| 1 | DSR Item No. 1.10Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 2 | Group-C |
| 3 | DSR item No.1.31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 4 | DSR item No.1.32Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 5 | DSR Item No. 1.15Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. |
| 6 | Group-C |
| 7 | DSR Item No.1.21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 8 | DSR Item No. 1.17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 9 | 3 x 1.5 sq. mm |
| 10 | 3 x 2.5 sq. mm |
| 11 | 3 x 4 sq. mm |
| 12 | DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator). |
| 13 | 4 way (4 + 12) Double door |
| 14 | 6 way (4 + 18) Double door |
| 15 | DSR item No.1.24Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 16 | 5/6 amps switch |
| 17 | 3 Pin 5/6 A. socket outlet |
| 18 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 19 | Single pole |
| 20 | Triple pole and Neutral |
| 21 | DSR item No.1.27Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 22 | 6 Module (200 mmX75 mm) |
| 23 | 8 Module (125 mmX125 mm) |
| 24 | 12 Module (200 mmX150 mm) |
| 25 | DSR item No.1.57 Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 26 | DSR item No.1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 27 | DSR item No.1.26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 28 | DSR Item No. 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 29 | 200 A,36KA,FPMCCB |
| 30 | 125 A,36KA,FPMCCB |
| 31 | 400 A,50KA,FPMCCB |
| 32 | Supply and erection of sheet metal bus-bar chamber on existing surface with required No. of bus-bar strips of suitable length and cross-sectional area, made of copper strips of suitable length and cross-sectional area enclosure made of M.S. ,.(As per Complete Item No. 15 of the DNIT) |
| 33 | Sheet metal bus-bar chamber suitable for 100 Amp. 415 Volts capacity with 4 copper strip Bus-bars each of length 900 mm & cross-sectional area (25.4mmx3.17mm) enclosure having overall dimensions (1280mm x 400mm x 150mm) nominal. |
| 34 | Sheet metal bus-bar chamber suitable for 200 Amp. 415 Volts capacity with 4 copper strip Bus-bars each of length 900 mm & cross-sectional area (25.4 mmx3.17mm) enclosure having overall dimensions (1280mm x 550 mm x 200mm) nominal. |
| 35 | DSR ITEM NO. LED 8.9.5Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,(As per Complete Item No. 16 of the DNIT) |
| 36 | 18-22 watt |
| 37 | DSR Item No. 8.6LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, (As per Complete Item No. 17 of the DNIT). |
| 38 | 36 Watt |
| 39 | DSR Item No. 8.16LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy ≥120 and <135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, (As per Complete Item No. 18 of the DNIT) |
| 40 | 70 Watt |
| 41 | 100 Watt |
| 42 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, (As per Complete Item No. 19 of the DNIT). |
| 43 | Size 15” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make EXHD 300-6-1/ Bajaj make Supreme PLUS/ Usha make Turbo HDEF only. |
| 44 | Supply and erection of 14 GMS sheet frame of suitable size for erection of exhaust fan. The hole should be suitable required size for exhaust fan shall be cut from the centre of the sheet duly fixed on existing M.S. glazing/ ventilator. (As per Complete Item No. 20 of the DNIT) |
| 45 | Suitable for 12” / 15” / 18” Exhaust Fan. |
| 46 | DSR ITEM NO. 9.2Brush Less Direct Current (BLDC) MotorSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, (As per Complete Item No. 21 of the DNIT) |
| 47 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 48 | Supply and fixing of 12 modules (200 mm x 150 mm) G.I box suitable for accommodate the following accessories along with modular base and cover plate for modular switches in recess / surface etc as required for Computer Point with 4 Nos. 5/6 Amp.,(As per Complete Item No. 22 of the DNIT) |
| 49 | Supply & erection of fresh air fan high speed motor with copper wound 6” sweep with louver and plastic body complete with high speed motor, blades, epoxy powder coated of Havells make Ventiliar DX White / Orient make Ventilator / Crompton make Brisk Air/ Bajaj make 70049 150mm sweep only. (As per Complete Item No. 23 of the DNIT) Please Enable Macros to View BoQ information |