| 1 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering, complete all as specified and directed by the Engineer-in-Charge. |
| 2 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated profile steel sheet 0.50mm thick of colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by the Engineer-in-Charge. |
| 3 | S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of colour having tensile strength of 550 Mpa as in roof covering/cladding to ridges, valley gutters etc. fixed with self tapping screws, complete all as specified and directed by the Engineer-in-Charge. |
| 4 | Dismantling wall and ceiling board (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and directed by the Engineer-in-Charge. |
| 5 | S&F 15mm thick 2nd class softwood clean sawn boarding as in eaves board fixed with nails in any situation, complete all as specified and directed by the Engineer-in-Charge. |
| 6 | S&F GI frame work size of grid 605 x 605 mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from sofit at approx 900 mm centre to centre with GI cleat and steel expansion fasterner with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips acress the intermediate channel at 457mm centre to cnetre including hangers 6mm dia.GI (upto 1200mm length) adjusting level fixed tp roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm ling and expansion hold fasterner 12.5mm dia 40mm long including S&F 8mm thick Gypsum boards as in ceiling fixed on GI frame work, complete all as specified and directed by Engineer-in-Charge. |
| 7 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified. |
| 8 | Demolition of cement concrete (un reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including disposal of unserviceable materials,debris and rubbish to a distance not exceeding 100 metre, complete all as specified and as directed by the Engineer-in-Charge. |
| 9 | M&L 75 mm thick Plain cement concrete, 1:4:8, type D-2 using 40mm graded crushed stone aggregate, as in sub-base of floor/path etc. finishing surfaces even and fair, complete all as specified and as directed by the Engineer-in-Charge. |
| 10 | M&L 25mm thick Plain cement concrete, 1:2:4, type B-0 using 12.5mm graded crushed stone aggregate, surface finished fair to receive top layer of flooring, complete all as specified and as directed by the Engineer-in-Charge. |
| 11 | M&L Non skid ceramic coloured tiles Ist quality 7 to 8mm thick, (square/ rectangular), area of each tile exceeding 0.18sqm, but not exceeding 0.38 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed by the Engineer-in-Charge. |
| 12 | M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed by the Engineer-in-Charge |
| 13 | M&L Glazed ceramic tiles, coloured, of size 350mm x 250mm/450 mm x 300mm, thickness not less than 7mm as in vertical surfaces such as skirting/dado etc, set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match the shade of tile, fixed over and including 10mm thick rendering (bedding layer) on brick/concrete surface in cement mortar 1:4, complete all as specified and as directed by the Engineer-in-Charge. |
| 14 | Dismantling timber scantling 40 Sq cm and over in section in any position, unframed work, complete all as specified and as directed by the Engineer-in-Charge. |
| 15 | M&L 2nd class soft wood (Kail) as in scantling, clean sawn timber, fixed in framed work, complete all as specified and as directed by the Engineer-in-Charge. |
| 16 | Taking down chowkat or frames with shutters (without taking off shutters from the frames) area n.exc 1.5 Sqm each including cutting holes for taking out hold fasts, dismantling brick work (holes cut and any other damages to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost) , complete all as specified and directed by the Engineer-in-Charge. |
| 17 | Taking down chowkat or frames with shutters (without taking off shutters from the frames) exc. 1.5 Sqm but n.exc 4 Sqm each including cutting holes for taking out hold fasts, dismantling brick work (holes cut and any other damages to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost), complete all as specified and as directed by the Engineer-in-Charge. |
| 18 | S&F Solid PVC door frame of size 50mmx47mm made out of 5mm single side pre-lam colour PVC sheet and edges will be painted to match with pre-lam sheet reinforced with MS square tube, supplied and fitted in openings as per specification & drawings shown in SSR Part-II,, complete all as specified and as directed by the Engineer-in-Charge. |
| 19 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS Frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed by the Engineer-in-Charge. |
| 20 | S&F Aluminium anodised, barrel tower bolt of extruded section and fixed, 100 mm long (ISI marked), complete all as specified as directed by the Engineer-in-Charge. |
| 21 | S&F in repairs Butt hinges, medium weight, cold rolled, mild steel 75mm long (ISI marked), complete all as specified and directed by the Engineer-in-Charge. |
| 22 | S&F extruded aluminium alloy handles, fabricated type, anodised, 100 mm long (ISI marked), complete all as specified and directed by the Engineer-in-Charge. |
| 23 | M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not other wise described and treated with creosote oil, complete all as specified and directed by the Engineer-in-Charge. |
| 24 | M&L 75 mm thick Plain cement concrete, 1:3:6, type C-2 using 40mm graded crushed stone aggregate, as in plinth protection/ path etc. and finishing surfaces even and fair, complete all as specified and as directed by the Engineer-in-Charge. |
| 25 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles, complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L for Brick work with sub class `B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6, complete all as specified and directed by the Engineer-in-Charge. |
| 27 | Taking down plastering in cement lime or cement mortar on brick or stone masonary etc. including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed by the Engineer-in-Charge. |
| 28 | M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as specified and directed by the Engineer-in-Charge. |
| 29 | M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, surface finished even and smooth without using extra cement, complete all as specified and directed by the Engineer-in-Charge. |
| 30 | M&L for Preparation of new plastered surfaces on walls and applying two coats of oil bound distemper over a coat of 3mm wall care putty, complete all as specified and as directed by Engineer-in-charge. |
| 31 | M&L for preparing new plastered of walls and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfaces complete all as specified and directed. |
| 32 | S&F 2nd class hard wood Plain, solid, straight chowkats and frames, wrought , framed rebated on the solid , rounded or chamfered put together with glue pinned at joints, supplied and fixed. |
| 33 | S&F 35 mm thick 2nd class hard wood Plain framed, panelled shutters (any number of panels), with panel of timber flat on both sides (feather edged) or 12 mm thick BWP of veneered particle board medium density wood commercial face veneers fixed to chowkats. |
| 34 | S&F 2nd class hardwood glazed and skelton window/ ventilator shutters 25 mm thick divided into squares open rebated and prepared to receive glass, gauge etc (provided with stiles and rails) edges of framing plain, chamfered, rounded fitted with mitred beads for securing glass etc, size of members as specified in SSR Pt I section 8 clause 8.20 (a) supplied and fitted to chowkats with plain, chamfered or rounded mitred and rebated bars any numbers. |
| 35 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and avgerage width of aperature 1.18 mm fixed with tinned tacks, or galvanised wire staples. |
| 36 | S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane, complete all as specified. |
| 37 | Hacking out old broken glass (any thickness, size, quality or description) from wooden, steel,frame or stone, concrete or brick surrounds, incl punching or drilling out old glazing pins/spring clips and providing and fixing new ones. |
| 38 | Taking up or down 15 mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specifed and directed. |
| 39 | M&L 25mm outer dia 5-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed. |
| 40 | Taking up or down 20 mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specifed and directed. |
| 41 | M&L 32mm outer dia 5-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed. |
| 42 | Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of shelves , for water tubing etc and making good, cutting exc 10cm girth but not exc 20cm girth in brick/stone walls. |
| 43 | Dismantiling of water tanks of capacity n. exc 250 & exc 500 ltrs including all necessary fittings complete. |
| 44 | S&F 500 ltrs PVC rotational moulded polyethylene water storage tanks triple layer made (cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR part-I |
| 45 | S&F 32 mm dia PPP-R gate valves (Brass inserted) as per requirment of the site complete all as specified. |
| 46 | S&F 32 mm dia PPP-R ball valves (Brass inserted) as per requirment of the site complete all as specified. |
| 47 | S&F in repair Vitreous china wash hand basin (550X400mm) white, flat back excluding taps, including brackets & 32mm waste coupling complete all as specifed and directed. |
| 48 | S&Fin repair 15mm dia fancy type chromium plated Bib taps cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipes or for brass ferrule |
| 49 | S&F in repair 15mm dia stop valves/angle valve chromium plated, fancy type with long shank and cup screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions as specified . |
| 50 | S&F 15mm PVC connection 450mm long with PTMT nuts of superior quality as specified. |
| 51 | Dismantling of drain pipes of size 100mm bore or below (Salt glazed ware/AC pipe/reinforced concrete pipe/CI/PVC pipe ) set in cement mortar including concrete bed & haunching (if required) and removing away complete from site, complete all as specified and as directed by the Engineer-in-Charge. |
| 52 | S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls complete |
| 53 | S&F 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls complete |
| 54 | S&F 110mm PVC (SWR) bends with or without access door complete all as specified and directed. |
| 55 | S&F 75mm PVC (SWR) bends with or without access door complete all as specified and directed. |
| 56 | M&L 75mm PVC (SWR) floor trap , plain with grating including jointing with solvent cement complete all as spd and directed |
| 57 | S&F in repairs Vitreous Chinaware squatting pan, orissa pattern size 580mm x 440mm with integral foot rests, white and Size 110 x 110 PVC ‘S’ trap, front or back inlet, including provision of lime concrete, and making good to floors, complete all as specified and directed by the Engineer-in-Charge. |
| 58 | S&F in repair Viterous China urinal, half stall urinal (back or corner wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe), complete all as specified as directed by the Engineer-in-Charge. |
| 59 | S&F 10 Litre PVC valveless syphonic action flushing cistern low level white with inlet ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC 32 mm dia for low level cistern. |
| 60 | S&F in repair 15mm dia fancy type pillar taps, cast copper alloy with capstan heads, chromium plated scewed down high pressure with or without lettered Hot or cold with long screwed shanks and fly nuts screwed for iron pipe fixed complete all as specified. |
| 61 | Note :- An amount of Rs. Rs 24,615.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |