| Sl. No. | Item Description |
| 1 | =B2& \\" BoQ\\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (R&D) SECUNDERABAD Name of Work: SPECIAL REPAIRS TO AUDITORIUM ANNEXE (GROUND FLOOR DH ANNEXE BUILDING) IN TECHNICAL AREA AT CVRDE AVADI CHENNAI Contract No: CERD/AVD/TOKEN/86 OF 2025-2026 Bidder Name : PRICE SCHEDULE(This BoQ template must not be modified / replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SlNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Rate in Figures to be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes Total Amount Total Amount in Words |
| 2 | Demolishing cement concrete (unreinforced) in manually / by mechanical means of nominal concrete 1:3:6 or richer mix (including equivalent design mix) including disposal of material within 50metres lead complete all as specified and directed. |
| 3 | M&L of 62mm thick cement concrete flooring with concrete hardener topping, under layer 50mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kgs of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc., complete all as specified and directed. |
| 4 | M&L for 3mm thick epoxy medium duty flooring of any shade consisting of following: -Preparation of surface by scarifying the concrete surface to remove all oil, grease, paint or any other foreign particles and ensure complete adhesion of the coating to base floor using floor griding with vaccumiser. the concrete surface shall have a rough clean, dust free before application of high compressive strength epoxy flooring complete all as specified and directed. |
| 5 | Providing and applying two component primer CIPOXY 11 (100 microns) of CIPY or equivalent of FOSROC/BASF on the prepared surface by brush / roller covered and sealed evenly on entire surface and allow for 4-5 hours curing. Applying two components CIPOXY-90 (in combination with graded aggregates, offers the highest compressive strength, greater than 100 MPa among the epoxy screed) mortar in the ratio 2:1 and mixed with 2.5 parts of Silica Quartz in a powder mixture to achieve homogenous and applied & levelled by trowelling to form a monolithic layer to a thickness of 1900microns and allow curing for 4-5 hours complete all as specified and directed. |
| 6 | Self leveling EPU top coat with CIPOTHANE SL 1000 of CIPY or equivalent of FOSROC/BASF at a specified ratio and levelled by trowelling to a thickness of 1000 micron and spike roller is applied for de-aeration. The entire top coat has to be dried for 24 hours before loading complete all as specified and directed. |
| 7 | M&L for Yellow or White (Aisle) band 75mm marking with 2 component Polyurethane resin + hardener with fluorescent (FK-666) on applied EPU flooring complete all as specified and directed. |
| 8 | Earth work in excavation for all kind of soil by mechanical means (hydraulic excavator) / manual means over areas including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m complete all as specified and directed. |
| 9 | Moorum / red bajri filling in floors or pavings, laid in layers not exceeding 15cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 10 | M&L for P.C.C with 1:4:8 type D2 (40mm graded stone aggregate) filing in as mass concrete complete all as specified and directed. |
| 11 | M&L for P.C.C with 1:2:4 of 40mm thick using 20mm graded stone aggregate laid as levelling course complete all as specified and directed. |
| 12 | Providing & fixing in position Phenol bonded Bamboo wood flooring with planks of approved sizes 14mm thick, minimum 1800mm length and minimum 100mm wide, in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC). The flooring shall be fixed with tongue and groove interlocking system with wooden moulding and beading were necessary with underlayment of 4mm thick expanded polyethylene foam sheets having density 40 kg/cum, over prepared surface with necessary quarter round planks of size 1900mm x 18mm and door reducer of size 1900mm x 44mm, wherever required. The bamboo wood planks shall have minimum density of 1000 Kg/cum & minimum hardness 1000 Kgf. with ecofriendly UV coating complete all as specified and directed. |
| 13 | Providing and laying joint free glazed vitrified floor tiles polished finish of size 800 x 800mm in floor sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved brand & manufacturer in all colours and shade, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed. |
| 14 | Demolishing brick work manually / by mechanical means built up in In cement mortar including stacking of serviceable material and disposal of unserviceable material within 50metres complete all as specified and directed. |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:4 (1 cement : 4 coarse sand) complete all as specified and directed. |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 as in half brick masonry with in superstructure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:4 (1 cement : 4 coarse sand) complete all as specified and directed. |
| 17 | Providing & fixing in position Phenol bonded Bamboo wood wall cladding at all height with planks of sizes 10mm thick, minimum 1800mm length and minimum 100mm wide in approved colour, texture and finish having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC), with necessary profiled edges fixed with 40mm SS screws 05 Nos in each tile to frame work made of second class teak wood of size 20 x 15mm in centre of each tile and bottom and top of work height, 40 x 15mm placed at ends of each tile with wooden moulding and beading were fixed as required. The cladding shall |
| 18 | be laid over back layment of 4.00mm thick expanded polyethylene foam of density 40kg/cum in two layers, first layer on wall surface before fixing wooden frame and second layer on frame under cladding. The bamboo wood planks shall have minimum density of 1000 Kg/cum & minimum hardness 1000 Kgf. with Eco friendly UV coating complete all as specified and directed. |
| 19 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50metres lead of area 3 sq.metre and below complete all as specified and directed. |
| 20 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50metres lead of area beyond 3 sq.metre complete all as specified and directed. |
| 21 | Providing and fixing factory made uPVC Three track three panels sliding window with two glazed & one wire mesh panels with aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. (02 Nos. glazed panels with double glass pane fittings on each panel for sound proof & one wire mesh panels) made of (big series) using R2 series with frame (70mm & above) x (40mm & above) & both glazed and fly screen sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook and double glazing bead of appropriate dimension. Comprising of lead free uPVC multi-chambered frame, sash and mullion / coupler (wherever required) extruded profiles having minimum wall thickness of 1.70mm Series R1 & R2 profiles and |
| 22 | 2.10mm for Series R3 & R4 profiles conforming to EN:12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (wherever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367:Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded / mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water. |
| 23 | After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / glazing of plain / toughened / laminated / double glass unit with / without high performance coatings as per design requirements and conforming to IS:3548 & IS:16231 shall be paid separately. |
| 24 | Note: Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3.(ii) Sites with structure height more than 20m for all wind speeds. |
| 25 | All as per Sl item No 17 to 17.03 above but two track two panels sliding window with two glazed shutter of aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Sliding window made of using R2 series with frame (40mm & above) x (40mm & above) & sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook and single glazing bead of appropriate dimension complete all as specified and directed.Note for Sl item No 17 &18: For UPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Glass pane and wire mesh rate with silica sealant are also included and size and thickness of glass pane and stainless steel wire gauge to be approved by Engineer-in-Charge. |
| 26 | Providing and fixing M.S. grills of required pattern in frames of windows with M.S. flats, square or round bars including priming coat with approved steel primer fixed to windows by welding complete all as specified and directed. |
| 27 | S&F, venetian blinds of approved make vertical type using 100mm wide fabric blinds of approved colour / shade and pattern including operating arrangement such as chord / thread, counter weight, connecting chain and necessary fittings complete all as specified and directed. |
| 28 | S&F, wooden acoustic door of shutter single / double leaf of 56mm thick achieving sound reduction of upto 50 STC with acoustic polyester infill of 1000GSM and 1 SGL Rbt teakwood frame 120 x 65mm frame profile with anchor fasteners finished with water proof acoustic ply with dampener sheet finished of 2mm thick prelaminate shade finish having 37 STC as per ISO 140 (Part-lll) for door frames and shutters fixed with DORMA SS ball bearing 6\\" x 6\\" x 3mm hinges of 03 No's fitted on each door shutter with steel gaze overhead rack and pinion door closer TS 1000C, EN 2/3 & 4 connected adjustable closing speed with adjustable latching action and one door SS deadlock of 70mm back set and 24mm for end, euro profile cylinder, one side key of 24mm SS strike plate, escutcheons fixed each per door. DORMA |
| 29 | D-Pull handle SS 19 x 300mm to be placed on each door shutter covered with acoustic seal gasket package D50 RMT to be covered for sound proof connected with SS drop down concealed cat of size 911 - 1000mm of each door along with SS concealed tower bolt 300mm long fixed on each shutter. Three side frame and drop seal below will be provided along with the door with high load bearing complete all as specified and directed. |
| 30 | Providing and fixing factory made uPVC white colour casement / casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (wherever required) extruded profiles duly reinforced with 1.60 ± 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels alongwith zinc plated mild steel multi point locking SUB HEAD : 9.0 WOOD AND P.V.C. WORK 210 Code Description Unit Rate No. having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8mm size for fixing frame |
| 31 | to finished wall and necessary stainless steel screws. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality. Single / double glass panes fixed with variation in profile dimension in higher side shall be accepted all complete as per approved drawing & direction of Engineer-in-Charge but no extra payment on this account shall be made casement door with 3D hinges made of (big series) using R4 series with frame (64mm & above) x (55mm & above) & sash (64mm & above) x (100mm & above) both |
| 32 | having wall thickness of 2.3 ± 0.2mm and single glazing bead / double glazing bead of appropriate dimension complete all as specified and directed.Note: For UPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Glass pane and wire mesh rate with silica sealant are also included and size and thickness of glass pane and stainless steel wire gauge to be approved by Engineer-in-Charge. |
| 33 | Dismantling wooden boardings thickness upto 10mm thick boardings in lining of walls and partitions, with supporting members and stackings of complete all as specified and directed. |
| 34 | Supply & installation of synthetic slim, poly fibre panels with core-pigmented, high-density, synth PF rigid panels of size 1200 x 2400 x 9mm thick of volume density 210 - 230kg/m3, weight 1.9 - 2.1kg/m2 having noise absorption, water resistant and thermal insulated. Installed on strut framework system includes each strut of GI frame CC25 Cross Channel having thickness 0.55mm, length 3600mm, knurled web 50, depth 25mm and equal flanges 15mm is fastened to wall positioned horizontally in a regular manner at 600mm c/c. The square edge, magnesite bonded pinewood fibre core tiles of size 600 x 1200 x 20mm, density |
| 35 | 400 kgs/m3, weight 8 kg/m2 are fastened to strut CC25 cross channel with suitable fasteners. Longer edges of the panel should be perpendicular to strut CC25 cross channel. Synth slim panels are then adhered to strand behind with stick S7 adhesive as per design and manufacturer instruction. The system is back lined with the absorb acoustical polyester wool in fill of 25mm thick with 1000 GSM for sound proof complete all as specified and directed by Engineer-in-Charge. |
| 36 | Technical Parameters Fire (Class) - 1 & P, Acoustics - NRC upto 0.9, Thermal conductivity (W/mk) - 0.1, Climate (°C, RH) - 50, 95, Light reflectance (%) - 80, Green (VOC, RC %) - Low, 35 Fire (Class) - B Thermal conductivity (W/mk) - na, Climate (°C, RH) - 50, 99, Light reflectance (%) - Colour Dependent, Green (VoC, RC %) - Nil, 30. |
| 37 | Dismantling cement asbestos or other wooden hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50metres lead complete all as specified and directed. |
| 38 | Supply & installation of Subtex Nubby finished with concealed edge with glass fibre core fully encapsulated ceiling tile of approx size 600 x 600 x 20mm having volume density 120Kgs/m3, weight 2.4kg/m2 which is suspended by using Skelet Trelis T24 Conceal A framework of 0.3mm thick. Skelet Trelis T24 conceal a framework system of 600 x 1200mm module includes. Skelet WA24W30 wall angle with equal flanges of 24mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the Skelet MT24W36 main T with flange width 24mm, height 38mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 600mm centres. |
| 39 | Spacer bar with pre notched slots (Skelet WA24W30 wall angle) at 600mm centers in staggered pattern are placed above Main T24 to hold system in position. Subtex Nubby conceil a edge of size 600 x 600 x 20mm shall be placed into the grid size of 600 x 600mm. Ensure arrow marks behind the tiles are oriented in one direction to achieve uniform shade complete all as specified and directed.Technical Parameters Fire (Class) - 1 & P, Acoustics - NRC 0.9, Thermal conductivity (W/mk) - 0.066, Climate (°C, RH) - 40, 95, Light reflectance (%) - 85, Green (VoC, RC %) - Low, 35. |
| 40 | Supply & installation of Tufbloc HDFR, square edge, magnesia cement core panels of size 1200 x 2400 x 10mm, density 1000kgs/m3, weight 10kg/m2, installed by using strut ceiling framework. The strut ceiling framework system shall include strut WC-25 wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspend strut of GI frame MC45 main channels, fully knurled, sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers with strut SA25, fully knurled, suspender |
| 41 | angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm. Strut CC25 cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mm and equal flanges 9.5mm is fastened to the strut MC45 perpendicularly at 600mm centers. Tufbloc HDFR, 1200 x 2400 x 10mm is installed on the strut CC25 with suitable fasteners in a staggered manner and 4mm gap should be maintained between adjacent Tuf block boards on all sides. The system is back lined with the acoustical polyester infill Synth PF 10 x 25 complete all as specified and directed by Engineer-in-Charge. |
| 42 | Technical Parameters Fire (Class) - 1 & P, STC (12mm-41) -34 to 54, Thermal conductivity (W/mk) - 0.118, Climate (°C, RH) - 50, 95, Light reflectance (%) - Paint dependent, Green (VoC, RC %) - Low, 30 finally finishing with hi gloss acrylic enamel paint painting complete all as specified and directed by Engineer-in-Charge. |
| 43 | Providing and fixing false ceiling at all height of 12.5mm thick tapered edge gypsum moisture resistant board including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x 10 x 0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45 x 15 x 0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick |
| 44 | bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm dia x 230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at |
| 45 | 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer-in-Charge. |
| 46 | Note: The gypsum moisture resistant board must be fixed to the GI frame and joints to be properly filled in with POP paste and paper tape to get a leveled smooth ceiling. Recessing of the gypsum moisture resistant board for light fixtures must be done along with extra frame work of GI sheet section to hold the concealed light fixtures etc., including cost of two coats to give an even shade of 1st quality premium acrylic distemper on ceiling surface over a coat of primer complete with designer ceiling as required and directed by the Engineer-in-Charge. |
| 47 | Dismantling old plaster, skirting raking and dado of wall tiles out joints and cleaning the surface for plaster from brick walls or concrete surfaces including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed. |
| 48 | Rendering 12mm thick cement plaster on ceiling surfaces in cement mortar 1:3 finished fair and even with a floating coat of neat cement of mix complete all as specified and directed. |
| 49 | Rendering 12mm thick in fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth in fine sand complete all as specified and directed. |
| 50 | Rendering 15mm thick in fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth in fine sand complete all as specified and directed. |
| 51 | Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 52 | Form work centering and shuttering including strutting, propping and removal of form for suspended floors, roofs, landings, balconies and access platform, shelves etc; complete all as specified and directed. |
| 53 | Form work centering and shuttering including strutting, propping and removal of form for lintels, beams, plinth beams, girders and bressumers, chajja and cantilever etc; complete all as specified and directed. |
| 54 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level and Thermo-Mechanically Treated bars of grade Fe-500D or more complete all as specified and directed. |
| 55 | M&L for reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand including manufactured sand) : 3 graded stone aggregate 20mm nominal size) complete all as specified and directed. |
| 56 | Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc., complete at all levels of granite stone slab colour black, Cherry / Ruby red area of slab over 0.50 sqm complete all as specified and directed. |
| 57 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing oval shape 450 x 350mm (outer dimensions) complete all as specified and directed. |
| 58 | Providing and fixing cup board shutters with 25mm thick veneered particle board IS:3097 marked, exterior grade (Grade I) of approved make including IInd class teak wood lipping of 25mm wide x 12mm thick with necessary screws and bright finished stainless steel piano hinges with decorative veneering on one side and commercial veneering on other side complete all as specified and directed. |
| 59 | Providing wood work second class teak wood in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) complete all as specified and directed. |
| 60 | S&F, 100mm stainless steel fancy handles for kitchen cabinet complete all as specified and directed. |
| 61 | Providing M.S. piano hinges ISI marked IS:3818 of overall width 35mm finished with nickel plating and fixing with necessary screws etc., complete all as specified and directed. |
| 62 | Providing and fixing special quality chromium plated brass cupboard locks of size 50mm with six levers of approved quality including necessary screws complete all as specified and directed. |
| 63 | Providing and fixing stainless steel pipe for Internal work of 54mm outer dia pipe metre exposed on wall and fitting of grade 316L as per IS-6911:2017 and conforming to EN-10312 standards complete with press type fitting (fitting shall be paid for separately) including fixing of the pipe with clamps at 1.00m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer-in-Charge. (The pipe length inserted in the fitting shall not be measured for payment.) |
| 64 | Providing and fixing required stainless steel fitting for 54mm outer dia pipe each of sleeve / slip coupling / socket press fit design of grade 316L as per IS 6911:2017 and conforming to EN-10312 standards with V-profile and with O-ring sealing gasket of EPDM material of required dia complete all as specified and directed. |
| 65 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections powder coated aluminium (minimum thickness of powder coating 50 micron) and other sections of approved make conforming to IS:733 & IS:1285, fixing frames with dash fasteners of required dia and size including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc., aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge. (Glazing, paneling and dash fasteners to be paid for separately.) |
| 66 | All as per Sl item No 47 above but for shutters of doors, windows & ventilators of powder coated aluminium (minimum thickness of powder coating 50 micron) including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required complete all as specified and directed. |
| 67 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws with pre-laminated particle board with decorative lamination on both sides complete as per architectural drawings complete all as specified and directed. |
| 68 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions with EPDM rubber / neoprene gasket complete as per the architectural drawings and the directions of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item) with float glass panes of 5 to 4.5mm thickness (weight not less than 12.50 kg/sqm) complete all as specified and directed. |
| 69 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS:6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kgs for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate and stainless steel cover plate minimum 1.25mm thickness complete all as specified and directed. |
| 70 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment for the following:- |
| 71 | (a) Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos / Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6mm dia holes at downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed. |
| 72 | (b) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes with Chlorpyriphos / Lindane E.C. 20% with 1% concentration complete all as specified and directed. |
| 73 | (c) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300mm apart including drilling 12mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor with Chlorpyriphos / Lindane E.C. 20% with 1% concentration complete all as specified and directed. |
| 74 | Preparation of new plastered / concrete and ceiling surfaces with 1st quality premium acrylic emulsion paint of interior grade (ready mixed) having VOC content less than 50 gms/litre of approved manufacturer of required shade and colour with two coats applied @1.43 Litre/10 Sqm including priming coat of primer applied @ 0.90 Litre/10 Sqm on new work complete as per manufacturer's specification over including 1mm thick internal wall care putty finish complete colour & shade complete all as specified and directed. |
| 75 | Removing white or colour wash and any existing treatment by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches, Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth and Applying one coat of water thinnable cement primer having VOC content less than 50 gram/litres of approved brand and manufacture on wall surface complete all as specified and directed. |
| 76 | Wall painting on old work with 1st quality premium acrylic emulsion paint of interior grade two coats having VOC (Volatile Organic Compound) content less than 50 grams/litre of approved brand and manufacture including applying additional coats wherever required to achieve even shade and colour complete colour & shade complete all as specified and directed. |
| 77 | Finishing walls with all weather proof exterior paints with high durability and performance with elastomeric properties of having Silicone additives of required shade old work (two coats applied @ 1.43 ltr/10 sqm) over existing cement paint surface complete colour & shade complete all as specified and directed. |
| 78 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two coats on new work for steel and wooden surfaces over an under coat of suitable shade with ordinary paint of approved brand and manufacture of complete all as specified and directed. |
| 79 | Demolition of cement concrete in roof surface including removal of old tarfelt, plastering, concrete mugs etc; upto the original RCC roof level complete all as specified and directed. |
| 80 | Providing and laying levelling course 30mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources) including smooth finished surface complete all as specified and directed. |
| 81 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification cement complete all as specified and directed. |
| 82 | Material and labour for roof treatment as follows:-(a) M&L for chipped out the existing loose bitumen membrane surface, clean the surface thoroughly to make it smooth and clean of any foreign materials, repair the concrete wherever damaged using PMM HS repair, repairing of constructions / cracks / chasing with machine and fill the same with Polymerised Motor in HS repair, coping of 75 x 75mm should be made at the junction of wall and raft slab using polymerised cement mortar 1:4 add mixed with advance latex plus.(b) Applying one coat of 50% diluted self priming PU roof coat. Allow to dry priming coat for 4 to 6 hrs before applying PU coats and surface to be cleaned before applying PU coats. |
| 83 | (c) Applying two coats of single component cold applied, water based polyurethane modified acrylic dispersion with highly elastic and UV resistant water proofing treatment to the roof with HS PU roof coat of Berger or equivalent at 0.6Kg/sqm for each coat without dilution confirming to ASTM D 6083-97a (Standard specification for liquid applied acrylic coating used in roofing) each coat should allow to dry 4 to 6 hrs the components shall have a density of 1.5 to 1.3 Kg/ltrs having tensile strength of 1.5 N/mm2 having elongation of 350% with solid content not less 60% in two coats. SRI value should be more than 100. |
| 84 | The coated rate shall include surface preparation, repair the cracks in mother slab by chasing with cutting machine and filled the same with polymerised motor in CM 1:4 admixed with latex agent of reputed manufacturers, making coving at junction, bore packing, treatment of construction joints completely as per manufacturers specification and complete all as specified and directed.Note: The above treatment shall be got carried out by the authorised applicator of the manufacturer approved by the Engineer-in-Charge. |
| 85 | Supply, installation & providing in repair of built in auditorium Tip-up recline chair of center to center 588mm, 1100mm height, plywood (hardwood) with induction heating and high pressure pressed. ABS moulded housing for seat & back cushions, armrest made of PP/PPCP/ABS or semi rigid PU foam, Polyurethane injection moulded flexible foam seat and back density 50-55 Kg/m3, Fabric to be 100% polyester synthetic fabric with 4mm Polyurethane foam lamination. Fire retardant standard ISO 3795, FMVVSS302, Water repellent- standard-AATCC193 Torsion spring / spring steel IS:445411 Grade lll. HRCA/CRCA sheet metal IS:1097-1994, |
| 86 | Electrostatic epoxy powder coating thickness : 70-80 micron. Seat numbering at side of the flooring LED lights in sides alongwith aisles. The chairs should be installed to the flooring with the anchor fasteners 12mm x 100mm pin type. Fabric colour to customer choice. Chair frame shall be up of metal or wood complete all as directed by Engineer-in-Charge. |
| 87 | Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors complete all as specified and directed. |
| 88 | M&L for wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required complete all as specified and directed. |
| 89 | M&L for Wiring for twin control light point with with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch (2 way), modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable as required complete all as specified and directed. |
| 90 | S&F, suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections as required complete all as specified and directed. |
| 91 | S&F, suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections as required complete all as specified and directed. |
| 92 | S&F, 3 pin, 5 A ceiling rose on the existing junction box / wooden block including connections as required complete all as specified and directed. |
| 93 | S&F, call bell / buzzer suitable for single phase, 230 V, complete as required complete all as specified and directed. |
| 94 | Taking down old submain wiring including copper / aluminium / GI earth continuity conductor including sockets 5/15 Amps, industrial plug & socket all connected accessories and making good disturbed surfaces of any size complete all as specified and directed. |
| 95 | M&L for wiring for circuit / submain wiring alongwith earth wire with the 2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required for power sockets complete all as specified and directed. |
| 96 | M&L for Wiring for circuit / submain wiring alongwith earth wire with the 2 x 4 sq.mm + 1 x 4 sq.mm earth wire FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required of size complete all as specified and directed.Note for Sl item No 71 & 72: Three runs of cable and one run of conduit and conduit accessoriesshall be measured as one unit. |
| 97 | S&F, two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate as required complete all as specified and directed. |
| 98 | S&F, modular blanking plate on the existing modular plate & switch box excluding modular plate as required complete all as specified and directed. |
| 99 | S&F suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, 'C' curve including connections, painting as required complete all as specified and directed. |
| 100 | Supplying, installation, testing & commissioning of LED surface mounted Batten light(system lumen efficacy ≥120 <135 lm/Watt) of CRCA sheet body (thickness > 0.50mm) of capacity 22 watts as per IS:10322 with driver (Replaceable) as per the requirement (<700ma) with driver efficiency >85%, operating voltage AC 140-270 Volt, frequency 50/60 hz, operating temperature range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with short & open circuit protection, THD<10%, P.F. ≥0.95, IP20, CRI>80, UGR (Unified Glare Rating) <19, flicker free (flicker should be below 5%), life time (LED, driver & electrical circuitry), life time of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends, |
| 101 | CCT3000°K / 4000°K / 5700°K / 6000°K / 6500°K (as per ANSIB in), SDCM (Standard Deviation Color Matching) <5, maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trademark certificate (T.C.). Manufactures Word Mark / Name Engraved / Embossing / Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures complete in all respect / connections with |
| 102 | 1.5 sqmm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with minimum 05 years OEM warranty. System lumen efficacy ≥120<135lm/Watt output LM 79 & LM 80 test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C.) |
| 103 | Supplying, installation, testing & commissioning of LED surface mounted batten light(system lumen efficacy ≥120 <135 lm/Watt) of CRCA sheet body (thickness > 0.50mm) of capacity 36 watts as per IS:10322 with driver (Replaceable) as per the requirement (<700ma) with driver efficiency >85%, operating voltage AC 140-270 Volt, frequency 50/60 hz, operating temperature range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with short & open circuit protection, THD<10%, P.F.≥0.95, IP20, CRI>80, UGR (Unified Glare Rating) <19, flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 burning Hours with 70% |
| 104 | of initial Lumen maintained till life ends, CCT3000°K / 4000°K / 5700°K / 6000°K / 6500°K (as per ANSIB in), SDCM (Standard Deviation Color Matching) <5, maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard and trademark certificate (T.C.). Manufactures Word Mark / Name Engraved / Embossing / Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect / connections with 1.5 sqmm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with minimum 05 years OEM warranty. System lumen efficacy ≥120<135lm/Watt out put. LM 79 & LM 80 test report from NABL lab for all testing |
| 105 | required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C.) |
| 106 | Supplying, installation, testing & commissioning of 40 watt street light LED fixture powder coated pressure die cast aluminium body(system lumen efficacy ≥105<120lm/Watt) with driver as per the requirement (<700ma), Input voltage: 140-270 Volt AC, frequency 50/60 hz, operating temperature range -15 deg to 50 deg centigrade, internal surge protection of 5 KVL, N, E as per IEC 61000 -4 -5, Driver |
| 107 | efficiency >85%, THD<10% as per IEC 61000 -3 -2, P.F. ≥0.95, IP-66, IK-08, CRI>80, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA Type I/II/III as per the width of the road and the project requirement, suitable to fit in upto 65mm dia pipe, life time of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends as per LM80 extra polation IESTM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (as per ANSIB in), maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard complete in all respect / connections with 1.5 sqmm FRLS, PVC insulated copper conductor single core cable and earthing as required |
| 108 | with minimum 05 years OEM warranty. System lumen efficacy ≥105<120lm/Watt output. LM 79 & LM 80 test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C.) |
| 109 | Supplying, installation, testing & commissioning of panel light 2x2 ft.(System lumen efficacy ≥120 <135 lm/Watt) of CRCA sheet body (thickness > 0.50mm) of capacity 40 W as per IS: 10322 with driver as per the requirement (< 700ma) with driver efficiency >85%, operating voltage AC 140-270 Volt, frequency 50/60hz, operating temperature range-15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with short & open circuit protection, THD<10%, P.F.≥0.95, IP20, CRI>80, UGR (Unified |
| 110 | Glare Rating) <19, Flicker free, (flicker should be below 5%), life time (LED, driver & electrical circuitry), life time of minimum 50000 burning hours with 70% of initial Lumen maintained till if ends, CCT3000°K / 4000°K / 5700°K / 6000°K / 6500°K (as per ANSIB in), SDCM (Standard Deviation Color Matching) <5, maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark / Name Engraved / Embossing / Screen printing on housing complete in all respect / connections with 1.5 sqmm FRLS, PVC |
| 111 | insulated copper conductor single core cable and earthing as required with minimum 05 years OEM warranty. System lumen efficacy ≥120<135lm/Watt output. LM 79 & LM 80 test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C.) |
| 112 | Supplying, installation, testing & commissioning of panel light 2x2 ft.(System lumen efficacy ≥120 <135 lm/Watt) of CRCA sheet body (thickness > 0.50mm) of capacity 36 W as per IS: 10322 with driver as per the requirement (< 700ma) with driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60hz, operating temprange-15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with short & open circuit protection, THD<10%, P.F.≥0.95, IP20, CRI>80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5%), life time (LED, driver & electrical circuitry), life time of minimum 50000 burning hours with 70% of initial Lumen maintained till if ends, |
| 113 | CCT3000°K / 4000°K / 5700°K / 6000°K / 6500°K (as per ANSIB in), SDCM (Standard Deviation Color Matching) <5, maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark / Name Engraved / Embossing / Screen printing on housing complete in all respect / connections with 1.5 sqmm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with minimum 05 years OEM warranty. System lumen efficacy ≥120<135lm/Watt output. LM 79 & LM 80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per |
| 114 | requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C.) |
| 115 | Supplying, installation, testing & commissioning of 30 watt LED recessed / surface down lighter(system lumen efficacy ≥120 <135 lm/Watt) (round / square / rectangular of following body material and construction as per IS:10322 with driver as per the requirement (<700ma) with driver efficiency >85%, operating voltage AC 140-270 Volt, frequency 50/60 hz, operating temperature -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with short & open circuit protection, THD<10%, P.F.≥0.95, IP20, CRI>80, UGR (Unified Glare Rating) <19, Flicker free (flickers should be below 5%), life time (LED, driver & electrical circuitry), life time of minimum 50000 burning hours with 70% of initial |
| 116 | Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (as per ANSIB in), SDCM (Standard Deviation Color Matching) <5, maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark / Name Engraved / Embossing / Screen printing on housing. OEM must have it sown in house NABL lab setup for all testing facilities for LED fixtures complete in all respect / connections with 1.5 sqmm FRLS, PVC insulated copper conductor single core cable and earthing as required with minimum 05 years OEM warranty. System lumen efficacy ≥120<135lm/Watt output. LM 79 & LM 80 test report from NABL lab for all testing |
| 117 | required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C.) |
| 118 | Supplying, installation, testing & commissioning of LED flood light, powder coated pressure die cast aluminium body(system lumen efficacy ≥120 & <135 lm/Watt) with built in or separate driver as per the requirement (<700ma), capacity 50 W, voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, operating temprange-15 deg to 50 deg centigrade, internal surge protection of 5 KVL,N,E as per IEC 61000-4-5, driver efficiency >85%, THD<10% as per IEC 61000-3-2, P.F.≥0.95, IP-66, IK-08, CRI>80, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120 deg as per the application and the project requirement deg, suitable tiltable fitting, life |
| 119 | time of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends as per LM 80 extra polation IESTM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (as per ANSIB in), maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard complete in all respect / connections with 1.5 sqmm FRLS, PVC insulated copper conductor single core cable and earthing as required with minimum 05 years OEM warranty. System lumen efficacy ≥120 and |
| 120 | <135lm/Watt output. LM 79 & LM 80 test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heatsink of aluminium housing such that LED junction temperature shall not rise above 90°C.) |
| 121 | Taking down carefully MCB DBs / MCCB DBs with MCBs / MCCBs of any type any size complete all as specified and directed. |
| 122 | S&F surface / recess mounting, vertical type, 415 V, TPN MCB (VTPN) distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required of size 4 way (4+12), double door complete all as specified and directed. |
| 123 | S&F, single pole and neutral, sheet steel, MCB distribution board, 240 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (but without MCB / RCCB / Isolator) 16 way, double door complete all as specified and directed. |
| 124 | S&F surface / recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required of size 8 way (4 + 24), double door complete all as specified and directed. |
| 125 | S&F, 5 A to 32 A rating, 240/415 V, 10 kA, 'C' curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing & commissioning as required complete all as specified and directed. |
| 126 | S&F, single pole blanking plate in the existing MCB DB as required complete all as specified and directed. |
| 127 | S&F, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning as required of size 40 A complete all as specified and directed. |
| 128 | S&F, single pole neutral 5 A to 32 A rating, 240/415 V, 10kA, 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning as required complete all as specified and directed. |
| 129 | S&F, four pole, 415 V, MCB/MCCB 16 KA in the existing MCB DB complete with connections, testing and commissioning as required of size 100A complete all as specified and directed. |
| 130 | S&F, four pole, (three phase and neutral), 415 volts, Residual Current Circuit Breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc., as required of size 63 A complete all as specified and directed. |
| 131 | Taking down the sub main wiring of any size from the wall / roof / ceiling and removing from the site and making good disturbed surface complete all as specified and directed. |
| 132 | Wiring for circuit / submain wiring alongwith earth wire 2 x 6sq.mm + 1 x 6 sq.mm of size FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed.Note: Three runs of cable and one run of conduit and conduit accessoriesshall be measured as one unit. |
| 133 | Wiring for circuit / submain wiring alongwith earth wire 4 x 10sq.mm + 2 x 6 sq.mm of size FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed. |
| 134 | Wiring for circuit / submain wiring alongwith earth wire 4 x 16sq.mm + 2 x 6 sq.mm of size FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed.Note for Sl item No 95 & 96: Six runs of cable and one run of conduit and conduit accessories shall be measured as one unit. |
| 135 | Supplying and installing of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders of size 200mm width x 50mm depth x 1.6mm thickness including taking down the old one complete all as specified and directed. |
| 136 | S&F, repairs in LAN sockets with box modular type including taking down the old one complete all as specified and directed. |
| 137 | S&F, repairs in LAN cable with terminal connections casing caping / PVC conduit including taking down the old one complete all as specified and directed. |
| 138 | S&F, PVC conduit medium grade of size 20mm alongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed. |
| 139 | M&L for disconnecting the split AC 1.5/2.0 ton capacity and refixing the same to the specified location after completion of all the civil works with necessary bracket, copper pipes and control copper wiring upto 5m, insulation materials, refrigerant gas top up and testing complete all as specified and directed. |
| 140 | Taking down fan, sealing cable end, dismantling blades and removing fan andblades to store complete all as specified and directed. |
| 141 | Painting of ceiling fan / wall mounting fan in installed position with one coat of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent as required complete all as specified and directed. |
| 142 | Installation, testing & commissioning of existing ceiling fan including wiring the down rods of standard length (upto 30cm) with 1.5 sq.mm FRLS/HFFR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box as required complete all as specified and directed. |
| 143 | Installation, testing & commissioning of existing wall mounting fan including wiring with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box as required complete all as specified and directed. |
| 144 | Installation, testing & commissioning of existing exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning as required upto 450mm sweep complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail