| Sl. No. | Item Description |
| 1 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or salimar pattern roof coverings, complete all as specified and as directed. |
| 2 | Supply & Installation Pre-painted, High Tensile 550 Mpa yield strength, Bare Galvalume Steel Sheet having maximum pitch of 250mm c/c & minimum 30mm crest depth in length as per site requirement. The galvalume sheet is to be manufactured out of 0.50mm (TCT) (Total Coated Thickness), with zinc-aluminium alloy of AZ-150. The GI based steel sheet shall have a hot dip metallic zinc-aluminium alloy coating of zinc (43.5%), aluminium (55%) & Silicon (1.5%). The profile is having return leg for proper side lap. The sheet shall be fixed using self Drilling/Self Tapping Screw with EPDM Seal Complete all as per manufacturers specifications, complete all as specified and as directed. |
| 3 | Supply & Installation Pre-painted, High Tensile 550 Mpa yield strength, Bare Galvalume plain Steel Sheet. The galvalume sheet is to be manufactured out of 0.50mm (TCT) (Total Coated Thickness), with zinc-aluminium alloy of AZ-150. The GI based steel sheet shall have a hot dip metallic zinc-aluminium alloy coating of zinc (43.5%), aluminium (55%) & Silicon (1.5%). The profile is having return leg for proper side lap. The sheet shall be fixed using self Drilling/Self Tapping Screw with EPDM Seal Complete all as per manufacturers specifications, complete all as specified and as directed. |
| 4 | Dismantling wrought iron or mild steel work of any description, complete all as specified and as directed. |
| 5 | S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410-W (Gde 250 quality A), complete all as specified and as directed. |
| 6 | S&F of joist, channel, angle, flat iron or Tee sections, fixed independently with connecting plates, etc confirming to Fe 410-W (Gde 250 quality A), complete all as specified and as directed. |
| 7 | Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet, complete all as specified and as directed. |
| 8 | Dismantling timber scantling 40 sqcm and over in section, in any postion (frame work), complete all as specified and as directed. |
| 9 | Dismantling timber in fillets, rails, posts, rafters, pulins etc. under 40 sqcm in section fixed in any position framed work, complete all as specified and as directed. |
| 10 | S&F false ceiling with powder coated exposed GI grid suspension system (E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross Tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross Tees of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. Suspensor system (Grid) made out of GI sheet main Tee of size 23.5mmx38.50mmX0.36mm and cross Tee of size 23.5mmX23.5mmX0.36mm and angle size 19mmx19mmX0.36 mm. Grid of modular size 600mmX600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density>1200Kg/Cum) of size 595mmX595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8, complete all as specified and as directed. (Make : Everest or equvalent as approved by GE) |
| 11 | Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 12 | M&L Rendering 5mm thick on fair faces of brick work or concrete surfaces CM (1:3) on concrete surface as in ceiling/chajja and RCC surfaces , to be finished even and smooth (without using extra lime or cement), complete all as specified and as directed. |
| 13 | M&L 20 mm thick rendering (in two coats 10mm+5mm) on fair faces of brick work or concrete surface in CM (1:4) on external wall finished even and fair mixed with integral water proofing compound @ 3% by weight of cement in 2nd coat or in the manner specified by the manufacturer and in the proportions indicated, complete all as specified and as directed.Note:-WPC will be measured and paid separately as supply only. |
| 14 | Supply only integral water proofing compond, complete all as specified and as directed. |
| 15 | M&L for 15mm thick rendering in CM (1:6) onfair facces of brick work or concrete surfaces, rendering finished even and fair (without using extra cement), complete all as specified and as directed. |
| 16 | M&L for preparation of new plastered surfaces of any description over 10 cm width or girth applying two coats of oil bound distember using mechanical spay gun /hand roller over a coat of interior wall primer and including 1mm thick wall care putty in two coats (Biral white or equivalent), complete all as specified and as directed. |
| 17 | M&L for complete removal of exisitng treatment and applying two coats of oil bound distemper using mechaincal spray gun/hand roller over a coat of interior wall primer and with including 1mm thick wall care putty in two coats (Birla white or equivalent), complete all as specified and as directed. |
| 18 | M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint, complete all as specified and as directed. |
| 19 | M&L for preparation existing treatement of walls and applying two coats of cement base paint, complete all as specified and as directed. |
| 20 | M&L for preparation of old plastered or unplastered surfaces of wall and applying one coat of white wash on walls, complete all as specified and as directed. |
| 21 | M&L for preparation of new plastered or unplastered surfaces of Ceiling and applying three coats of white wash on walls, complete all as specified and as directed. |
| 22 | M&L of preparation of old plastered or unplastered surfaces of ceiling and applying one coats of white wash on walls, complete all as specified and as directed. |
| 23 | Demolition of brick work or stone /boulder masonary built in cement mortar including all quions, arches pillars etc but excluding ashler facing dressed stone work and precast concrete, complete all as specified and as directed. |
| 24 | M&L for brick work with old size fly ash bricks straight or curved on plan exc 6m mean radius built in CM (1:4), complete all as specified and as directed. |
| 25 | M&L for PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in bed blocks for grouting hold fasts, coping, filing in pressed steel chowkhats or similar work including necessary for work as required, complete all as specified and as directed. |
| 26 | Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground level), complete all as specified and as directed. |
| 27 | M&L for 50 mm thick cement concrete (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection/path laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges, complete all as specified and as directed. |
| 28 | M&L for PCC (1:2:4) type B-2 (using 20 mm graded crushed stone aggregate) as in surface channels, drains including all necessary form work, complete all as specified and as directed. |
| 29 | M&L for reinforced cement concrete (nominal mix) (1:1/2:3) type A1 (20mm graded aggregates) as in chajjas and the like, complete all as specified and as directed. |
| 30 | M&L reinforced cmenet concrete (nominal mix) (1:2:4) type B1 (20mm grading crushed stone aggregates) as in slab supported walls, beams and columns in floors, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. |
| 31 | Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilliate demolition, complete all as specified and as directed. |
| 32 | Use & Waste of formwork to chajjas, cullah hoods, truoghs and smilar items including edges rough finished surfaces, complete all as specified and as directed. |
| 33 | Use & Waste of formwork to soffits of suspended slabs such as roof slabs landings and similar work not exc 200 mm thick (Horizontal or sloping ) flat fair finished surface, complete all as specified and as directed. |
| 34 | S&F of TMT bars 10 mm dia and over, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and as directed. |
| 35 | S&F of TMT bars 6 mm to 8 mm dia, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and as directed. |
| 36 | Demolition of stone slabs and tiles of any description or thicknees in floors, aprons etc laid bedded and pointed in any mortar, complete all as specified and as directed. |
| 37 | M & L Granite (of any type) work 20MM thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in 20mm thick CM (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed. |
| 38 | M&L for 10mm thick rendering CM (1:3) on other than fair faces of brick or concrete surfaces of internal walls in sunken portion finished even and fair with WPC (WPC measured separately), complete all as specified and as directed. |
| 39 | M&L for first layer of slurry of cement at the rate of 0.488Kg/Sqm mixed with acrylic based polymer modified cementitous composite compound at the rate of 0.253kg/Sqm this layer will be allowed to air cure for 4 hours,second layer of slurry of cement at the rate 0.242 kg/Sqm mixed with acrylic based polymer modified cementitous composite compound at the rate of 0.126 kg/Sqm.this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours including 200 micron thick polythene film pasted with the help of adhesives shall be provided over above treatment.NOTE:The rate includes preparation of surface,treatment and sealing of all joints,corners,junctions of pipes and masonary within polymer mixed slurry.This treatment shall be provided after provision of pipes and masonary within polymer mixed slurry.This treatment shall be provided after provision of cement plaster mixed with WPC and synthetic fibers while concrete is still green, complete all as specified and as directed.Make: STP/Dr Fixit sunken treatment/psdilite eqavalent. |
| 40 | M&L for Non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to relevant IS (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 15 mm thick screed bed in CM (1:6), complete all as specified and as directed. |
| 41 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (squre or rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etcc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 20 mm thk screed bed in CM (1:6), complete all as specified and as directed. |
| 42 | M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm in verticl surface such as skirting, dados, and riser to septs tec set and jointed in neat cement slurry and pointed in whtie or coloured cement to match the surfaces of tile over and incl 10 mm thick rendering in CM (1:4), complete all as specified and as directed. |
| 43 | M&L 350x 250x 7 mm or 450X 350X 7mm thick coloured glazed ceramic tiles fixed as in vertical surface such as risers of steps, skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick rendering in CM (1:4) finished even and rough, complete all as specified and as directed. |
| 44 | M&L for machine cut Kota stone slab flooring 17-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing and exposed edges of kota stone shall be rounded complete over and including 20 mm thick screed bed or bedding layer in CM (1:6) finished even and rough, complete all as specified and as directed. |
| 45 | M&L for machine cut Kota stone slab as in vertical surfaces such as dado/skirting, 17-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing and exposed edges of kota stone shall be rounded complete over and including 15 mm thick backing plaster in CM (1:4) finished even and rough, complete all as specified and as directed. |
| 46 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing rubbish off the, complete all as specified and as directed. |
| 47 | Taking down chowkhats or frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame), complete all as specified and as directed. |
| 48 | Taking down chowkhats or frame exc 1.50 sqm but n.exc 4.00 Sqm each with shutter (without taking off shutters from the frame), complete all as specified and as directed. |
| 49 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet used reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and as directed. |
| 50 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles a PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; t both side Prelam PVC sheet used instead of Plaincolour PVC sheet. Stile and rails feathered at edges beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed. |
| 51 | S&F Pressed steel frames 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and as directed. |
| 52 | S&F Pressed steel frames 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and as directed. |
| 53 | S&F 35mm thk second class hard wood, plain, framed panelled shutters (any number of panels) with panels of 12mm thk timber flat on both sides (feather edged) or of 12mm thick veneered particle board medium density wood particle board with commericial face veneers, complete all as specified and as directed.(Note the dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I) |
| 54 | S&F 35mm thk second class hard wood, glazed and skeleton shutters, open rebated and prepared to receive galss, gauge tec, divided in to square with plain chamfered or rounded, mitred and without sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats, complete all as specified and as directed.(Note the dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I) |
| 55 | S&F steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed. |
| 56 | S&F steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and as directed. |
| 57 | S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed. |
| 58 | S&F steel window or ventilator fixed type with glazing bar, complete all as specified and as directed. |
| 59 | S&F in repair stainless steel wire cloth 0.36mm nominal dia if wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and as directed. |
| 60 | S&F galvanised mild steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and as directed. |
| 61 | S&F 4 mm thick figured glass, pin head type and glazing with oil putty in square not exc 0.50 sqm in each pane, complete all as specified and as directed. |
| 62 | S&F 3mm thk steel glass ordinary quality and glazing with oil putty in squiare not exc 0.50 sqm in each pane, complete all as specified and as directed. |
| 63 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame incl punching or drilling out old glazing pins/spring clips and providing and fixing new ones, complete all as specified and as directed. |
| 64 | S&F mild steel framed work such as grills, grating etc with end of bars shouldered and or riveted or forged into spikes framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing and similar work confirming to Ge-410-0 or Fe 310, complete all as specified and as directed. |
| 65 | S&F in repairs 25mm dia curtain rod (curtain rails), alumunium alloy, powder coated with and including decorattive knobs etc, complete all as specified and as directed. |
| 66 | M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide, complete all as specified and as directed. |
| 67 | M&L preparation of old steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 68 | M&L preparation of new wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed. |
| 69 | M&L preparation of old wood or wood based surface of any description over 10 cm width or girth not otherwise desccribed and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 70 | M&L 2nd class hardwood plain, solid, straight chowkhats and frames wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed, complete all as specified and as directed. |
| 71 | S&F 18/19mm thick block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on one face, complete all as specified and as directed. |
| 72 | M&L for 12mm thick block boards, grade 2 quality interior grade, commericial type fixed with screws to timber frame work including exposed surfaces finished with external teak wood lipping 6mm thick fixed with nails fixed in repair, complete all as specified and as directed. |
| 73 | M&L for plain fillets of sectional area exc 13 sqcm but not exc 25 sqcm square rectangular or triangular in section, wrought, secured with screws, splayed, chamfered or rounded, complete all as specified and as directed. |
| 74 | S&F 1st class hard wood external teak wood lipping 6mm thick on exposed surface of prelaminated particle board fixed with nails, complete all as specified and as directed. |
| 75 | S&F in repairs brass chromium plated tubular towel rail of 20mm dia D' type 60cm long between flanges, complete all as specified and as directed. |
| 76 | S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and as directed. |
| 77 | Demolition and breaking up old broken , PVC (SWR) , Cast Iron, AC, SWG soil waste and vent pipe of 75/110 mm bore including accessories set in cement mortar and removing rubbish from site, complete all as specified and as directed. |
| 78 | S&F of 110 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed. |
| 79 | S&F of 75 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed. |
| 80 | S&F of 110 mm bore PVC (SWR) bend any radius with access door, complete all as specified and as directed. |
| 81 | S&F of 75 mm bore PVC (SWR) bend any radius with access door, complete all as specified and as directed. |
| 82 | S&F of 110 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement, complete all as specified and as directed. |
| 83 | S&F of 75 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement, complete all as specified and as directed. |
| 84 | S&F of 110 X 75 mm bore PVC (SWR) reducer including jointing with solvent cement, complete all as specified and as directed. |
| 85 | S&F of 110mm bore PVC SWR vent cowl including jointing with solvent cement, complete all as specified and as directed. |
| 86 | S&F of 75mm bore PVC SWR vent cowl including jointing with solvent cement, complete all as specified and as directed. |
| 87 | S&F in repairs 75 mm size PVC (SWR) floor trap plain with grating including jointing with solvent cement, complete all as specified and as directed. |
| 88 | S&F in repairs Soap dish, CP, fixed to plugs with chromium plated brass screws, complete all as specified and as directed. |
| 89 | S&F in repair 15 mm bore PVC connection 450 mm long with two brass chromium plated brass nuts and PVC washers, complete all as specified and as directed. |
| 90 | S&F Vitreous China wash basin, flat back, size 450x300mm white, excluding taps, waste, chain and plug and rcelain stopper but including brackets, complete all as specified and as directed. |
| 91 | S&F in repairs angle stop valve 15 mm bore, chromium plated, fancy type, with wall flange, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and as directed. |
| 92 | S&F in repair 15 mm bore chromium plated bib tap fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and as directed. |
| 93 | S&F in repairs water closet (squatt pattern) of vitreous china squatting pan of pattern \\"ORRISA\\" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonic pipe etc complete including trap set in and including necessary lean cement concrete, complete all as specified and as directed. |
| 94 | S&F in repairs PVC low level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type, complete all as specified and as directed. |
| 95 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth, complete all as specified and as directed. |
| 96 | Taking up or down 15 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site, complete all as specified and as directed. |
| 97 | Supplying and laying of CPVC pipe of 16mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling laying in floors, complete all as specified and as directed. |
| 98 | Supplying and fixing of Brass Elbow, complete all as specified and as directed. |
| 99 | Supplying and fixing of Brass Elbow (3/4X1/2), complete all as specified and as directed. |
| 100 | Supply and laying CPVC brass Tee of 16mm bore tubes medium grade fittings on walls/ceiling or laying in floors, complete all as specified and as directed. |
| 101 | Supply and laying of CPVC male brass threaded Adaptor (MTA/MBTA) of 16mm bore tubes medium grade fittings on walls/ceiling or laying in floors, complete all as specified and as directed. |
| 102 | Supply and laying of CPVC female brass threaded Adaptor (MTA/MBTA) of 16mm bore tubes medium grade fittings on walls/ceiling or laying in floors, complete all as specified and as directed. |
| 103 | Supply and laying of CPVC Union of 16mm bore tubes medium grade fittings on walls/ceiling or laying in floors, complete all as specified and as directed. |
| 104 | S&F of 15 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor, complete all as specified and as directed. |
| 105 | Taking up or down 20 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site, complete all as specified and as directed. |
| 106 | S&F of 20 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor, complete all as specified and as directed. |
| 107 | S&F 100 mm size butt hinges, medium weight , cold rolled, mild steel, complete all as specified and as directed. |
| 108 | S&F of 150 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed, complete all as specified and as directed. |
| 109 | S&F of 100 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed, complete all as specified and as directed. |
| 110 | S&F 125 mm size Aluminium handles, cast type, anodised and fixed, complete all as specified and as directed. |
| 111 | S&F 150 mm size Aluminium handles, cast type, anodised and fixed, complete all as specified and as directed. |
| 112 | S&F in repairs of 1mm thick stainless steel sink with drainage board kitchen or laboratory type with waste pipe, plugs, wahsers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size of sink 915x460mm and bowl size 410mm x330mm x160mm, complete all as specified and as directed. |
| 113 | S&F in repair kitchen plate rack made out of stainless steel 0.50 mm thick sheet with partitions andd size of rack 800x250x900mm with shape and pattern as per sample kept in Sampel room of GE Office, complete all as specified and as directed. |
| 114 | S & F continuous (Piano) hinges 30 mm width mild steel ,bright finish fixed with screw, complete all as specified and as directed. |
| 115 | S&F in repairs Brass chromium plated shower rose with or without swivel joints 125 mm size including fixing to steel pipe or union, complete all as specified and as directed. |
| 116 | S&F fancy type pillar taps, cast copper alloy, with capstan heads chromium plated screwed down, high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts screwed for iron pipe and fixed, complete all as specified and as directed. |
| 117 | Taking down unserviceable copper/aluminium point wiring of any description including all fittings and fixtures (switch , socket, switch socket combination, lamp holder, ceiling rose,light fittings and regulator etc.) and making good disturbed surfaces of wall, floor etc. to match with existing finishes, complete all as specified and as directed. |
| 118 | Dismantling and taking down unserviceable main switches, DBs any type / size and making good disturbed surfaces to match with the existing finishes, complete all as specified and as directed. |
| 119 | M & L for concealed point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with multi stranded copper conductor with proper colour coding drawn through and including PVC conduit (medium grade) with all fittings and accessories ISI marked concealed in wall/fixed to roof,ceiling etc incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLSH, ISI marked as earth continuity conductor (green in colour) connected to common earth dolly incl fixing of modular metal flush boxes of appropriate size & thickness fixed flush to wall with modular back plate and top cover for mounting switch, sockets etc including cutting chases for conduits & sinkings for modular boxes & making good the disturbed surfaces, matching to the existing one etc for one light/Bell/Exhaust fan point controlled by one, one way switch 5/6 Amps, complete all as specified and as directed. |
| 120 | Description all as per item No 119.00 here in before but for one 3 point 5/6 Amps switch socket outlet point controlled by one switch on the same board. |
| 121 | Description all as per item No 119.00 here in before but for one 3 pin 5/6 Amps switch socket outlet point controlled by one switch on independent board. |
| 122 | Description all as per item No 119.00 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLSH PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. incl modular white cover plate complete alll as specified and as directed. |
| 123 | Supply and fix Modular switch 1 way 6 A,1 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 124 | Supply and fix Modular switch 1 way 16 A,1 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 125 | Supply and fix Modular Bell push 6A 1 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 126 | Supply and fix Bell, Ding Dong electric AC 230 Volts single pole, complete all as specified and as directed. |
| 127 | Supply and fix Socket, 6A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 128 | Supply and fix Socket, 6A/16A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked, complete all as specified and as directed. |
| 129 | Supply & Fixing ceiling rose surface bakelite 65 X 50 mm three terminal, complete all as specified and as directed. |
| 130 | Supply and fixing Modular lamp/Angle holder insulated body with back plate for batten fitting, complete all as specified and as directed. |
| 131 | Supply and fixing 10W LED retro fit B-22 holder base with poly carbonate body and aluminium heat sink Invertor lamp, complete all as specified and as directed. |
| 132 | Supply and fixing LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption 20W, system efficiency of ≥100 lumens/W, Ingress protection IP 20, colour rendering index CRI>80, driver efficiency>85%, power factor > 0.90, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min), complete all as specified and as directed. |
| 133 | Supply and fixing LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption 10W, system efficiency of ≥100 lumens/W, Ingress protection IP 20, colour rendering index CRI>80, driver efficiency>85%, power factor > 0.90, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min), complete all as specified and as directed. |
| 134 | Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and as directed. |
| 135 | Supply and fixing LED light fitting 1x9W/1X10W IP66 & IK09 integral LED Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable fitting, complete all as specified and as directed. |
| 136 | Supply and fixing wall mounting, brushed nickel finish fixture with acrylic diffuser suitable with 9 W LED lamp B22 base, complete all as specified and as directed. |
| 137 | M&L for sub main wiring along with earth wire of size two run of 4 sq mm + one run of 4 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLSH including drawing into 25 mm PVC conduit concealed in wall/roof including taking down of old unservicible sub main wiring, complete all as specified and as directed.(Note: Three run of 4 Sq mm copper wire including one run of 25 mm of size PVC condute shall be measured as one unit length). |
| 138 | M&L for sub main wiring along with earth wire of size two run of 6 sq mm + one run of 6 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm PVC conduit concealed in wall/roof including taking down of old unservicible sub main wiring, complete all as specified and as directed.(Note Three run of 6 Sqmm including one run of 25 mm of size PVC condute shall be measured as one unit length). |
| 139 | Supply and fixing TPN DB with suitable for TPN MCB incomer, double door (IP-43), 4 Ways, built- in 100 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz, flushed in wall or fixed on surface, complete all as specified and as directed. |
| 140 | Supply and fixing Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 100 Amps rated Single pole and neutral link of 8 way 240 Volts AC, concealed in wall, complete all as specified and as directed. |
| 141 | Supply and fixing 415V, 10KA 'C' curve miniature circuit breaker (MCB) of TPN 40 to 100 Amps capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 142 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of DP 40-63 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 143 | Supply and fixing in repairs 240V, 10KA 'C' curve miniature circuit breaker (MCB) of DP 32 AMP capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 144 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 145 | S&F metal plug socket single pole and neutral encloser with two pin earth plug with 01 No MCB SP 20 Amp, C series, complete all as specified and as directed. |
| 146 | Supply and Fixing exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including fixing arrangement complete all as specified and directed. including taking down old u/s Exhaust fan & deposit to MES Store, complete all as specified and as directed. |
| 147 | Supply and fixing electric water heater storage type wall hanging mounting type with powder coated metallic body BEE 5 Star rated with diamond glass lined inner tank with maximum operating pressure of 8 bars incuding factory fitted thermostat maximum 75 Celsius with automatic thermal cutout and multifunctional saftey valve inculding suitable nuts & bolts for fixing arrangement operates on 230V ,maximum power consumtion -2kW of capacity 25 Ltrs , with all accessories and connection pipe 15mm bore 2 Nos for hot and cold water supply,geyser saftey cord with 16Amps ELCB complete including taking down old u/s Geaser & deposit to MES Store, complete all as specified and as directed.Make: Havells Cat Part No : Monza Nu GHWAMUSWH025 or equivalent Racold, Bajaj |
| 148 | Taking down Electric KWH meter and keep in safe custody and refixing the same including testing on completion, complete all as specified and as directed. |
| 149 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC (1:3:6) type C-1 , 50 mm thick pre cast RCC (1:2:4) type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I and as directed. Including taking down old unserviceable earthing, complete all as specified and as directed. |
| 150 | Material and labour in repairs for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core, including glands, lugs, nut, bolts, washers as required at site, testing, complete all as specified and as directed. |
| 151 | Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for LT under ground cable/pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and as directed. |
| 152 | Returning, filling in, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer, complete all as specified and as directed. |
| 153 | Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and as directed. |
| 154 | Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches, complete all as specified and as directed. |
| 155 | M&L in repairs Sub class ‘B’bricks for covering to cable laid dry flat ,with width equal to the length of brick, complete all as specified and as directed. |
| 156 | S & F in repairs Steel pipe glavanized light grade of 40 mm dia laid in trenches or under ground/floor or road of fixed with pole for protection of cable/ Earth sstrip including clams with bolts nuts and wasers, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 157 | S & F in repairs Steel pipe glavanized light grade of 40 mm dia laid in trenches or under ground/floor or road of fixed with pole for protection of cable/ Earth sstrip including clams with bolts nuts and wasers, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail