| 1 | M&L Preparation of plastered or unplastered old decorated surfaces of walls including filling of cracks with approved crack filler and applying one coat of white wash complete all as specified and directed. Note: Wall, Roof hight portion upto ht 7.50m incl necessary scaffolding to be provided complete all as specified and directed. |
| 2 | All as per item No. 1 above but one coat of white wash on ceiling surfaces including filling of cracks with approved crack filler complete all as specified and directed. Note: Wall, Roof hight portion upto ht 7.50m incl necessary scaffolding to be provided complete all as specified and directed. |
| 3 | M&L Preparation of plastered or unplastered old surfaces of ceiling and applying one coat of oil bound distemper including filling of cracks with approved crack fillercomplete all as specified and directed. Note: Wall, Roof hight portion upto ht 7.50m incl necessary scaffolding to be provided complete all as specified and directed. |
| 4 | M&L Preparation of plastered or unplastered stopping of distempered surfaces of walls including filling of cracks with approved crack filler and applying one coat of OBD white/ coloured complete all as specified and directed. Note : Oil bound distemper will be done by roller only, after complete removal of old loose flakes. Wall, Roof hight portion upto ht 7.50m incl necessary scaffolding to be provided complete all as specified and directed. |
| 5 | M&L complete removal of existing treatment on wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed. Note: Wall, Roof hight portion upto ht 7.50m incl necessary scaffolding to be provided complete all as specified and directed. |
| 6 | Material and labour for complete removal of existing treatment on wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over 1 mm thick wall care putty complete all as specified and directed.Note : Oil bound distemper will be done by roller only, after complete removal of old loose flakes and Wall, Roof hight portion upto ht 7.50m incl necessary scaffolding to be provided complete all as specified and directed. |
| 7 | Material and labour for applying one coat of exterior emulsion paint (weather proof) on old treated wall surfaces complete all as specified and directed. Make :APEX ULTIMA of Asian Paint or equavalent Note : APEX ULTIMA paint will be done by roller only, after complete removal of old loose flakes complete all as specified and directed. Note: Wall, Roof hight portion upto ht 15m incl necessary scaffolding to be provided complete all as specified and directed. |
| 8 | Material and labour for complete removal of existing treatment, preparation of surfaces of wall and applying two coats of exterior emultion weather proof paint over a coat of primer complete all as specified and directed. Make :APEX ULTIMA of Asian Paint or equavalent. Note : APEX ULTIMA paint will be done by spray only, after complete removal of old loose flakes and wall, roof hight portion upto ht 7.50m incl necessary scaffolding to be provided complete all as specified and directed. |
| 9 | M&L for uprooting of wild trees such as grass/bushes etc from the roof / wall surfaces / AC sheets/soil pipes surrounding including its penetrated roots with suitable cleaning chemical and making good to the damaged plaster by providing CM 1:3 and finish the surfaces to match with the existing surface complete all as specified and as directed. Note: Wall, Roof hight portion upto ht 15m incl necessary scaffolding to be provided complete all as specified and directed. |
| 10 | Material and labour for preparation of old surfaces of walls and applying one coat of cement based paint including external scaffolding work including filling of cracks with approved crack fillercomplete all as specified and directed. Note : cement based paint will be done by roller only, after complete removal of old loose flakes and wall, roof hight portion upto ht 7.50m incl necessary scaffolding to be provided complete all as specified and directed. |
| 11 | Material and labour for complete removal of existing treatment, preparation of surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed. Note : cement based paint will be done by roller only, after complete removal of old loose flakes and wall, roof hight portion upto ht 7.50m incl necessary scaffolding to be provided complete all as specified and directed. |
| 12 | M&L Preparation of old painted wooden surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. Note: Hight portion upto ht 7.50m incl necessary scaffolding to be provided complete all as specified and directed. |
| 13 | M&L Preparation of old painted wooden surfaces of Ceiling any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. Note : Roof hight portion upto ht 7.50m incl necessary scaffolding to be provided complete all as specified and directed. |
| 14 | M&L Preparation of old painted steel surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. Note : Hight portion upto ht 7.50m incl necessary scaffolding to be provided complete all as specified and directed. |
| 15 | M&L Filling cracks with polymer based chemical (Dr fixit cracks shrink free ) for cracks not exc 10 mm in width on wall surfaces or concrete or masonary surfaces as per manufacturer instructions including necessary arrangement of scaffolding etc complete all as specified and directed. Make:- Dr fixit /Berger / Perma complete all as specified and directed. |
| 16 | S & F Aluminium anodised (minimum anodisation is 50 microns) Door / window / Ventilator/partition Sliding /Arch type cover with glass and openable type frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc complete with standard aluminium sections, complete all as specified and directed. (Aluminium section shall be of make Jindal/Hindalco/ Indalco). Note:- (i) Weight of various Aluminium sections handles and locking arrangements shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. Glass panels, prelaminated particle boards, aluminium wire cloth as applicable will be measured and paid separately as supplied only. (ii) If any requirment dismantling/cutting of existing steel windows/ventilators with help of Gas cutter and make good and match with existing walls at any hight complete all as specified and directed by Engr-in-charge. (iii) Hight portion upto ht 7.50m incl necessary scaffolding to be provided. |
| 17 | S&F for sheet glass ordinary quality 4 mm thick fitted with beading/putty n.exc 0.5 sqm each with wooden/steel beads, sheet glass is ground or obscured or frosted including hacking out glass and fixed complete all as specified and directed. |
| 18 | S & F fixed in repairs galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with galvanised wire staples/screw in wooden/ steel frame of doors and windows. complete all as specified and directed. |
| 19 | S&F in rep door closure hydraulically regulated disignatin No 2 universal type suitablefor door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and directed. |
| 20 | M&L rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces of walls including finished even and smooth without using extra cement including Taking down cement plaster from brick or stone walls, ceiling etc complete all as specified and directed. |
| 21 | M&L for rendering 5 mm thick on ceiling in CM 1:3 finished even and smooth without using extra cement including Taking down cement plaster from brick or stone walls, ceiling etc complete all as specified and directed. |
| 22 | M&L rendering 15mm thick in CM (1:4) with water proofing compound on fair faces of brick work or concrete surfaces of walls finished even and smooth without using extra cement including Taking down cement plaster from brick or stone walls, ceiling etc complete all as specified and directed. |
| 23 | M&L preparation of new plastered surfaces and applying two coats of weather proof exterior emulsion paint (APEX ULTIMA of Asian Paints or equivalent of Berger/Nerolac) over a coat of primer complete all as specified and directed. |
| 24 | M&L for preparing new plastered surfaces of wall and applying two coats of oil bound distemper over 1 mm thick wall care putty and a coat of alkali resistant primer complete all as specified and directed. |
| 25 | M&L preparation of new plastered surfaces and applying three coats of white wash on ceiling surface complete all as specified and directed. |
| 26 | Taking down AC/PVC pipes of any description any pattern incl all fittings heads, shoes bends etc complete all as specified and directed Note : height up to 15m |
| 27 | S&F PVC (SWR) pipes of 110mm dia single socketed in any length including all fittings with rubber ring joints fixed to walls or in floors complete all as specified and directed. Note : height up to 15m |
| 28 | S&F PVC (SWR) pipes of 75mm dia single socketed in any length including all fittings with rubber ring joints fixed to walls or laid in trenches or in floors complete all as specified and directed.. Note : height up to 15m |
| 29 | S&F PVC (SWR) bends 110mm dia any radius complete all as specified and directed. |
| 30 | S&F PVC (SWR) bends 75mm dia any radius complete all as specified and directed. |
| 31 | S&F PVC (SWR) bends with access door 110mm dia any radius complete all as specified and directed. |
| 32 | S&F PVC (SWR) bends with access door 75mm dia any radius complete all as specified and directed. Please Enable Macros to View BoQ information |