| 1 | Total amount of the \\"Rate Schedule\\" sheet SCHEDULE OF QUANTITY AND RATE FOR REPLACEMENT OF ACSR BARE CONDUCTOR BY 11 KV AAAC AL-59, 99 SQMM. COVERED CONDUCTOR OF 11 KV BADKALI FEEDER UNDER 33/11 KV SUB-STATION, LACHHIWALA UNDER EDSD, DOIWALA UNDER EDD, DOIWALA AGAINST E-TENDER SPECIFICATION NO.18/EDCRDDUN/2026-27 Name of The Bidder's Firm: 0.0 Sl. No. Description of Work Unit Qty Rate Amount Part [A] (Supply Portion) |
| 2 | Earth wire Clamp for ST Pole SP-55 With N&B |
| 3 | PP & Clamp for ST Pole SP-55 with N&B |
| 4 | Stay Clamp for ST Pole SP-55 with Nut & Bolt |
| 5 | Stay Clamp for ST Pole SP-33 with Nut & Bolt |
| 6 | PP & Clamp for ST Pole SP-33 with N&B |
| 7 | LT Clamp for ST Pole SP-33 with N&B |
| 8 | Earth wire Clamp for ST Pole SP-33 With N&B |
| 9 | Shackle Insulator 100x115 mm. with N&B |
| 10 | Bracing Clamp for ST Pole With N&B |
| 11 | IPC with Aluminium Bail for Earthing |
| 12 | 11 KV Cable Ties on Pin Insulator |
| 13 | 11 KV IPC for Covered to Covered Conductor |
| 14 | 11 KV IPC for Covered to Bare Conductor |
| 15 | 11 KV Mid Span Jointing Kit |
| 16 | 11 KV Tension Clamp with Bail & IPC |
| 17 | 11 KV AAAC Covered Conductor AL-59, 99 Sqmm. Total - Part [A] 0.0 Part [B] (Labour Portion) |
| 18 | Cartage of ST pole from store centre to construction site with loading, unloading at both points and proper stacking. (51-70 Km.) SP-33 Nos 25.0 0.0 SP-55 Nos 10.0 0.0 |
| 19 | Cartage of other material (other than poles) by vehicle fro Store Center to nearest construction site Store including loading and unloading at both ends. (51-70 Km.) Rs.Per Qtl. Qtl 24.0 0.0 |
| 20 | Head load cartage of following Poles from road to site. Upto 0 to 1 Km. SP-33 Nos 25.0 0.0 SP-55 Nos 10.0 0.0 |
| 21 | Chemical Earthing:Earthing of distribution transformer including digging of pit of size 2.5 Mtr depth and make hole of size 150 mm. Placing of earthing electrode (to be supplied by contractor as per drawing No. A) as drawing B, connecting the same with G.I. Strip (to be supplied by contractor ) of size 35x6 mm as per drawing C for a minimum lenght 6 m. treatment of soil with highly condctive substance as per IS 30343 complete in all respect, result of earthing resistance to be recroded in M.B. before and after installation of earthing. The earth resistance after earthing should be less than 1 Ohm. |
| 22 | Earthing with M.S. Earth rod of 2.5 meter long by hammering of M.S. Rod to proper depth and connecting the earth electrode with the help of G.I. wire as per construction manual. |
| 23 | Fabrication of M.S. Channel Angle iron after cutting in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESPO sehedule and local approved drawing. |
| 24 | Excavation of earth for stay pit of size 0.06x0.06x1/2 mtr. in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work |
| 25 | Fixing , tightening and nozzaling of Stay with pole and stay rod on required tension as per drawing / RESPO manual. 11 KV line Nos 30.0 0.0 |
| 26 | Grouting of Stay in size 0.6x0.6x0.3 in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cernent,sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESPO Manual. |
| 27 | Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work |
| 28 | Erection of following Single support pole in proper level and alignment alongwith fixing of all accessories, like top channel & clamps as per RESPO construction Manual. SP-33 Nos 15.0 0.0 SP-55 Nos 6.0 0.0 |
| 29 | Erection of following Double support pole in proper level and alignment alongwith fixing of all accessories, like top channel, X-bracing & clamps as per RESPO construction Manual. SP-33 Nos 5.0 0.0 SP-55 Nos 2.0 0.0 |
| 30 | Grouting of pole in size 0.45x0.45x1/9 of the support in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cement,sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESPO construction Manual. |
| 31 | Muffing of poles size 0.45 cm x 0.60 cm radius with cc 1:3:6 (1 cement: 3 coarse sand : 6 graded stone 10mm nominal size) block size 45cm height from ground level including cost of cement, stone and sand etc. |
| 32 | Dismantling of existing LT/HT line. including disc fitting, Insulator, clamps, Nut & Bolts and consumer connections and Street light connections etc. including rolling of conductor and cartage back from site to JE store 11 KV line (Weasel) Ckm 8.5 0.0 |
| 33 | Erection of Bracket in 11 KV line |
| 34 | Guarding of LT/11 KV line |
| 35 | T-off Connection complete 11 KV line |
| 36 | Making of Section Pole |
| 37 | Disconnection & Reconnection of Consumer |
| 38 | Tightening of Stay Set |
| 39 | Fixing of IPC with Aluminium Bail for Earthing |
| 40 | Jumpering and connection complete on the D/P conductor to TPMO fuse set & T/F |
| 41 | Realignment of Tilted Pole |
| 42 | Fixing of 11 KV 90KN Tension Clamp B&IPC |
| 43 | Fixing of 11 KV Suspension Ties |
| 44 | Fixing of 11 KV Mid Span Jointing Kit |
| 45 | Fixing of 11 KV IPC for Covered to Covered Conductor |
| 46 | Fixing of 11 KV IPC for Covered to Bare Conductor |
| 47 | Laying Spreading, Stringing AAAC Conductor |
| 48 | Back Cartage of Petty Material, 0-20 km |
| 49 | Route cleareance by cutting of tree branches / pruning, lopping and chopping of trees for L.T., 11 & 33 KV line. Total - Part [B] 0.0 TOTAL [Part-(A) + Part (B)] 0.0 Place Date Superintending Engineer Please Enable Macros to View BoQ information |