| 1 | Dismantling plain or corrugated steel sheeting, with ridge, gutters, etc, any gauge, and thickness incl Nainital pattern roof covering, fixed with J/L hooks or coach screws complete all as specified and directed.Note: The work is required to be carried out in upto 10m height, contractor will make arrangement for scaffolding and other necessary T&P etc. Adequate arrangement for safety and security of labours shall be made by contractor and the cost of all above shall deemed to be included in the rates quoted by the contractor and nothing extra shall be admissible. |
| 2 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws, complete all as specified and directed. Note: The work is required to be carried out in upto 10m height, contractor will make arrangement for scaffolding and other necessary T&P etc. Adequate arrangement for safety and security of labours shall be made by contractor and the cost of all above shall deemed to be included in the rates quoted by the contractor and nothing extra shall be admissible. |
| 3 | S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/clading to wall,eaves board fixed with self tapping screws, complete all as specified and directed.Note: The work is required to be carried out in upto 10m height, contractor will make arrangement for scaffolding and other necessary T&P etc. Adequate arrangement for safety and security of labours shall be made by contractor and the cost of all above shall deemed to be included in the rates quoted by the contractor and nothing extra shall be admissible. |
| 4 | S&F Plain, galvanised, mild steel sheeting of thickness 1mm as in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 and joints are welded or soldered complete all as specified and directed. Note: The work is required to be carried out in upto 10m height, contractor will make arrangement for scaffolding and other necessary T&P etc. Adequate arrangement for safety and security of labours shall be made by contractor and the cost of all above shall deemed to be included in the rates quoted by the contractor and nothing extra shall be admissible. |
| 5 | S&F fibre glass reinforced translucent corrugated sheeting 2mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc and sides filled with silicone sealant of make Dr fixit or equivalent complete all as specified and directed. |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided, complete all as specified and directed. |
| 7 | Dismantling timber scantlings, framed/ unframed work of size 40 sqcm and over in section in any position in any position with nails etc., complete all as specified and directed. |
| 8 | Dismantling timber scantlings framed work in fillets, frame work of cup board, rails, posts, rafters, purlins, battens etc under 40 sq cm in section in any position with nails etc., complete all as specified and directed. |
| 9 | S&F roof trusses, purlins, posts, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel, flat, tubular sections) including distance pieces cleats Fe 410-W(Gde-E- 250) quality-A etc complete for fixing roof sheets/ claddings and other similar works as per requirement, complete all as specified and directed. |
| 10 | S&F framed work such as grills, gratings, etc., incl for ornamental and intricate design ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barrier iron doors, ladder, framed baluster, walk ways, railing, framework of watertanks staging and similar work conforming to Fe-290, Gde-E-165, complete all as specified and directed. |
| 11 | M&L for second class hard-wood wrought timber as in scantlings as in struts, tie beams rafters, etc. framed and fixed complete all as specified and directed. |
| 12 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth etc not exceeding 10 Sqm on plan for shafts, cesspits, manholes, pier holes, foundation etc and getting out in hard/dense type of soil complete all as specified and directed. |
| 13 | Returning filling in and including spreading levelling, watering and well ramming in layers exc 25 cm thick complete all as specified and directed. |
| 14 | Removing excavated material exceeding 500m and depositing outside MoD Land where directed at a level not exceeding 1.5m above the starting point, soil complete all as specified and directed. |
| 15 | M&L for PCC 1:4:8, type D-2, using 40mm graded crushed stone aggregate foundations, filling and mass concrete complete all as specified and directed. |
| 16 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed. |
| 17 | M&L for RCC foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete uing type 25 (Design mix) (using 20mm graded) stone aggregate, complete all as specified and directed. |
| 18 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and directed. |
| 19 | M&L for RCC in Columns, pillars, piers, posts and struts uing type M-25 (Design mix) (using 20mm graded) stone aggregate complete all as specified and directed. |
| 20 | Form work to sides of concrete roof beams, lintels cantilevers etc including supports, complete all as specified and directed. |
| 21 | M&L for RCC in beams, Cantilivers, bressummers, lintels over 1.5 mtr span uing type 25(Design mix) (using 20mm graded) stone aggregate |
| 22 | M&L for mild steel TMT bars 10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality, complete all as specified and directed. |
| 23 | All as per srl item No 22.00 above but for 6 to 10mm dia bars as in stirrups spacers and binders complete all as specified and directed. |
| 24 | Taking down chowkhats or frames with shutters n.exc 1.5 sqm each (without taking off shutters from the frame) and removing from site all as directed. |
| 25 | All as per srl item No 24.00 above but exc 1.5 sqm but n.exc 4sqm each complete all as specified and directed. Please Enable Macros to View BoQ information |
| 26 | All as per srl item No 24.00 above but exc 1.5 sqm but n.exc 4sqm each complete all as specified and directed. Please Enable Macros to View BoQ information |