| 1 | Earth work in excavation by mechanical means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge., and as per DSR Item 2.6.1 |
| 2 | Earth Work in filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift., and as per DSR Item 2.25(A) |
| 3 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors., and as per DSR Item 4.1.8 |
| 4 | Sand filling in plinth including supply of necessary quantity of sand from a distance not excluding 8km from the site of work and including watering dressing etc. rate to include cost of all materials, labour and T&P etc.required for proper completion of the work., and as per DSR Item 2.27 |
| 5 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 to match the existing floor With Chlorpyriphos/Lindane E.C. 20% with 1% concentration , and as per DSR Item 2.35.3 |
| 6 | Providing and laying in position specified grade of reinforced cement concrete work in Plinth Beam , Footing and Column , excluding the cost of centering, shuttering, finishing and reinforcement - 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size ), and as per DSR Item 5.1.2 |
| 7 | RCC work in Lintels, Slab, Beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) in Ground Floor, and as per DSR Item 5.3 |
| 8 | RCC work in Column above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size in Ground Floor, and as per DSR Item 5.2.2 |
| 9 | Boring with hydraulic piling rigs with power units, providing and installing cast in situ 300 mm dia piles single bulb under reamed piles and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap), and as per DSR Item 20.3.1 |
| 10 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo Mechanically Treated bars of grade Fe-500D or more., and as per DSR Item 5.22.6 |
| 11 | Class M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. , and as per DSR Item 6.1.2 |
| 12 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size ), and as per DSR Item 4.1 |
| 13 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil., and as per DSR Item 4.13 |
| 14 | Brick work in super-structure above plinth level including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand). Ground Floor and First Floor, and as per DSR Item 6.4.2 |
| 15 | Half brick masonry with Class M-150 First Class Brick in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) For Ground Floor and First Floor, and as per DSR Item 6.13.2 |
| 16 | 15 mm plinth plaster with 1 cement : 4 coarse sand incl all charges and as directed by EinC, and as per DSR Item 13.5.1 |
| 17 | 12 mm Cement Mortar plaster with 1 cement : 6 coarse sand incl all charges and as directed by EinC For Ground Floor and First Floor, and as per DSR Item 13.4.2 |
| 18 | 15 mm cement plaster on rough side of single or half brick wall of mix 1 cement : 6 coarse sand in Ground Floor and First Floor, and as per DSR Item 13.5.2 |
| 19 | Plaster with 1:3 Cement sand Mortar in drip course / groove in plastered surface or moulding to R.C.C. projections., and as per DSR Item 5.3 |
| 20 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (40 mm flooring), and as per DSR Item 11.3.1 |
| 21 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry / Ruby Red or equivalent, and as per DSR Item 8.2.2.2 |
| 22 | Providing and laying vitrified floor tiles in specified sizes (Size of Tile 600x600 mm) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc complete. , and as per DSR Item 11.41.2 |
| 23 | Providing and laying Vitrified tiles in specified sizes (Size of Tile 600x600 mm) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc complete. , and as per DSR Item 11.46.2 |
| 24 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (a) 35mm thick Second class teak wood., and as per DSR Item 9.9.1.1 |
| 25 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete With 2nd class teak wood beading 62X19 mm, and as per DSR Item 9.135.2 |
| 26 | Providing and fixing ISI marked Single Leaf flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws, and as per DSR Item 9.21.1 |
| 27 | Providing and fixing ISI marked Double Leaf flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws, and as per DSR Item 9.21.1 and 9.26 |
| 28 | Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) , and as per DSR Item 9.22.1 |
| 29 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured)., and as per DSR Item 9.23 |
| 30 | Providing and fixing of 100-150 mm door stoper Make : Straits/Astro/Root or eq |
| 31 | Providing and fixing Brass/Antiqe finish door locks approved quality with necessary screws etc. complete. |
| 32 | Providing & fixing Steel rod aluminium body Satin Finish ISI marked with nuts and screws etc complete. (a) 300mm x 10mm . |
| 33 | Providing & fixing Steel rod aluminium body Satin Finish ISI marked with nuts and screws etc complete. (b) 250 mm x 10mm. |
| 34 | Providing and fixing Brass handles with screws etc. complete (a) 125 mm |
| 35 | Providing and fixing ISI marked aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete , and as per DSR Item 9.83 |
| 36 | Fixing DOOR chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. , and as per DSR Item 14.2.1 |
| 37 | Fixing WINDOW chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. , and as per DSR Item 14.2.2 |
| 38 | Fixing CLERESTORY WINDOW chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. , and as per DSR Item 14.2.3 |
| 39 | 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws with Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) both side laminated., and as per DSR Item 9.20.3 + 9.22.1*2 |
| 40 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 , and as per DSR Item 10.15.1 |
| 41 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a) Sal Wood., and as per DSR Item 9.1.2 |
| 42 | French spirit polishing : Two or more coats on new works including a coat of wood filler. , and as per DSR Item 13.68.1 |
| 43 | Providing and fixing uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). , and as per DSR Item 9.147 D.2 |
| 44 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood (a) 50 x 20 mm, and as per DSR Item 9.40.1.2 |
| 45 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3, Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work., and as per DSR Item 13.62.1 |
| 46 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), and as per DSR Item 13.47.1 |
| 47 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats, and as per DSR Item 13.62.1 |
| 48 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , and as per DSR Item 13.8 |
| 49 | P/L integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound over the RCC slab including adjoining walls upto 300 mm height. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 admixed with water proofing compound including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in Charge (Average thickness of 120 mm and minimum thickness at khurra as 65 mm)., and as per DSR Item 22.7.1 |
| 50 | S/O Hand rail and balustrade modular system passive SS-304 grade decorative railling system comprising of hand rail 50mm thick and 3 No.hortzontal steel pipe of 19mm dia and 1.5mm thick of equal spacing with balustrade of SS pipe of 38mm and 1.5mm thick @ 1200 mm C/C of passivated SS 304 rade and fix duly on the floor with spacially rivet expansion bolt and finish the surface food and covering with steel shope with all visible stainless metal of 304 grade in satin finsh hight of ralling is 900mm as per detailed specification., and as per DSR Item 10.28 |
| 51 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without any pigment., and as per DSR Item 11.20.4 |
| 52 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete., and as per DSR Item 5.9.1 |
| 53 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick., and as per DSR Item 5.9.20 |
| 54 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick, and as per DSR Item 5.9.21 |
| 55 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns,Pillars, Piers, Abutments, Posts and Struts., and as per DSR Item 5.9.6 |
| 56 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. (DSR Item no.- 17.78) (Jaquar Make.) |
| 57 | Providing and fixing wash basin with C.I.brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls where required :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. (DSR Item no.- 17.7.3) (Jaquar Make.) |
| 58 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : with 5 litre white P.V.C. automatic flushing Cistern. (DSR Item no.- 17.4.1) (Jaquar Make.) |
| 59 | Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth. Granite stone of approved shade. (DSR Item no.- 8.10.2) (Jaquar Make.) |
| 60 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink without drain board 610X510 mm bowl depth 200mm. (DSR Item no.- 17.10.1.2) |
| 61 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. (DSR Item no.- 17.70.1) (Jaquar Make.) |
| 62 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm. (DSR Item no.- 17.32.2) |
| 63 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. (DSR Item no.- 17.33) (Jaquar Make.) |
| 64 | Providing and fixing C.P. brass toilet paper holder : (DSR Item no.- 17.34.1) (Jaquar Make.) |
| 65 | Providing and fixing 100mm dia centrifugally cast (spun) iron S&S pipe cast (spun) iron S&S pipe. (DSR Item no.- 17.35.1.2) |
| 66 | Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. For 100mm dia. Pipe. (DSR Item no.- 17.37.1) |
| 67 | Providing and fixing heel rest sanitary bend of 100mm Centrifugally cast (spun) iron pipe S&S (DSR Item no.- 17.40.1.2) |
| 68 | Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 100X100X100mm Sand cast iron S&S as per IS : 3989. (DSR Item no.- 17.43.1.2) |
| 69 | Providing and fixing Plain Junction of required degree of 100X100X100mm Sand cast iron S&S as per IS : 3989. (DSR Item no.- 17.44.1.2) |
| 70 | Providing and fixing terminal guard 100 mm Dia Sand cast iron S&S as per IS - 3989. (DSR Item no.- 17.56.1.2) |
| 71 | Providing and fixing 100 mm dia collar Sand cast iron S&S as per IS - 3989. (DSR Item no.- 17.57.1.2) |
| 72 | Providing and lead 100 Dia caulked joint Sand cast iron S&S as per IS - 3989. (DSR Item no.- 17.58.1.2) |
| 73 | Providing and fixing cast iron trap of self cleansing design with cast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors. 100 mm inlet and 100 mm outlet,Sand cast iron S&S as per IS: 3989. DSR Item no.- 17.60.1.1) |
| 74 | Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 100 mm inlet and 100 mm outlet,Sand cast iron S&S as per IS: 3989. (DSR Item no.- 17.65.1) |
| 75 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. (DSR Item no.- 17.71) (Jaquar Make.) |
| 76 | Providing and fixing PTMT towel rail complete with brackets fixed wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. approved quality and colour weighing not less than 105 gms. (DSR Item no.- 17.73.2) |
| 77 | Providing and fixing of 20 mm dia nominal bore Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge..Internal work - Exposed on wall. (DSR Item no.- 18.7.2) |
| 78 | Providing and fixing of 25 mm dia nominal bore Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge..Internal work - Exposed on wall. (DSR Item no.- 18.7.3) |
| 79 | Providing and fixing of 32 mm dia nominal bore Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge..Internal work - Exposed on wall. (DSR Item no.- 18.7.4) |
| 80 | Providing and fixing 15 mm dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (DSR Item no.- 18.8.1) |
| 81 | Providing and fixing 20 mm dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (DSR Item no.- 18.8.2) |
| 82 | Providing and fixing of 40 mm dia, nominal bore Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. (DSR Item no.- 18.9.5) |
| 83 | Providing and fixing of 50 mm dia, nominal bore Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. (DSR Item no.- 18.9.6) |
| 84 | Providing and fixing of 65 mm dia, nominal bore Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. (DSR Item no.- 18.9.7) |
| 85 | Providing and fixing of 32 mm dia gun metal gate valve with CI wheel of approved quality (screwed ends). (DSR Item no.- 18.17.1) |
| 86 | Providing and fixing of 40 mm dia gun metal gate valve with CI wheel of approved quality (screwed ends). (DSR Item no.- 18.17.1) |
| 87 | Providing and fixing of 50 mm dia gun metal gate valve with CI wheel of approved quality (screwed ends). (DSR Item no.- 18.17.3) |
| 88 | Providing and fixing uplasticised PVC connection pipe with brass unions : 15 mm nominal bore 45 cm Length. (DSR Item no.- 18.21.2 ) |
| 89 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 100 mm diameter. (DSR Item no.- 18.22.1) |
| 90 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore. (DSR Item no.- 18.51.1) |
| 91 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore. (DSR Item no.- 18.53.1) |
| 92 | Providing and fixing PTMT 100 mm nominal dia Circular type grating of approved quality and colour. (DSR Item no.- 2.10.1.2) |
| 93 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. (DSR Item no.- 2.10.1.2) |
| 94 | Providing and laying 150 mm diameter cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round R.C.C. pipes including bed concrete as per standard design : (DSR Item no.- 19.2.2) |
| 95 | Providing and laying 250 mm diameter cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round R.C.C. pipes including bed concrete as per standard design : (DSR Item no.- 19.2.4) |
| 96 | Providing and fixing 100x100 mm size P type With F.P.S. Bricks class designation 75 square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than. (DSR Item no.- 19.4.1.1) |
| 97 | Providing and laying 150 mm dia Non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (DSR Item no.- 19.6.2) |
| 98 | Providing and laying 250 mm dia Non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (DSR Item no.- 19.6.3) |
| 99 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With F.P.S. bricks with class designation 150. (DSR Item no.- 19.7.1.1) |
| 100 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With F.P.S. bricks with class designation 150. (DSR Item no.- 19.7.1.2) |
| 101 | Providing and fixing on wall face unplasticised Rigid 110 mm diameter PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1 0 mm gap for thermal expansion, (i) Single socketed pipes. (DSR Item no.- 19.41.2) |
| 102 | Providing and fixing 100 mm diameter M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x1010 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. (DSR Item no.- 19.38.1) |
| 103 | Providing and fixing on wall face unplasticised 110 mm dia 87.5° Bend (Plain) PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR Item no.- 12.42.5.1) |
| 104 | Providing and fixing on wall face unplasticised 110 mm Shoe (Plain) of PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR Item no.- 12.42.6.2) Please Enable Macros to View BoQ information |