| 1 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 2 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 3 | Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 4 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 5 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 6 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 7 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 8 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 9 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 10 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 11 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I.With commercial grade colour 15X15cm Tiles. |
| 12 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 13 | Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I. |
| 14 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 15 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 16 | Providing two coats of plastic emulsion paint of approved shade and make over old surface including washing cleaning and preparing the walls scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 17 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ .90 kg/10 sqm). |
| 18 | Carriage of Materials(ii) Sand-Lead (1k+9p) KM |
| 19 | (iii) Stone Chips-Lead(1US+69S) KM |
| 20 | (v) (Cement )-Lead 5KM |
| 21 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees shurbs all complete as per approved design building specification and direction of E/I. |
| 22 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 23 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 24 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 25 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 26 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 27 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 28 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 29 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 30 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) |
| 31 | Providing designation 75Bwork in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I. |
| 32 | Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 33 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 34 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I. |
| 35 | Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg. |
| 36 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 37 | Carriage of MaterialsBricks Lead = 1U+59S)kM |
| 38 | Sand lead =(1U+9S) km |
| 39 | Stone chips lead = (1U+40S) km |
| 40 | Earth work in excavation ( as per I.S. 3114/1965 for laying of different types and sizes of pipes so as to give 1 m av. cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of E/l. |
| 41 | Earth work in back filling the trenches after laying different types and size of pipes with earth removed dufing excavation within initial lead and lift as per specification and direction of E/l. ( For classification of Soil item - A & B) |
| 42 | Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350 gms.) with extra socket all compere as per specification and direction of E/I. |
| 43 | Providing and fixing brass / C.I. Stop cock of approved quality all complete as per specification and direction of E/l . A) BRASS STOP COCK (a) 15 mm dia |
| 44 | Providing and fixing Gun metal full way valve of approved qualtiy, all complete as per specification and direction of E/l(a) 32 mm dia wt not less than 700 gms |
| 45 | (a) 40 mm dia wt not less than 1kg |
| 46 | Supplying, fitting and fixing viterious white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair or viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. (A) 580 mm long (c ) with 10 litre low level p.v.c cistern |
| 47 | Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed c.l. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms., 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/l. |
| 48 | Stainless Steel kitchen sink with drain board 510x1040mm bowl depth 200mm |
| 49 | Making holes in walls for laying G.I. pipe and restoring the same after pipe laying as per specification and direction of E/I.(i) 125 mm thick wall |
| 50 | (ii) 250 mm thick wall |
| 51 | Supplying, Fitting and Fixing Bathroom Fitting of approved make and as per IS specification all cost complete as per direction of E/I. (All rates have been adopted from the basic rate from SOR+15% for labour and contractor profit ) ALL JAGUAR FITTINGpiller cock (LongNeck) (For Basin) |
| 52 | Bib Cock (Long Thread) |
| 53 | Angular Stop Cock (Long Thread) |
| 54 | 4 way diverter for concealed fitting |
| 55 | Towel Ring 24\\" |
| 56 | Glass Shelf 22\\" |
| 57 | Supplying materials and labours for constructing inspection chamber of designation class 75 B bricks size 750 mm deep, 600 x 450 internal dimension having 250 mm wall thickness in cement mortar ( 1:6 ) including 12 mm cement plaster ( 1:4 ) with punning on inside and cement plaster (1:6 ) with 600 x 475 mm G.I. cover with frame (Weight not less than 36 Kg.) in foundation and refilling all complete as per specification and direction of E/l. |
| 58 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc.15 mm nominal outer dia .Pipes. |
| 59 | 20 mm nominal outer dia .Pipes. |
| 60 | 25 mm nominal outer dia .Pipes. |
| 61 | 32 mm nominal outer dia .Pipes. |
| 62 | Providing and fixing PTMT grating of approved quality and colour.Circular type. 100 mm nominal dia. |
| 63 | 125 mm nominal dia with 25 mm waste hole. |
| 64 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/l.Mirrors of 4 mm thick plate glass bevelled edge mirror including C.P brass revolving fittings, 3 mm plywood board and C P hinges to fix with mirror600mmx450mm size |
| 65 | Polyethylene water storage tank of ISI mark (eg Sintex/Sinter/himgiri/gangotri etcc with cover & locking system) |
| 66 | Point wiring in PVC consuit, with piano type switch -Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as requiredGroup - B |
| 67 | Group - C |
| 68 | Twin control point wiring in PVC conduit, with piano type switch -Wiring for Twin Control light point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way paino type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as required. |
| 69 | Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire |
| 70 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 71 | 2 x 4 sq.mm + 1 x 4.5 sq.mm earth wire |
| 72 | 2x 10 sq.mm + 1 x 10 sq.mm earth wire |
| 73 | Supplying and fixing folowing size of PVC/G.I box on surface / recess with suitable size of phenolic laminated sheet cover in front including painting etc.as required.75mmx75mmx50mm (4\\"x4\\") |
| 74 | 72mmx146mmx48mm(4\\"x7\\") |
| 75 | 210mmx206mmx48mm(10\\"x12\\") |
| 76 | 12\\"(230MM) Metal Exaust Fan |
| 77 | Bulk Head Fitting with 9/10 Watt LED. |
| 78 | S/F ceiling rose - Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as required. |
| 79 | S/F Batten holder - Supplying and fixing batten/angle holder including connection etc. as required. |
| 80 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 81 | ITC exhaust fan upto 450mm sweep - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing commissioning etc. as required. |
| 82 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6amps, one way switch |
| 83 | 5.6 amps, 3 pin socket outlet |
| 84 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 85 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.16 amps, double pole |
| 86 | 32 Amp Double Pole |
| 87 | 63 Amp Double Pole |
| 88 | 32 Amp TP&N |
| 89 | S/F four pole MCB isolator - Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioining etc. as required6/32 amps, Single Pole |
| 90 | 40 amps, DP |
| 91 | 50/63 amps, TPN |
| 92 | S/F T.P. MCB DB - Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4way.single door |
| 93 | 6way, single door |
| 94 | 8way, single door |
| 95 | 4way, Double door |
| 96 | 16way, Double door |
| 97 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 98 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 99 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 100 | Providing and fixing following capacity double pole/TP&N sheet metal switch disconnector fuse switch unit inside the existing metal board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. |
| 101 | Providing and fixing following 4 pole panel mounted change over switches in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 102 | Providing and fixing following capacity double pole/TP&N sheet metal switch disconnector fuse switch unit inside the existing metal board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. |
| 103 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 104 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 105 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 106 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection soldring etc, as required. |
| 107 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 108 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 109 | P/F G.I Lightening conductor tape in Vertical run- Providing and Fixing G.I tape 20mmx3mm thick on parapet or surface of wall for lightning conductor complete as required.(For Vertical Run). |
| 110 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 111 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 112 | Supplying of 48\\"(1200mm) Ceiling Fan |
| 113 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.(a) From 0.00 M to 50.00 M below G.L. |
| 114 | (b) From 51.0 M to125.00 M |
| 115 | (c) From126.0 M to150.00 M |
| 116 | (d) From151.0 M to200.00 M |
| 117 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 118 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 119 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 120 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 121 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages2 HP |
| 122 | Supplying fitting and fixing 4 crore 10 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I. |
| 123 | Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I. |
| 124 | GST @ 18% |
| 125 | Labour cess @ 1% Please Enable Macros to View BoQ information |