or as specified in drawings) with adequate pleating fullness of 1.5 to 2 times the stage width, and shall extend across the entire stage width as per approved layout complete as directed by Engineer-in-Charge. |
| 213 | NS Item -Tower Bolt : Providing and fixing DORMA Surface Mounted Tower Bolt 6” high (SS 304 grade) complete in all respects. |
| 214 | HSR Item 6.34.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps.Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more.HSR Rate(Rs.) 68.00 Through Rate |
| 215 | HSR Item 10.107-Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in- Charge. 0 0 0HSR Rate(Rs.) 1605.00 Through Rate |
| 216 | NS Item -Providing and fixing acrylic Braille indicators for handrails of the approved design and make having Braille dots raised 0.5mm above base plate, to be installed at the specified locations as per the directions of the engineer in charge complete as per design/specificaitons and guidelines as per the entire satisfaction of the the Engineer-in-charge |
| 217 | NS Item -Providing and fiixing acrylic multilingual Braille (raised dots) DIRECTIONAL SIGNBOARDS of size 6` x 9` designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devanagari non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a non-glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL complete as per design/specificaitons and guidelines as per the entire satisfaction of the the Engineer-in-charge |
| 218 | NS Item -Providing and fixing acrylic multilingual Braille (raised dots) signboards (DOOR SIGNBOARDS) of size 6`x 9` for room titles, designed as per the drawings issued and having 4mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devanagari non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL complete as per design/specificaitons and guidelines as per the entire satisfaction of the the Engineer-in-charge |
| 219 | NS Item -Providing and fixing of high intensity reflective conspicuity tape 25 to 50mm width, on edges of treads in staircase including, cutting, pasting etc. of make 3M or equivalent brand complete in all respect to the entire satisfaction of Engineer-in-charge |
| 220 | NS Item -Providing and Fixing of Pictorial layout plan of size 900mmx600mm as approved design, made of 3mm thick acrylic non glare base plate and non glare cut out symbols with grade One Braille on which individual facility points, like inquiry, reception, restrooms, medical room/ first aid, cafeteria or breakout area, lounge, meeting room, conference room etc. present the respective floors with pictograph wherever needed all in tactile raised by minimum of 1to2 mm in various colours to make it legible for seniors, partial vision impaired etc. All the facility names should be in Braille, along with English or Hindi.The entire block of tactile signs should be mounted on wall or on a slant/ inclined frame for easy reading. The map to be installed at specified locations and installed at a height of 800mm from ground level complete in all respect as per Harmonized guideline and satisfaction of Engineer-in-charges. |
| 221 | NS Item -Providing and fixing of acrylic, non-glare, tactile audio pictorial building layout as per the approved size, design and make, having 6mm thick acrylic non glare base plate of the approved color and non-glare acrylic cut out symbols and upper case Sans Serif letters of 12mm height, raised 3mm above base plate and Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. The map to be installed at the specified location as per accessibility standards, shall be oriented to the position of the viewer and to be installed at a height of 800 mm from the finished ground/ floor level and using the necessary hardware specified by the manufacturer and to be installed up to the height of 800 mm from the finished ground/ floor level and using the necessary hardware specified by the manufacturer and to be installed complete as per design/specificaitons and guidelines as per the entire satisfaction of the the Engineer-in- charge |
| 222 | NS Item -Providing and fixing `U` shaped `Flip Bar` 650mm long and 30mm-40mm thick diameter of 18-gauge with hinge made up of `stainless steel 304 grade` of International Standard in the toilets to make them `Unisex Toilet` for visually impaired visitors as per design / specification and guidelines complete in all respect to the entire satisfaction of Engineer-in-charge |
| 223 | NS Item -Providing and fixing `L` shaped `Grab Bar` 600mm long and 30mm-40mm thick diameter of 18-gauge made up of`stainless steel 304 grade` of International Standard in the toilets to make them `Unisex Toilet` for visually impaired visitors as per design / specification and guidelines complete in all respect to the entire satisfaction of Engineer-in-charge |
| 224 | NS Item -Providing and fixing of SS 304 grade, non-glare multilingual Braille (raised dots) ENTRANCE SIGNAGE (size 1 ft x 1 ft) as per the approved design and make, indicating the name of the building having 1.2mm thick SS 304 grade non glare blue colored base plate with the `Universal Accessibility Symbol` and Upper case Sans Serif words of height 15mm engraved on it along with the equivalent word/ s written in Hindi using Devanagari script of height 15mm in white color Grade 2/ Grade 1 Braille to be etched/ engraved and be raised 0.5mm above base plate. The signage to be installed at the specified location on the compound wall near the site entrance gate installed at a height of 1200 mm from the finished ground/ floor level, using the necessary hardware specified by the manufacturer and to be installed complete as per design/specificaitons and guidelines as per the entire satisfaction of the the Engineer-in-charge |
| 225 | NS Item -Providing and fixing of SS 304 Grade, non-glare Signage board (2 ft. x 2 ft.- 1 no.) for the accessible parking, as per the approved design and make, having 1.2mm thick SS non glare base plate and Grade 2/Grade 1 Braille (raised dots)to be etched/engraved and be raised 0.5mm above base plate and Upper Case San Serif words and Universal Accessibility Symbol to be etched/engraved and signage to be installed at a height of 2100mm from the ground level using a post of MS hollow square section (50mm x 50mm x mini 2 mm thick) as per the installation procedure specified by the manufacturer and as per accessibility standards complete as per design/specificaitons and guidelines as per the entire satisfaction of the the Engineer-in-charge |
| 226 | NS Item -Providing and fixing retro-reflective information SIGNAGES to provide clear information about the the building/institute in English/Hindi languages clearly visible, readable, understandable , with Type XI Retro-Reflective Sheeting as per ASTM D4956 standard (3M or equivalent) and appropriate level, made of 3mm thick ACP sheet with border of 50mm dia round pipe and supported with 200mm dia round pipes of 10-gauge fixed in the gate pillars properly designed M-20 grade cement concrete complete in all respect as per design/specifications and guidelines as per the entire satisfaction of the the Engineer-in-charge (Size 6 Mtr. X 1.22 Mtr.) |
| 227 | NS Item -Providing and fixing multilingual and tactile Emergency Evacuation Map for each floor made on minimum 3 mm thick ACP base panel. The map shall include the text “YOU ARE HERE” in red letters of 15 mm height on white background indicating the emergency exits, loaction of fire extinguishers etc and a solid header with the text “EVACUATION PLAN” in contrasting uppercase letters not less than 3/4 inch in height. The sign shall be of size 600 mm× 600 mm and fixed at a height of 1200 mm from FFL, oriented as per viewer direction. Complete in all respects as per approved design and safety guidelines to the satisfaction of the Engineer-in-Charge. |
| 228 | NS Item -Providing and fixing 50 mm wide colour-contrast self-adhesive PVC/aluminium oxide abrasive tape ‘EDGESTRIPS’ on the treads of staircases to assist visually impaired persons in identifying stair edges even under low-light conditions, complete in all respects and to the entire satisfaction of the Engineer-in-Charge. |
| 229 | HSR Item 32.70.3-Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-(a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.(b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus/- 2.5 Hz, output voltage suitable to generate AC(c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency(d) Data Monitoring System complete with accessories.(e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.(f) Lightning and surge voltage protection.(g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 3. Above 100 kWp and up to 500 KwpHSR Rate(Rs.) 40003.00 Through Rate |
| 230 | HSR Item 23.4.1.3-COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3.Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group CHSR Rate(Rs.) 710.00 Through Rate |
| 231 | HSR Item 24.2.7.1-LT CABLE 7.1. Supply and erection of suitable compression type brass cable glands for underground Cable :- Up to 6 Sq mm cable 2 to 4 CoreHSR Rate(Rs.) 32.00 Through Rate |
| 232 | HSR Item 24.2.6.6-LT CABLE 6.6. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 16 sqmmHSR Rate(Rs.) 13.00 Through Rate |
| 233 | HSR Item 24.2.6.5-LT CABLE 6.5. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 10 sqmmHSR Rate(Rs.) 9.00 Through Rate |
| 234 | HSR Item 24.2.7.4-LT CABLE 7.4. Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core HSR Rate(Rs.) 104.00 Through Rate |
| 235 | HSR Item 24.2.8.5-LT CABLE 8.5. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 25 sqmm HSR Rate(Rs.) 10.00 Through Rate |
| 236 | HSR Item 24.5.2.4-MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 90/75 mm outer dia/inner diaHSR Rate(Rs.) 161.00 Through Rate |
| 237 | HSR Item 20.71.1-Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm)HSR Rate(Rs.) 2054.00 Through Rate |
| 238 | HSR Item 24.14.38-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 38. 35 Sq mm 3.5 core (Arm.)HSR Rate(Rs.) 259.00 Through Rate |
| 239 | HSR Item 24.14.100-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 100. 400 Sq mm 3.5 core (Arm.)HSR Rate(Rs.) 1988.00 Through Rate |
| 240 | HSR Item 24.14.94-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 94. 300 Sq mm 3.5 core (Arm.)HSR Rate(Rs.) 1592.00 Through Rate |
| 241 | HSR Item 23.24.4.4-MS STAND, BUS BAR CHAMBER ANDPANELS 4.4. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 8 way 400 amp.HSR Rate(Rs.) 56621.00 Through Rate |
| 242 | HSR Item 24.14.24-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OFTHE WORK 24. 16 Sq mm 4 core (Arm.)HSR Rate(Rs.) 189.00 Through Rate |
| 243 | HSR Item 24.14.88-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 88. 240 Sq mm 3.5 core (Arm.)HSR Rate(Rs.) 1303.00 Through Rate |
| 244 | HSR Item 24.14.54-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 54. 70 Sq mm 3.5 core (Arm.)HSR Rate(Rs.) 463.00 Through Rate |
| 245 | HSR Item 24.16.4-HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 4. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 95 Sq mm 3 coreHSR Rate(Rs.) 991.00 Through Rate |
| 246 | HSR Item 23.24.4.2-MS STAND, BUS BAR CHAMBER ANDPANELS 4.2. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 8 way 250 amp.HSR Rate(Rs.) 52129.00 Through Rate |
| 247 | HSR Item 24.7.7-RCC FOUNDATIONS FOR DG SET 7. 500 KVA DG SetHSR Rate(Rs.) 97639.00 Through Rate |
| 248 | HSR Item 23.22.4.5-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing)HSR Rate(Rs.) 2707.00 Through Rate |
| 249 | HSR Item 24.2.7.2-LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core HSR Rate(Rs.) 45.00 Through Rate |
| 250 | HSR Item 23.22.4.7-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing)HSR Rate(Rs.) 3958.00 Through Rate |
| 251 | HSR Item 23.8.11.3-FITTING AND ACCESSORIES 11.3.Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch HSR Rate(Rs.) 82.00 Through Rate |
| 252 | HSR Item 24.2.8.10-LT CABLE 8.10. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 120 sqmmHSR Rate(Rs.) 32.00 Through Rate |
| 253 | HSR Item 24.2.8.11-LT CABLE 8.11. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 150 sqmm HSR Rate(Rs.) 40.00 Through Rate |
| 254 | HSR Item 24.2.8.7-LT CABLE 8.7. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm HSR Rate(Rs.) 15.00 Through Rate |
| 255 | HSR Item 24.1.1-EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.HSR Rate(Rs.) 2721.00 Through Rate |
| 256 | HSR Item 24.1.11-EARTHING AND LIGHTENINGARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required.HSR Rate(Rs.) 189.00 Through Rate |
| 257 | HSR Item 23.8.10.3-FITTING AND ACCESSORIES 10.3.Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 4 Modules HSR Rate(Rs.) 140.00 Through Rate |
| 258 | HSR Item 23.8.11.7-FITTING AND ACCESSORIES 11.7.Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 wattHSR Rate(Rs.) 257.00 Through Rate |
| 259 | HSR Item 23.8.11.10-FITTING AND ACCESSORIES 11.10.Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plateHSR Rate(Rs.) 18.00 Through Rate |
| 260 | HSR Item 23.8.11.9-FITTING AND ACCESSORIES 11.9.Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. T.V. Socket outlet modular typeHSR Rate(Rs.) 75.00 Through Rate |
| 261 | HSR Item 23.7.6.3-PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.3. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 32 mm dia.HSR Rate(Rs.) 45.00 Through Rate |
| 262 | HSR Item 23.22.4.2-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing)HSR Rate(Rs.) 1406.00 Through Rate |
| 263 | HSR Item 23.8.10.1-FITTING AND ACCESSORIES 10.1.Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and dataHSR Rate(Rs.) 93.00 Through Rate |
| 264 | HSR Item 24.2.6.4-LT CABLE 6.4. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 6 sqmmHSR Rate(Rs.) 8.00 Through Rate |
| 265 | HSR Item 23.8.11.4-FITTING AND ACCESSORIES 11.4.Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp SocketHSR Rate(Rs.) 82.00 Through Rate |
| 266 | HSR Item 24.5.2.5-MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner diaHSR Rate(Rs.) 241.00 Through Rate |
| 267 | HSR Item 24.2.8.12-LT CABLE 8.12. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 185 sqmmHSR Rate(Rs.) 49.00 Through Rate |
| 268 | HSR Item 24.2.7.3-LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 CoreHSR Rate(Rs.) 77.00 Through Rate |
| 269 | HSR Item 24.2.7.5-LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 CoreHSR Rate(Rs.) 133.00 Through Rate |
| 270 | HSR Item 24.2.7.6-LT CABLE 7.6. Supply and erection of suitable compression type brass cable glands for underground Cable :- 240 sqmm to Cable 3 to 32 CoreHSR Rate(Rs.) 165.00 Through Rate |
| 271 | HSR Item 24.2.8.2-LT CABLE 8.2. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 4 sqmm to 6 sqmmHSR Rate(Rs.) 4.00 Through Rate |
| 272 | HSR Item 24.2.8.3-LT CABLE 8.3. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 10 sqmmHSR Rate(Rs.) 6.00 Through Rate |
| 273 | HSR Item 24.2.8.6-LT CABLE 8.6. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 35 sqmmHSR Rate(Rs.) 11.00 Through Rate |
| 274 | HSR Item 24.2.8.9-LT CABLE 8.9. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 95 sqmmHSR Rate(Rs.) 23.00 Through Rate |
| 275 | HSR Item 23.23.6..2-MISCELLANEOUS 6..2. Supply anderection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 200 X 50 X 2 mmHSR Rate(Rs.) 351.00 Through Rate |
| 276 | HSR Item 23.23.8.2-MISCELLANEOUS 8.2. Supply andlaying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 4 pair telephone wireHSR Rate(Rs.) 14.00 Through Rate |
| 277 | HSR Item 24.5.2.3-MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner diaHSR Rate(Rs.) 124.00 Through Rate |
| 278 | HSR Item 23.23.9-MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as requiredHSR Rate(Rs.) 31.00 Through Rate |
| 279 | HSR Item 24.14.76-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 76. 150 Sq mm 3.5 core (Arm.)HSR Rate(Rs.) 809.00 Through Rate |
| 280 | HSR Item 24.14.18-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 18. 10 Sq mm 4 core (Arm.)HSR Rate(Rs.) 151.00 Through Rate |
| 281 | HSR Item 23.4.2.3-COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 2.3.Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group CHSR Rate(Rs.) 922.00 Through Rate |
| 282 | HSR Item 23.23.6.1-MISCELLANEOUS 6.1. Supply anderection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 100 X 50 X 2 mmHSR Rate(Rs.) 231.00 Through Rate |
| 283 | HSR Item 23.3.6.1-COPPER WIRING IN PVC CONDUIT(SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm)HSR Rate(Rs.) 88.00 Through Rate |
| 284 | HSR Item 23.4.3.3-COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 3.3.Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group CHSR Rate(Rs.) 326.00 Through Rate |
| 285 | HSR Item 23.4.5.3-COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.3.Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group CHSR Rate(Rs.) 1292.00 Through Rate |
| 286 | HSR Item 23.22.5.1-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single PoleHSR Rate(Rs.) 145.00 Through Rate |
| 287 | HSR Item 24.1.2-EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.HSR Rate(Rs.) 652.00 Through Rate |
| 288 | HSR Item 24.1.3-EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.HSR Rate(Rs.) 3368.00 Through Rate |
| 289 | HSR Item 24.1.4-EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.HSR Rate(Rs.) 8275.00 Through Rate |
| 290 | HSR Item 24.1.8-EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.HSR Rate(Rs.) 96.00 Through Rate |
| 291 | HSR Item 23.22.1.3-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KAHSR Rate(Rs.) 4635.00 Through Rate |
| 292 | HSR Item 23.8.11.8-FITTING AND ACCESSORIES 11.8.Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular typeHSR Rate(Rs.) 75.00 Through Rate |
| 293 | HSR Item 24.1.9-EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.HSR Rate(Rs.) 730.00 Through Rate |
| 294 | HSR Item 24.2.6.3-LT CABLE 6.3. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 4 sqmmHSR Rate(Rs.) 5.00 Through Rate |
| 295 | HSR Item 23.22.4.8-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 4.8. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing)HSR Rate(Rs.) 5755.00 Through Rate |
| 296 | HSR Item 24.1.10-EARTHING AND LIGHTENINGARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.HSR Rate(Rs.) 730.00 Through Rate |
| 297 | HSR Item 23.8.10.2-FITTING AND ACCESSORIES 10.2.Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 3 ModulesHSR Rate(Rs.) 127.00 Through Rate |
| 298 | HSR Item 23.8.11.1-FITTING AND ACCESSORIES 11.1.Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch HSR Rate(Rs.) 41.00 Through Rate |
| 299 | HSR Item 23.20-Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as requiredHSR Rate(Rs.) 67.00 Through Rate |
| 300 | HSR Item 23.7.6.2-PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply anderection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.HSR Rate(Rs.) 32.00 Through Rate |
| 301 | HSR Item 23.7.6.4-PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia.HSR Rate(Rs.) 57.00 Through Rate |
| 302 | HSR Item 24.2.8.13-LT CABLE 8.13. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 240 sqmmHSR Rate(Rs.) 71.00 Through Rate |
| 303 | HSR Item 24.3.3.1-HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmmHSR Rate(Rs.) 7149.00 Through Rate |
| 304 | HSR Item 20.86-Supply, erection, testing and commissioning of G.O. Switch two poles, with blade, pin 6 insulators operating handle with GI pipe 25 mm class B complete in all respects.HSR Rate(Rs.) 36814.00 Through Rate |
| 305 | HSR Item 24.14.62-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 62. 95 Sq mm 3.5 core (Arm.)HSR Rate(Rs.) 572.00 Through Rate |
| 306 | HSR Item 24.14.46-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 46. 50 Sq mm 3.5core (Arm.)HSR Rate(Rs.) 350.00 Through Rate |
| 307 | HSR Item 20.72-Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge.HSR Rate(Rs.) 1339.00 Through Rate |
| 308 | HSR Item 23.3.6.3-COPPER WIRING IN PVC CONDUIT(SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm (1/2.24mm)HSR Rate(Rs.) 144.00 Through Rate |
| 309 | HSR Item 23.22.5.8-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:-40 amp to 63 amp. MCBs FOUR POLEHSR Rate(Rs.) 1291.00 Through Rate |
| 310 | HSR Item 23.22.1.9-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA HSR Rate(Rs.) 6130.00 Through Rate |
| 311 | HSR Item 23.22.1.11-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA HSR Rate(Rs.) 10809.00 Through Rate |
| 312 | HSR Item 23.22.1.12-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA HSR Rate(Rs.) 20350.00 Through Rate |
| 313 | HSR Item 23.22.5.4-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:-40 amp to 63 amp. Double poleHSR Rate(Rs.) 677.00 Through Rate |
| 314 | HSR Item 23.22.1.10-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA HSR Rate(Rs.) 6695.00 Through Rate |
| 315 | HSR Item 23.22.2.2-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 2.2. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 250 A FPHSR Rate(Rs.) 4032.00 Through Rate |
| 316 | HSR Item 23.22.6.2-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 6.2. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 40 AHSR Rate(Rs.) 1670.00 Through Rate |
| 317 | HSR Item 23.22.6.3-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 6.3. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 63 AHSR Rate(Rs.) 2075.00 Through Rate |
| 318 | HSR Item 23.4.4.3-COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.3.Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group CHSR Rate(Rs.) 935.00 Through Rate |
| 319 | HSR Item 24.2.8.14-LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmmHSR Rate(Rs.) 91.00 Through Rate |
| 320 | HSR Item 24.2.8.4-LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmmHSR Rate(Rs.) 8.00 Through Rate |
| 321 | HSR Item 24.2.8.8-LT CABLE 8.8. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 70 sqmmHSR Rate(Rs.) 20.00 Through Rate |
| 322 | HSR Item 24.2.6.2-LT CABLE 6.2. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 2.5 sqmmHSR Rate(Rs.) 4.00 Through Rate |
| 323 | HSR Item 24.2.7.7-LT CABLE 7.7. Supply and erection of suitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmm Cable 3 to 3½ CoreHSR Rate(Rs.) 227.00 Through Rate |
| 324 | HSR Item 23.8.10.4-FITTING AND ACCESSORIES 10.4.Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 ModulesHSR Rate(Rs.) 186.00 Through Rate |
| 325 | HSR Item 23.22.4.6-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 4.6. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing)HSR Rate(Rs.) 3276.00 Through Rate |
| 326 | HSR Item 24.2.6.1-LT CABLE 6.1. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work 1.5 sqmm.HSR Rate(Rs.) 4.00 Through Rate |
| 327 | HSR Item 24.1.5-EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.HSR Rate(Rs.) 801.00 Through Rate |
| 328 | HSR Item 24.1.7-EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.HSR Rate(Rs.) 360.00 Through Rate |
| 329 | HSR Item 23.3.6.4-COPPER WIRING IN PVC CONDUIT(SURFACE/RECESS) 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 6 Sqmm (1/2.80mm)HSR Rate(Rs.) 172.00 Through Rate |
| 330 | HSR Item 23.23.6.3-MISCELLANEOUS 6.3. Supply anderection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 375 X 50 X 2 mmHSR Rate(Rs.) 397.00 Through Rate |
| 331 | HSR Item 23.23.6.4-MISCELLANEOUS 6.4. Supply anderection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 600 X 50 X 2 mmHSR Rate(Rs.) 474.00 Through Rate |
| 332 | HSR Item 23.23.7.1-MISCELLANEOUS 7.1. Supply anderection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 100 X 50 X 2 mmHSR Rate(Rs.) 203.00 Through Rate |
| 333 | HSR Item 23.23.7.3-MISCELLANEOUS 7.3. Supply anderection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 375 X 50 X 2 mm metreHSR Rate(Rs.) 588.00 Through Rate |
| 334 | HSR Item 23.23.7.4-MISCELLANEOUS 7.4. Supply anderection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 600 X 50 X 2 mmHSR Rate(Rs.) 985.00 Through Rate |
| 335 | HSR Item 23.22.4.3-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 4.3. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 12 way ( 2 incoming and 10 outgoing)HSR Rate(Rs.) 1706.00 Through Rate |
| 336 | HSR Item 24.1.13-EARTHING AND LIGHTENINGARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required.HSR Rate(Rs.) 21.00 Through Rate |
| 337 | HSR Item 24.1.14-EARTHING AND LIGHTENINGARRESTOR 14. Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size.HSR Rate(Rs.) 62.00 Through Rate |
| 338 | HSR Item 24.1.16-EARTHING AND LIGHTENINGARRESTOR 16. Supply and erection of 25mm dia 1.5 metre long lightning GI. tube rod tapered into a point at the top with 16cm x 16cm x 3mm thick G.I. base plate and necessary nuts and bolts with washers.HSR Rate(Rs.) 898.00 Through Rate |
| 339 | HSR Item 23.21-Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as requiredHSR Rate(Rs.) 48.00 Through Rate |
| 340 | HSR Item 24.2.10-LT CABLE 10. Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S. Rod welded/riveted at the top with 10 cm dia 3 mm thick MS plate inscribed with cable word on it, having a cross arm 30 cm long of the same dia welded at the bottom, in exiting trench 45 cm below ground level.HSR Rate(Rs.) 240.00 Through Rate |
| 341 | HSR Item 24.3.4.2-HT CABLE 4.2. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 150 to 185 sqmmHSR Rate(Rs.) 13199.00 Through Rate |
| 342 | HSR Item 23.22.8.1-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 8.1. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 63 amp 415 voltsHSR Rate(Rs.) 6348.00 Through Rate |
| 343 | HSR Item 24.14.32-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OFTHE WORK 32. 25 Sq mm 4 core (Arm.)HSR Rate(Rs.) 226.00 Through Rate |
| 344 | HSR Item 24.16.7-HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 7. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 185 Sq mm 3 coreHSR Rate(Rs.) 1531.00 Through Rate |
| 345 | HSR Item 22.11.1-Providing and fixing draining board with C.I. brackets including painting of brackets, cutting and making good the walls wherever required : 1. White glazed fire clay draining board of size 600x450x 25 mmHSR Rate(Rs.) 911.00 Through Rate |
| 346 | NS Item -Supply, erection, testing and commissioning of LIFT ERD/online UPS system For 16 to 20 Passenger Lift with following details : Lift motor load:10.8Kw, Rated current:31.7A, 3Phase in 3Phase Out, With inbuilt isolation transformer, Micro controller based IGBT technology, Advanced technology: DSP based controller for power and monitoring, True online dual conversion design. Battery Backup for 15-20 mins, A. 30nos.*12V/42AH 30Kva. Heavy duty angle iron racks plus fire retardant copper battery interlinks AC Input 340-460 Volts AC Three Phase, DC Input 360 Volts DC, AC Ouput 400 Volts AC Three Phase, Sine Wave, Stability plus -1%, Cooling Force Air Cooled, Frequency 50Hz plus -0.5Hz, Total Harmonic Distortion Less than 2% on linear load, Inverter Efficiency More than 90%, Power Factor 0.8, Manual By Pass Provided, Input/Output Termination provided, Switching Frequency 10Khz, KW Rating 0.7 times the KVA Rating, IP Rating IP 20, Overload 110% for one minute, Technology DSP based, IGBT Switching, Charger Type CVCC (Constant voltage constant current), Isolation Transformer Build in Isolation Transformer at inverter output, Protection Over Voltage short circuit and overload at output terminal, Low Battery and high batter cut off, Digital LCD Display R,Y,B Input and output voltage, output current and frequency, DC Voltage and charging current, Regenerative Power Equipped to handle regenerative power of the lift motor, AC Input MCB/MCCB TP MCB/MCCB at the mains input, DC Circuit Breaker DC MCB/MCCB at the battery input, Indicators Mains, Battery charging, UPS ON, Output Overload, Battery Low and UPS Trip, Alarm Battery Low, overload and UPS Trip, Static Bypass Optional IS 17900 complete in all Respect. |
| 347 | NS Item -Supply, Installation, Testing and Commissioning of 16 passengers (B plus S plus 4) as per IS -17900 lift material hair line the following specifications complete in all respect as per direction of Engineer-in- charge.` Elevator Function - Person Elevator Capacity / Number of passengers - 1088 kg / 16 Passengers Speed - 1.0 m/s Number of Stops / Entrances- 5 (B plus S, 1, 2, 3, 4,) Main stop 1 (B) Travel height - 16.65 m Machine room - Machine room less Headroom - 4500 mm Pit depth - 1400 mm Shaft dimensions W x D - 2500 mm x 2500 mm Building tolerance -40 mm / plus 40 mm Car Door size W x H - 900 mm x 2000 mm Car Door Type - Door center opening, 2 panels Landing door Drive Power - 7.8 kW Main connection - TN-S (3L plus PE plus N) Main power supply - 415 V 50 Hz Light power supply - 230 V. Applicable codes( IS 14665/15259/NBC)Traction (Gearless), Variable Voltage Variable Frequency AC (VVVF) lift drives,for more power saving, comfort saft ride Controller type (microprocessor-based), Safety Features (Emergency alarm C intercom, Overload indicator with buzzer, Emergency light C fan in car),, Granite flooring on heavy duty M.S. Platform, Half side mirror at rear Side, SS Single round three side handrail and decorative false ceiling with LED lighting ,Brail Buttons, blower fan Control( High Performance Simplex Full Collective Control System Automatic rescue device in case of power failure or emergency landing (ARD) Fireman switch safety device as per elevator and escalator act. Overload warning device (OLWD) Complete in all respect |
| 348 | NS Item -Supply , Installation , Testing And Commissioning of up and down Escalator Having Following Specifications Complete in all Respect as per Direction of engineer in charge:-Technical Specifications:-Arrangement1) Type of equipment – Escalator ( Indoor Heavy duty, Applicable standard – Should meet the latest standard IS 4591/ EN115/ NBC, Vertical Rise – 4300 mm, Inclination – 35 degree, Speed- 0.5 mps, Step Width – 1000 mm, Horizontal Step – 02 nos, Step material – silver colour, Alluminium Die cast having yellow demarcation 03 side, Balustrade – 10 mm Tempered glass having 1000 mm height. Truss – Angle Iron with Hot dip Galvanised Comb – Alluminium, Hand rail – Synthetic Rubber having Black colour, Hand Rail Inlet – stainless steel, Inner / outer decking – Stainless steel, landing Plate – Alluminium, Control panel – VVVF drive , Enclosure having IP -54 Protection. Motor – Suitable rating having IP-54 protection and Efficiency IE- 3 .Auto Lubrication. auto – start stop with sensor ( energy saving mode ) Fault / Traffic indicator at both end, Comb lighting step gap Light, Emergency Stop Switch at Both End, Key switch at Both end. Direction of rotation – Both direction ( Forwardand reverse) Short circuit Protection, Overload protection. Phase monitoring and failure protection. Inspection running from Both ends. Floor plate safety at each section, Main drive chain safety Skirt panel safety, Hand Rail entry safety Device, Step Chain Safety Device. Comb plate safety device. Hand Rail speed Monitoring. Step Missing switch. Over speed and under speed Monitor. Step Anti Up thrust Device. Earth Leakage protection. Brake release Monitoring switch. Motor Overheat Protection. Hand rail Anti static roller Step Anti staic Brush. Saree/ Dress Guard. Fire Interface, Anti reversal Monitor, BMS integration, Outer cladding – 03 side (Stainless steel) Supply Voltage – 3 phase , 415 V ( plus /- 10 % ) , 50 HZ |
| 349 | NS Item -Supply and erection of R.D. fuses fixed on 2 Nos. channels of (set of 6 Nos) insulators pactel make size 75 mmx40 mmx6mm 2.25 mt. long with the help of suitable sizes of MS clamps, nuts and bolts i/c painting necessary connectiona and labour on existing pole complete in all respect |
| 350 | NS Item -Supply of PVC/ XLPE insulated (Heavy Duty ) Electrical cables for working voltage upto 1100 volt to IS: 1554 (PART-1) with Copper Conductor- ISI Marked Power Cable-Copper Conductor (2.5 sqmm 4 core unarmoured as per requirment). Make as per approved brand list of HPHC.. |
| 351 | LED Linear Profile (AC)Supplying Installation, Testing and Commissioning of LED RGB/ RGBWW/ RGBNW/ RGBA/ RGBW (as per site requirement) Linear Profile / Wall Washer luminaire for Facade lighting with aluminium extruded/ Die Cast housing with inbuilt driver of following wattage as given below. The luminaire bracket shall be made of cold-rolled steel and shall be so designed that the luminaire can be tilted to ±90°, having the rotation degrees scale shall be provided. The luminaire shall be IP66 protection also having silicon gasket between optical cover and LED chamber to ensure proper IP66 protection. CRI)80, SDCM(5, THD(10%. as per IEC 61000-3-2, under voltage, over voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD) of 10 KV common mode/differential mode, Driver Efficiency)85%, EMI/EMC as per CISPR-15. There should be options of beam angles of 10/20/30/40/60, asymmetric degree. Luminaire should have efficacy of minimum 40 lm/W for RGB/ RGBNW/ RGBWW/TNW and 65 lm/W for mono colour options.Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement.` |
| 352 | Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor )0.9. Fixture shall be suitable to operate at an ambient temperature range of - -10°C to plus 50°C and shall have impact resistance of IK 07. Lifetime of complete luminaire (LED ,Driver , Electrical and control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with weather proof ISI Marked copper conductor of minimum size 1.5sqmm connection cables and accessories , Integral male/female water proof connectors of IP68 etc. as required. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve and LM80 report issued by LED manufacturer, Rohs Compliance.Wattage per meter` (100 watt) |
| 353 | NS Item -Supply of indoor wall light made of aluminium with chrome/silver finish. The luminaire should be of 12W and offer at least 420 lumen at 3000K. Dimensions in mm are 500mm x 180mm x95mm.luminaire: Efficacy ˜ 35 lm/W is very low. Driver Spec (Input voltage range (e.g., 140–270V), Power factor = 0.90 / 0.95, Constant current driver), Diffuser / Optics (Opal diffuser / clear diffuser) LED buring life 50000 hrs Make as per HPHC approved Brand List |
| 354 | NS Item -SITC of LED Light 36 Watt 2`x2` Size (Recess Type) operation on single phase AC Supply including inbuilt LED Driver with constant current. lumens = 100 lumens /watt , 6500 K Cool white colour, input voltage 220-240,frequancy 50 Hz, power facto = 0.85, Protection IP20 for indoor and IP = 65 for outdoor fixtures. The body die cast aluminium powder coated. Temprature range -10 degree to plus 45°,THD (10%, surge protection = 2.5 KV, buring hours = 40000 Hours Complete in all respect. Make as per HPHC approved Brand List. |
| 355 | NS Item -SITC of LED Flood Light 100 Watt operation on single phase AC Supply including inbuilt LED Driver with constant current. lumens = 100 lumens /watt , 6500 K Cool white colour, input voltage 220-240,frequancy 50 Hz, power factor = 0.85, Protection IP20 for indoor and IP = 65 for outdoor fixtures. The body die cast aluminium powder coated. Temprature range -10 degree to plus 45°,THD (10%, surge protection = 2.5 KV, burning hours = 40000 Hours, BIS Certified Complete in all respect. Make as per HPHC approved Brand List |
| 356 | NS Item -SITC of LED Flood Light 200 Watt operation on single phase AC Supply including inbuilt LED Driver with constant current. lumens = 100 lumens /watt , 6500 K Cool white colour, input voltage 220-240,frequancy 50 Hz, power factor = 0.85, Protection IP20 for indoor and IP = 65 for outdoor fixtures. Made up of Pressure die cast aluminium powder coated. Temprature range -10 degree to plus 45°,THD (10%, surge protection = 2.5 KV, burning hours = 40000 Hours, BIS Certified Complete in all respect. Make as per HPHC approved Brand List |
| 357 | NS Item -SITC of Steel Poles 4 meter long are made out of galvanized Mild Steel tubes having 114mmx4mmx1000mm dia at bottom and 75mmx3mmx3000mm dia at Top with cast aluminium emb.- Z4. The Poles are primer coated and painted with polyurethane paint. The pole has a service window at the bottom comprising four way 25amp connector terminal and a MCB poles has a mild steel base plate having four numbers mounting holes and can be mounted with four numbers anchor bolts Decorative Steel Poles 4 meter long made of Galvanizati mild steel and having bottom section 1000 x 114 mm x 4 mm and top section of 3000x 75 mm x 3 mm . Pole is having casted designer embellishments in the middle and bottom. Pole should be Polyurethane painted. Base Plate should be of 250 x 250 x 10 mm minimum.Detail, Service Window is having 6 amp mcb with connector for loop in loop out cable connections. Foundation should be M2 grade of 3 feet depth and 350x 350 mm and nuts and bolts of 16 mm x 24 inchesas par our (Make:- Twinkle Luxmax or Equivalent. |
| 358 | NS Item -SITC of 40W LED Post Top fixture made out of cast aluminium body with four nos. die cast alumjnium arms, frosted PMMA/ PC diffuser with power LED,s are mounted directly on extruded aluminium heat sink and Electronic Driver. with poly carbonate diffuser . Leds are mounting on the pcb clad and extruded heat sinks having 100 lm per watt minimum , life 50000 burning hours , Driver is with Power factor = 0.95 , Input voltage range (e.g., 140–270V), Constant current driver, Colour Temperature 4000K , Housing and fixture is Powder coated, Environmental Conditions Outdoor use , Temperature range (e.g., -10°C to plus 50°C).(Make:- Twinkle tuxmar ) or Equivalent |
| 359 | NS Item -SITC of mounted deep recessed Round Shape COB light 27watt) ( LED Life L70 ) 50000 hrs, system lumen efficacy = 2700 Lumens. Made of aluminium Extrusion with housing part in Anodize finish and diffuser part in opal Finish,THD(= 10% , PF= 0.85 , IP20 , CCT - 5700K , CRI)80 ,Complete in all respect BIS certified Make as per HPHC Brand list |
| 360 | NS Item -SITC of indoor wall light made of aluminium with chrome/ finish. The luminaire should be of 12W and offer at least 420 lumen. Dimensions in mm are 500mm x 180mm x95mm THD(= 10% ,,PF= 0.85 IP20 , CCT - 3000K , CRI)80 , BIS certification to be provided complete in all respect. |
| 361 | NS Item -SITC of Surface Downlight 24 W ( CCT- 5700K, LED Life L70 ) = 40000 hrs, system lumen efficacy 2400 Lumens. White powder coated, elegantly designed pressure die-cast aluminium heat sink THD(= 10% ,PF = 0.85 , IP20 , CCT - 5700K , CRI)80 , BIS certification to be provided Complete in all respect |
| 362 | NS Item -SITC of Recess Downlighter 15 W system lumen efficacy 1500 Lumens. White powder coated, elegantly designed pressure die-cast aluminium heat sink for efficient dissipation THD(= 10% , PF = 0.85 , IP20 , CCT - 5700K , CRI)80 , BIS certification to be provided Complete in all respect. |
| 363 | NS Item -Supplying Installation Testing and Commissioning of push button Type keypad with 10 buttons DMX512. Each button is programmable up to 16 scenarios. Also has got two dry-contact input to trigger any preset scene, etc as required Complete in all Respect. BIS Certified |
| 364 | NS Item -SITC of 5 pin XLR Male/Female connectors having 5 pole cable connector, Male/Female connector Electrical rating Voltage (110/230 V) Current (5A -15 A) with improved latch, cage type contacts, `solder stop` for easy soldering, and additional ground contact for best contact integrity between chassis and cable connector. More durable housing for maximum reliability BIS Certified Complete in all respect |
| 365 | NS Item -SITC of IP65 ``I`` DMX connectors having 3/5 pole cable connector, Male/Female connector with improved latch, cage type contacts, ``solder stop`` for easy soldering, and additional ground contact for best contact integrity between chassis and cable connector. More durable housing for maximum reliability, Electrical :- Suitable for low voltage data trransmission with proper shielding and Grounding . made high quality Brass Warranty 05 years BIS Certified Complete in all respect |
| 366 | NS Item -SITC of IP65 ``I`` power connectors having 3/4 pole cable connector, chuck type strain relief, Current rating 20 A Rms continuous, Easy and extremely precise locking system``Quick Lock`` High impact materials - long-lasting and reliable, Electrical :- Suitable for low voltage data trransmission with proper shielding and Grounding etc Warranty 05 years BIS Certified complete in all respect |
| 367 | NS Item -SITC of high quality DMX decoder, Power Input : DC 24V Warranty 05 years Output Current 3A- 8A .IP Rating = 20 perating Temp (-20° to plus 60° with CE certified etc BIS Certified complete in all respect |
| 368 | NS Item -SITC of Signal Amplifier to boost the Signal, Rated module to enhance the depleting DMX Signals, should have IP Rating IP 20 Input Voltage AC 100 to 240 V 50 HZ, DC 12 to 24 v. Power Cunsumption (5w - 15w) Over voltage Protection .short circuit Protection Operating Temp (- 20° to 50°) rates inbuilt connectors compatible with Luminaires. It should be offered with inbuilt electronic circuit for functioning. No external LED driver needed etc.,warranty 05 years BIS certified complete in all respect. |
| 369 | NS Item -Supplying Installation, Testing and Commissioning of RDM-6Wall Splitter, should be able to provide 6-output DMX/RDM splitter with DMX/RDM pass□through supporting bi-directional communications for discovery, addressing and DMX control of Ethernet/DMX products. This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6x32. The output terminals are electronically isolated from the input and RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Surface or DIN-rail mountable, Isolated DMX/RDM Input/Outputs, Automatic switching between DMX and RDM mode for auto-discovery, Environment-IP20, Interior applications, Finish/ Color□Polycarbonate Enclousure 6 output RDM , Power supply - I/P Voltage 100 - 240 V Certification: CE Certified. DMX Splitter/ Booster etc. operating temprature 10 to 45° IP 20 Complete in all respect |
| 370 | NS Item -SITC of DMX Splitter with Input Voltage range : 190-240V AC, Power Consumption 5W max. Housing is made of CRCA with powder coated finish Mounting, 19 inch rack mountable, Operation Temperature - 30°C to plus 55°C, 8 Output with 3pin XLR terminal sockets,Ingress Protection Rating IP20. This unit takes theDMX Signal from DMX Controller and split the signal into 8 separate output channels. The output terminals of Splitters are optically isolated from the input. Splitters should be capable to amplify the DMX signal and allowing the data link to be extended by max. 300 m (1044 ft.) using AWG 22 DMX cable or 150 m (500 ft.) using AWG 24 DMX cable or maximum 20-25 fixture per output channel. To be provided with IP enclosure if installed in external environment etc.Protection surge or ESD ,power supply AC 90 to 240 V 50 HZ , power consumption 5W - 15W. short circuit protection / Over voltage protection BIS certified complete in all respect |
| 371 | NS Item -SITC of DMX Controller for the system including address writer and programming the DMX controller with the suitable designs as decided by the Engineer-in-charge/client department ( not less than 10 nos designs) and all other accessories required for the running of the system Controller should have Input Power 5-5.5V DC 0.6A and Output Protocol DMX512 with 4 universe, 2 universe should work in Stand Alone Mode and 2 universe should work in live mode with laptop/ tablet / computer. The universe should be expandable from 2 to 4 DMX512 universes. It should be compatible for Programmability with PC, Mac, Tablet, Smartphone by using USB and Ethernet. Dmx controller should have network controllability feature to control the scene remotely through LAN and triggered via UDP packets on port 2430. It’s must have Connections Type C USB, XLR3, Ethernet, battery.There should be provision for Memory microSD card. Device should have Intuitive backlit keyboard with 10 presents and also have provision of keypad on device for changing scene manually from device. Device should be capable to work on Extended triggering possibilities (TCA) and also have Smart Upgrade Technology (SUT). It is an IP 20 unit and has an Operating Temperature of 0°C to 50°C.OS Requirements for the controller is Mac OS X 10.8-10.12, Windows 7/8/10/11. Standards should be EC, EMC, ROHS. The controller should have a variety of features including 2048 DMX channels, clock/calendar, iPhone/iPad /Android remote control, Ethernet facilities, dry contact port triggering and multi-zone SD card memory. Network synchronization of one area across hundreds of universes with the possibility of 99 scenes across 5 areas with auto clock triggering for sunrise and sunset and as per the festivals for specific occasions. Device should be equipped with meta clamp to mount on wall with data enablers and splitters as required. To be provided with IP 66 enclosure if installed in external environment RDM support with CE Certified , Effect - dimmer , strobe , Colour mixing.Power supply AC 100 - 240 v,50 HZ.Power Consumption 10w-50w BIS certified Complete in all respect. |
| 372 | NS Item -`SITC of LED RGB /RGBWW/ RGBNW/RGBA/RGBW suitable for exterior use having IP68 rating (as per site requirement). Flexible light strip of 5 mtr standard length with 12-15 Watt per meter. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. Minimum System lumens 450 lumens/meter and System Lumen Efficacy ) 30lm/w. Luminaire light beam spread - 100-110°, The Strip should have IP 68 protection and is offered IP 68 rated connectors to join the LED Strips in continuity. The luminaire must be offered with Aluminium channel for mounting the strip lights. The product should be complete with all accessories and Driver. Lifetime of complete luminaire (LED, Driver, Electrical and control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) with dully R Number marked. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 24 V DC, Fixture shall be suitable to operate at an ambient temperature range of -10°C to plus 50°C. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79. report from NABL accredited lab, illuminance diagram, polar curve and LM80 report issued by LED manufacturer and RoHS Compliance along with CE certificate Flexible light strip of 5 mtr standard length with 12-15 Watt per meter. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control.Minimum System lumens 450 lumens/meter and System Lumen Efficacy ) 30lm/w.BIS Certified Complete in all respect |
| 373 | NS Item -SITC of LED 60 Watt RGB/ RGBWW/ RGBNW/RGBA/ RGBW (as per site requirement) Linear Profile / Wall Washer luminaire for Facade lighting with aluminium extruded/ Die Cast housing with inbuilt driver of following wattage as given below. The luminaire bracket shall be made of cold-rolled steel and shall be so designed that the luminaire can be tilted to ±90°, having the rotation degrees scale shall be provided. The luminaire shall be IP66 protection also having silicon gasket between optical cover and LED chamber to ensure proper IP66 protection. CRI)80, SDCM(5, THD (10%. as per IEC 61000-32, under voltage, over voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD) of 10 KV common mode/differential mode, Driver Efficiency)85%, EMI/EMC as per CISPR-15.There should be options of beam angles of 10/20/30/40/60, asymmetric degree. Luminaire should have efficacy of minimum 40 lm/W for RGB/ RGBNW/ RGBWW/TNW and 65 lm/W for mono colour options. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement.`` Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor )0.9. Fixture shall be suitable to operate at an ambient temperature range of - -10°C to plus 50°C and shall have impact resistance of IK 07. Lifetime of complete luminaire (LED ,Driver , Electrical and control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with weather proof ISI Marked copper conductor of minimum size 1.5sqmm connection cables and accessories , Integral male/female water proof connectors of IP68 etc. as required. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve and LM80 report issued by LED manufacturer, Rohs Compliance.Wattage per meter`Luminaire should have efficacy of minimum 40 lm/W for RGB/ RGBNW/ RGBWW/TNW and 65 lm/W for mono colour options. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control.BIS Certified Complete in all respect |
| 374 | SITC of 30 KW (single gun) Three Phase DC Fast Charger(with Electrical cabling and Protection Device ,Civil Foundation work, Canopy support,Branding and Signage) Type: DC CCS2 Charger Power Output: 30 kW , Charging Time: 1–2 hours ,Efficiency: )96% Display: 10” LCD Touch,Authentication: RFID / App / QR , Connectivity: LAN / GSM / Wi-Fi Safety: IP54, IK10, 18 plus protections Input Power Input Voltage (AC) 3 Phase, 415VAC plus 10% or -6%, Frequency 50 Hz, Wires 5 Wire AC System (3Ph, N, PE), THD (5% of Nominal Voltage (IEEE 519 Compliant), Power Factor)0.98 (Full Load), Output Power Number of Outputs 1, Output Current Max. 80 Amps, Output Power Max. 30Kw, Output Connector CCS2, DC Output Voltage 200V-1000V DC, Efficiency )0.95%, Environment Operating Temperature -250 C to 550 C, Storage Temperature -250 C to 850 C, Altitude Up to 3500 meters, Humidity 5% to 95%, non-condensing, User interface and control Display Screen 70C TFT LCD |
| 375 | Touchscreen, Language Supported English (Customizable to local language), Push Buttons Mushroom Type Emergency stop, Charge Option Grid Responsive Metering, Visual Indication Error Indicator: SoC Presence of Input Supply, Display Message As per CCS specifications, User Authentication Using mobile application or RFID Card (ISO/IEC 14443), Payment Smart card, QR/OTP/APP Server based online payment, Safety Protection Over Voltage, Under Voltage, Over Current, surge protection device, reverse Polarity Protection, Emergency Shutdown, NE (Neutral-Earth) Voltage Tripping, Inbuilt RCMU, EMC IEC 61000-4, Compliance IEC 62196, IEC 61851 Isolation Double isulation. Each DC output should be isolated from each other (ICB1851-23 Communication charger and vehicle PLC Based Communication as per AISI3B Part-2 OCPP 1.6J/100 Base-T Ethernet (Standard)/ Wi-Fi (802.11b/g/n) optional GSM Modem (4G LTE) Mechanical Cable Length 5 meters IP Rating/Cooling IP-55/ Forced Natural Air Cooling Impact IK 10 (Screen:IK 08) Structure Stainless Steel Dimensions (mm) 620(w)x1700(h)x500(d) Weight (Kg) 210 Management:-Input supply failure 15 minutes for control system and billing unit (Battery Backup) Power Management Dynamically manage the power distribution as per load Remote Management Manage via the admin portal, and/or API Service and Maintanance Remote system monitoring, diagnostic, and proactive maintenance. Complete in all respect |
| 376 | SITC of 60 KW (Dual Gun) Three Phase DC Fast Charger (with Electrical cabling and Protection Device ,Civil Foundation work, Canopy support,Branding and Signage) Type: DC CCS2 Charger Power Output: 60 kW Charging Time: 45–60 minutes Efficiency: )96% Display: 10” LCD Touch Authentication: RFID / App / QR Connectivity: LAN / GSM /Wi-Fi Safety: IP54, IK10, 18 plus protectionsInput Power Input Voltage (AC) 3 Phase, 415VAC plus 10% or -6%, Frequency 50 Hz, Wires 5 Wire AC System (3Ph, N, PE), THD (5% of Nominal Voltage (IEEE 519 Compliant), Power Factor )0.98 (Full Load), Output Power Number of Outputs 1, Output Current Max. 80 Amps, Output Power Max. 30Kw, Output Connector CCS2, DC Output Voltage 200V-1000V DC, Efficiency )0.95%, Environment Operating Temperature -250 C to 550 C, Storage Temperature -250 C to 850 C, Altitude Up to 3500 meters, Humidity 5% to 95%, non-condensing, User interface and control Display Screen 70C TFT LCD Touchscreen, Language Supported English (Customizable to local language), Push Buttons Mushroom Type Emergency stop, Charge Option Grid Responsive Metering, Visual Indication Error Indicator: SoC Presence of Input Supply, Display Message As per CCS specifications, User Authentication Using mobile application or RFID Card (ISO/IEC 14443), Payment Smart card, QR/OTP/APP Server based online payment, Safety Protection Over Voltage, Under Voltage, Over Current, surge protection device, reverse Polarity Protection, Emergency Shutdown, NE (Neutral-Earth) Voltage Tripping, Inbuilt RCMU, EMC IEC 61000-4, Compliance IEC 62196, IEC 61851 Isolation Double isulation. Each DC output should be isolated from each other (ICB1851-23 Communication charger and vehicle PLC Based |
| 377 | Communication as per AISI3B Part-2 OCPP 1.6J/100 Base-T Ethernet (Standard)/ Wi-Fi (802.11b/g/n) optional GSM Modem (4G LTE) Mechanical Cable Length 5 meters IP Rating/Cooling IP-55/ Forced Natural Air Cooling Impact IK 10 (Screen:IK 08) Structure Stainless Steel Dimensions (mm) 620(w)x1700(h)x500(d) Weight (Kg) 210 Management:-Input supply failure 15 minutes for control system and billing unit (Battery Backup) Power Management Dynamically manage the power distribution as per load Remote Management Manage via the admin portal, and/or API Service and Maintanance Remote system monitoring, diagnostic, and proactive maintenance.Complete in all respect |
| 378 | NS Item -SITC of Wall Fan 16`` Sweep ( 400mm) oscillating type light duty Rated speed 1350 RPM with inbuilt regulator, blade, jaalli, Copper wound Motor, PVC body 03 no.blade. Power Consumption 57w.Air Delivery 65m³/min 2 years warranty Complete in all Respect. |
| 379 | NS Item -SITC of PVC insulated unsheathed single core copper cable Size1.5 sqmm (FRLSH) for working voltage upto and including 1100 volts 694/2010 – ISI marked with Accessories BIS Certified complete in all respect.. |
| 380 | NS Item -SITC of PVC insulated unsheathed single core copper cable Size 4.00 sqmm (FRLSH) for working voltage upto and including 1100 volts 694/2010 – ISI marked with Accessories BIS Certified complete in all respect |
| 381 | NS Item -SITC of PVC insulated unsheathed single core copper cable Size 2.50 sqmm (FRLSH) for working voltage upto and including 1100 volts 694/2010 – ISI marked with Accessories BIS Certified complete in all respect |
| 382 | NS Item -SITC of PVC insulated unsheathed single core copper cable Size 6 sqmm (FRLSH) for working voltage upto and including 1100 volts 694/2010 – ISI marked with Accessories BIS Certified complete in all respect |
| 383 | NS Item -SITC of lightening arrestor model SDU suitable for 11 KV. 3 phase, 50 cycle, per second grounded neutral system comprising of spark gap type quench gap (Two Metal Electrodes) Elect in service with no linear resistor element housed in along with mountering clamps and confirming to ISS -3070 (Part-1) of 1988 with latest amendment on existing channels with labour and material required to complete the job in all respect upto entire satisfaction of Engineer-incharge of the work |
| 384 | NS Item -SITC of prestressed cement concrete (PCC) pole as per IS : 1678-1960, Height 11 meters long 152 mm x 203 mm at top and 152 mm x 368 mm at bottom with working load of 360 kg. burred 2.20 m in ground Including foundation of size 1`-0``x 1`-0``x6`-0`` in Grade of 1:1½ :3 Ratio Complete in all respect. |
| 385 | NS Item -SITC of Heavy duty bulkhead surface type lighting fixture 10W - 1000lm/w made up of pressure die-cast aluminium housing and Polyster Powder coated die cast aluminium with High quality polycarbonate diffuser in opal finish for glare free light distribution.High efficiency long life LED module with SMD LED package mounted on MCPCB with lumen efficacy of )100 lm/W. Powered by integral electronic LED driver with CCT 6500, CRI)80,THD(10%, PF)0.9, IP66, IK 09, Life class of 50,000 hrs @ L70, Operating Temperature: 0 TO plus 45 DEG.C: Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ. Driver Safety requirement standards:IS 15885,Test Report to be submitted, Photobiological Safety Norms: IS 16108, test Certificate to be submitted, Manufacturer shall have inhouse lab approved by NABL or Ministry of Science of Govt of India. LM79 and LM80 reports must be submitted from a NABL accredited laboratory. BIS certificate for driver as well as the luminaire must be submitted for records. Complete in all respect |
| 386 | NS Item -SITC of IP20 recessed LED Downlighter 20W made of pressure die cast aluminum housing with PC diffuser,Fixture should have minimum efficacy at System level (Not Chip Level) )=100 lumens/watt with Minimum system Lumens 2000 with maximum system wattage of 20W. Life of fixture (Including Driver) : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K (SDCM(5), CRI )80, PF=0.85 THD(10% (At Full Load) working temp range - 0°C ( Ta ( 45°C, and operating Voltage Range of 130-320 VAC. It should has a Minimum Internal Surge Protection of 2.5KV. Electronic Switchable ballast. The Luminaire shall be Class B serviceable, it shall have cutout dia of 150mm and product height not more than 40mm. The fixture should have BIS certification for LED Driver and Luminaire.with allied items BIS approved. Complete in all respect |
| 387 | NS Item -SITC of 12W IP20 recessed LED Downlightermade of pressure die cast aluminum housing with PC diffuser, Fixture should have minimum efficacy at System level (NotChip Level) )=100 lumens/watt with Minimum system Lumens 1200 with maximum system wattage of 12W. Life of fixture (Including Driver) : 50000 burning Hrs. Lumen maintenance, CCT of 6500K (SDCM(5), CRI )80, PF =0.85,THD(10% (At Full Load) working temp range -0°C ( Ta ( 45°C, and operating Voltage Range of 130-320 VAC. It should has a Minimum Internal Surge Protection of 2.5KV. Electronic Switchable ballast. The fixture should have BIS certification with allied items complete in all respect |
| 388 | NS Item -SITC of Recessed mounted deep recessed Round Shape Fixed spot light COB type, made up of pressure die-cast aluminium heat sink in white powder coated finish with glossy faceted reflector and clear glass,The luminaire shall deliver minimum of 3000 lumens with system efficacy of 100lm/w. Powered by electronic LED driver with Output Short-circuit protection, Surge protection 3.5KV. Color temperature 6500K PF =0.85, IP20. Dimensions: Cut out Dia-140 mm. The Luminaire shall be IP20 complaint. CRI= 80, SDCM(5. Beam Angle option of 34D.The driver of the LED downlighter shall be isolated driver and shall have minimum operating voltage of 140V to 270V, and THD=10%, Driver efficiency of = 85%. Life = 50,000 hrs, BIS certified .with allied items Complete in all Respect. |
| 389 | NS Item -SITC of recessed LED Downlighter 18W. made of pressure die cast aluminum housing with PC diffuser,Fixture should have minimum efficacy at System level (Not Chip Level) with system Lumens 1800 THD(= 10% , PF =0.85, IP20 , CCT - 5700K , CRI)80 , BIS Certified Complete in all respect |
| 390 | NS Item -SITC of outdoor 10w wall mounted light suitable for boundry walls and façade application.Housing made of synthetic material with frosted diffuser .Dimenson L 205 x W85 x H82 in mm.The fixture should have five sided glow,should be dust proof and water resistant.IP rating - IP65,wattage 10w,100 lm/w CCT-3000K,CRI)80,PF=0.85surge protection of 2.5KV,should have operating temperature of 45deg celcius and operating voltage of 140V-360V AC .with allied items BIS Certified Complete in all respect |
| 391 | NS Item -SITC of LED Light 20 Watt 4 feet long operation on single phase AC Supply including inbuilt LED Driver with constant current. lumens = 100 lumens /watt , 6500 K Cool white colour, input voltage 220-240,frequancy 50 Hz, power facto = 0.85, Protection IP20 for indoor and IP = 65 for outdoor fixtures. The body die cast aluminium powder coated. Temprature range -10 degree to plus 45°,THD (10%, buring hours = 20000 Hours BIS Certified Complete in all respect.Make as per HPHC approved Brand List |
| 392 | NS Item -Providing and fixing flow switch in following sizesM.S. pipe including connection etc as required 100mm dia |
| 393 | NS Item -Supplying, installation, testing and commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as reauired - 1500mm |
| 394 | HSR Item 22.181-Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.HSR Rate(Rs.) 7.00 Through Rate |
| 395 | NS Item - Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 150mm dia |
| 396 | NS Item -Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below:a) Providing, Installation, Testing and Commissioning of CO2 Type Fire Extinguisher complete with wheel valve arrangement, high-pressure wire braided hose pipe etc. As per IS : 2878Capacity: 4.5 Kg |
| 397 | Fabrication, Supply, installation, testing and commissioning of Electrical control panel of cubical construction floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged locked doors, dust and vermin proof, powder coated of approved shade after 7 tanki treatment process. cable alley, inter-connection with suitbale size copper conducter cable/soil copper strip, having switchgears and accessories mountings and internal wriing, earth, terminals, numbering etc. complete in all respect suitable for main pump pressursation pump and diesel pump set complete as per CPWD specification with following in coming and Outging suitable for operation on 415 V, 3 phase, 4 wires, 50 Hz power distribution system. Supply with enclosure protection class IP 42 as rquired. Adequate size cable alley shall be provided all round the panel and in the back for each cable bending and termination. The panel shall be fabricated by CPRI/TAC/Fire authority approved vendor.The outgoing feeders inside the panel shall be connected through solid bus bars. Flexible cable links are not acceptable.Bus bars shall be provided with heat shrinkable sleeves and shall be colour coded. The panels shall be suitable for cable entry from top. The minimum fault rupturing of all incoming and outgoing switches/breakers shall be 35 KA. The panels shall be fabricated after the approval of |
| 398 | fabrication drawings. Main Fire Pump Panel:Incoming Section:i) One (1) No. 400A TPN MCCB (35 KA)ii) 500 Amps Aluminium bus bar shall be insulated with heat shrinkable sleeves and shall be color coded.iii)current transformer (400/5A).iv) One (1) No. ammeter (0-800) Amps with selector switch.v) One (1) No. (0-500 V) voltmeter with selector switch.vi) 1 Set (3 Nos) of phase indication lamps with HRC fuses.vii) Indication for control supply `healthy`. Outgoing:i) 1 Nos. 400 A TPN MCCB 35 KA. 1 NOS.ii) 1 NoS. 63 A TPN MCCB 25 KA.iii) One(1) No. star delta Starters complete with . ON/OFF, indication lamp, contactors ammeter with suitable C.T`s, sufficient nos. of potential free spare contacts, etc. suitable for 75 HP motor.iv) Wiring from pressure switch to starter - Lotv) One (1) No. DOL Starter with single phase protection feature. ON/OFF, indication lamp, contactors ammeter with suitable C.T`s, sufficient nos. of potential free spare contacts, etc. suitable for 15 HP motor.vi) Set of control system to make the system automatic as per functional requirements. |
| 399 | vii) Wiring from pressure switch to starter – Lotviii) Provision for starting the diesel engine fire pump with battery charger for trickle and boost charging. The diesel engine driven fire pump shall start automatically in the event of pressure drop beyond preset limit on mains failure or failure of electrical driven pumps to start.ix) One (1) no. pressure switch.x) Wiring from pressure switch to Diesel engine control panel. Note:i) Separate neutral link to be provided wherever TP MCCB are used.ii) Following provisions to be made in the fire panel:a) Audio visual alarm and indications having disconnect/reset facility with a range of 1/2 km. Annunciator to be provided in the Fire panel with hooter and acknowledge, test and reset PBs. The indication shall come on when electrical driven pump set fails to start on pressure drop or when there is power failure during pressure drop.b) Facility for mode selection ie auto or manual test and local/remote. |
| 400 | c) Protection failure and control cabling.d) Panel shall be interlocked in such a way when fire pump starts on pressure drop in the header, supply to working chiller A/c panel is disconnected.e) Remote indication of ON/OFF/ TRIP shall be provided through potential free contact.f) Provision of remote starting/ stopping (manual) of the engine shall be made.DSR:-18.5.4 |
| 401 | NS Item - (A) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520(C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-325.(D) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(E) Suitable cement concrete foundation duly plastered and with anti vibration pads. (900 LPM) |
| 402 | NS Item -MS PIPE - Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100mm dia |
| 403 | NS Item -Providing and Fixing, testing and commission of Butterfly valve of PN -1.6 rating with bronze /gunmetals seat duly ISI marked complete with nuts, bolts washers, gaskets confirming to IS 13095 of following sizes as required. (Make:- b) 100 mm dia DSR:-18.11.5 |
| 404 | NS Item -Supply, erection, testing and commissioning of 4 WAY fire brigade inlet connection to wet riser system which comprises of 3 No. 63 mm dia Gun metal NRV, 1 No. powder coated weather proof standard hose box suitable for accommodating the above components fabricated out of 16 SWG MS sheet with central opening, glazed front incluiding necessary fittings the word FIRE BRIGADE DRAW OFF to be painted on the box complete all as specified and directed.(Make:-NEWAGE/ATASEE/ OMEX/SWASTIK)) |
| 405 | NS Item -Supply and fix MS Cabinet ( apporx 750mm x 600mm x 450 mm ) to encl fire brigade inlet connection fabricated from 16 gauge sheet with full front glass door and locking arrangement painted and mounted on masonry platform complete. |
| 406 | HSR Item 23.26.4-SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia).HSR Rate(Rs.) 2739.00 Through Rate |
| 407 | NS Item -DSR-18.21 Providing, fixing, testing and commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :18.21.1/2 Pendent / Upright Sprinkler |
| 408 | NS Item -Supplying, installation, testing and commissioning of ceiling hung / floor mounted vane/tube axial flow fans of following capacity with GSS casing/ standard M.S. construction and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiency IE2 for Emergency Supply, Pressurization and Smoke Exhaust Fans and IE3 for Normal Supply, and Exhaust Fans suitable for 3 Phase 50 Hz 415V ± 10 %. Motor shall be class `F` insulation for Fresh Air and Pressurization Fans and class `H` insulation for Exhaust Fans. Fire rated flexible connection etc. including all accessories complete as required and as per specifications.Motor of exhaust fans shall be of high temperature resistance`Class H Smoke Spill` 250° C for 2 hrs., Complete fan shall be AMCA certidied for Air and sound performance and CE listed in accordance in EN 12101-3:2015 All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating/Powder coating after phosphating process and complete with bird screen at inlet with louver and fan protection coul. Suitable TP isolator within MS enclosure should be provided. Gravity louvers will be provided at the discharge of the fan so as to avoid reverse flow. Static pressure shall be checked/verified by contractor prior to order. Complete as required as per site conditions. 22500 CFM / 18 MMWC TSP - FOR Exhaust Air |
| 409 | NS Item -MS PIPE - Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80mm dia |
| 410 | NS Item -SITC of Auto Glow Exit Signs and indication signs of Size 12” x 4” and Attack Fire, DP indication every exit point, Fire Point, Fire Extinguisher complete in all respect. |
| 411 | NS Item -Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. complete in all respect upto the entire satisfaction of Engineer - in - charge of the work including making necessary connections etc. (ii) 200 MM dia. |
| 412 | NS Item -Proving and fixing ISI Marked Dual Type Non-return valves flanged end class PN-1.6 as per IS:5312/2004 in pipe lines including jointing and cost of Nut Bolt , rubber insertion complete in all respect upto the entire satisfaction of Engineer- in - charge of the work including making necessary connections etc. i) 150mm dia (Dual Type NRV) |
| 413 | NS Item -FIRST AID HOSE REEL:-Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve and nozzle.Drum and brackets for fixing the equipments on wall. Connections from riser with 25 mm dia stop gun metal valve and M.S. Pipe and socket. |
| 414 | NS Item -Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required complete in all respect upto the entire satisfaction of Engineer - in - charge of the work including making necessary connections etc. Gun metal. |
| 415 | NS Item -Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS Sheet, 1200mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. complete in all respect upto the entire satisfaction of Engineer - in - charge of the work including making necessary connections etc. |
| 416 | NS Item -Supply and making end termination with brass compression glands and aluminim lugs for the following PVC insulated, PVC sheathed and 1100 V grade Aluminium cable including cost of crimping lugs/ferrules, compression glands, solder, cable sockets, insulation tape etc complete as required.b) 3C x 35 Sq.mm. DSR:-9.1.10 |
| 417 | NS Item -Supply and making end termination with brass compression glands and aluminim lugs for the following PVC insulated, PVC sheathed and 1100 V grade Aluminium cable including cost of crimping lugs/ferrules, compression glands, solder, cable sockets, insulation tape etc complete as required. a) 3C x 95 Sq.mm. DSR 9.1.13 |
| 418 | NS Item -MS PIPE - Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 40mm dia |
| 419 | NS Item -Providing and fixing of ISI marked (IS: 15683) portable ABC multipurpose mono monioum phosphate powder , nitrogen pressurised type fire extinguisher, Capacity 6 kg complete in all resp. (Atasee/Minimax/Kanex) |
| 420 | NS Item -Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A). complete in all respect upto the entire satisfaction of Engineer- in - charge of the work including making necessary connections etc. Stainless Steel (Grade 304). |
| 421 | NS Item -Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, 151 marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal |
| 422 | NS Item -Providing, fixing, testing and commissioning of C.I. Butterfly valve conforming to IS : 13095 with flanges, nuts, bolts and washers complete for following sizes :- [PN 1.6 rating]. a) 150 mm dia DSR-18.11.6 |
| 423 | NS Item -Providing and Fixing, testing and commission of Butterfly valve of PN -1.6 rating with bronze /gunmetals seat duly ISI marked complete with nuts, bolts washers, gaskets confirming to IS 13095 of following sizec) as required. (Make:) c) 80 mm dia DSR:-18.11.4 |
| 424 | NS Item -Supply and Erection C` class heavy duty MS Pipe 200 mm dia Complete in all respect upto satisfaction of Engineer in Charge. |
| 425 | NS Item -Providing and fixing air release valve of 25 mm dia and 25 mm dia gun metal gate valve with fittings etc. to be installed at risers. |
| 426 | NS Item -Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia |
| 427 | NS Item -Supply and installing ISI marked under (IS: 13386) 45 ltr. Capacity mechanical foam trolly mounted mobile fire extinguisher complete with braided discharge hose and intial charge of AFFF (Aquous Film Forming Foam) for D.G Set |
| 428 | NS Item -Supply and making end termination with brass compression glands and aluminim lugs for the following PVC insulated, PVC sheathed and 1100 V grade Aluminium cable including cost of crimping lugs/ferrules, compression glands, solder, cable sockets, insulation tape etc complete as required.c) Control Cable 4 C x 1.5 sq.mm. DSR:-1.17.4 |
| 429 | NS Item -Providing, fixing, testing and commissioning of non-return valve complete with nuts, bolts and washers. b) 100 mm dia DSR:-18.14.5 |
| 430 | NS Item -Providing, fixing, testing and commissioning of non-return valve complete with nuts, bolts and washers. ) e) 50 mm dia DSR:- 18.14.2 |
| 431 | NS Item -Providing, installation, testing and commissioning of water curtain nozzle 15mm dia nickel chrome plated brass, BSPT, K-factor as per design consideration complete as required. |
| 432 | NS Item -Supply and Erection C` class heavy duty MS Pipe 65 mm dia Complete in all respect upto satisfaction of Engineer in Charge. |
| 433 | NS Item -MS PIPE (INTERNAL)- Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150mm dia |
| 434 | NS Item -Supply and Erection C` class heavy duty MS Pipe 32 mm dia Complete in all respect upto satisfaction of Engineer in Charge. |
| 435 | NS Item -MS PIPE - Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 50mm dia |
| 436 | NS Item -MS PIPE - Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 250mm dia (wall thickness 6.35mm) |
| 437 | NS Item -DSR-18.7 Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:18.7.1 25mm dia. |
| 438 | NS Item -Providing, fixing, testing and commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : UPRIGHT SPRINKLER TYPE DSR 18.21.1 Pendent Sprinkler |
| 439 | NS Item -Providing, fixing, testing and commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Horizontal side wall sprinkler |
| 440 | NS Item -Providing, fixing, testing and commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Upright Sprinkler |
| 441 | NS Item -Providing, fixing, testing and commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler |
| 442 | NS Item -Providing, Installation. Testing and Commissioning of NON Return Valve of following sizes Confirming to IS:5312 Complete with Rubber Gasket GI Bolts,Nuts,washers etc. size 200 mm dia |
| 443 | NS Item -Providing, Installation. Testing and Commissioning of NON Return Valve of following sizes Confirming to IS:5312 Complete with Rubber Gasket GI Bolts,Nuts,washers etc. size 65 mm dia |
| 444 | NS Item -Providing, Installation. Testing and Commissioning of NON Return Valve of following sizes Confirming to IS:5312 Complete with Rubber Gasket GI Bolts,Nuts,washers etc. size 150 mm dia |
| 445 | NS Item -Providing, Installation. Testing and Commissioning of NON Return Valve of following sizes Confirming to IS:5312 Complete with Rubber Gasket GI Bolts,Nuts,washers etc. size 80 mm dia |
| 446 | NS Item -Supplying, installation, testing and commissioning of electric driven pressurization pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) (B) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to lS: 1520.(C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS :325. (D) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered and with antivibration pads. 180 Ipm at 88 m Head |
| 447 | NS Item -Providing, fixing, testing and commissioning of 150 mm dia 6.35 mm thick flanged end basket 300mm height of Y-type strainer made from MS body with bottom and top removable flanges with nuts, bolts etc having filteration area at least 6 times the cross sectional area of the pipe. |
| 448 | NS Item -Providing and fixing of pressure switch in M.S. pipe line including connection etc. (specification as per DSR 2025 item no. 27.22) |
| 449 | NS Item -SITC of DMX Data Splitter: 1 x IN to 8 x OUTPUT DMX-512 Data Splitter Unit, suitable both for Dimmer and Intelligent Lights. Complete in all respect as per Directions of Engineer-in-Charge. |
| 450 | NS Item -Floor Boxes on stage area to accommodate video connectivity for podium and Confidence Monitors ( The Floor Boxes should have space to accommodate Fiber Transmitters or Receivers of size minimum dimensions as : (2.5 cm H x 22.2 cm W x 30 cm D). (Depth excludes connectors.).Complete in all respect as per Directions of Engineer-in-Charge. |
| 451 | NS Item -SITC of DMX Data required XLR connectors - 3-Pin cable type.Complete in all respect as per Directions of Engineer-in-Charge. |
| 452 | NS Item -SITC of HDMI Cables which provide interconnection for the transmission of HDMI digital video and audio signals over a copper cable assembly. It shall conform to the Premium High Speed HDMI Cable specification established by the HDMI organization. It should support resolutions up to 4096x2160 @ 60 Hz with 4:4:4 chroma sampling and 8-bit color depth and data rates up to 18.0 Gbps. It shall be made of 28 AWG copper wire and should have HDMI type A male connectors with gold-plated contacts. It should have Low bend radius of 0.80” (20.3 mm), Cable outer diameter of 0.22” (5.7 mm), Cable shall be 6 foot (1.8 m) in length, Cable shall provide protection from outside electrical interference and should comply with UL VW-1 and CSA FT-1 standards.Complete in all respect as per Directions of Engineer-in-Charge. |
| 453 | NS Item -SITC of Premium High Speed HDMI Cable as per specifications established by the HDMI organization. It should support resolutions up to 4096x2160 @ 60 Hz with 4:4:4 chroma sampling and 8-bit color depth. It shall support data rates up to 18.0 Gbps and shall meet the following cable construction requirements: Multi-Mode fiber and 28 AWG tinned copper conductors, HDMI type A male connectors with gold-plated contacts, Bend radius of 0.79` (20 mm), Cable outer diameter of 0.16` (4 mm), Max tensile strength of 100 N (10.2 kg, 22.5 lbs), Max. compression load resistance of 200 N (20.4 kg, 45 lbs), Cable shall be 35 foot (10.6 m) in length. Complete in all respect as per Directions of Engineer-in-Charge. |
| 454 | NS Item -SITC of Pearl-1024 DMX Lighting Desk : 120 Intelligent Fixtures plus 120 Dimmer Channels : 1024 Channels : Load and Save shows with USB : Theatrical Plotting and Playback functions : Shape Generator : 15 Playback Masters controlling 250 memories, chases or cue lists MIDI and Sound to Light triggers : VGA output : supplied with LED lamp.Complete in all respect as per Directions of Engineer-in-Charge. |
| 455 | NS Item -SITC of customized MCB Box for 36way with 100amp Isolator, Power indicator bus bar, volt meter,20amp MCB. Complete in all respect as per Directions of Engineer-in-Charge. |
| 456 | NS Item -Supply, Installation, Testing and Commissioning of LED profile 300w 36* voltage0-90-250v/50-60hz,working position: Any safe working position ,lamp: super high power LEDs: white 180w (cool white or warm white) average life time is over 5000h,CRI:)90,Lens angle :19*/26*/36*,optinal, LED display channel-2 ch,IP rate :IP 20 indor, speacial zoom funcation with manual adjustment, control mode: master /slave synchronization,DMX 512 control and automatic, run, construction: die-casting aluminum housing silver white and black. Complete in all respect as per Directions of Engineer-in-Charge. |
| 457 | NS Item -Gigabit Managed Network switch with PoE. Complete in all respect as per Directions of Engineer-in-Charge. |
| 458 | NS Item -S/E Blu ray Player. Complete in all respect as per Directions of Engineer-in-Charge. |
| 459 | NS Item -Operator Presentation PC in control room. OptiPlex Micro PC with Windows OS, HDMI Out, wireless Keyboard and Mouse, USB ports, 23` Monitor, MS office, Adobe and Antivirus. Complete in all respect as per Directions of Engineer-in-Charge. |
| 460 | NS Item -SITC of LED `COB` WASH LIGHT for CYCLORAMA: using 60 Nos.x 4w RGBW Hi-Power 3-in-1 LEDs : IP-65 rated : Power AC 240V / 50Hz 240W : Lamp Life: )50000 hours : Beam Angle: 60°: 0-100% electronic linear Dimmer, 1-10 times/sec strobe: DMX-512 signal, 6 DMX Channels : Al.die-cast housing : s/w Power and DMX data link cables: 4-leaf Barndoors and suitable clamp. Complete in all respect as per Directions of Engineer-in-Charge. |
| 461 | NS Item -SITC of LED PAR with Lamp : 240W warm white COB LED, (50,000 hrs), Voltage: AC90-260V 50/60Hz, Power consumption: 250W, Dimmer: 0100% electronic dimming, High speed strobe effect with 4 default strobe modes and speed adjustable, Hight light output with pure and even coverage, Light angle: 60°(8083A/ B/C/D), 120°(8083K/L), Control: DMX512, master-slave and sound activated or auto operation, Channels: 3/5/7(8083A), 5(8083D),3(8083B/C/L), 5/7/8(8083K)DMX channels USITT DMX-512, LED display, Low noise and efficient etc as required. Complete in all respect as per Directions of Engineer-in-Charge. |
| 462 | NS Item -Equipment rack - 42U 600mm Wide x 800 mm depth complete with PDU, tray fans and accessories as required.Complete in all respect as per Directions of Engineer-in-Charge. |
| 463 | NS Item -SITC of LED PAR, RGBW 185w: using 60 x 3w LEDs : smooth Dimming from 0-100% : Beam angle 15 degrees : DMX-512 signal, DMX Control : Al. die-cast housing: s/w suitable C-clamp. Complete in all respect as per Directions of Engineer-in-Charge. |
| 464 | HSR Item 25.1.5-Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 5. 125mm dia.HSR Rate(Rs.) 2385.00 Through Rate |
| 465 | HSR Item 25.1.6-Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 6. 100mm dia.HSR Rate(Rs.) 1896.00 Through Rate |
| 466 | HSR Item 25.1.7-Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 7. 80mm dia.HSR Rate(Rs.) 1589.00 Through Rate |
| 467 | HSR Item 25.1.9-Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 9. 50mm dia.HSR Rate(Rs.) 1028.00 Through Rate |
| 468 | HSR Item 25.1.10-Supplying, fixing, testing and commissioning of condenser water pipes / non insulated chilled water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. 10. 40mm dia.HSR Rate(Rs.) 821.00 Through Rate |
| 469 | HSR Item 25.7.1-Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 1. Thickness 0.63 mm sheetHSR Rate(Rs.) 812.00 Through Rate |
| 470 | HSR Item 25.7.2-Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 2. Thickness 0.80 mm sheetHSR Rate(Rs.) 972.00 Through Rate |
| 471 | HSR Item 25.7.3-Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 3. Thickness 1.00 mm sheetHSR Rate(Rs.) 1175.00 Through Rate |
| 472 | HSR Item 32.66.4-Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockloyd Rockwool (Non Combustible Grade) conforming to IS: 8183 and density 48 kg/ m3, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24gauge wire mesh, for top most ceiling of building and all complete as per engineer in charge 4. 75 mm thick Resin bonded Rock woolHSR Rate(Rs.) 497.00 Through Rate |
| 473 | HSR Item 23.23.7.1-MISCELLANEOUS 7.1. Supply anderection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 100 X 50 X 2 mmHSR Rate(Rs.) 203.00 Through Rate |
| 474 | VENTILATION PANEL-5(LOC: TERRACE) INCOMER1 No. 160A FP MCCB built in Thermal Magnetic based release (adjustable O/L,S/C) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader and Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended.METERING, INDICATOR AND RELAYs1 Set of R,Y,B phase indication lamps with 4Nos. Control MCB as per fault requirement for each Incomer.1 Set of ON/OFF/ Trip Indicating lamps for each incoming Multifunction meter should be of flush mounting 96 sq mm with alphanumeric LED display with all electrical measurementlike VAF, KW,KWH and PHASE WISE energy monitoring through communication RS 485 port available with meter. MFM should have a wide measurement range of 10mA to 6A and sampling rate of 128 samples per cycle. accuracy class of1.0 with meter AUX sup |
| 475 | 250Amps TP plus 50%N, 25kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows: a).Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and c). 201Amp and above Aluminium Bus-bars , current density of bus-bars shall not be less than 1Amps/sq.mm for Aluminium and 2Amps/sq.mm for copper cross sectional area of Bus Bar.Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up ( 1.8kV, Operating Temperature -40 deg `c` - plus 80 deg `C`, Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. = 40KA Per mode and In = 20kA per Mode. Make and Model: Argos-AG-230-40T2-E or eq.SPD with 4X63A SP HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used and length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O..OUTGOINGS10 Nos. 63A, 4P `C` Curve 10kA MCB with central overload trip mechanism and flag indication, with star delta starter as per type -2 coordination chart. |
| 476 | 2 Nos. 63A, 4P `C` Curve 10kA MCB with central overload trip mechanism and flag indication, with star delta starter as per -2 coordination chart 2 Nos. 63A, 4P `C` Curve 10kA MCB with central overload trip mechanism and flag indication, with star delta starter as per type -2 coordination chart. 3 Nos. 40A, 4P `C` Curve 10kA MCB with central overload trip mechanism and flag indication, with star delta starter as per type -2 coordination chart. (VENTILATION PANEL-4 (LOC:THIRD FL) |
| 477 | VENTILATION PANEL-3 (LOC: SECOND FL.) INCOMER1 No.200A FP MCCB built in Thermal Magnetic based release (adjustable O/L,S/C) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader and Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended.METERING, INDICATOR AND RELAYs1 Set of R,Y,B phase indication lamps with 4Nos. Control MCB as per fault requirement for each Incomer.1 Set of ON/OFF/ Trip Indicating lamps for each incoming Multifunction meter should be of flush mounting 96 sq mm with alphanumeric LED display with all electrical measurementlike VAF, KW,KWH and PHASE WISE energy monitoring through communication RS 485 port available with meter. MFM should have a wide measurement range of 10mA to 6A and sampling rate of 128 samples per cycle. accuracy class of1.0 with meter AUX supply 80 -_ 300v AC/DC in each incoming .TVSS AND BUS BARS300Amps TP plus 50%N, 25kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows: a).Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and c). 201Amp and above Aluminium Bus-bars , current density of bus-bars shall not be less than 1Amps/sq.mm for Aluminium and 2Amps/sq.mm for copper cross sectional area of Bus Bar.Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up ( 1.8kV, Operating Temperature -40 deg `c` - plus 80 deg `C`, Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. = 40KA Per mode and In = 20kA per Mode. Make and Model: Argos-AG-230-40T2-E or eq |
| 478 | SPD with 4X63A SP HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used and length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O..OUTGOINGS2 Nos. 100A FP MCCB built in Thermal Magnetic based release (adjustable O/L,S/C) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader and Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. with star delta starter as per type -2 coordination chart5 Nos. 63A, 4P `C` Curve 10kA MCB with central overload trip mechanism and flag indication, with star delta starter as per type -2 coordination chart.(VENTILATION PANEL-3 (LOC:SECOND FL) |
| 479 | VENTILATION PANEL-1(LOC: STILT FL.) INCOMER1 Nos.100A FP MCCB built in Thermal Magnetic based release (adjustable O/L,S/C) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader and Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended.METERING, INDICATOR AND RELAYs1 Set of R,Y,B phase indication lamps with 4Nos. Control MCB as per fault requirement for each Incomer.1 Set of ON/OFF/ Trip Indicating lamps for each incoming Multifunction meter should be of flush mounting 96 sq mm with alphanumeric LED display with all electrical measurementlike VAF, KW,KWH and PHASE WISE energy monitoring through communication RS 485 port available with meter. MFM should have a wide measurement range of 10mA to 6A and sampling rate of 128 samples per cycle. accuracy class of1.0 with meter AUX supply 80 -_ 300v AC/DC in each incoming .TVSS AND BUS BARS160Amps TP plus 50%N, 25kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows: a).Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and c). 201Amp and above Aluminium Bus-bars , current density of bus-bars shall not be less than 1Amps/sq.mm for Aluminium and 2Amps/sq.mm for copper cross sectional area of Bus Bar.Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up ( 1.8kV, Operating Temperature -40 deg `c` - plus 80 deg `C`, Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. = 40KA Per mode and In = 20kA per Mode. Make and Model: Argos-AG-230-40T2-E or eq. |
| 480 | SPD with 4X63A SP HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used and length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O..OUTGOINGS4 Nos. 63A, 4P `C` Curve 10kA MCB with central overload trip mechanism and flag indication1 No. 32A, 4P `C` Curve 10kA MCB with central overload trip mechanism and flag indication(VENTILATION PANEL-1 (LOC:STILET FLOOR) |
| 481 | HVAC and VENTILATION PANELHVAC and VENTILATION PANELDesign, Manufacture, Supplying, Transport to the site, Receiving, Unloading, Shifting to Sub-Station at various locations, handling, assembling, installation in correct aligned position, grouting with dash fasteners, GI nuts-bolts, testing and commissioning of the following bolted fabricated in compartmentalized (Form-3B construction) conform to IS: 8623/1993, Suitable for 415V, 3Phase, 4 Wire 50 Hz Ac supply, are housed in design from CRCA sheet steel of 2mm |
| 482 | hick for frame work and door covers, 3mm thick for gland plate, i/c cleaning and finishing complete, having extensible type bus bars of high conductivity, SMC bus bar supports, the maunfacturer shall be certified from CPRI for short circuit withstand capacity of min. 70kA for 1 Sec., fabrication shall be done in transportable sections and all front and back doors shall be hinged type and earth with frame, Entire panel shall have a common earth bar as specified below at the rear with 2 Nos. earth stud each side, bus bars and control wiring with suitable size of FRLS PVC insulated copper conductor cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-`The Bus bars will be Copper purity 99.9% / electrolytic grade E91 Aluminium duly sleeved with Helogen Free heat shrink coloured Insulated tube confirming to IEC 60684-3-247 Standard. The powder coating (70-80micron as per IS:13871 for indoor and 100-120 micron for outdoor), include one size higher terminal block in cable alley and interconnecting wires between bus bars and terminals via MCB.General Notes for site visit report for Panels/ Rising Main before submitting GA.The Manufacturer must visit the site before submitting GA drawings and submit a report consisting following: Possible height for Panel.Possible width for Panel |
| 483 | Back access will be possible or not. Cable entry will be from top or bottom.If entry from bottom whether MS. Stand is required or not. If the panel is wall mounted whether the wall is available or not.Path for movement of transportation of panel is possible or noti.e length, width etc. and the transportation sections shall be designed accordingly.Sufficient space available at front and back after door opening. Sufficient height available above panel for cable drop.Actual floor to floor height for rising mains.Also, refer to General Notes and Specifications for Panels/ Boards. |
| 484 | All Panels shall be considered Indoor type unless specified. The degree of protection for all indoor type panels shall be of IP:52 (`5` Indicates Dust Protected limited ingress of dust permitted. Will not interefere with operation of the equipment and `2` indicates protection against vertically falling drops of water with enclosure tilted upto 15 deg from vertical.) and all outdoor type panels shall be of IP:55 (`5` indicates Dust Protected limited ingress of dust permitted. Will not interefere with operation of the equipment and `5` indicates protection against jets of water)Provide thermostat controlled panel mounted heavy duty exhaust fan in each Vertical for all Main L.T Panel and Capacitor Panels. For all other panels a proper ventilation louvers shall be provided.Fully automtic control thermotate with strip heater shall be provide in each Bus-Bar alley and relay compartments to control the humidityContractor to submit manufacturer`s selection charts from approved list of make along with each component part number, Discrimination check certificate throughout the HV/MV network, insulation material and corners cover on bus-bars for approval.Contractor shall submit a set of handing over document consisting operational and maintenance manuals, installation guidelines of all product`s along with data sheets come with product, GA drawings with wiring diagram and product part code etc. shall be arranged and also place a laminated copy in a pocket inside the respective panel body.If mentioned fault rating of bus-bar and circuit breaker is unavailable consider next available upside ratingMimic diagram shall be provided on all panels. |
| 485 | used in a board / Panel.All live accessible parts shall be shrouded and all equipment shall be finger touch proof. SMC shrouds busbar supports shall be used. Padlocking facility shall be provided on all MCCB feeders doors and switch handles shall be locakble in OFF position.Equipments will be offered for following routine test only:- i). Check of Bill of Materials as per approved drawing, ii). Visual and Dimensional Check, iii) Functional Check, iv) HV/Megger test as per relevant IS, v) Busbar Density and Conductivity test, vi) Powder Coating thickness testThird Party test report as required by the consultant/ Client/ PMC from the one of the selected vendors from approved list of make for IP rating, IS/ IEC Compliance and CPRI Compliance tests etc.Minimum/Maximum Operating height- 300/1800 respectively Sealing Arrangement:- PE Foam Rubber/ Neoprene Rubber GasketBus Bars Supports - Non-Hygroscopic, Non Carbonising, Corrosinn Resistant, SMC Supports1 Set of connector (Phase plus Neutral) shall be provided in cable alley for all outgoing with interconnection wires between MCB and Connector.All electrical panel shall have two nos. common G.I. earth bar of 50X6mm for the panels having incomer fault of 50kA and rest all with 32X6mm or as specified conductor throughout of the panel lenght as per the fault kA rating of main Incomer, at the rear and for wall mounted panel with 2Nos. earth stud at top one at each side. |
| 486 | ottom base channel of MS section not less than 100mmx 50mmx50mmx 5mm thick for Main L.T. Panel and capacitor panels and 40mmx25mmx25mmx 5mm thickplates for all floor mounted MDB/MCC and SDBs etc.All outdoor use panel shall have bottom base stand of minimum 600mm or as mentioned below with M.S. angle iron 32mmx 32mmx6mm with fixing arrangement in RCC foundation.No derating shall be applicable upto ambient temp. 50ºC forall breakers and selected components.Each door other than bus bar section shall be 2 numbers wing knob cabinet cam lock with master key lock made of zinc alloy powder coated housing, handle and chrome plated cylinder and nut CL001.Minimum Air Clearances between bus bars: (Calculation with required supporting document shall be submitted by Panel manufecturer along with GA diagram).P-P=32mm, P-N=32mm,P-E=26mm and N-E=26mmPanel Power and control Wiring all FRLS PVC insulated min. conductor to be used as follows:AC voltage circuit-1.5 sqmm Red,Yellow,Blue andBlack Current circuit-1.5 sqmm Red,Yellow,Blue andBlackAC Control circuit-1.5 sqmm White for Phase and Black for NeutralDC Control circuit-2.5 sqmm GreyPower circuit- Red,Yellow,Blue for Phase andBlack for Neutral Phase-Neutral Terminology:TP: Three PhaseTPN: Three Phase and Neutral (Neutral shall be Half of Phase Capacity)TP plus 2N: Three Phase and Neutral (Neutral shall be 200% of Phase Capacity)4P: Three Phase and Neutral (Neutral shall be 100% of Phase Capacity)Labelling- Computerised Laminated Aluminium Name Plate with White letters on Blue/Black Background For Each Feeder and Panel Itself.The treatment of Panel Shall be Fully automatic 9-tank process for metal treatment which consists of Solvent/ Alkaline Degreasing, Water Rinsing, De- Rusting, Water Rinsing, Passivation, Phosphating, Water Rinsing, Activation |
| 487 | Only Micropocessor MCCB shall have Built-in µP based trip unit having protection functions LSIG. Variable current setting for L,S,I and G and variable time delay setting for L,S and G. Neutral O/L protection possible with 3P MCCB (with External Neutral CT) and 4P MCCB. Last Fault trip history on LCD screen of MCCB i.e Faulty phase, Type of Fault and interrupted current. shall be of double make double break roto active design with Ics = 100% Icu, with rotary handle and pad locking. arrangement,All meter at incomer level shall have minimum 128 sample per cycle,Acuuracy class 0.2s and compliance to IEC 62053-22 for active energy and IEC 62053-24 for reactive energy measurement, should be capable of Individual Harmonics measurement up to 63rd and compliance to relevant IEC standard IEC 61000-3. should be capable for 4 quadrant measurement , Including Demand and should be capable of generating onboard alarms for various critical conditions.Only Micropocessor MCCB shallVariable setting of LSIG type trip unitManufacturer should provide the Discrimination cordination study upto the bus fault level for all ACB/MCCB.All starter feedrs shall have MPCB as S/C protection device with built in O/L relay and Contactor (As per type 2 Co-Ordination chart of OEMs)s need to be selected as per Type-2 coordination cahrt of respective OEMS. |
| 488 | NS Item -`FIRE DAMPER and ACTUATORSSupply, installation, testing and commissioning of motorised combined smoke and fire damper (UL-555S rated). The quoted price shall include control panel alongwith fire resistant inter connecting wiring and also termination of Fire alarm control wiring.`Actuator |
| 489 | NS Item -`FIRE DAMPER and ACTUATORSSupply, installation, testing and commissioning of motorised combined smoke and fire damper (UL-555S rated). The quoted price shall include control panel alongwith fire resistant inter connecting wiring and also termination of Fire alarm control wiring.`Damper |
| 490 | NS Item -`LOUVERSSupply, Installation and testing of powder coated extruded aluminium Wall Louvres having frames and fixed blades with Wire Mesh screen of Aluminum/ Galvanized Steel, Mesh Size 20x20mm, Flanges drilled/rivetted as standard. with proper neoprene gasket.Louvres to be mounted on Brick/Block/Concrete Wall, all arrangements required for fixing, including cutting, drilling, fixing, Water Proofing etc to be considered in the Quote. RAL standards color to be matched with external wall shade or as approved by architect.` Gravity Louverwith Wiremesh |
| 491 | NS Item -`VOLUME CONTROL DAMPERSupplying, installing, testing and balancing of rectangular volume control damper made of 18 G GI casing 120 mm wide and 20 G GI sheet blade 100 mm wide, chrome plated spindles, self lubricating bushes blade linkage fully enclosed, handle operation with status indicator suitable for rectangular ducting connection and complete as per drawing.`Duct VCD |
| 492 | NS Item -`GRILLES and WIREMESHSupply, installation, testing, balancing and commissioning of Extruded Aluminium construction Grilles. The grilles will be powder coated in shade approved by Client and installed as per approved shop drawings and specifications. The grilles may be double or single louvered, adjustable or fixed as required by Client.`Grilles without VCD |
| 493 | NS Item -`AXIAL FLOW FANUnloading, shifting, installation, testing and commissioning of AXIAL FLOW FAN as per the specifications. The fans shall be AMCA certified for air performance and sound ratings and shall be selected for maximum efficiency. Fan shall be complete with back draft damper, bird screen and as per specifications.Class-F motors suitable for 415±10% volts, 50 cycles, 3 phase AC supply and fan-motor efficiency exceeding ASHRAE 90.1-2007 Criteria and static pressure shall be as per indicated. All the Emergency fans shall be activated in case of fire signal from fire alarm system.1. The bidder shall submit fan performance curves for all fans.2. The item should be all complete in line with relevant standards, technical specifications of the standards and direction of engineer incharge.3. All the normal operation Fans shall be Vane Axial Type4. The sound level not exceed 80 dB(A) at 3 m distance for Normal operation fans.`9000 CFM/30mmWg (Car Parking) |
| 494 | NS Item -`AXIAL FLOW FANUnloading, shifting, installation, testing and commissioning of AXIAL FLOW FAN as per the specifications. The fans shall be AMCA certified for air performance and sound ratings and shall be selected for maximum efficiency. Fan shall be complete with back draft damper, bird screen and as per specifications.Class-F motors suitable for 415±10% volts, 50 cycles, 3 phase AC supply and fan-motor efficiency exceeding ASHRAE 90.1-2007 Criteria and static pressure shall be as per indicated. All the Emergency fans shall be activated in case of fire signal from fire alarm system.1. The bidder shall submit fan performance curves for all fans.2. The item should be all complete in line with relevant standards, technical specifications of the standards and direction of engineer incharge.3. All the normal operation Fans shall be Vane Axial Type4. The sound level not exceed 80 dB(A) at 3 m distance for Normal operation fans.`16000 CFM/30mmWg (Lift Lobby Pressurisation) |
| 495 | NS Item -`AXIAL FLOW FANUnloading, shifting, installation, testing and commissioning of AXIAL FLOW FAN as per the specifications. The fans shall be AMCA certified for air performance and sound ratings and shall be selected for maximum efficiency. Fan shall be complete with back draft damper, bird screen and as per specifications.Class-F motors suitable for 415±10% volts, 50 cycles, 3 phase AC supply and fan-motor efficiency exceeding ASHRAE 90.1-2007 Criteria and static pressure shall be as per indicated. All the Emergency fans shall be activated in case of fire signal from fire alarm system.1. The bidder shall submit fan performance curves for all fans.2. The item should be all complete in line with relevant standards, technical specifications of the standards and direction of engineer incharge.3. All the normal operation Fans shall be Vane Axial Type4. The sound level not exceed 80 dB(A) at 3 m distance for Normal operation fans.`B) 7500 CFM/30mmWg (Liftwell Pressurisation) |
| 496 | NS Item -`AXIAL FLOW FANUnloading, shifting, installation, testing and commissioning of AXIAL FLOW FAN as per the specifications. The fans shall be AMCA certified for air performance and sound ratings and shall be selected for maximum efficiency. Fan shall be complete with back draft damper, bird screen and as per specifications.Class-F motors suitable for 415±10% volts, 50 cycles, 3 phase AC supply and fan-motor efficiency exceeding ASHRAE 90.1-2007 Criteria and static pressure shall be as per indicated. All the Emergency fans shall be activated in case of fire signal from fire alarm system.1. The bidder shall submit fan performance curves for all fans.2. The item should be all complete in line with relevant standards, technical specifications of the standards and direction of engineer incharge.3. All the normal operation Fans shall be Vane Axial Type4. The sound level not exceed 80 dB(A) at 3 m distance for Normal operation fans.`11000 CFM/30mmWg ( Staircase Pressurisation) |
| 497 | NS Item -`INLINE FANSSupply installtion and commissioning of corrosion resistant pressed galvanised sheet steel metal of suitable thickness , non stalling backward curve impeller, factory matched to the electrical motor of suitable rating single phase 230 Volt , 50 to 60 Hz, rotor type sealed for life ball bearing assemblies and class F , IP 44 protection protection with an internal automatic reset safety thermal overload protection device. The fan should include electrical termination , mounting with necessary galvanised dipped supports , flexible connections if necessary, including all accessories. Fan should be statically and dynamically balanced as per ISO 1940 standard. All the fans should have a provision of bird screen louvers fixing arrangement.All inline fans shall be AMCA certified and shall be provided with speed regulator.`500 CFM ESP at 30mmwg |
| 498 | NS Item -VENTILATION FANS`INLINE FANSSupply installtion and commissioning of corrosion resistant pressed galvanised sheet steel metal of suitable thickness , non stalling backward curve impeller, factory matched to the electrical motor of suitable rating single phase 230 Volt , 50 to 60 Hz, rotor type sealed for life ball bearing assemblies and class F , IP 44 protection protection with an internal automatic reset safety thermal overload protection device. The fan should include electrical termination , mounting with necessary galvanised dipped supports , flexible connections if necessary, including all accessories. Fan should be statically and dynamically balanced as per ISO 1940 standard. All the fans should have a provision of bird screen louvers fixing arrangement.All inline fans shall be AMCA certified and shall be provided with speed regulator.`1000 CFM ESP at 30mmwg |
| 499 | NS Item -`PRESSURE GAUGESupplying, installing, testing and commissioning of 100 mm dia. Dial Type Pressure Gauges (glycerine filled) with gun-metal valve, U Bend, pet cocks/ gate valves. Display range 0-6 bar(min) with insulation same as on pipe.` |
| 500 | NS Item -`FLOW SWITCHSupply, Installation, Testing and Commissioning of UL listed electrically operated flow indicating switch of following diameter with threaded connection with flexible full bore paddle and NO/NC contact terminals as specified complete with all accessories and necessary wiring.`200 mm dia |
| 501 | NS Item -`BALL VALVES without StrainerSupply, Installing, testing and commissioning of PN-16 pressure rating ball valve, bronze forged body, chrome plated bronze ball and control level etc. in position complete with insulationand cladding of same thickness as on pipe with all the necessary mounting accessories as required for complete installation. As per specification/drawings and as directed by Engineer In Charge.`32 mm dia |
| 502 | NS Item -`BALL VALVES with StrainerSupply, Installing, testing and commissioning of PN-16 pressure rating ball valve, bronze forged body, chrome plated bronze ball and control level etc. in position complete with insulationand cladding of same thickness as on pipe with all the necessary mounting accessories as required for complete installation. As per specification/drawings and as directed by Engineer In Charge.`32 mm dia |
| 503 | NS Item -`Y STRAINERSupply, Installation, Testing and Commissioning of PN-16 rating flanged end `Y` type strainer cast steel body and Stainless steel screen and bronze drain plug. The body shall be hot dip galvanized. Filter element shall be of non magnetic 20 gage SS sheet with 1 mm perforation. Cartridge having five different type of filters made out of SS 304 with different mesh sizes shall be provided.Price shall include the cost of Insulation, material and external treatment will be same as of pipe.`200 mm dia |
| 504 | NS Item -`NON RETURN VALVESupply, Installation, Testing and Commissioning of NON RETURN VALVE of CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation and cladding of same thickness as on pipe.`200 mm dia |
| 505 | NS Item -`BALANCING VALVES (MANUAL)Supply, Installation, Testing and commissioning of Manual Balancing valves having gun metal / cast iron body for 50 mm internal thread and for above 65 mm dia flange ends withPN-16, Globe Type BSP Threaded End Construction with insulation and cladding of same thickness as on pipe. The valve shall be complete with companion flanges, nuts, bolts, gaskets and probes for pressure measurement complete with pressure read out points etc. PN -16 pressure rating.`200 mm dia |
| 506 | NS Item -`PIBCV VALVES (MODULATING TYPE)Supply, Installation, Testing and Commissioning of following sizes of PIBCV Valve with modulating actuator with only Globe/Ball type construction (Cast Iron valve body) with insulationand cladding of same thickness as on pipe. Actuator should have IP 54 rating. control input signal 4-20 mA or 0-10 V, along with necessary wiring and flanges. Operating voltage for actuator shall be 24V AC. All necessary wiring, conduiting, termination etc. to complete the system in all respects shall be considered in qouted price. PN- 16 Rating.`40 mm dia or suitable for 14.4 USGPM |
| 507 | NS Item -`PIBCV VALVES (MODULATING TYPE)Supply, Installation, Testing and Commissioning of following sizes of PIBCV Valve with modulating actuator with only Globe/Ball type construction (Cast Iron valve body) with insulationand cladding of same thickness as on pipe. Actuator should have IP 54 rating. control input signal 4-20 mA or 0-10 V, along with necessary wiring and flanges. Operating voltage for actuator shall be 24V AC. All necessary wiring, conduiting, termination etc. to complete the system in all respects shall be considered in qouted price. PN- 16 Rating.`80 mm dia or suitable for 76.8 USGPM |
| 508 | NS Item -`BUTTERFLY VALVES (MANUAL)Supply, Installation, Testing and Commissioning of PN-16 rating butterfly valve with epoxy coated Cast Iron body with SS304 Disc, integrally moulded EPDM liner of replaceable type and nitrile rubber O-ring. Valve shall be flanged end wafer type long neck construction single stem design with centre lugs to ensure proper alignment of pipe flanges.Price shall include the cost of Insulation, material and external treatment will be same as of pipeNote: All butterfly valves shall be provided with locking devices. Valves above 150 mm dia shall be gear driven.` 40 mm dia |
| 509 | NS Item -`BUTTERFLY VALVES (MANUAL)Supply, Installation, Testing and Commissioning of PN-16 rating butterfly valve with epoxy coated Cast Iron body with SS304 Disc, integrally moulded EPDM liner of replaceable type and nitrile rubber O-ring. Valve shall be flanged end wafer type long neck construction single stem design with centre lugs to ensure proper alignment of pipe flanges.Price shall include the cost of Insulation, material and external treatment will be same as of pipeNote: All butterfly valves shall be provided with locking devices. Valves above 150 mm dia shall be gear driven.` 50 mm dia |
| 510 | NS Item -`BUTTERFLY VALVES (MANUAL)Supply, Installation, Testing and Commissioning of PN-16 rating butterfly valve with epoxy coated Cast Iron body with SS304 Disc, integrally moulded EPDM liner of replaceable type and nitrile rubber O-ring. Valve shall be flanged end wafer type long neck construction single stem design with centre lugs to ensure proper alignment of pipe flanges.Price shall include the cost of Insulation, material and external treatment will be same as of pipeNote: All butterfly valves shall be provided with locking devices. Valves above 150 mm dia shall be gear driven.` 80 mm dia |
| 511 | NS Item -`BUTTERFLY VALVES (MANUAL)Supply, Installation, Testing and Commissioning of PN-16 rating butterfly valve with epoxy coated Cast Iron body with SS304 Disc, integrally moulded EPDM liner of replaceable type and nitrile rubber O-ring. Valve shall be flanged end wafer type long neck construction single stem design with centre lugs to ensure proper alignment of pipe flanges.Price shall include the cost of Insulation, material and external treatment will be same as of pipeNote: All butterfly valves shall be provided with locking devices. Valves above 150 mm dia shall be gear driven.` 100 mm dia |
| 512 | NS Item -`CHILLED WATER PIPING INSULATION - EPS TF QUALITY Supplying, applying, testing and commissioning of fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m and of thermal conductivity 0.029 W/m-K @ 20 degC mean tmperature, after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 26G aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing of damage as per specifications and as required complete in all respect.` 40 mm dia - 50 mm |
| 513 | NS Item -`CHILLED WATER PIPING INSULATION - EPS TF QUALITYSupplying, applying, testing and commissioning of fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m and of thermal conductivity 0.029 W/m-K @ 20 degC mean tmperature, after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 26G aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing of damage as per specifications and as required complete in all respect.` 50 mm dia - 50 mm |
| 514 | NS Item -`CHILLED WATER PIPING INSULATION - EPS TF QUALITY Supplying, applying, testing and commissioning of fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m and of thermal conductivity 0.029 W/m-K @ 20 degC mean tmperature, after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 26G aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing of damage as per specifications and as required complete in all respect.` 80 mm dia - 50 mm |
| 515 | NS Item `CHILLED WATER PIPING INSULATION - EPSTF QUALITYSupplying, applying, testing and commissioning of fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m and of thermal conductivity 0.029 W/m-K @ 20 degC mean tmperature, after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 26G aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing of damage as per specifications and as required complete in all respect.` 125 mm dia - 50 mm |
| 516 | NS Item -`CHILLED WATER PIPING INSULATION - EPS TF QUALITYSupplying, applying, testing and commissioning of fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m and of thermal conductivity 0.029 W/m-K @ 20 degC mean tmperature, after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 26G aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing of damage as per specifications and as required complete in all respect.` 100 mm dia - 50 mm |
| 517 | NS Item -`CEILING SUSPENDED AIR HANDLING UNITSSupply, installation, testing and commissioning of Modular CS Floor mounted air handling units made of 46 plus 2mm thick PUF insulated panels (Thermal Break) extruded aluminum profiles with 0.8mm thick pre-coated GI Outer Sheet and 0.8mm thick Plain GI inner sheet comprising of mixing box with fresh air and return air dampers, coil section with 6 row chilled water coil, 18G SS304 drain pan with 13mm thickness nitrile rubber insulation, blower section with DIDW Forward curved fans, drive set with V- belts, Spring type vibration isolators, wire guard on Fan section access door, fire retardant canvass connection at fan outlet, IE-3 motor (TEFC type and suitable for VFD operation) and LED lamps for blower section, limit switch for the fan section access door with a view port and damper at the outlet of unit.Filter section shall include pre-filter, fine filter , inspection doors for all filter sections. Ports to measure differential pressure across all filters.`3500 CFM and 8 TR , 65mm of wg Total St. Pressure |
| 518 | NS Item -`HORIZONTAL FLOOR MOUNTED TFASupply, installation, testing and commissioning of Modular Double skin Horizontal Floor mounted air handling units made of 46 plus 2mm thick PUF insulated panels (Thermal Break) extruded aluminum profiles with 0.8mm thick pre-coated GI Outer Sheet and 0.8mm thick Plain GI inner sheet comprising of mixing box with fresh air and return air dampers, coil section with 8 row chilled water coil, 18G SS304 drain pan with 13mm thickness nitrile rubber insulation, blower section with DIDW Forward curved fans, drive set with V- belts, Spring type vibration isolators, wire guard on Fan section access door, fire retardant canvass connection at fan outlet, IE-3 motor (TEFC type and suitable for VFD operation) and LED lamps for blower section, limit switch for the fan section access door with a view port and damper at the outlet of unit. Filter section shall include pre-filter, fine filter (washable bag type), inspection doors for all filter sections. Ports to measure differential pressure across all filters.All dampers shall be low leakage aluminum aerofoil design and suitable for manual / motorised operation.Units exposed to open sky shall have weather proof canopy.` 5000 CFM and 35 TR , 80mm of wg Total St. Pressure |
| 519 | NS Item -`HORIZONTAL FLOOR MOUNTED AIR HANDLING UNITSSupply, installation, testing and commissioning of Modular Double skin Horizontal Floor mounted air handling units made of 46 plus 2mm thick PUF insulated panels (Thermal Break) extruded aluminum profiles with 0.8mm thick pre-coated GI Outer Sheet and 0.8mm thick Plain GI inner sheet comprising of mixing box with fresh air and return air dampers, coil section with 8 row chilled water coil, 18G SS304 drain pan with 13mm thickness nitrile rubber insulation, blower section with DIDW Forward curved fans, drive set with V- belts, Spring type vibration isolators, wire guard on Fan section access door, fire retardant canvass connection at fan outlet, IE-3 motor (TEFC type and suitable for VFD operation) and LED lamps for blower section, limit switch for the fan section access door with a view port and damper at the outlet of unit. Filter section shall include pre-filter, fine filter (washable bag type), inspection doors for all filter sections. Ports to measure differential pressure across all filters.All dampers shall be low leakage aluminum aerofoil design and suitable for manual / motorised operation.Units exposed to open sky shall have weather proof canopy.` 8000 CFM and 15 TR , 80mm of wg Total St. Pressure |
| 520 | NS Item -`AIR SEPARATOR :Supply, installation, testing and commissioning of a Air Separator of M.S construction as per specifications on the return water line located at the pump suction or a suitable location as suggested. The separator should be complete with high capacity air vent, service valve, butterfly valve, water inlet, flanges, drain valve etc. suitable for following connection size:Suitable for pipe size - 125 NB` |
| 521 | NS Item -`CLOSED EXPANSION TANK :Supply, Installing, Testing and commissioning of the following capacities Closed Expansion tank with full acceptance Factor and shall be ASME rated/ European standard (code no.97/23/EC) or as per IS: pre-charged bladder-type pressure vessels. The tank shall be designed to absorb the expansion forces of heating/cooling system water while maintaining proper system pressurization under varying operating conditions. The heavy duty bladder should contain system water thereby eliminating tank corrosion and water logging problems. The system should include PRV and Airvent also. And complete as per technical specification. Tank shall be selected for PN-16 rating.` |
| 522 | NS Item -`SECONDARY VARIABLE CHILLED WATER PUMPS (VFD)Supply, installation, testing and commissioning of variable speed PN16 rated Axial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal having motor mounted IP55 integrated VFD for sensorless/wireless systems. Pump mounted VFD must be capable to display dynamic frequency, amps, volts, flow and head of operating pump. Suction Guide and Triple Duty Valves to be provided by the pump manufacturer for the unit responsibility. Each pump shall comprise of following as required as per specifications.Centrifugal Vertical Inline Split Coupled Pump with efficiency80% minimumSuitable HP, TEFC squirrel cage induction motor with IE-3 type class `F` insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. 720 USGPM @ 65 Ft Head (2W plus 1S)Motor : 18.5kW or suitable` |
| 523 | NS Item -`PRIMARY CHILLED WATER PUMPS:Supply, installation, testing and commissioning of PN16 rated Axial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. The external flush line must be used for the purpose of heat dissipation from the mechanical seal. Suction Guide and Triple Duty Valves to be provided by the pump manufacturer for the unit responsibility. Pumps with performance characteristics as given below: Centrifugal Vertical Inline Split Coupled Pump with efficiency 70% minimumSuitable HP, TEFC squirrel cage induction motor with IE-3 type class `F` insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. 720 USGPM @ 65 Ft Head (2W plus 1S)` |
| 524 | IR COOLED WATER CHILLING MACHINE`Supplying, installation, testing and commissioning of AHRI Certified Air Cooled Screw Chilling Machine of minimum 300 TR actual cooling capacity, suitable for operation under the specified design conditions, complete with unit mounted Variable Frequency Drive (VFD), comprising semi-hermetic twin rotor type double screw compressors (2 Nos.), complete with automatic capacity control from 100% to 25%, forced feed lubrication system, oil separators, and all safety controls.The unit shall consist of air-cooled condenser, shell and tube flooded / falling film type evaporator fabricated out of MS shell with copper tubes, insulated with minimum 19 mm thick nitrile rubber insulation, mounted on a common heavy duty structural steel base frame, complete with anti-vibration spring isolators, suitable for outdoor installation, all as per specifications.The chiller shall be provided with high efficiency squirrel cage induction motor (Class ‘B’ insulation) suitable for operation on 400V ±10%, 3 Phase, 50 Hz ±3% AC supply, complete with necessary drive arrangement, starter, protections, and accessories.The system shall be complete with microprocessor based control panel having digital display for monitoring and diagnostics, with provision for BMS connectivity through MODBUS/BACnet protocol, including all internal wiring, interlocks, control cabling, and necessary accessories.The scope shall include complete supply and installation of all associated components such as refrigerant piping with fittings, valves, expansion devices and accessories, refrigerant line accessories including safety valves, liquid indicators and level controls, water flow switches, drain valves, air purge valves, suction line insulation, structural framework, anti-vibration mounting, and RCC foundation for the unit. |
| 525 | he chiller shall conform to the following operating parameters:Chilled Water Inlet Temperature: 12.2°C Chilled Water Outlet Temperature: 6.7°C Ambient Temperature: 45°CMinimum COP: 3.2 IPLV: = 0.64 kW/TR NPLV: = 0.70 kW/TRMaximum Power Consumption: 1.48 kW/TR Minimum Flow Rate: 725 USGPM Maximum Pressure Drop: 7 m headThe unit shall be BEE 5 Star rated and supplied with AHRI Certified Performance Sheet. At least one chiller shall be factory tested at 100%, 75%, 50% and 25% load conditions before dispatch.The rate shall include loading, unloading, lifting, shifting, installation, testing, commissioning and handing over complete system in all respects as per specifications and directions of Engineer-in-Charge.`Aircooled water chilling machine Capacity - 300 TR (2WORKING) |
| 526 | NS Item -GRILLES and WIREMESHSupply, installation, testing, balancing and commissioning of Extruded Aluminium construction Grilles. The grilles will be powder coated in shade approved by Client and installed as per approved shop drawings and specifications. The grilles may be double or single louvered, adjustable or fixed as required by Client.Grilles without VCD... |
| 527 | NS Item -GRILLES and WIREMESHSupply, installation, testing, balancing and commissioning of Extruded Aluminium construction Grilles. The grilles will be powder coated in shade approved by Client and installed as per approved shop drawings and specifications. The grilles may be double or single louvered, adjustable or fixed as required by Client.Grilles with VCD... |
| 528 | NS Item -`PIBCV VALVES (MODULATING TYPE)Supply, Installation, Testing and Commissioning of following sizes of PIBCV Valve with modulating actuator with only Globe/Ball type construction (Cast Iron valve body) with insulationand cladding of same thickness as on pipe. Actuator should have IP 54 rating. control input signal 4-20 mA or 0-10 V, along with necessary wiring and flanges. Operating voltage for actuator shall be 24V AC. All necessary wiring, conduiting, termination etc. to complete the system in all respects shall be considered in qouted price. PN- 16 Rating.`50 mm dia or suitable for 24.0 USGPM |
| 529 | NS Item -`PIBCV VALVES (MODULATING TYPE)Supply, Installation, Testing and Commissioning of following sizes of PIBCV Valve with modulating actuator with only Globe/Ball type construction (Cast Iron valve body) with insulationand cladding of same thickness as on pipe. Actuator should have IP 54 rating. control input signal 4-20 mA or 0-10 V, along with necessary wiring and flanges. Operating voltage for actuator shall be 24V AC. All necessary wiring, conduiting, termination etc. to complete the system in all respects shall be considered in qouted price. PN- 16 Rating.`100 mm dia or suitable for 76.8 USGPM |
| 530 | NS Item -`DUCT THERMAL INSULATIONSupply, installation, testing and commissioning of thermal insulation on ducts with approved sample of Insulation shall be Antimicrobial Fire Retardant Closed Cell Chemically XLPE/Nitrile Rubber foam insulation material with Aluminium Foil with thermal conductivity not exceeding 0.032 W/m°K at an average temperature of 25°C. Density of the material shall be 25-30 Kg/m3. The insulation material shall be fire rated for Class O as per BS-476 Part 6 with non-toxic smoke .The insulation material shall be anti-microbial as per ISO 22196. Quoted price shall be inclusive of OEM supplied adhesive, tapes as per specification.`19 mm thick - Internal supply and return air ducts |
| 531 | VENTILATION PANEL-4(LOC: THIRD FL.) INCOMER1 No.200A FP MCCB built in Thermal Magnetic based release (adjustable O/L,S/C) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader and Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended.METERING, INDICATOR AND RELAYs1 Set of R,Y,B phase indication lamps with 4Nos. Control MCB as per fault requirement for each Incomer.1 Set of ON/OFF/ Trip Indicating lamps for each incoming Multifunction meter should be of flush mounting 96 sq mm with alphanumeric LED display with all electrical measurementlike VAF, KW,KWH and PHASE WISE energy monitoring through communication RS 485 port available with meter. MFM should have a wide measurement range of 10mA to 6A and sampling rate of 128 samples per cycle. accuracy class of1.0 with meter AUX supply 80 -_ 300v AC/DC in each incoming .TVSS AND BUS BARS300Amps TP plus 50%N, 25kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows: a).Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and c). 201Amp and above Aluminium Bus-bars , current density of bus-bars shall not be less than 1Amps/sq.mm for Aluminium and 2Amps/sq.mm for copper cross sectional area of Bus Bar. |
| 532 | Each Bus Section with 1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up ( 1.8kV, Operating Temperature -40 deg `c` - plus 80 deg `C`, Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. = 40KA Per mode and In = 20kA per Mode. Make and Model: Argos-AG-230-40T2-E or eq.SPD with 4X63A SP HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used and length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O..OUTGOINGS2 Nos. 100A FP MCCB built in Thermal Magnetic based release (adjustable O/L,S/C) of fault breaking capacity 25KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader and Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. with star delta starter as per type -2 coordination chart2 Nos. 63A, 4P `C` Curve 10kA MCB with central overload trip mechanism and flag indication, with star delta starter as per type -2 coordination chart.3 Nos. 40A, 4P `C` Curve 10kA MCB with central overload trip mechanism and flag indication, with star delta starter as per type -2 coordination chart.(VENTILATION PANEL-4 (LOC:THIRD FL) |
| 533 | NS Item -Supply, Installation, Testing and Commissioning of Addressable 2-wire high-performance multi-sensor detector, combining photoelectric smoke and heat detection, fully electronically addressed detector with 360° LED light-pipe indicator clearly visible under ambient light. The detector shall feature automatic drift compensation an integral microprocessor and provision to connect remote indicator.The red LED shall flash during normal operation and remain continuously illuminated during alarm condition. Detector shall be supplied with base. Certification: EN54 certified ( LPCB approved) |
| 534 | NS Item -Supply, Installation, Testing and Commissioning of Addressable 2-wire point-type photoelectric smoke detector, fully electronically addressed detector with 360° LED light-pipe indicator with visibility suitable for ambient light. The detector shall feature automatic drift compensation an integral microprocessor and provision to connect remote indicator.The red LED shall flash during normal operation and remain continuously illuminated during alarm condition. Detector shall be supplied with base.Certification: EN54 certified ( LPCB approved) |
| 535 | NS Item -Supply, Installation, Testing and Commissioning of Addressable 2-Wire Red Manual Call Point. Call point shall be suitable for wall mounting (surface or flush) and provided with a resettable operating element/lever and back box. A red LED indicator shall flash during normal condition and remain continuously ON during alarm. Certification: EN54 certified ( LPCB approved) |
| 536 | NS Item -Supply, Installation, Testing and Commissioning of Addressable 2 Wire dual-functionality Input/Output module, On board LED for fault indication. Certification: EN54 certified ( LPCB approved) |
| 537 | NS Item -Supply, Installation, Testing and Commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005.Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make:- Autronica/ Notifire / Bosch /Simens- EN |
| 538 | NS Item -Supply, Installation, Testing and Commissioning of Remote Indicator of discreet, low-profile design, suitable for integration with any interior décor and compatible with intelligent addressable fire detectors. |
| 539 | NS Item -Supply, Installation, Testing and Commissioning of Addressable loop powered Wall mount Sounder with Strobe, adjustable volume levels and selectable flash patterns, Sound 73dB (A) @ 1 meter, flashing colour RED, LED strobe synchronization capability, beacon function can be independently disable when visible indication is not required. Certification: EN54 certified ( LPCB approved) |
| 540 | NS Item -Supply, Installation, Testing and Commissioning of Short Circuit Fault Isolator Module complete with all accessories. EN54 certified ( LPCB approved) |
| 541 | NS Item -Supply, Installation, Testing and Commissioning of 4-Loop Modular and Networkable Intelligent addressable Fire control comprising a 100% electronically addressable system. Colour Display of 7-inch touch-screen with 48 zone LED indicators. Each loop shall support up to 324 addressable devices in any combination. The panel shall be equipped with built-in cyber security features and an inbuilt surge protection card and all components should have LED on board for fault verification. Panel shall include an inbuilt battery chargercapable of supporting 24 hours of standby (idle) operation and 30 minutes in alarm condition. The system shall feature hot-swappable loop cards with fault indication LEDs on each loop card, dedicated sounder circuit card upgradable up to 6 output ports. Panel shall be capable of storing a minimum of 10,000 historical events. Peer to peer networking should be done via CAN, RS485 or TCP/IP. Certification: EN54 certified |
| 542 | NS Item -Supply, Installation, Testing and Commissioning of Addressable repeater panel with control functions including evacuate, mute, silence and reset. Colour Display of 7-inch touch-screen, 14 supervisory LEDs and support peer-to-peer networking via CAN or RS-485 or TCP-IP. Provides 24 hours standby and 30 minutes alarm backup, stores up to 10,000 events and provide 3-level password protection. Configuration upload/download shall be supported via USB interface.Certification: Certification: EN54 certified ( LPCB approved) |
| 543 | NS Item -Supplying, installation, testing and commissioning of fire fighter phone jack complete as required. |
| 544 | NS Item -Supplying, installation, testing and commissioning of fire fighter telephone handset complete as required. |
| 545 | NS Item -Supply, Installation, Testing and Commissioning of 16 Zone Fire Fighter Telephone panel with all accessories. |
| 546 | NS Item -Supplying and laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring and LSZH outer sheath complete as required. |
| 547 | NS Item -Supplying, installation, testing and commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required. |
| 548 | NS Item -Supply, Installation, Testing and Commissioning of of PC Client Intel i7 processor with clock speed- minimum 3.0GHz, RAM8 GB and Expandable. Window 10 or Window 2016 Server or Unix based Edition .Minimum 512 GB . LAN Interface 10/100/1000 Mbps Ethernet.).. Mouse Optical . USB port at front and Software of cameras. |
| 549 | NS Item -Supply, Installation, Testing and Commissioning of Single sided wall/ceiling mounted laser-etched LED Exit Signage with minimum 20 meters viewing distance, high-efficiency L80 LEDs with 50,000 hour life with power consumption less than 2 watts, directional arrow and logo on 6 mm thick transparent acrylic sheet ensuring uniform illumination, along with integrated glow-in-the-dark photoluminescent feature for enhanced visibility during complete power failure, ABS housing with inbuilt electronic driver circuit for step-down conversion from 230V AC to 6V/12V DC, built in Lithium-ion battery backup providing minimum 6 hours of emergency operation with degree of protection IP20 and impact resistance IK04, complete with all accessories and complying with EN54, NABL approval and BIS 10322 standards. |
| 550 | NS Item -Supply, Installation, Testing and comissioning of minimum 1000 Mtr. Range Siren generatorprovided at the roof of the building with separate power suppl, relay etc. with all accessories required to complete the job in all respect up to the entire satisfaction of engineer incharge. Make: National/Kheraj |
| 551 | NS Item -Supply, Installation, testing and commissioning of 20 zone System controller with built-in DVR, having priority facility. Music and Pre-recorded fire evac message. Controller can be extended up to 100 zones. |
| 552 | NS Item -Supply, Installation, testing and commissioning of Booster amplifier 500-Watt RMS output at 2/4 Ohms with external line converter, Line Voltage: 70 / 100V, Output level LED, 3-way tone control, 3 types of protection (AC Bi metal circuit breaker, short circuit and Over heating), required power supply 220-240 V AC 50 Hz, |
| 553 | NS Item -Supply, Installation, testing and commissioning of 4` 6W Ceiling Speaker with SPL at rated power/1W 90dB (1m and 1kHz). Frequency response of 125Hz – 16kHz (-10 dB with reference to 1kHz). The speaker should have tappings at 6W/3W/1.5W. |
| 554 | NS Item -Supply, Installation, testing and commissioning of 15W Wall Mounted Speaker, Drive: L-6`/H-2`, Rated Power: 15W/7.5W/3.75W, Sensitivity: 92dB, Frequency Response: 110Hz-15KHz, Line voltage: 70-100V, Material: HIPS(Plastic), |
| 555 | NS Item -Supply, Installation, testing and commissioning of 30W Column Speaker, Max Power -36W: Rated Power – 30W, Sound pressure level at 1W – 87 ± 5 dB: Effective frequency range – 200 Hz -15 KHz: Rated Voltage – 100V: Rated Impedance - 417 Ohm: 4 Way Connector: |
| 556 | NS Item -Supply, Installation, testing and commissioning of Call Station keypad with for PA system Announcement with goose neck microphone and with LCD display to announce all the zones or individual zones. |
| 557 | NS Item -Supply, Installation, Testing and comissioning of 2 core multistrand 1.5 sq mm annealed copper conductor Fire alarm and speaker cable in existing pipe/ channel I/C connection etc. |
| 558 | NS Item -Supply, Installation, Testing and comissioning of 18U Equipment Rack with provision for housing all control equipment with front and rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer- in - Charge of the work. |
| 559 | NS Item -Supply, Installation, Testing and comissioning of 2 KVA UPS cum Inverter with 1 hour Backup. |
| 560 | NS Item -Supply installation testing and commissioning of conventional beams detector (Range 100Mtrs) with adressing module fully integrated consisting of both transmitter and receiver including mounting base as required. The price should include of external power supply for operating. |
| 561 | HSR Item 23.7.6.2-PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply anderection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.HSR Rate(Rs.) 32.00 Through Rate |
| 562 | NS Item -Supply, installation, testing and commissioning of 15` (15` LF plus 1.7` HF) High Performance Passive Wall Loudspeaker with RMS power : 500 Watts or better, Maximum Power Handling : 2000 Watt or better, frequency response (±3dB) : 50Hz - 20 kHz or better, Sensitivity (1W/1m) 100 dB or better, Max SPL of 127 dB or better, Dispersion : 90 degree X 70 Degree or better, Speakon Connectivity, Construction : High Quality Plywood or better, CE Certification or more, etc complete required as per specifications. |
| 563 | NS Item -Supply, installation, testing and commissioning of 12` ultra high power Infra Subwoofer with min RMS : 1000W or better, Peak : 4000 W or better, Frequency Response ( plus/- 3 dB) : 33Hz to 120 Hz or better, Sensitivity : 94 dB or better and Peak SPL continuous : 124 dB or better, Nominal impedance of 8 ohms, Construction: Plywood CE Certification or more, etc complete required as per specifications |
| 564 | NS Item -Supply, installation, testing and commissioning of custom ceiling hanging arrangement for above speaker and subwoofer etc complete requried as per speciifcations. |
| 565 | NS Item -Supply, installation, testing and commissioning of 10` (10` LF plus 1.7` HF) High Performance Active Loudspeaker with in built DSP 2 mic /Line inputs and Line outputs,RMS power : 300 Watts or better, Maximum Power Handling : 1200 Watt or better, frequency response (±3dB) : 65Hz - 20 kHz or better, Sensitivity (1W/1m) 96 dB or better, Max SPL of 121 dB or better, Dispersion : 90 degree X 70 Degree or better, compatible for dante expansion , Construction : High Quality Plywood or better, CE Certification or more, etc complete required as per specifications. |
| 566 | NS Item -Supply, installation, testing and commissioning of 8` High Performance Passive Wall Loudspeaker with RMS power of 200 Watts or more, maximum power of handling of 800 Watt or more,frequency response (±3dB) 70 Hz up to 20 kHz or better, the sensitivity (1W/1m) 95 dB and Max SPL of 118 dB or better ,construction: Min 15mm high quality plywood, with OEM mounting bracket and CE Certification or more, etc complete required as per specifications. |
| 567 | NS Item -Supply, installation, testing and commissioning of Min Dual 6.5` LF with 1.5`` voice coil and HF with 1` Voice coil High Performance 2.5 Way Passive Wall Loudspeaker with Min RMS power : 250 Watts at 8 Ohmsor better, Maximum Power Handling : 100 Watt or better, frequency response (±3dB) : 69Hz - 20 kHz or better, Sensitivity (1W/1m) 95 dB or better, Max SPL of 119 dB or better, Dispersion HxV : 117 degree X 114 Degree or better, 2 X Speak-on Connectivity for cascading purposes, Construction : High Quality Plywood or better, OEM Mounting brackets to be supplied. It should also be possible for the speaker to be connected on 70/100V through an optional Transformer module. CE Certification or more, etc complete required as per specifications. |
| 568 | NS Item -Supply, installation, testing and commissioning of Quad Channel Class D Power amplifier with built in DSP, 4 x 750W @ 4 ohms or 4 x 380 W @ 8 Ohms or better or 2 x 1500 W @ 8 ohms bridge or better, Frequency Response (± 3 dB) : 20 Hz - 20 kHz, THD plus N (@1 KHz) : (0.05% or better, Signal/Noise )95 dB or better, Input Sensitivity : -19.5 dB to 27 dB or better, Cooling : Temperature Controlled Fan, Input Connecivity : XLR and 3 Pin Euro or better and Output Connectivity: Speakon and/or 2 pin Euro Terminal or better, CMRR : 70 dB or better, Damping Factor: (200 or better, RS232 control / RJ-45 control, Dante™/AES67 expansion port, Protection : DC Short Circuit, Over Heating, Over Load, Signal Limiting, Power Limiter, Access Protection through Password and USB - Key Protection etc. LCD Display with intuitive user interface, CE Certification or more, etc complete required as per specifications. |
| 569 | NS Item -Supply, installation, testing and commissioning of Quad Channel Class D Power amplifier with built in DSP, 4 x 1250W @ 4 ohms or 4 x 630 W @ 8 Ohms or better or 2 x 2500 W @ 8 ohms bridge or better, Frequency Response (± 3 dB) : 20 Hz - 20 kHz, THD plus N (@1 KHz) : (0.05% or better, Signal/Noise )95 dB or better, Input Sensitivity : -19.5 dB to 27 dB or better, Cooling : Temperature Controlled Fan, Input Connecivity : XLR and 3 Pin Euro or better and Output Connectivity: Speakon and/or 2 pin Euro Terminal or better, CMRR : 70 dB or better, Damping Factor: (200 or better, RS232 control / RJ-45 control, Dante™/AES67 expansion port, Protection : DC Short Circuit, Over Heating, Over Load, Signal Limiting, Power Limiter, Access Protection through Password and USB - Key Protection etc. LCD Display with intuitive user interface, CE Certification or more, etc complete required as per specifications. |
| 570 | NS Item -Supply, installation, testing and commissioning of Digital Mixer with built in Signal Processor with 20 Audio Inputs, Atleast 16 Mic/Line with Phantom power. 1 Stereo USB Playback.Atleast 12 Outputs with 8 Line Outputs, 1 TRS Headset ouput. Analog input channels with gain, noise gate, compressor, phase, 48V phantom power, pan, high-pass filter, 4-band EQ, 200ms delay, automatic mixing, and 4-level feedback suppression functions. Output channels with low-pass filter, 4-band EQ, 200ms delay, 2 x 31-band GEQ modules. 2 x echo modules and 1 x reverb module. 9 x motorized 100mm faders. 10.1` capacitive touch screen with a resolution of 1280x80, etc complete required as per specifications. |
| 571 | NS Item -Supply, installation, testing and commissioning of wireless gooseneck system which contains dual channel receiver and two no. wireless gooseneck transmitter with UHF frequency band, Power consumption:(7.2W, switching Band width: 30MHz, Modulation method: FM, Oscillation mode: PLL, Sensitivity:)60dB @ 25KHz, 6dBv, Maximum offset: ± 45KHzS/N: >105dB, T. H. D: < 0.7% @ 1KHz, Frequency response: 20Hz~20KHz ± 3dB, coverage area: 60mtr, Audio output interface: unbalanced 6.35mm × 1, Balanced XLR × 2 or more, transmitetr should have LCD/LED screen to show status, gooseneck receiver should have Display screen: 2.4-inch 320x240 IPS TFT with detachable microphone with unidirectional polar pattern, Working hours:10 hours or more, Frequency range: UHF, Working temperature: -9 -40?, Oscillation mode: PLL, Harmonic radiation: (-65dBm, Maximum offset: plus -45KHz, Rf power output: 15MW or more, units should have USB type-c connectivity for charging, every receiver has volume adjustment button, etc complete required as per specifications. |
| 572 | NS Item -Supply, installation, testing and commissioning of wireless handheld and lapel microphone set which contain 4 channel receiver and 3no. Wireless handheld microphone and 1no. Wireless lapel microphone, receiver frequency band: UHF, switching bandwidth: 30MHz, odulation method: FM, Oscillation mode: PLL, Sensitivity:)60dB @ 25KHz, 6dBv, Maximum offset: ± 45KHz, S/N: >105dB, T. H. D: < 0.1% @ 1KHz, Frequency response: 20Hz~20KHz ± 3dB, coverage area: 60mtr, Wireless handheld tranmiter polar pattern: cardioid, working hour: 10 or more, display: LCD/LED, Harmonic Radiation: (-65dBm, Max Deviation: plus -45KHz, RF power: 15mW or more, wireless lapel/headworn body pack tranmitter polar patter: cardioid/omni directional, working hour: 10 or more, display: LCD/LED, Harmonic Radiation: (-65dBm, Max Deviation: plus -45KHz, RF power: 15mW or more, etc complete required as per specifications. |
| 573 | NS Item -Supply, installation, testing and commissioning of 8 channel Antenna Amplifier (audio) with 2no. Active directional antenna with impoedance of 50O |
| 574 | NS Item -SITC of custom, cyclorama projection screen of 24 x 15ft dimensions. |
| 575 | NS Item -SITC of Display technology DLP 0.96” DMD chips, brightness 11,500 lumen or higher, contrast ratio 20,00,000:1 or more, lamp type DuraCore laser, lamp life 30,000 hours, resolution WUXGA (1920x1200), Rec.709 supported, native aspect ratio 16:10, compatible aspect ratios 16:9 and 16:10, keystone vertical ±20 and horizontal ±20, horizontal scan rate 15.375~135.0 KHz and vertical scan rate 23.98~120 Hz (120 Hz for 3D feature projector), throw ratio 1.22–1.53, throw distance 1.31–9.82 m, zoom 1.25x, motorised lens supported, F-stop (min and max) 2.00~2.30, lens shift vertical ±120% and horizontal ±30% (half height, half width), focal length18.2–22.6, screen size 50–500, installation orientation 360° degree/front/rear/ceiling-top and rear-top, full 3D feature support, IP rating IP6X, 24/7 operation supported, 360° operation supported, security features security bar and Kensington lock, network control Crestron, Extron, AMX, PJLink, Telnet, device management software, operating humidity 10–85% and operating temperature 5–40°C, input interfaces HDMI 2.0 in x2, DVI-D in x1, 3G-SDI in x1, 3D sync in x1, 12V trigger x1, wired remote x1, HDBaseT x1, output interfaces HDMI out x1, 3D sync out x1, USB A (5V/2A) x1, control interfaces RS-232 x1 and RJ-45 network x1,, certifications AMX, BIS, BSMI, CB, EMC, Crestron, KC, RCM, FCC, TUV IEC 62368-1, ISO. |
| 576 | NS Item -SITC of Zoom lens |
| 577 | NS Item -SITC of Camera with 1/2.5 inch high quality CMOS sensor. It should have 4K Resolution of. It should have 20X optical zoom lens with auto focusing technology. It should have Low Noise and High SNR with Advanced 2D/3D noise reduction technology. It should have HDMI, USB 3.0, LAN inputs. It should have support for H.264/H.265 video compression,s: support AAC, MP3. It should have Pan / Tilt Movement. |
| 578 | NS Item -SITC of floor stand for confidence monitor display. |
| 579 | NS Item -Supply, installation, testing and commissioning of wireless conference base with one HDMI input up to 4K30 and two HDMI outputs. Video Output 2×HDMI type A 19-pin female connector, Video Output Resolution HDMI Main: 3840x2160@60Hz, 3840x2160@30Hz 1920x1080@60Hz,1280x720@60Hz HDMI Sub: 1920x1080@60Hz,1280x720@60Hz Video Output Capabilities, HDMI Main: HDMI1.4/HDMI2.0 HDMI Sub: HDMI1.4, Video Output HDCP, HDMI Main: HDCP1.4/HDCP2.2 HDMI Sub: HDCP1.4 , VideoInput 1×HDMI type A 19-pin female connector, Video Input Resolution 3840x2160@30Hz, 1920x1080@60Hz, 1280x720@60Hz , Video Input Capability HDMI1.4, Video Input HDCP HDCP1.4, Analog Audio Output 1×3.5mm computer audio interface, LAN InterfaceRJ45 x2: 1000Mbps x2 USB Interface, USB3.0: typeA x2, typeC x1: USB2.0: typeA x4, typeC x1: Audio Input AirPlay, Miracast, Chromecast, Windows/MAC App, WMH, WMC, Wireless Data Rate Up to 1200Mbps, Video Play Frame Rate 20-60 FPS, Support USB cam/mic/speaker transmission over wifi. Support 2x camera connection and switching. Support USB devices switching between local USB-B and wireless laptops. Support display content sharing to remote participants over video conference. Provide 2x LAN ports for network isolation between staff and guests. |
| 580 | NS Item -Supply, Installtion,Testing and Commissioning of Digital Interactive Podium in Metallic Frame and Wooden Top with 21.5 inch Full HD (Electromagnetic plus Capacitive) Interactive Display with Electromagnetic Pen, Interactive display with full HD resolution of 1920x1080, Technology IPS LCD, Aspect ratio16:9, Brightness 250 cd/m2, Contrast ratio1000:1, Pen Type shall be Pressure sensitive and cordless. with Motorized Tilting of the Interactive Panel, with provision to install Gooseneck Microphone, Interactive panel, Keyboard Tray and space to store AV equipment, Top connectivity plate with HDMI, USB x 2 and Power socket for external Laptop connectivity. |
| 581 | NS Item -SITC of professional 4K 8x8 HDMI2.0 Matrix Switcher with 8 HDMI inputs, 8 HDMI outputs, and 8 SPDIF audio outputs, which is designed for switching four HDMI2.0 and HDCP2.2 compliant signals. It also provides powerful EDID management to ensure reliable AV distribution and routing. Input Signal 8 HDMI . Input Connector Female Type-A HDMI . Output Signal 8 HDMI: 8 SPDIF audio. Output Connector Female Type-A HDMI: 3.5mm mini jack. Control Signal 1 IR IN: 1 TCP/IP: 1 RS232. Control Connector 3.5mm mini jack: female RJ45: 3-pin pluggable terminal block. Video Signal HDMI2.0andHDCP2.2 . Audio Signal Dolby Digital, DTS, DTS-HD |
| 582 | NS Item -Supply, Installation , Testing and commissioning of Active wall-plate Supports HDMI signal up to 4K@60Hz 4:2:0 8bit.Supports HDMI 1.4 standard and HDCP 2.2 compliant. Ensures display of content-protected media and interoperability with other HDCP compliant devices.HDBaseT technology extend HDMI signal 4K up to 131ft/40m and 1080P up to 230ft/70m. 10.2Gbps bandwidth. Supports RS232 pass-through with HDBaseT connection. Supports IR pass-through to extend IR signal to control display device. 48V PoH (power over HDBaseT) allows powering from the compatible receiver at the display end. |
| 583 | NS Item -SITC of Control System with 3 USB: On USB 3.0 connectors, at least 1 Ethernet port for control, RAM - 16GB DDR4, Storage memory - 128GB, able to connect on its cloud or if in offline mode then connect on LAN and receive the program published from cloud or if in offline mode then from a PC connected in same LAN, gives remote control GUI options as well from cloud or from a PC connected in same LAN, Networking: 1 x Gigabit LAN Wi–Fi 802.11 ac/b/g/n dual band, it should have minimum 5 license each included for both iOS and Android application, Certification: CE, FCC, UL, BIS, etc. |
| 584 | NS Item -SITC of 8 inch IPS color screen Touch panel, minimum screen resolution 1280 X 720, brightness 350cd/m2, contrast ratio 1000:1, ±80° horizontal and vertical wide viewing angles, ambient light sensor, proximity sensor, inbuilt Wi–Fi 6, 802.11 a/b/g/n/ax/ax and Bluetooth 5.0, Ethernet : 10/100/1000 Mbps LAN, capacitive multi touch technology, multi–touch points and 2–finger gesture capabilities., System Memory: 4GB LPDDR4, Internal Storage Memory: 32GB eMMC, support video format H.264 / H.265,VC–1, MPEG–4, VP9/VP8, Support Image Codecs: JPEG, BMP, GIF, PNG, Should have front 5MP FF camera, Customized GUI using same OEM GUI Software, Power over Ethernet (PoE) 802.3af Certification: CE, FCC, UKCA, RoHs, WEEE. |
| 585 | NS Item -SITC of camera joystick controller for video switching, camera control, and graphics mixing with control Input/Output - VISCA RS-232C OUT Connector. |
| 586 | NS Item -SITC of camera mount complete in all respects. |
| 587 | NS Item -Supply Installation testing commissioning of Recording, Streaming and Webcasting Hardware simultaneously, multi-format sources with a total of up to 8 inputs. This includes 4 SDI inputs and 4 HDMI inputs, 2x HDMI Outputs and 1xSDI output. Supports two external audio inputs. The system should be capable to record upto any four inputs simultaneously in a single frame. It should have 5.5inch screen. Should have support onboard recording to USB flash drives, SD card and portable HDDs. |
| 588 | NS Item -SITC of HDMI to USB Capture devive with Full HD (1080p60) resolution through your system’s USB 3.0 port with an optional HDMI loop out that supports resolutions up to 4K @60Hz. an optional HDMI loop-out that supports resolutions up to 4K @60Hz. |
| 589 | NS Item -SITC of USB extender set USB 3.0 signals up to 70 m over twisted pair cabling. |
| 590 | NS Item -SITC of 10-11 inch Multi-Touch display (iPad) with IPS technology with Liquid Retina display, Resolution:2388x1668-pixel resolution at 264 pixels per inch (ppi), 600 nits brightness. Should be provided with docking station. |
| 591 | NS Item - SITC of Layer 2 PoE Switch should have total 28 Nos. Gigabit port including 24 Nos. of 10/100/1000 Mbps PoE Ports and 4 Nos. of dual personality (SFP/GbE) ports. PoE Budget should be 375 watt.The switch should be flexible enough to be managed through cloud and standalone mode. The cloud management should be free of cost The Switch should have Non-blocking wire speed switch fabric, should have Min. 56 Gbps Back plane or more and should have Min. 41 Mpps or more, IPv6 Support, 16K MAC address, CE-LVD,FCC, CE ,BSMI , RoHS Compliant,Operating temperature 0 DegC to 50 Deg C Should have Cluster Stacking to manage up to 24 switches by single IP address and should be having valid ISO 9001, ISO 14001, ISO 45001:2018 |
| 592 | NS Item -SITC of Wireless access point. |
| 593 | NS Item -SITC of custom Floor Box for stage with 4 power Complete in all respect. |
| 594 | NS Item -SITC of 3` High Speed HDMI with Ethernet cable. |
| 595 | NS Item -SITC of 6` High Speed HDMI with Ethernet cable. |
| 596 | NS Item -SITC of 2 core 14 AWG/2.5 Sq mm, Twisted, unshielded Speaker cable with stranded annealed bare copper conductors. |
| 597 | NS Item -SITC of 2 core 16 AWG/1.5 Sq mm, Twisted, unshielded Speaker cable with stranded annealed bare copper conductors. |
| 598 | NS Item -SITC of 4 pair shielded Category 6 cable |
| 599 | NS Item -SITC of 2 core Twisted, shielded balanced Audio and control cable with 22AWG or better 7 strand annealed bare copper conductors. |
| 600 | NS Item -SITC of various clamps, mounts, connectors, necessary hardware for commissioning of the system. |
| 601 | NS Item -SITC of 28 U Equipment Rack, Locakable front glass door, cooling facility, internal wiring, front glass door, heat dessipation fans, movement wheels, power distribution units and equipment shelves as required, fully welded construction for strength. Extra-wide rackrail for cable pass-throughs to facilitate front-to-rear cabling. |
| 602 | NS Item -`SITC of HDMI Transmitter and Reciver set, Supports 4K/UHD/60Hz/4:4:4Supports HDMI2.0 and HDCP2.2, and is backward compatible to the previous version.Maximum transmission distance is up to 40m for 4Kx2K, and 70m for 1080p. Supports CEC, IR and RS232 pass-through for long-distance control. Supports bi-directional PoC for simplified wiring. Supports HDR. Features DIP switcher for choosing RS232 mode: Control, Update A, Update B.` |
| 603 | NS Item -SITC of 55` Display panel, 550 nits, Smart Android, 24*7, 4K UHD, Airplay and Chromecast, 32 Gb, Display Resolution 3840 x 2160, Aspect Ratio 16:9, Contrast ratio1200:1, Dynamic contrast ratio 400,000:1 |
| 604 | NS Item -SITC of 43` Panel, 440 nits, Smart Android, 24*7, 4K UHD, Airplay and Chromecast, 16 Gb, Contrast ratio 1200:1, Dynamic contrast ratio 400,000:1, Response Time (ms)(*1) -10. IPS panel type |
| 605 | NS Item -Supplying, installation, testing and commissioning of automatic electromechanical boom barrier suitable road width 3-3 mtrs for intensive applications torque-450 mm, high speed with 3 second opening/closing time with MS Powder coated housing and aluminium boom with fork rest, IP 67 Protection etc. (for Gate -Entry/Exit). |
| 606 | NS Item -Supplying, installation, testing and commissioning of a set of Entry/Exit push buttons for manual open and closing of barriers etc. complete as required.(for Gate Entry/Exit). |
| 607 | NS Item -Supplying, installation, testing and commissioning of Photocell based safety device to avoid closing of the barrier when a Vehicle is crossing the barrier. (Anti Fall Protection). |
| 608 | NS Item -Supplying, installation, testing and commissioning of Loop detector for closing of the barrier when a Vehicle crosses the barrier. |
| 609 | NS Item -Supply, installation, testing and commissioning of automatic number Plate Reading System (ANPRS) tuned to the license plates i,e it should be able to automatically read and record a wide range of vehicle registration number plates alpha-numeric character, written in English. Also the frontal image view of the vehicle to be provided in the GUI to facilitate manual viewing of the license plate image.Lane Coverage Each camera system covers at least 1 lane having width of 3.5 meter or more. Detection Zone 3m to 10 m for ANPR data, IP66 rated,1-1/2.8” progressive scan RGB CMOS or better50 H with IR cut filter Colour: 0.15 Lux @ 30 IRE F1.3,1/66000 s to 2 s or better,H.264 in High and Base profile, MPEG4, MJPEG,Minimum 4 Streams in H.264, 2MP, 25 fps,Resolution Minimum 1920 x 1080,Certification for box camera UL, CE certified\. Lens : should be minimum 3M , IR corrected 1/ 2.8,internal memory of 64 MB SDRAM and 128 MB FLASHES.consumption should be less than 5W.System should provide vehicle count, class of vehicles (minimum 8 class when installed over the lane and 4 lasses when installed on the side for multilane. |
| 610 | NS Item -Supply, installation, testing and commissioning and Laying of 2 C X 1.5 Sq mm multi stranded twisted shielded FRLS Copper cable. |
| 611 | NS Item -Supply, installation, testing and commissioning of CAT 6 UTP cable 23 AWG LSZH as per ANSI/TIA 568 C.2and ISO/ IEC 11801–2nd Edition, ROHS Compliant, solid copper conductors, tested @250 Mhz, with HDPE insulation of individual conductor and over all Dia of 5.8mm for Connectivity of Hub room to End Point. as complete as required. |
| 612 | NS Item -upply, Installation, Testing and Commissioning of of PC Client Intel i7 processor with clock speed- minimum 3.0GHz, RAM8 GB and Expandable. Window 10 or Window 2016 Server or Unix based Edition .Minimum 512 GB . LAN Interface 10/100/1000 Mbps Ethernet.).. Mouse Optical . USB port at front and Software of cameras.1. Processor (CPU) Make: Intel Model: Core i7 (latest available generation at time of supply) Base Clock Speed: Minimum 3.0 GHzCores: Minimum 6 cores (preferably 8 or more) Threads: As per processor standard Cache: Minimum 12 MB Smart Cache2. Memory (RAM) Installed RAM: 8 GB DDR4 / DDR5 Expandability: Up to 16 GB / 32 GB (minimum 2 DIMM slots) RAM Speed: Minimum 2666 MHz or higher3. Storage Primary Storage:Minimum 512 GB SSD (Preferred)(or 512 GB HDD if SSD not specified, but SSD strongly recommended)Interface: SATA / NVMe (NVMe preferred for performance) Expandability: Provision for additional storage (HDD/SSD slot)4. Operating System Compatible OS Options:Windows 10 Professional (64-bit) OR Windows Server 2016 ORUnix/Linux-based OS (Ubuntu/CentOS or equivalent)OS License: Genuine and activated (if Windows supplied)5. Networking (LAN Interface) Ethernet Port:10/100/1000 Mbps (Gigabit LAN) RJ-45 Port: 1 x minimumSupport for standard TCP/IP networking6. Ports and Connectivity USB Ports:Minimum 4 USB portsAt least 2 USB ports on front panel Video Output:HDMI / DisplayPort / VGA (minimum one) Audio:Mic-in and Line-out / Combo jack Additional Ports: |
| 613 | Ethernet (RJ-45)Optional: USB 3.0 / USB-C7. Input Devices Keyboard:USB wired keyboard (standard layout) Mouse:Optical USB mouseMinimum 2 buttons plus scroll wheel8. GraphicsIntegrated Graphics (Intel UHD or better) Capable of Full HD display (1920×1080)9. Cabinet Type: Desktop /Cooling: Adequate ventilation with internal fans Build: OEM branded or industrial-grade10. Power SupplySMPS: Standard certified (minimum 80 plus efficiency preferred)Input Voltage: 220–240V AC, 50 Hz Surge protection recommended11. Software (Camera System Integration) Pre-installed software for:CCTV / IP Camera viewing Recording and playback functionality Network camera integration supportCompatibility with standard surveillance systems (ONVIF preferred) with Originmal window 11 professional and antivirus for 2 years validity.12. Display Size 24” LED Resolution: Full HD (1920×1080) Ports: HDMI/VGA14. Compliance and Standards CE / FCC / BIS certified Energy-efficient compliant15. Additional Requirements Preloaded drivers and utilitiesSystem fully assembled, tested, and commissioned All cables and accessories included |
| 614 | SITC of 6MP fixed bullet camera with 1/2.9 inch progressive scan CMOS image sensor or better, minimum resolution 3200 x 1800 @ 20/25 fps or better, video compression MJPEG, H.264, H.265, audio compression G.711, G.722.1, G.726, MP2L2, PCM, AAC-LC, MP2L2,environment noise filtering, minimum three compressed stream (individually configurable), multi-level user ID/password, simultaneous live view up to 6 channels, 1 RJ45 10M/100M self-adaptive Ethernet port, security features including password protection, complicated password, HTTPS encryption, IP address filter, HTTP/HTTPS, WSSE, TLS 1.1/1.2/1.3, security audit log, watermark, protocol support TCP/IP, UDP, Multicast, NTP, DDNS, SNMP, QoS, DHCP, IPv4/v6, DNS, HTTP, HTTPS, RSTP, SRTP/RTSPS, Bonjour, NAT, UPnP, ONVIF, SSH, SMTP, ARP, FTP/SFTP, lens type4 mm, built-in microphone support, 1 fixed regions of interest (ROI), image enhancement BLC, HLC, 3D DNR, signal-to-noise ratio = 52dB, wide dynamic range 120dB, image parameters switch supported, image settings including rotate mode, saturation, brightness, contrast, sharpness, gain, white balance adjustable by client software or web browser, MicroSD/MicroSDC/MicroSDXC card support up to 512GB, illumination colour 0.005 Lux (@F1.6, AGC ON), 0 Lux with light, IR up to 30 mtrs, white light 20 mtrs, supplementary light type IR and white light, 4 privacy masks, electronic shutter 1/3 s to 1/100,000 s with slow shutter support, ONVIF profiles S, T, G, M supported, day/night modes Day, Night, Auto, Schedule, operating temperature -30 °C to plus 60 °C, humidity 95% or less (non-condensing), IP67 housing, edge based video content analytics including line crossing detection, intrusion detection, motion detection (support alarm triggering by specified target types (human and vehicle), video tampering alarm, exception, linkage notify surveillance centre, send email, trigger capture, general function heartbeat, mirror, password reset via email, pixel counter, password protection, anti-banding, language English, Hindi, power sourc |
| 615 | SITC of 6MP fixed dome camera with 1/2.9 inch progressive scan CMOS image sensor or better, minimum resolution 3200 x 1800 @ 20 fps or better, video compression MJPEG, H.264, H.265, audio compression G.711, G.722.1, G.726, MP2L2, PCM, AAC-LC, MP2L2, environment noise filtering, minimum triple compressed stream (individually configurable), multi-level user ID/password, simultaneous live view up to 6 channels, 1 RJ45 10M/100M self-adaptive Ethernet port, security features including password protection, complicated password, HTTPS encryption, IP address filter, HTTP/HTTPS, WSSE, TLS 1.1/1.2/1.3, security audit log, watermark, protocol support TCP/IP, UDP, Multicast, NTP, DDNS, SNMP, QoS, DHCP, IPv4/v6, DNS, HTTP, HTTPS, RSTP, SRTP/RTSPS, Bonjour, NAT, UPnP, ONVIF, SSH,SMTP, ARP, FTP/SFTP, lens type 2.8 mm/4 mm, built-in microphone support, 1 fixed region of interest (ROI), image enhancement BLC, HLC, 3D DNR, signal-to-noise ratio = 52dB, wide dynamic range 120dB, image parameters switch supported, image settings including rotate mode, saturation, brightness, contrast, sharpness, gain, white balance adjustable by client software or web browser, MicroSD/MicroSDC/MicroSDXC card support up to 512GB, illumination colour 0.005 Lux (@F1.6, AGC ON), 0 Lux with light, IR up to 30 mtrs, white light 30 mtrs, supplementary light type IR and white light, 4 privacy masks, electronic shutter 1/3 s to 1/100,000 s with slow shutter support, ONVIF profiles S, T, G, M supported, day/night modes Day, Night, Auto, Schedule, flashing light supported, operating temperature -30°C to plus 60 °C, humidity 95% or less (non-condensing), IP67 housing, edge-based video content analytics including line crossing detection, intrusion detection, motion detection (support alarm triggering by specified target types (human and vehicle), video tampering alarm, exception, linkage notify surveillance centre, send email, trigger capture, general functions heartbeat, mirror, password reset via email, pixel counter, password protection, anti-banding, language English, Hindi, power source |
| 616 | SITC of NVR IP video input 128 channels up to 12 MP resolution supported, incoming bandwidth minimum 400 Mbps, outgoing bandwidth minimum 400 Mbps, recording resolution up to 12MP, video output interfaces 2 HDMI ports with at least one supporting 4K resolution and 1 VGA port supporting 1080p resolution, audio output 1-channel, two-way audio input 1-channel, compression technique H.264, H.265 or better, live view/playback resolution up to 12MP resolution, synchronous playback up to 16 channels, smart playback function supporting smart search for selected area in video and smart playback to improve playback efficiency, VCA supporting multiple video content analytics events if camera supports edge-based analytics, SATA interfaces 16 supporting hot-plug with up to 10TB for each HDD, e-SATA supported, RAID types RAID0, RAID1, RAID5, RAID6, RAID10, N plus 1hot spare system supported, network interfaces 2 RJ45 10M/100M/1000M self-adaptive Ethernet interfaces, serial ports RS-232, RS-485, keyboard, USB interface 4 USB connectors with at least two USB 3.0 supported, fan redundant dual ball bearing fan, alarm I/O 16/8, power supply 100 to 240 VAC with redundant power supply, working temperature -10°C to plus 50°C, working humidity 10 to 90%, certification CE/FCC/BIS. |
| 617 | NS Item -SITC of 10 TB Hard disk Make: WD/Seagate/Toshiba |
| 618 | NS Item -SITC of 8 Port PoE Switch:- Switch should have total 10 Nos. Gigabit port including 8 Nos. of 10/100/1000 Mbps Ethernet PoE Ports and 2 Nos. of dual personality (SFP/GbE) ports.PoE should be 130 Watt. The switch should be flexible enough to be managed through cloud and standalone mode. The cloud management should be free of cost., The Switch should have Non-blocking wire speed switch fabric, should have Min. 20 Gbps Back plane or more and should have Min. 15 Mpps or more and . 16K Mac address or more, CE-LVD,FCC, CE ,BSMI , RoHS Compliant, Operating temperature 0 DegC to 50 Deg C,IPv6 Support, Should have Cluster Stacking to manage up to 24 switches by single IP address and should be having valid ISO 9001, ISO 14001, ISO 45001:2018 |
| 619 | NS Item - SITC of Layer 2 PoE Switch should have total 28 Nos. Gigabit port including 24 Nos. of 10/100/1000 Mbps PoE Ports and 4 Nos. of dual personality (SFP/GbE) ports. PoE Budget should be 375 watt.The switch should be flexible enough to be managed through cloud and standalone mode. The cloud management should be free of cost The Switch should have Non-blocking wire speed switch fabric, should have Min. 56 Gbps Back plane or more and should have Min. 41 Mpps or more, IPv6 Support, 16K MAC address, CE-LVD,FCC, CE ,BSMI , RoHS Compliant,Operating temperature 0 DegC to 50 Deg C Should have Cluster Stacking to manage up to 24 switches by single IP address and should be having valid ISO 9001, ISO 14001, ISO 45001:2018 |
| 620 | NS Item -SITC of 12 Port fiber LIU, Fully loaded which have sufficient slots to accommodate 24/12 Duplex LC/SC Ports,Should have fiber management provision inside with splice tray and other accessories, Should be rack mountable 1U,Should have Splice holder for minimum 24 Fiber cores,Should be made of Cold Rolled Steel ,Material Should steel:1.5 mm with powder-coated. LIU should have rack mount with channel with uppersheet openable for fiber management. Make: RandM/ Siemon/ Systimax. |
| 621 | NS Item -SITC of 86 Inch UHD, Screen Resolution - 3840 x 2160 (UHD), Built in Android OS, 2Gb Ram and 16Gb storage, Brightness 450 cd/m2, Inputs: HDMI x 3, USB x 4, LAN and RS232 Panel Drive 100Hz, Video Output-1x HDMI2.0, Viewing Angle 178/178 degree, In built Content Scheduler, Inbuilt Wifi, In built Web Browser HTML-5, Auto Switch on failover, RTC, Bluetooth, Wireless screen mirroring for Windows and Android, Speaker output - 2 x 10W, Rated Power Consumption 328 W, Standby Power Consumption 0.5W, Power Supply AC 110V – 240V, Built In Solo Sign Edge Software,24x7, In-built Capability to run Digital Signage Software of Same OEM. Complete in all respect as per Directions of Engineer-in-Charge. |
| 622 | NS Item -SITC of 5 meter pole complete with foundation. |
| 623 | NS Item -SITC of 9U outdoor IPV5 rated rack with 2 side FAN with 3 socket PDU with 15 AMP DP for power surge safty.With pole mount accessories. Rack should be certified. |
| 624 | NS Item -SITC of 22U Equipment Rack with provision for housing all control equipment with front and rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work. |
| 625 | NS Item -SITC of Indoor Wall mount 9U rack 630D With Front Glass Door Lock and Key: with toughened glass: with 1U cable Manager: Fan: 6 socket PDU (550MM x 630MM) |
| 626 | NS Item -SITC of CAT 6 UTP Cable.Transmission frequency of 250 MHz (Minimum),cable Should be 4 pair and Cable should be jacket FR PVC Lbp 69% required with certification report |
| 627 | NS Item -SITC of 6 KVA Online UPS Overvoltage cut-off device (OVCD),Support for up to 42 AH external battery cabinets, Generator Compatible with Wide Input. Wide Input Voltage window (110 – 280Vac) for IndianEnvironmental Condition andfor Optimized BatteryPerformance. UPS would support SNMP Mnagaer and web browser On Line With 1 hour Backup. |
| 628 | NS Item -Supply, Installation, Testing and Commissioning of CAT 6 UTP Universal (both tool and toolless) information outlet (I/O) in accordance with ANSI TIA 568 C.2, IEC 60603-7-4 2nd Edition, ISO/IEC TR 11801-9901-2014, ROHSCompliant. The I/O should have minimum 750 mating cycle and 200 insertion cycle and UL approved,for Camera at user end. |
| 629 | NS Item -Supply, Installation, Testing and Commissioning of loaded 24 port CAT 6 UTP, Transparent shutter jack panel, 1U height, UL-94V-0, Black with cable support bar, clear label marks and earthing plug for CAT6 cable termination at rack end. |
| 630 | NS Item -Supply, Installation, Testing and Commissioning of CAT 6 UTP, LSZH Patch Cord as per ANSI/TIA/EIA 568C.2 and UL 94-V-0, ROHS Compliant, patch cord 1 Mtr for rack side switch to jack panel connectivity. |
| 631 | NS Item -Supply, Installation, Testing and Commissioning of CAT 6 UTP, LSZH Patch Cord as per ANSI/TIA/EIA 568C.2 and UL 94-V-0, ROHS Compliant, patch cord 2 Mtr for rack side switch to end user connectivity. |
| 632 | NS Item -Supply, Installation, Testing and Commissioning of 1, 2 and 4 port face plate, British Style with Shutter, 2 Plate system clear finish with transparent labelling, ABS-UL94-V2, ROHS Compliant, in accorandce with standards like ANSI/TIA-568-C.2, ISO/IEC 11801:2002 AMMD.2:2010, YD/T926.3-2009 and ISO/IEC 60603-7 white for I/O fixing at user side. |
| 633 | NS Item -SITC of 4 Mega Pixel Outdoor PTZ Camera - 1/2.8 inch or better Progressive Scan CMOS, Frame per Second - 25fps , Dynamic Range - 120 dB, Signal to Noise Ratio - 52 dB, Minimum Illumination - Color: 0.005 Lux at F1.6, B/W: 0 Lux with IR, IR Range - 150m or better, Lens - `Higher side of focal length should be greater than 130mm varifocal-lens or better, Motorized Varifocal and Focus,` Optical Zoom - 32x or better, Digital Zoom - 16x or better, Horizontal Angle of View - 60° to 3° or better, Iris Control - Yes, Back Light Compensation - Yes, Electronic Image Stabilization - Yes, Active Noise Filtering - Yes, Presets - 300, Patrols - 8, Pattern- 4, Pan and Tilt Speed - `Pan speed: configurable from 0.1° to 160°/s: preset speed: 240°/s, Tilt speed: configurable from 0.1° to 120°/s, preset speed 200°/s,` Vertical Tilt - -15° to 90° with auto flip, Pan Movement - 360°, Video Streams - Min.three individual configurable streams , Video Compression - H.265,H.264, Audio - 1 Input / 1 Output, Privacy Mask - 24 programmable polygon privacy masks, mask color or mosaic configurable, Streaming - `Main Stream should support at 4MP at 25fps, 2MP at 25fps, Second stream should support at 640 x 480 at 25fps , Third stream should support at 2MP at 25fps ,` Ethernet - RJ45 10M/100M self-adaptive Ethernet port, Auto Tracking - Yes, Supported Protocols - TCP/IP, NTP, SSL/TLS, HTTP, UDP, IPv4/IPv6,SNMP, DHCP,HTTPS , Local Storage - Built-in memory card slot, support micro SD/micro SDHC/micro SDXC card, up to 512 GB, Analytics - Motion detection,Video tampering alarm,Trip wire detection, Perimeter / Intrusion detection, Alarms - 1 Input / 1 Output, Power Supply - 36VDC/ 24VAC , Hi-PoE, Operating Temperature - -30 °C to 65 °C (-22 °F to 149 °F) Operating Humidity - ,90% or less (non-condensing), Environmental Protection - IP67, IK10, ONVIF Compliant-Yes, Regulatory Approvals - CE/FCC/RoHS/BIS |
| 634 | HSR Item 23.7.6.2-PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply anderection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.HSR Rate(Rs.) 32.00 Through Rate |
| 635 | HSR Item 23.7.6.3-PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.3. Supply anderection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 32 mm dia.HSR Rate(Rs.) 45.00 Through Rate |
| 636 | Supply, Installation, Testing and Commissioning of of PC Client Intel i7 processor with clock speed- minimum 3.0GHz, RAM8 GB and Expandable. Window 10 or Window 2016 Server or Unix based Edition .Minimum 512 GB . LAN Interface 10/100/1000 Mbps Ethernet.).. Mouse Optical . USB port at front and Software of cameras.1. Processor (CPU) Make: Intel Model: Core i7 (latest available generation at time of supply) Base Clock Speed: Minimum 3.0 GHzCores: Minimum 6 cores (preferably 8 or more) Threads: As per processor standard Cache: Minimum 12 MB Smart Cache2. Memory (RAM) Installed RAM: 8 GB DDR4 / DDR5 Expandability: Up to 16 GB / 32 GB (minimum 2 DIMM slots) RAM Speed: Minimum 2666 MHz or higher3. Storage Primary Storage:Minimum 512 GB SSD (Preferred)(or 512 GB HDD if SSD not specified, but SSD strongly recommended)Interface: SATA / NVMe (NVMe preferred for performance) Expandability: Provision for additional storage (HDD/SSD slot)4. Operating System Compatible OS Options:Windows 10 Professional (64-bit) OR Windows Server 2016 ORUnix/Linux-based OS (Ubuntu/CentOS or equivalent)OS License: Genuine and activated (if Windows supplied)5. Networking (LAN Interface) Ethernet Port:10/100/1000 Mbps (Gigabit LAN) RJ-45 Port: 1 x minimumSupport for standard TCP/IP networking6. Ports and Connectivity USB Ports:Minimum 4 USB portsAt least 2 USB ports on front panel Video Output:HDMI / DisplayPort / VGA (minimum one) Audio:Mic-in and Line-out / Combo jack Additional Ports:Ethernet (RJ-45) |
| 637 | Optional: USB 3.0 / USB-C7. Input Devices Keyboard:USB wired keyboard (standard layout) Mouse:Optical USB mouseMinimum 2 buttons plus scroll wheel8. GraphicsIntegrated Graphics (Intel UHD or better) Capable of Full HD display (1920×1080) |
| 638 | 9. Cabinet Type: Desktop /Cooling: Adequate ventilation with internal fans Build: OEM branded or industrial-grade10. Power SupplySMPS: Standard certified (minimum 80 plus efficiency preferred)Input Voltage: 220–240V AC, 50 Hz Surge protection recommended11. Software (Camera System Integration) Pre-installed software for:CCTV / IP Camera viewing Recording and playback functionality Network camera integration supportCompatibility with standard surveillance systems (ONVIF preferred) with Originmal window 11 professional and antivirus for 2 years validity.12. Display Size 24” LED Resolution: Full HD (1920×1080) Ports: HDMI/VGA14. Compliance and Standards CE / FCC / BIS certified Energy-efficient compliant15. Additional Requirements Preloaded drivers and utilitiesSystem fully assembled, tested, and commissioned All cables and accessories included |
| 639 | Supply, Installation, Testing and Commissioning (SITC) of 5-meter GI octagonal pole including:Pole supplyFoundation construction Erection and alignmentTesting and handover2. Pole Specifications Type: GI Octagonal PoleHeight: 5 meters above ground level (AGL) Material:Conforming to IS 2713 / IS 2062 Shape:Octagonal (as specified)2.1 DimensionsBottom Diameter: ~114 mm (typical, varies by design) Top Diameter: ~60 mm (typical)Thickness: Minimum 4 mm3. Surface TreatmentHot Dip Galvanized (HDG) as per IS 2629 / IS 4759 Galvanization Thickness: Minimum 70–80 microns4. Foundation WorkType: RCC Foundation (M20 grade concrete)4.1 Foundation Size (Typical) as per design of OEM4.2 MaterialsReinforcement: TMT steel bars (Fe500 grade) Concrete Mix: M20 (1:1.5:3)4.3 Foundation ComponentsAnchor bolts (if base plate type pole) Template for alignmentGrouting with non-shrink compound Proper curing (minimum 7 days)5. Mounting ArrangementBase Plate Type OR Direct Burial Type Base Plate Thickness: Minimum 10–12 mm Anchor Bolts: 4 Nos. (minimum), galvanized6. Earthing (if applicable) |
| 640 | 7. Cable ProvisionInternal/External cable routing provision Junction box at base (weatherproof, IP65) Cable entry with gland8. Accessories Foundation bolts and nutsBase plate cover (if required) Cable glands and lugsPole cap/top coverBrackets for mounting lights/cameras (if required)9. Installation and Erection Proper alignment using plumbVertical tolerance within permissible limits Tightening of anchor boltsBackfilling and compaction Stability check11. Safety and Standards Conformance to relevant IS standardsSafe working practices during installation Wind load consideration as per IS 875 |
| 641 | NS Item -SITC of 3 core 1.5sqmm Power cable.Material: Electrolytic Grade Annealed Copper Class: Class 2 (stranded) as per IS 8130 Conductor Size: 1.5 sq.mm per core Number of Cores: 3 (Phase, Neutral, Earth)IS 694 (for PVC insulated cables up to 1.1 kV |
| 642 | NS Item -SITC of 6 KVA Online UPS With full specification complete in all respect double conversion UPS INPUT - Acceptable Input Voltage 110VAC-275VAC -Phase Single phase with ground - Isolation NO -Input voltage range to take 50% load 110VAC~275VAC -Input voltage range to take 100% load 160VAC~275VAC -Inrush Current Limit 8*Irms - Input Power Factor =0.995 -Input Frequency Range 45-55Hz / 54-66Hz (extendable to 40~70HZ when load ( 60%) -Input protection upstream breaker -Generator Set 1.5 x UPS Rating Power OUTPUT -Power(VA) max 6000 -Power(W) max 6000-Power Factor 1.0 -Waveform Pure sine wave -Nominal voltage 208V/220V/230V/240V -Voltage Variation ± 1 % - Voltage distortion ( 1% THD@ linear load (5% @non-linear load Output Frequency -Synchronization range 45-55Hz / 54-66Hz (extendable to 40~70HZ when load ( 60%) -Slew rate 1 Hz/s - Battery mode (50/60±0.1) Hz Transfer Time -Inverter Mode ( -_ ) Battery Mode 0ms -Batttery Mode ( -_ ) Inverter Mode 0ms -Inverter Mode -_ ) bypass Mode 0ms Full Load Efficiency -Line mode with battery full charged 95% @ 230V output with typical load -ECO mode =98% Overload Capability-Line mode 100% |
| 643 | SITC of indoor type vacuum circuit breaker (VCB) of 3 panel Switchboard ( 1 incomer and 2 Outgoings) as per IEC 62271-1,100,200 with posibility of future extension at one side,capacity 11 KV, 800 Amp, 3 Phase, 3 wire, 50 Hz, having a rupturing capacity of 350 MVA at 11 KV , 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification, totally enclosed with extended Aluminium bus bar of 800 Amps for each phase, metal clad, Indoor extensible type , flush front, Horizontal isolation, Horizontal drawout type with Electrical and Mechanical interlock and automatic safety shutter gear including padlocking arrangement, isolation plugs, assambly of 3 vaccum interrupters , with each pole individually encapsulated by epoxy insulations to make it dust proof and self - aligning finger type isolating contacts, truck having integral racking with necessary interlocks (for insertion and removing of VCB), manual and automatic motor charged independent closing/ tripping spring , trip free operating mechanism with closing and tripping push buttons and mechanical breaker,interconnected with HT sleeve (PVC not accepted) Aluminiumbus bar800 Amps ,including all protection, indication, Operation, monitoring and control and accessories as per the specification.- BIL: 28KV (RMS) / 75KV (Peak) and Altiude less than 100 meters- VCB 800 Amps for Incomers and Outgoing. VI of VCB should be sealed for 30000 operation. VCB operationg mechanism should be of M2 duty for minimum 10000 mechanical operation. - Closing and tripping coil of VCB should be of continious rating to achive minimal failure. - Volt meter with Selector switch( only for Incomer feeder)- Trip circuit supervision relay (feature of numerical relay)- LR and TNC switch- indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc. - Spec heaters - Power Pack (230V AC- 110V DC) for all the feeder INCOMERa) 11 KV 800 Amps., 26.3 kA Electrical operated draw out type Vacuum circuit breaker complete with trip free spring charged closing mechanism, necessary auxiliary relays, control switches, emergency hand trip devices and mechanical ON / OFF indicator etc. - 1 Setb) |
| 644 | 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA (onlyfor Incomer feeder)- 1 Setc) Resin Cast type CT having Ratio: 200-100A/ 1-1 A, Core1: 5P20, 5 VA: Core 2: 0.5, 5 VA (forIncomer) 100-50A/ 1-1 A, Core1: 5P20, 5 VA: Core 2: 0.5, 5VA (for outgoing) -1 Set d) Dual scale Ammeter(0-100A) Digital Type with three way ON/OFF selector switch with CT`s for metering (of suitable range 100/5, CL-5P10, 5VA). - 1 Sete) Numerical relay (should be VCB manufacturer`s own make) having protections of 50,51, 50N,51N,TCS. - Ammeter with Selectorswitch - 1 Setf) Space heater to prevent absorption of moisture.g) Multifunction Meter of Acc Class 0.5, having facility to see KW, KVA, KVAR, PF, KWH, KVARH, KVAH, A,V etc.(Secure/LandT make) - 2 setsf) Space heater to prevent absorption of moisture.g) Multifunction Meter of Acc Class 0.5, having facility to see KW, KVA, KVAR, PF, KWH, KVARH, KVAH, A,V etc.(Secure/LandT make) - 2 setsBUSBAR11 KV, 800 Amp. With 11 kV heat shrinkable sleeved TP Aluminium Busbar of 26.3 KA for 3 Sec fault rating.Separate earth busbar of 50 x 6 mm GI shall be provided on the rear bottom of the panel.OUTGOING:a) 11 KV 800Amps, 26.3 kA Electrical operated draw out type Vacuum circuit circuit breaker complete with trip free spring charged closing mechanism, necessary auxiliary relays, control switches, emergency hand trip devices and mechanical ON / OFF indicator etc. - 2 Nos.b) Space heater to prevent absorption of moisture.c) Resin Cast type CT having Ratio : 100-50A/ 1-1 A, Core1: 5P20, 5 VA: Core 2: 0.5, 5 VA (for Incomer) 100-50A/ 1-1 A,Core1: 5P20, 5 VA: Core 2: 0.5, 5 VA (for outgoing) -1 Set |
| 645 | d) Dual scale Ammeter(0-100A) Digital Type with three way ON/OFF selector switch with CT`s for metering (of suitable range 100/5, CL-5P10, 5VA). - 1 Sete) Numerical relay (should be VCB manufacturer`s own make) having protections of 50,51, 50N,51N,TCS. - Ammeter with Selectorswitch - 1 Setf) Multifunction Meter of Acc Class 0.5, having facility to see KW, KVA, KVAR, PF, KWH, KVARH, KVAH, A,V etc.(Secure/LandT make) - 2 setsg) 3 C/O Aux. Realys for Transformer Protections- 2 Sets Alarm annunciator for all outgoing HT VCB with with ACK, rest, test push button for transformer faults and electrical faults Complete in all respect |
| 646 | PANELS ( MAIN LT PANEL- INDOOR TTA TYPE )Supply, Installation, Testing and Commissioning of wall / free standing floor mounting dust and vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet, required hardware 3 mm thick bakelite sheet provided all along the bus bar and cable tray separating switches compartment and supporting suitable channel duly painted by 2 coat zinc / red oxide primer followed by 2 coats of powder coating in grey or required shade after rising. the panel having PU / Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipments / switch wear. Transport acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The Panel will be complete with control wiring (Copper) and fuse protection. (Only outer area on all sides shall be measured).Aluminium Bus Bar 1600A Electrolite grade E91 having cross section 2X1X100X10 mm for Phase, 1x100x10 mm for Neutral and 1x50x10 mm for Earth. TTA TYPE MAIN ELECTRICAL PANEL AS PER IEC-61349 -1and2MAIN LT PANEL- INDOOR TTA TYPE (IEC 61439-1and2)INCOMER FEEDERACB FP EDO 1600AMPS. 50KA. MP BASED RELEASE WITH O/L, S/C and E/F PROTECTION UNDERVOLTAGE RELEASEAUXILIARY CONTACTOR 2NO plus 2NC TNC SWITCHMECHANICAL LOCK ON/OFF/TRIP INDICATION LAMP MCB SP 6A,10 KA C-CURVE |
| 647 | DIGITAL MULTIFUNCTION METER CL1.0 CL1.0 RED INDICATION LAMP RED LED TYPE, 240V ACYELLOW INDICATION LAMP YELLOW LED TYPE, 240V AC BLUE INDICATION LAMP BLUE LED TYPE, 240V ACCT`s 1600/5A CL-1 FOR METERING CT`s 1600/5A CL-1 FOR APFC CT SHORTING LINK NEUTRAL LINK63A. FP 10KA MCB C CURVE70KA TYPE-II SPD 3P plus N BUS COUPLERACB FP EDO 1600AMPS. 50KA. WITH O/L, S/C and E/F |
| 648 | PROTECTION MP BASED MTX1G UNDER VOLTAGE RELASEAUXILIARY CONTACTOR 2NO plus 2NC TNC SWITCHMECHANICAL LOCK ON/OFF/TRIP INDICATION LAMP MCB SP 6A,10 KA C-CURVE OUTGOING FEEDER SECTION-1ACB FP EDO 1000AMPS. 50KA. MP BASED RELEASE WITH O/L, S/C and E/F PROTECTIONTNC SWITCH ON/OFF/TRIP INDICATION LAMP MCB SP 6A,10 KA C-CURVEDIGITAL MULTI-FUNCTION METER CL1.0 CT`s 1000/5A CL-1 FOR METERINGCT SHORTING LINK NEUTRAL LINKACB FP EDO 800AMPS. 50KA. MP BASED RELEASE WITH O/L, S/C and E/F PROTECTIONTNC SWITCHON/OFF/TRIP INDICATION LAMP MCB SP 6A,10 KA C-CURVEDIGITAL MULTI-FUNCTION METER CL1.0 CT`s 800/5A CL-1 FOR METERINGCT SHORTING LINK NEUTRAL LINKACB FP EDO 1600AMPS. 50KA. MP BASED RELEASE WITH O/L, S/C and E/F PROTECTIONAUX CONTACT BLOCK ON/OFF INDICATION LAMP MCB SP 6A,10 KA C-CURVEDIGITAL MULTI-FUNCTION METER CL1.0 CT`s 1000/5A CL-1 FOR METERINGCT SHORTING LINK NEUTRAL LINKMCCB FP 630A. 50KA. MP BASED WITH O/L and S/C , PROTECTION SPREADER SET |
| 649 | EXTENDED ROTARY HANDLE AUX CONTACT BLOCK ON/OFF INDICATION LAMP MCB SP 6A,10 KA C-CURVEDIGITAL MULTI-FUNCTION METER CL1.0 CT`s 630/5A CL-1 FOR METERINGCT SHORTING LINK NEUTRAL LINKMCCB FP 400A. 50KA. MP BASED WITH O/L and S/C , PROTECTION SPREADER SET EXTENDED ROTARY HANDLE ON/OFF INDICATION LAMP MCB SP 6A,10 KA C-CURVE AUX CONTACT BLOCK DIGITAL MULTIFUNCTION METER CL1.0 CL1.0 CT`s 400/5A CL-1 FOR METERINGCT SHORTING LINK NEUTRAL LINKMCCB FP 200A. 50KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SETEXTENDED ROTARY HANDLE ON/OFF INDICATION LAMP MCB SP 6A,10 KA C-CURVE AUX CONTACT BLOCK DIGITAL MULTIFUNCTION METER CL1.0 CT`s 200/5A CL-1 CT SHORTING LINK NEUTRAL LINK |
| 650 | SPREADER SET EXTENDED ROTARY HANDLE ON/OFF INDICATION LAMP MCB SP 6A,10 KA C-CURVE AUX CONTACT BLOCK DIGITAL MULTIFUNCTION METER CL1.0 CT`s 100/5A CL-1 CT SHORTING LINK NEUTRAL LINK OUTGOING FEEDER SECTION-2 MCCB FP 250A. 50KA. TM BASED WITH O/L and S/C , PROTECTION. SPREADER SET EXTENDED ROTARY HANDLE ON/OFF INDICATION LAMP MCB SP 6A,10 KA C-CURVE AUX CONTACT BLOCK DIGITAL MULTIFUNCTION METER CL1.0 CT`s 250/5A CL-1 CT SHORTING LINK NEUTRAL LINK MCCB FP 630A. 50KA. MP BASED WITH O/L and S/C , PROTECTION SPREADER SET EXTENDED ROTARY HANDLE AUX CONTACT BLOCK ON/OFF INDICATION LAMP MCB SP 6A,10 KA C-CURVE DIGITAL MULTI-FUNCTION METER CL1.0 CT`s 630/5A CL-1 FOR METERING CT SHORTING LINK NEUTRAL LINK MCCB FP 100A. 50KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SET |
| 651 | EXTENDED ROTARY HANDLE ON/OFF INDICATION LAMP MCB SP 6A,10 KA C-CURVE AUX CONTACT BLOCKDIGITAL MULTIFUNCTION METER CL1.0 CT`s 100/5A CL-1CT SHORTING LINK NEUTRAL LINKDUMMY SPACE FOR MCCBNOBLE COMPONENTS ENCLOSURE and ACCESSORIESFABRICATION IN 2.0/1.6MM CRCA SHEET POWDER COATING IN SIEMENS GRAY SHADE, CABLE ENTRY WILL BE TOP and BOTTOM SUITABLE FOR CABLE ,LOCK, RUBBER GASKET, HARDWARE ETC.BUS BAR and HARDWARE1600A. TPN ALUMINIUM MAIN BUS BAR ,LOAD WISE SUB FEEDER BUS BAR COLOUR COATED HEAT SHRINK BUS BAR SLEAVE NUT-BOLT,WASHER ,HARDWARE ETC. WIRING and ACCESSORIESPOWER and CONTROL WIRING WILL BE (ISI 1100V) FLAME RETARDENT LOW SMOKE PVC SINGLE CORE COPPER WIRE,COPPER LUGGS, PVC SLEEVE, FERRULES, NUMBERS, HARDWARE and LABOUR ETC.Complete in all respect |
| 652 | PANELS (EMERGENCY PANAL)Supply, Installation, Testing and Commissioning of wall / free standing floor mounting dust and vermin proof |
| 653 | compartmentalized cubical panel made out of 2 mm thick CRCA sheet, required hardware 3 mm thick bakelite sheet provided all along the bus bar and cable tray separating switches compartment and supporting suitable channel duly painted by 2 coat zinc / red oxide primer followed by 2 coats of powder coating in grey or required shade after rising. the panel having PU / Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipments / switch wear. Transport acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The Panel will be complete with control wiring (Copper) and fuse protection. (Only outer area on all sides shall be measured).Aluminium Bus Bar 800A Electrolite grade E91 having cross section 1X1X80X10 mm for Phase, 1x40x10 mm for Neutral and 1x50x10 mm for Earth.. TTA TYPE MAIN ELECTRICAL PANEL AS PER IEC-61349 -1and2EMERGENCY PANEL- INDOOR TTA TYPE (IEC 61439-1and2)INCOMER FEEDER FROM MLT PANELACB FP EDO 1600AMPS. 50KA. MP BASED RELEASE WITH O/L, S/C and E/F PROTECTION UNDERVOLTAGE RELEASEAUXILIARY CONTACTOR 2NO plus 2NC TNC SWITCHMECHANICAL LOCK ON/OFF/TRIP INDICATION LAMP MCB SP 6A,10 KA C-CURVE |
| 654 | DIGITAL MULTIFUNCTION METER CL1.0 CL1.0 RED INDICATION LAMP RED LED TYPE, 240V ACYELLOW INDICATION LAMP YELLOW LED TYPE, 240V AC BLUE INDICATION LAMP BLUE LED TYPE, 240V ACCT`s 1600/5A CL-1 FOR METERING CT SHORTING LINKNEUTRAL LINK 63A. FP 10KA MCB C CURVE 70KA TYPE-II SPD 3P plus N INCOMER FEEDER FOR DG SET1and2ACB FP EDO 800AMPS. 50KA. MP BASED RELEASE WITH O/L, S/C and E/F PROTECTION UNDERVOLTAGE RELEASE AUXILIARY CONTACTOR 2NO plus 2NC TNC SWITCHMECHANICAL LOCK ON/OFF/TRIP INDICATION LAMP MCB SP 6A,10 KA C-CURVE DIGITAL MULTIFUNCTION METER CL1.0 CL1.0 RED INDICATION LAMP RED LED TYPE, 240V ACYELLOW INDICATION LAMP YELLOW LED TYPE, 240V AC BLUE INDICATION LAMP BLUE LED TYPE, 240V ACCT`s 800/5A CL-1 FOR METERING CT SHORTING LINKNEUTRAL LINK BUS COUPLER ACB FP EDO 1250AMPS. 50KA. MP BASED RELEASE WITH O/L, S/C and E/F PROTECTIONUNDER VOLTAGE RELASE AUXILIARY CONTACTOR 2NO plus 2NC TNC SWITCH MECHANICAL LOCK ON/OFF/TRIP INDICATION LAMP MCB SP 6A,10 KA C-CURVE OUTGOING FEEDER SECTION-1 MCCB FP 400A. 50KA. MP BASED WITH O/L and S/C |
| 655 | PROTECTION SPREADER SET EXTENDED ROTARY HANDLE MCB SP 6A,10 KA C-CURVE DIGITAL MULTIFUNCTION METER CL1.0 CL1.0 CT`s 400/5A CL-1 FOR METERING CT SHORTING LINK NEUTRAL LINK MCCB FP 250A. 50KA. TM BASED WITH O/L and S/C , PROTECTION. SPREADER SET EXTENDED ROTARY HANDLE MCB SP 6A,10 KA C-CURVE DIGITAL MULTIFUNCTION METER CL1.0 CT`s 250/5A CL-1CT SHORTING LINK NEUTRAL LINK MCCB FP 200A. 50KA. TM BASED WITH O/L and S/C , PROTECTION. SPREADER SETEXTENDED ROTARY HANDLE ON/OFF INDICATION LAMP MCB SP 6A,10 KA C-CURVE AUX CONTACT BLOCK DIGITAL MULTIFUNCTION METER CL1.0 CT`s 200/5A CL-1CT SHORTING LINK NEUTRAL LINK MCCB FP 100A. 50KA. TM BASED WITH O/L and S/C , PROTECTION. SPREADER SETEXTENDED ROTARY HANDLE MCB SP 6A,10 KA C-CURVEDIGITAL MULTIFUNCTION METER CL1.0 CT`s 100/5A CL-1CT SHORTING LINK NEUTRAL LINK MCCB FP 63A. 50KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SET |
| 656 | EXTENDED ROTARY HANDLE MCB SP 6A,10 KA C-CURVEDIGITAL MULTIFUNCTION METER CL1.0 CL1.0 CT`s 400/5A CL-1 FOR METERING CT SHORTING LINK NEUTRAL LINKMCCB FP 100A. 50KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SET EXTENDED ROTARY HANDLE MCB SP 6A,10 KA C-CURVE DIGITAL MULTIFUNCTION METER CL1.0 CT`s 100/5A CL-1 CT SHORTING LINK NEUTRAL LINKMCCB FP 63A. 50KA. TM BASED WITH O/L and S/C , PROTECTION. SPREADER SET EXTENDED ROTARY HANDLE MCB SP 6A,10 KA C-CURVE |
| 657 | DIGITAL MULTIFUNCTION METER CL1.0 CT`s 60/5A CL-1CT SHORTING LINK NEUTRAL LINK MCCB FP 160A. 50KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SET EXTENDED ROTARY HANDLE MCB SP 6A,10 KA C-CURVE DIGITAL MULTIFUNCTION METER CL1.0 CT`s 160/5A CL-1 CT SHORTING LINK NEUTRAL LINK MCCB FP 250A. 50KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SET EXTENDED ROTARY HANDLE ON/OFF INDICATION LAMP MCB SP 6A,10 KA C-CURVE AUX CONTACT BLOCK DIGITAL MULTIFUNCTION METER CL1.0 CT`s 250/5A CL-1 CT SHORTING LINK NEUTRAL LINK MCCB FP 200A. 50KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SET EXTENDED ROTARY HANDLE ON/OFF INDICATION LAMP MCB SP 6A,10 KA C-CURVE AUX CONTACT BLOCK DIGITAL MULTIFUNCTION METER CL1.0 CT`s 200/5A CL-1 CT SHORTING LINK NEUTRAL LINK NOBLE COMPONENTS AMF LOGIC AMF LOGIC REQUIRED FOR SEB SUPPLY and DG SUPPLIES ENCLOSURE and ACCESSORIES FABRICATION IN 2.0/1.6MM CRCA SHEET POWDER COATING IN SIEMENS GRAY SHADE, CABLE ENTRY WILL BE TOP and BOTTOM SUITABLE FOR CABLE ,LOCK, RUBBER GASKET, HARDWARE ETC. |
| 658 | BUS BAR and HARDWARE1500A. FP ALUMINIUM MAIN BUS BAR ,LOAD WISE SUB FEEDER BUS BAR COLOUR COATED HEAT SHRINK BUS BAR SLEAVE NUT-BOLT,WASHER ,HARDWARE ETC. WIRING and ACCESSORIESPOWER and CONTROL WIRING WILL BE (ISI 1100V) FLAME RETARDENT LOW SMOKE PVC SINGLE CORE COPPER WIRE,COPPER LUGGS, PVC SLEEVE, FERRULES, NUMBERS, HARDWARE and LABOUR ETC.Complete in all respect |
| 659 | CAPACITOR PANEL 350KVARSupply, installation, testing and commissioning of powder coated of Siemens grey of approved colour compartmentlised cubicle MV Panel fabricated out of 14/16 SWG thick CRCA sheet steel suitable for operation on 415 Volts, 50Hz, 3 Phase 4 wire AC supply . The panel shalll be indoor free standing, floor mounting, dust and vermin proof type, adeqate sizecable alley with front operated rotary handles for MCCB`s complete with gland plates, lifting hooks, ventillating louvers |
| 660 | busbars, Inter connections, earthing, labelling electrical interlocking as per specification and drawings, suitable for termination of cables as per single line diagram including. supply and fixing of following switchgear and accessories complete as required. 630A Electrolite grade E91 having cross section 1X80X10 mm for Phase, 1x40x10 mm for Neutral .The Panel should be extendable type. CAPACITOR PANEL 340KVAR- INDOOR TTA TYPE INCOMER FEEDERMCCB FP 630A. 36KA. MP BASED WITH O/L and S/C , PROTECTION SPREADER SET EXTENDED ROTARY HANDLERED INDICATION LAMP RED LED TYPE, 240V AC YELLOW INDICATION LAMP YELLOW LED TYPE, 240V AC BLUE INDICATION LAMP BLUE LED TYPE, 240V ACMCB SP 6A,10 KA C-CURVE 12 STEP APFC RELAY EXHAUST FAN WITH FILTER NEUTRAL LINK OUTGOING FEEDERCAPACITOR BANK 50 KVAR =4NO. MCCB TP 125A. 25KA. TM BASED WITH O/L and S/C PROTECTION ROM and Spreader Links SPREADER LINK CAPACITOR DUTY CONTACTOR 50KVAR SPREADER LINK FOR CONTACTOR CONTROL MCB 6A.ON / OFF INDICATOR ON /OFF PUSH BUTTON. AUTO MANUAL SWITCH. |
| 661 | SIDE MOUNTING ADD-ON AUXILIARY CONTACT BLOCK LTCCH 440V AC CAPACITOR CAPACITOR BANK 25 KVAR =5NO.MCCB TP 63A. 25KA. TM BASED WITH O/L and S/C PROTECTION CAPACITOR DUTY CONTACTOR 25KVAR SPREADER LINK FOR CONTACTOR CONTROL MCB 6A.ON / OFF INDICATOR ON /OFF PUSH BUTTON. AUTO MANUAL SWITCH. SIDE MOUNTING ADD-ON AUXILIARY CONTACT BLOCK LTCCH 440VAC CAPACITOR CAPACITOR BANK 10 KVAR = 1NO. MCCB TP 32A. 25KA. TM BASED WITH O/L and S/CPROTECTION ROM and Spreader Links CAPACITOR DUTY CONTACTOR 10KVAR CONTROL MCB 6A. ON / OFF INDICATOR ON /OFF PUSH BUTTON. AUTO MANUAL SWITCH.SIDE MOUNTING ADD-ON AUXILIARY CONTACT BLOCK LTCCH 440V AC CAPACITOR CAPACITOR BANK 5 KVAR = 1NO.MCCB TP 20A. 25KA. TM BASED WITH O/L and S/CPROTECTION ROM and Spreader Links CAPACITOR DUTY CONTACTOR 5KVAR CONTROL MCB 6A. ON / OFF INDICATOR ON /OFF PUSH BUTTON. AUTO MANUAL SWITCH.SIDE MOUNTING ADD-ON AUXILIARY CONTACT BLOCK LTCCH 440V AC CAPACITOR NOBLE COMPONENTS |
| 662 | ENCLOSURE and ACCESSORIESFABRICATION IN 2.0/1.6MM CRCA SHEET POWDER COATING IN SIEMENS GRAY SHADE, CABLE ENTRY WILL BE TOP and BOTTOM SUITABLE FOR CABLE ,LOCK, RUBBER GASKET, HARDWARE ETC. BUS BAR and HARDWARE 800A. TPN ALUMINIUM MAIN BUS BAR ,LOAD WISE SUB FEEDER BUS BAR COLOUR COATED HEAT SHRINK BUS BAR SLEAVE NUT-BOLT,WASHER ,HARDWARE ETC. WIRING and ACCESSORIESPOWER and CONTROL WIRING WILL BE (ISI 1100V) FLAME RETARDENT LOW SMOKE PVC SINGLE CORE COPPER WIRE,COPPER LUGGS, PVC SLEEVE, FERRULES, NUMBERS, HARDWARE and LABOUR ETC.Complete in all respect |
| 663 | ( UPS Panel ) Supply, installation, testing and commissioning of powder coated of Siemens grey of approved colour compartmentlised cubicle MV Panel fabricated out of 14/16 SWG thick CRCA sheet steel suitable for operation on 415 Volts, 50Hz, 3 Phase 4 wire AC supply . The panel shalll be indoor free standing, floor mounting, dust and vermin proof type, adeqate size cable alley with front operated rotary handles for MCCB`s complete with gland plates, lifting hooks, ventillating louvers, busbars, Inter connections, earthing, labelling electrical interlocking as per specification and drawings, suitable for termination of cables as per single line diagram including. supply and fixing of following switchgear and accessories complete as required. Copper Bus Bar 250A Electrolite grade E91 having cross section 1X50X10 mm for Phase, 1x25x6 mm for Neutral. The Panel should be extendable type. 10KVA UPS PANEL- (INDOOR NON TTA WALL MOUNTED) INCOMER FEEDERMCCB 4P 63A. 25KA. TM BASED WITH O/L and S/CPROTECTION , ROM and Spreader Links MCB SP 6A,10 KA C-CURVE |
| 664 | RED INDICATION LAMP RED LED TYPE, 240V AC YELLOW INDICATION LAMP YELLOW LED TYPE, 240V AC BLUE INDICATION LAMP BLUE LED TYPE, 240V AC NEUTRAL LINKOUTGOING FEEDERS MCB DP 25A. 10KA. C CURVE TYPE-12 NosENCLOSURE and ACCESSORIES FABRICATION IN 2.0/1.6MM CRCA SHEET POWDER COATING IN SIEMENS GRAY SHADE, CABLE ENTRY WILL BE TOP and BOTTOM SUITABLE FOR CABLE ,LOCK, RUBBER GASKET, HARDWARE ETC.BUS BAR and HARDWARE 100A. FP ALUMINIUM MAIN BUS BAR ,LOAD WISE SUB FEEDER BUS BAR COLOUR COATED HEAT SHRINK BUS BAR SLEAVE NUT-BOLT,WASHER ,HARDWARE ETC. WIRING and ACCESSORIES POWER and CONTROL WIRING WILL BE (ISI 1100V) FLAME RETARDENT LOW SMOKE PVC SINGLE CORE COPPER WIRE,COPPER LUGGS, PVC SLEEVE, FERRULES, NUMBERS, HARDWARE and LABOUR ETC.Complete in all respect |
| 665 | ( Lift Panel )Supply, installation, testing and commissioning of powder coated of Siemens grey of approved colour compartmentlised cubicle MV Panel fabricated out of 14/16 SWG thick CRCA sheet steel suitable for operation on 415 Volts, 50Hz, 3 Phase 4 wire AC supply . The panel shalll be indoor free standing, floor mounting, dust and vermin proof type, adeqate size cable alley with front operated rotary handles for MCCB`s complete with gland plates, lifting hooks, ventillating louvers, busbars, Inter connections, earthing, labelling electrical interlocking as per specification and drawings, suitable for termination of cables as per single line diagram including. supply and fixing of following switchgear and accessories complete as required. Aluminium Bus Bar 250A Electrolite grade E91 having cross section 1X50X10 mm for Phase, 1x25x6 mm for Neutral . LIFT PANEL- FOR EMERGENCY PANEL (INDOOR PTTA) INCOMER FEEDER FOR DG SET-1MCCB FP 100A. 25KA. TM BASED WITH O/L and S/C , PROTECTION SPREADER SET EXTENDED ROTARY HANDLEAUX plus TRIP ALARM CONTACT BLOCK ON/OFF/TRIP INDICATION LAMP MCB SP 6A,10 KA C-CURVE DIGITAL MULTIFUNCTION METER CL1.0 CL1.0 RED INDICATION LAMP RED LED TYPE, 240V AC YELLOW INDICATION LAMP YELLOW LED TYPE, 240V AC BLUE INDICATION LAMP BLUE LED TYPE, 240V AC CT`s 100/5A CL-1 FOR METERING CT SHORTING LINKNEUTRAL LINKOUTGOING FEEDERS MCCB FP 63A. 25KA. TM BASED WITH O/L and S/C , PROTECTION -04 SetsSPREADER SET EXTENDED ROTARY HANDLE ENCLOSURE and ACCESSORIES FABRICATION IN 2.0/1.6MM CRCA SHEET POWDER COATING IN SIEMENS GRAY SHADE, CABLE ENTRY WILL BE TOP and BOTTOM SUITABLE FOR CABLE ,LOCK, RUBBER GASKET, HARDWARE ETC. |
| 666 | BUS BAR and HARDWARE 150A. FP ALUMINIUM MAIN BUS BAR ,LOAD WISE SUB FEEDER BUS BAR COLOUR COATED HEAT SHRINK BUS BAR SLEAVE NUT-BOLT,WASHER ,HARDWARE ETC. WIRING and ACCESSORIES POWER and CONTROL WIRING WILL BE (ISI 1100V) FLAME RETARDENT LOW SMOKE PVC SINGLE CORE COPPER WIRE,COPPER LUGGS, PVC SLEEVE, FERRULES, NUMBERS, HARDWARE and LABOUR ETC. Make : UNIPAN/ISPL/TRICOLITE/VRINDAVAN ELECTRICALSVEHICLE CHARGING PANEL- (INDOOR PTTA) INCOMER FEEDER FOR DG SET-1 MCCB FP 250A. 25KA. TM BASED WITH O/L and S/C , PROTECTION SPREADER SETEXTENDED ROTARY HANDLE AUX plus TRIP ALARM CONTACT BLOCK ON/OFF/TRIP INDICATION LAMP |
| 667 | MCB SP 6A,10 KA C-CURVE DIGITAL MULTIFUNCTION METER CL1.0 CL1.0 RED INDICATION LAMP RED LED TYPE, 240V ACYELLOW INDICATION LAMP YELLOW LED TYPE, 240V AC BLUE INDICATION LAMP BLUE LED TYPE, 240V ACCT`s 250/5A CL-1 FOR METERING CT SHORTING LINKNEUTRAL LINK OUTGOING FEEDERS MCCB FP 125A. 25KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SETEXTENDED ROTARY HANDLE MCCB FP 100A. 25KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SETEXTENDED ROTARY HANDLE ENCLOSURE and ACCESSORIESFABRICATION IN 2.0/1.6MM CRCA SHEET POWDER COATING IN SIEMENS GRAY SHADE, CABLE ENTRY WILL BE TOP and BOTTOM SUITABLE FOR CABLE ,LOCK, RUBBER GASKET, HARDWARE ETC.BUS BAR and HARDWARE 300A. TPN ALUMINIUM MAIN BUS BAR ,LOAD WISE SUB FEEDER BUS BAR COLOUR COATED HEAT SHRINK BUS BAR SLEAVE NUT-BOLT,WASHER ,HARDWARE ETC. WIRING and ACCESSORIESPOWER and CONTROL WIRING WILL BE (ISI 1100V) FLAME RETARDENT LOW SMOKE PVC SINGLE CORE COPPER WIRE,COPPER LUGGS, PVC SLEEVE, FERRULES, NUMBERS, HARDWARE and LABOUR ETC.Complete in all respect |
| 668 | METER PANEL 4WAY- INDOOR TYPE PTTA INCOMER FEEDERMCCB FP 160A. 25KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SET EXTENDED ROTARY HANDLER, Y PHASE INDICATION LAMP LED TYPE, 240V AC BLUE PHASE INDICATION LAMP LED TYPE, 240V AC 6A. SP CONTROL MCB C CURVE DIGITAL VAF METER CL1.0CT`s 160/5A CL-1 FOR METERING CT SHORTING LINKNEUTRAL LINK OUTGOING FEEDERS 63A MCB FP 10KA C C CURVE TYPE SPACE FOR SINGLE PHASE KWH METER METER FIXING SHEET METER GLASS POWER TERMINAL BLOCKENCLOSURE and ACCESSORIES.Fabrication in 1.6/2.0mm.CRCA Sheet Powder Coating in Siemens Gray Shade, Wall mounted,Cable Entry will be Top and Bottom Suitable for Cable ,Lock, Rubber Gasket, hardware etc.BUS BAR and HARDWARE 200A. FP Aluminium Main Bus Bar,Load wise Sub Feeder Bus Bar Colour Coated Heat Shrink Bus Bar sleave Nut-Bolt,Washer ,Hardware etc.WIRING and CCESSORIES Power and Control Wiring will be (ISI 1100V) flamc smoke FRLS PVC Single Core Copper Wire,Copper Lugs, PVC Sleeve, Ferruels Numbers, Hardware and Labour etc.Complete in all respcet |
| 669 | METER PANEL 8WAY- INDOOR TYPE PTTA INCOMER FEEDERMCCB FP 200A. 25KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SET EXTENDED ROTARY HANDLER, Y PHASE INDICATION LAMP LED TYPE, 240V AC BLUE PHASE INDICATION LAMP LED TYPE, 240V AC 6A. SP CONTROL MCB C CURVE DIGITAL VAF METER CL1.0CT`s 200/5A CL-1 FOR METERING CT SHORTING LINKNEUTRAL LINK OUTGOING FEEDERS 63A MCB FP 10KA C C CURVE TYPE SPACE FOR SINGLE PHASE KWH METER METER FIXING SHEET METER GLASS POWER TERMINAL BLOCKENCLOSURE and ACCESSORIES. Fabrication in 1.6/2.0mm.CRCA Sheet Powder Coating in Siemens Gray Shade, Wall mounted,Cable Entry will be Top and Bottom Suitable for Cable ,Lock, Rubber Gasket, hardware etc. BUS BAR and HARDWARE 250A.TPN Aluminium Main Bus Bar,Load wise Sub Feeder Bus Bar Colour Coated Heat Shrink Bus Bar sleave Nut-Bolt,Washer ,Hardware etc.WIRING and ACCESSORIES Power and Control Wiring will be (ISI 1100V) flamc smoke FRLS PVC Single Core Copper Wire,Copper Lugs, PVC Sleeve, Ferruels Numbers, Hardware and Labour etc.Complete in all respect |
| 670 | METER PANEL 10WAY- INDOOR TYPE PTTA INCOMER FEEDERMCCB FP 250A. 25KA. TM BASED WITH O/L and S/C , PROTECTION. SPREADER SET EXTENDED ROTARY HANDLER, Y PHASE INDICATION LAMP LED TYPE, 240V AC BLUE PHASE INDICATION LAMP LED TYPE, 240V AC 6A. SP CONTROL MCB C CURVE DIGITAL VAF METER CL1.0CT`s 200/5A CL-1 FOR METERING CT SHORTING LINKNEUTRAL LINK OUTGOING FEEDERS 63A MCB FP 10KA C C CURVE TYPE SPACE FOR SINGLE PHASE KWH METER METER FIXING SHEET METER GLASS POWER TERMINAL BLOCKENCLOSURE and ACCESSORIES.Fabrication in 1.6/2.0mm.CRCA Sheet Powder Coating in Siemens Gray Shade, Wall mounted,Cable Entry will be Top and Bottom Suitable for Cable ,Lock, Rubber Gasket, hardware etc.BUS BAR and HARDWARE 300A.TPN Aluminium Main Bus Bar,Load wise Sub Feeder Bus Bar Colour Coated Heat Shrink Bus Bar sleave Nut-Bolt,Washer ,Hardware etc.WIRING and ACCESSORIES Power and Control Wiring will be (ISI 1100V) flamc smoke FRLS PVC Single Core Copper Wire,Copper Lugs, PVC Sleeve, Ferruels Numbers, Hardware and Labour etc.Complete in all respect |
| 671 | VEHICLE CHARGING PANEL- (INDOOR PTTA) INCOMER FEEDER FOR DG SET-1 MCCB FP 250A. 25KA. TM BASED WITH O/L and S/C , PROTECTION SPREADER SETEXTENDED ROTARY HANDLE AUX plus TRIP ALARM CONTACT BLOCK ON/OFF/TRIP INDICATION LAMP MCB SP 6A,10 KA C-CURVE DIGITAL MULTIFUNCTION METER CL1.0 CL1.0 RED INDICATION LAMP RED LED TYPE, 240V ACYELLOW INDICATION LAMP YELLOW LED TYPE, 240V AC BLUE INDICATION LAMP BLUE LED TYPE, 240V AC CT`s 250/5A CL-1 FOR METERING CT SHORTING LINK NEUTRAL LINKOUTGOING FEEDERS MCCB FP 125A. 25KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SET EXTENDED ROTARY HANDLE MCCB FP 100A. 25KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SET EXTENDED ROTARY HANDLEENCLOSURE and ACCESSORIES FABRICATION IN 2.0/1.6MM CRCA SHEET POWDER COATING IN SIEMENS GRAY SHADE, CABLE ENTRY WILL BE TOP and BOTTOM SUITABLE FOR CABLE ,LOCK, RUBBER GASKET, HARDWARE ETC. |
| 672 | BUS BAR and HARDWARE300A. TPN ALUMINIUM MAIN BUS BAR ,LOAD WISE SUB FEEDER BUS BAR COLOUR COATED HEAT SHRINK BUS BAR SLEAVE NUT-BOLT,WASHER ,HARDWARE ETC. WIRING and ACCESSORIESPOWER and CONTROL WIRING WILL BE (ISI 1100V) FLAME RETARDENT LOW SMOKE PVC SINGLE CORE COPPER WIRE,COPPER LUGGS, PVC SLEEVE, FERRULES, NUMBERS, HARDWARE and LABOUR ETC.Complete in all respect |
| 673 | DG METER PANEL 4WAY- INDOOR TYPE PTTA INCOMER FEEDER MCCB FP 100A. 25KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SET EXTENDED ROTARY HANDLER, Y PHASE INDICATION LAMP LED TYPE, 240V AC BLUE PHASE INDICATION LAMP LED TYPE, 240V AC 6A. SP CONTROL MCB C CURVE DIGITAL VAF METER CL1.0CT`s 100/5A CL-1 FOR METERING CT SHORTING LINKNEUTRAL LINK OUTGOING FEEDERS 40A MCB FP 10KA C C CURVE TYPE SPACE FOR METER METER FIXING SHEET METER GLASS 32A. FP ACCL 3 PHASE POWER TERMINAL BLOCKENCLOSURE and ACCESSORIES. Fabrication in 1.6/2.0mm.CRCA Sheet Powder Coating in Siemens Gray Shade, Wall mounted,Cable Entry will be Top and Bottom Suitable for Cable ,Lock, Rubber Gasket, hardware etc. BUS BAR and HARDWARE 150A. FP Aluminium Main Bus Bar,Load wise Sub Feeder Bus Bar Colour Coated Heat Shrink Bus Bar sleave Nut-Bolt,Washer ,Hardware etc.WIRING and ACCESSORIES Power and Control Wiring will be (ISI 1100V) flamc smoke FRLS PVC Single Core Copper Wire,Copper Lugs, PVC Sleeve, Ferruels Numbers, Hardware and Labour etc.Complete in all respect |
| 674 | DG METER PANEL 8WAY- INDOOR TYPE PTTA INCOMER FEEDER MCCB FP 160A. 25KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SET EXTENDED ROTARY HANDLER, Y PHASE INDICATION LAMP LED TYPE, 240V AC BLUE PHASE INDICATION LAMP LED TYPE, 240V AC 6A. SP CONTROL MCB C CURVE DIGITAL VAF METER CL1.0CT`s 160/5A CL-1 FOR METERING CT SHORTING LINKNEUTRAL LINK OUTGOING FEEDERS 40A MCB FP 10KA C C CURVE TYPE SPACE FOR METER METER FIXING SHEET METER GLASS 32A. FP ACCL 3 PHASE POWER TERMINAL BLOCKENCLOSURE and ACCESSORIES.Fabrication in 1.6/2.0mm.CRCA Sheet Powder Coating in Siemens Gray Shade, Wall mounted,Cable Entry will be Top and Bottom Suitable for Cable ,Lock, Rubber Gasket, hardware etc.BUS BAR and HARDWARE 200A. FP Aluminium Main Bus Bar,Load wise Sub Feeder Bus Bar Colour Coated Heat Shrink Bus Bar sleave Nut-Bolt,Washer ,Hardware etc.WIRING and ACCESSORIES Power and Control Wiring will be (ISI 1100V) flamc smoke FRLS PVC Single Core Copper Wire,Copper Lugs, PVC Sleeve, Ferruels Numbers, Hardware and Labour etc. |
| 675 | DG METER PANEL 10WAY- INDOOR TYPE NON TTAINCOMER FEEDER MCCB FP 160A. 25KA. TM BASED WITH O/L and S/C , PROTECTION.SPREADER SET EXTENDED ROTARY HANDLE R, Y PHASE INDICATION LAMP LED TYPE, 240V AC BLUE PHASE INDICATION LAMP LED TYPE, 240V AC 6A. SP CONTROL MCB C CURVE DIGITAL VAF METER CL1.0CT`s 160/5A CL-1 FOR METERING CT SHORTING LINKNEUTRAL LINK OUTGOING FEEDERS 40A MCB FP 10KA C C CURVE TYPE SPACE FOR METER METER FIXING SHEET METER GLASS 32A. FP ACCL 3 PHASE POWER TERMINAL BLOCKENCLOSURE and ACCESSORIES. Fabrication in 1.6/2.0mm.CRCA Sheet Powder Coating in Siemens Gray Shade, Wall mounted,Cable Entry will be Top and Bottom Suitable for Cable ,Lock, Rubber Gasket, hardware etc. BUS BAR and HARDWARE 200A. FP Aluminium Main Bus Bar,Load wise Sub Feeder Bus Bar Colour Coated Heat Shrink Bus Bar sleave Nut-Bolt,Washer ,Hardware etc. WIRING and ACCESSORIES Power and Control Wiring will be (ISI 1100V) flamc smoke FRLS PVC Single Core Copper Wire,Copper Lugs, PVC Sleeve, Ferruels Numbers, Hardware and Labour etc.Complete in all respect. |
| 676 | Supply , installation, testing and commissioning of Neutral Grounding Resistor Panel (NGR) for 1000KVA Transformer with cubicles of sheet metal steel enclosed with dust, moisture and vermin proof having degree of protection as IP 55 Floor mounted shall be adequate to cater for proper cabling. Resistors shall be designed to ensure excess current and voltage being given a low resistive path for quick flow in the earth. The resistor shall be able to carry 10 % of its rated current continuously with the enclosure surface temperature rise not more than 5 oC of ambient temperature specified.Resistor shall be a natural air-cooled type and forced cooling shall not be used. Resistor shall be Cupro- Nickel Wire Wound Type on grooved, non- hygroscopic, high alumina, porcelain former with START and FINISH bands and a variable band for resistance variation. NGR Panel Equipped with Neutral Displacement relay which will ensure alarm signal during fault conditions and gives tripping command to connected breaker.The porcelain former shall have mounting clamps to mount the same on the NGR Panel as per IEEE32,IEC60076,IS 3043 Complete in all respect |
| 677 | Supply installation testing and commIssioning of 1000KVA Compact Substation1000 KVA PSS WITH 1000 KVA, 11/0.433KV DRY CRT OCTC TRANSFORMER WITH ECBC-2017 LOSSES HT SWITCHGEAR 11KV INDOOR TYPE 1WAY NON EXTENSIBLE SF6 INSULATED RING MAIN UNIT (RMU), 630A, 21 KA CONSISTING OF 1NOS. MANUAL VACCUM CIRCUIT BREAKER (VCB) STAINLESS STEEL TANK WITH ACCESSORIES-SELF POWERED O/C and E/F IDMT RELAY, MANUAL PUSH BUTTONS FOR CLOSING/TRIPPING, SF6 GAS PRESSURE MANOMETER, PADLOCKING FACILITY AND IP67 DEGREE OF PROTECTION OF SF6 TANK, WITH SERIES TRIP .RMUshall be capable for cable termination of 1R x 1C x 300 Sq.mm Unarmoured Al XLPE Cable. TRANSFORMER SECTION 1000 KVA, 11/0.433 kV, DYN11, 3 PHASE, 50HZ, CAST RESIN CAST DRY TYPE TRANSFORMER WITH COPPER WINDING, plus 7.5% TO -7.5% @ 2.5% (IN STEPS OF) EACH WITH OFF CIRCUIT TAP CHANGER (OCTC) HAVING CLASS-F INSULATION, AN COOLING and TEMPERATURE RISE IN WINDING OF 90 DEG. C [MAX.] OVER AMBIENT TEMPERATURE 50 DEG. C ALONG WITH STANDARD FITTINGS and ACCESSORIES. LOSSES AS PER ECBC 2017, LATEST AMENDMENT, AS PER IS-11171.LT PANEL LT PANEL FOR 1000 KVA PSS HAVING1000 KVA, 11/0.433KV CAST RESIN DRY TYPE |
| 678 | TRANSFORMER WITH OCTC INCOMER: 11600A 4P ACB 50KA EDO MICROPROCESSOR RELEASE WITH O/C, S/C and E/F WITH PROT. - LSIG EM6400NG plus CL 1.0, LED DISPLAY, THD, 15TH HARMONICS, RS-485 T-N-C SELECTOR SWITCH AUTO/MANUAL SELECTOR SWITCH WITH OFF, 2P, 2W MAIN AL. BUS BAR (NEUTRAL 50%) 1600A TPN POLE (50% NEUTRAL) ALUMINIUM BUSBAR DULY INSULATED WITH COLOR CODED HEAT SHRINKABLE SLEEVES AND SUPPORTED WITH BUS BAR SUPPORTS AND INSULATORS - SMC/DMC. CROSS-SECTION AREA CONSIDERED 2 X 100 X 10 - SQ. MM FOR PHASES / EQV. E91 E GRADE 1 X 100 X 10 - SQ. MM FOR NEUTRAL / EQV. 1 X 50 X 06 - SQ. MM FOR EARTHING ENCLOSURE : FLOOR MOUNTED, INDOOR TYPE MS CRCA SHEET 1.6MM/2MM WITH 3MM GLAND PLATE DULY POWDER COATED IN , PANEL LOCKS, PU GASKETS IN DOORS, TYPE FLOOR MOUNTED, INDOOR TYPE, DUST AND VERMIN PROOF WITH REINFORCEMENT. PANEL ACCESSORIES - DOOR HINGES, PROTECTION COVERS, PANEL NAME PLATE, FEEDER NAME PLATES AND HARDWARES - NUTS, BOLTS, WASHERS - PLAIN AND SPRING FOR BUS BAR AND PANEL CONSTRUCTION ALONG WITH PANEL SHROUDING ACCESS. Complete inall respect |
| 679 | DG Set 500 KVA (The DG Set pollution norms should compliance to latest norms of CPCB-IV plus ) liquid cooled, turbocharged with after cooler, developing 608 hp @ 1500 RPM or as per OEM design, electric start, compression ignition, 4 stroke engine designed to run continuously at 1500 RPM confirming to rime rating ISO-3046 standard with an overload capacity of 10 % for one hour in every 12 hrs of operation. Diesel Engine conforms to present CPCB norms VI plus norms. 500 KVA . The diesel engine will comprise of following: ?Flywheel with Starter Ring for Generating Set. Air filter. Lube oil cooler assembly with accessories. ?Exhaust air manifold. ? Exhaust Silencer. ?Expansion bellow. Fuel filter. Lube oil filter. Exhaust gas Turbocharger with after cooler. Radiator with pusher type fan, with fan guard, coolant pump. 24 V (2 x 12 V) electrical starting system with starter motor and battery charging alternator with Electronic Governing Engine mounting supports. Engine control panel – Microprocessor based Controller . Engine Safeties, Alarms and Trips ( Details in Controller specifications) K Cool super plus corrosion inhibitor coolant for cooling. ?Engine Operator/Maintenance and Spare parts CD Engine Warranty Certificate. Engine test certificate ALTERNATOR 500 KVA, 415 Volts, 3 Phase, 4 wire, 0.8 p.f. (lag), 50Hz, 1500RPM, in accordance with IS 4722 as per following specifications: Type: Salient poles, Single bearing, Brushless type, suitable for direct coupling to engine.Rating: Guaranteed to deliver required output at the ambient temperature conditions. Suitable for an over-load of 10% for 1 hour in every 12 hours of operation. Voltage Regulation: Provided with fast response thyristor type electronic automatic voltage regulator, which holds output voltage within desired limits. (±1%). Excitation: Self excited-self regulated |
| 680 | Alternator Loading: Suitable for taking rated load immediately after machine reaches rated voltage and speed. winding to give performance, Vibration: Suitable for direct coupling with Engine and mounted on common fabricated sheet metal base frame.? Enclosure: Screen protected drip proof enclosure ESSENTIAL ACCESSORIES One Following set of essential accessories are supplied with each DG set. ? One No. MS Base Frame suitable for mounting of the offered engine and alternator. ? One No. fuel tank of standard capacity as per OEM complete fuel gauge, inlet/outlet connections, drains plug, etc.Two No. 12 Volts DC Battery of suitable capacity with leads. 1 Set of AVM Pads fitted in Base Frame. All above accessories are housed in acoustic enclosure. MANUAL CONTROL PANEL The Control Panel body will be fabricated out of 16 SWG MS sheet. Panel will be suitable for inside Canopy mounting, Indoor Installation, Copper Control cable of suitable size is used. Cables are ferruled for proper maintenance/checking/wiring of panel. Detachable cable gland plates are provided. The panel will be equipped as follows: One No. Moulded Case Circuit Breaker of suitable capacity. Aluminium Bus Bars of suitable capacity provided with termination. ? 3 Nos. Current Transformers of suitable ratio. ? One set of instruments MCB’S. ? Microprocessor based controller controlling various Mechanical and Electrical protections with display and indications of Electrical and Mechanical Parameters fuel consumption (approx) as per code. IS 13018. IEC 60034 performance ISO 8528 complete in all respect` Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail