| 1 | Excavation in trenches n.exc 1.5m wide and n.exc1.5 m in depth for foundation, or shafts, wells, cess pits manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in any type of soil / rock (soft / hard / dense soil /rock) complete all as specified and directed by Engr-in-charge. |
| 2 | Excavation in trenches n.exc 1.5m wide and exc1.5 m in but n. exc 3.0m depth for foundation, or shafts, wells, cess pits manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in any type of soil / rock (soft / hard / dense soil /rock) complete all as specified and directed by Engr-in-charge. |
| 3 | M & L for Returning & filling in including spreading, levelling, watering & well ramming in layers n.exc 25mm thick in soft/ hard / dense soil complete all as specified and directed by Engineer-in-charge. |
| 4 | Removing surplus excavated material out side MOD land complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L for PCC 1:4:8 type D2,(using 40mm graded stone aggregates) as in foundation,filling and mass concrete all as specified and directed. |
| 6 | S & F SAIL MS hot rolled sheet plate 06mm thick for wall and floor including all necessary welding, drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-charge. |
| 7 | S & F SAIL MS hot rolled sheet plate 12mm thick for Roof including all necessary welding, drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-charge. |
| 8 | S&F MS rectangular hollow steel section of size 90x38x2.65mm thick for frame stucture including all necessary welding, drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-charge. |
| 9 | S7F 200mm length Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed by Engineer-in-charge. |
| 10 | M&L for two coats synthetic enamel paint over a coat of red oxide primer on steel surfaces of any description not otherwise described over 10 cm width or girth including preparation of surfaces complete all as specified and directed by Engineer-in-charge. |
| 11 | M&L for two coats black bituminus paint over a coat of red oxide primer on steel surfaces of any description not otherwise described over 10 cm width or girth including preparation of surfaces complete all as specified and directed by Engineer-in-charge. |
| 12 | S&F Anti skid PVC floor mat 5mm rubber sheet with fabric backing or insert and with with ribbed or fluted topping for flooring complete all as specified and directed by Engineer-in-charge. |
| 13 | S&F 25mm thick Bonded mineral wool blankets slab made from rock, density 48 kg/cum and fixed as per manufacturer’s instructions and one side of blanket/ slab (of any thickness) is covered with polythene based jute hessian cloth complete all as specified and directed by Engineer-in-charge. |
| 14 | S&F 12mm thick Perforated particle board/ tiles for insula-tion and accoustic purposes, 60x60 cm in size, fixed with screw to timber frame work or with staples on snap grid complete all as specified and directed by Engineer-in-charge. |
| 15 | Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. Complete all as specified and directed. |
| 16 | M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC casing caping for point wiring with PVC casing caping, modular sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with modular inner and outer cover sheets of required colour complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex /KEI/Polycab ] |
| 17 | One light / Fan / Exhaust fan point controlled by one switch |
| 18 | One 5 pin 5 Amp switch socket out let point on an independent board |
| 19 | One 5 pin 5 Amp switch socket out let point on an same board |
| 20 | M&L for point wiring complete with PVC insulated and unsheathed cable 4.0 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC casing caping for point wiring with PVC casing caping, modular sunken boxes not less than 1.6mm thick of reqd size (factory painted) and modular inner and outer cover sheets of required colour complete including 4.0 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex /KEI/Polycab ] |
| 21 | S&F Modular switch piano, flush type, 5 amps single pole, one way |
| 22 | S&F Modular switch piano, flush type, 16 amps single pole, one way |
| 23 | S&F Modular socket, flush type, 5 pin, 16 amp multi purpose. |
| 24 | S&F Modular socket 2 in 1, 3 pin, 5 and 5 Amps flush type. |
| 25 | S&F Modular light dimmer 450W switch Make Anchor 65401 Penta |
| 26 | Supply and fixing of LED lights fitting 24 Watt LED 6500K, 220V,AC decorative ultra slim square profile LED lighting fixture, dimmable, tunable, minimum 100 Lumen / watt with extruded polycarbonate environmental friendly energy, with driver, holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.Make :Bajaj/wipro/philips |
| 27 | Supply and fixing of steel body roof exhaust fan, 1500 CFM adjustable speed control attic vent fan with high speed motor AC single Phase. 230V speed 8 km /hr, IP 68 with aluminium frame and complkete connection from room to ventilator complete all as specified and as directed |
| 28 | Supply and fixing of steel body wall mounted fan, BLDC motor AC single Phase. 230V with ventilator of metal body, 1325 RPM, thermal overload protection, up and down tiltiable, minimum air delivery 110 CMM of size 450m sweep with, blades, frame and wall mounting accessories complete all as specified and as directed. |
| 29 | M&L of TPN three phase distribution board, 4 way 440 volts having IP-54 isolated busbar assembly IK 09 Mechnical impact strength door earthing protection, double door with provision for fixing of MCCBs as incomer up to 63 Amps and MCBs as outgoing complete all as specified and as directed .(Make: Indoasian or its equivalent/legrand /CG ) |
| 30 | Supply and fix of MCCB 4P 63 Amps having breaking capacity 25 KA with complete all accessories all as specified and as directed |
| 31 | M&L MCB SPN 32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. |
| 32 | M&L MCB SP 6-32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. |
| 33 | Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using copper earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion. |
| 34 | Supply and fixing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, of size 25 sqmm 4 core laid in trenches or passing through pips/ ducts complete all as specified and directed by Engineer in charge |
| 35 | Supply and fixing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor,1100 volts grade, of size 35 sqmm 3.5 core laid in trenches or passing through pipes complete all as specified and directed by Engineer in charge |
| 36 | M & L for Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. by Engineer-in-Charge. |
| 37 | M&LCommon burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other complete all as specified and directed for cable protection. |
| 38 | Supply and fixing of Earth continuity conductor or main 4 mm Galvanised iron wire fixed to wall on batten or recess or chases including or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and as directed |
| 39 | S & F HDPE of size 80 mm with all fittings laid in trenches or fixed to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable complete all as specified and directed by Engr in charge. |
| 40 | Cutting of road (in hard/ dense soil) for laying cable line of any size upto 0.50 mtr. depth and 0.3 m width and getting out including forming bottom surface to required level and making good the road/wall as per existing concrete with 1:3:6 PCC complete all as specified and directed by Engineer-in-Charge |
| 41 | S & F HDPE of size 50 mm with all fittings laid in trenches or fixed to walls and ceiling or laid in floor for cable after laying of cable complete all as specified and directed by Engr in charge. Please Enable Macros to View BoQ information |
| 42 | S & F HDPE of size 50 mm with all fittings laid in trenches or fixed to walls and ceiling or laid in floor for cable after laying of cable complete all as specified and directed by Engr in charge. Please Enable Macros to View BoQ information |