| 1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres |
| 2 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge. |
| 4 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 5 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :Of area 3 sq. metres and below |
| 6 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 7 | Dismantling G.I. Pipes ( external work ) including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking of pipes within 50 m lead as per direction of Engineer in charge: 15mm to 40 mm nominal bore |
| 8 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) c/y wall, f/y wall,garrage…etc |
| 9 | 12 mm cement plaster finished with a floating coat of neat cementof mix : 1:4 (1 cement: 4 fine sand) drain ST, chamber etc |
| 10 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 11 | Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 12 | Half brick masonry with non modular fly ash bricks of class 10, conformingio IS :12894, in super structure above designation V Level |
| 13 | Brick work with modular extruded brunt fly ash clay sewer bricks (Conforming to IS: 4885 ) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth . |
| 14 | Brick work with non modular fly ash bricks conforming to IS:12894,class designation 10 average compressive strength in above plinth level up to floor V level in Cement mortar 1:6 (1 cement : 6 Coarse sand) |
| 15 | Providing & laying in position cement concrete of specified grade excluding the cost of centering and shuttering- all work upto plinth level - 1:4:8 ( 1 cement 4 coarse sand : 8 graded stone aggregate 40mm nominal size) |
| 16 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick |
| 17 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 18 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS :15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 19 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.600x600 mm |
| 20 | Providing and fixing white vitreous china water closet squatting pan (Indian type) Orrisa pattern WC pan of size 580x440mm. |
| 21 | Providing and fixing white vitreous china pedastal type ( European type/ wash down type) water closet pan. |
| 22 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White |
| 23 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15 x 3 mm lugs 10 cm long embedded in cement concrete blocks 15 x 10 x 10 cm of 1;3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with dash fastener or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 24 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 25 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece |
| 26 | Providing and fixing to existing door frames. 30 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). |
| 27 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary fillings up of gaps at junctions, at top, bottom and sides with required PVC/ neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : For shutter for door,window & ventilator including providing and fixing hinges/pivots and making provision for fittings wherever required. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 28 | Renewing Glass panes with putty and nails wherever necessary including racking out the old putty -4mm thick |
| 29 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. Fixed to steel windows by welding. |
| 30 | Providing and fixing ISI marked oxidised M.S. Sliding door bolts with nuts and screws etc. complete : 300x16mm |
| 31 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 200x10 mm |
| 32 | Providing and fixing ISI marked M.S. Pressed butt hinges bright finished with necessary screws etc. Complete: 125 x 65 x 2.12mm |
| 33 | Providing and fixing ISI marked oxidised alluminium Sliding door bolts with nuts and screws etc. complete : 300x16mm |
| 34 | Providing and fixing ISI marked oxidised alluminium tower bolt black finish, (Barrel type) with necessary screws etc. complete : 200x10 mm |
| 35 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 125 mm. |
| 36 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 37 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body,door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 38 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete75x63x3.2 mm |
| 39 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 4.0 mm thickness. |
| 40 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. ( 2 time per year) |
| 41 | Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete- flexible pipe – 40 mm dia |
| 42 | Finishing wall with Acrylic smooth exterior paint-old work: One or more coat. |
| 43 | White washing with lime to give an even shade : Old work (one or more coats) |
| 44 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shads : old work ( one or more coats) . |
| 45 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacture,over the plasterd wall surface to prepare the surface even and smooth complete. |
| 46 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shads : New work (Two or more coats) over and including water thinable priming coat with cement primer. |
| 47 | Wall painting with plastic emulsion paint of approved brand and manufactyre to give an even shads : old work ( one or more coats) . |
| 48 | Painting with synthetic enamal paint of approved brand and manufacture to give an even shade : Two or more coats on new work. |
| 49 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. |
| 50 | painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade : one or more coats on old work(FLOOR) |
| 51 | Making plinth protection 50mm thick of cement concrete 1:3;6( 1 cement:3 coarse sand:6 graded stone aggregate of nominal size) over 75mm thick bed of dry bricks ballast 40mm nominal size well ramped and consilated and grouted with fine sand including finishing at top smooth. |
| 52 | Transportation of rubbish, garbages etc. including loading, unloading manually lead upto 5.00 Km by tractor trolley. |
| 53 | Providing & Placing on terrace ( at all floor levels) polyehylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank. |
| 54 | providing and fixing Tank jointer including pipe nipple upto 25mm dai all complete as per instruction of engineer incharge. |
| 55 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
| 56 | Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore. |
| 57 | Providing and fixing on wall face unplasticised Rigid PVC Rain water pipes conforming to IS :13592 Type A including jointing with sill ring conforming to IS :5382 leaving 10 mm gap for thermal expansion( 1) Single socketed pipe-110mm dia. |
| 58 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. ….Bend .110 mm dia |
| 59 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 60 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 61 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc of GI pipe 50mm dia External work |
| 62 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 15 mm nominal dia Pipes |
| 63 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes |
| 64 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes |
| 65 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes |
| 66 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore |
| 67 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore |
| 68 | Running maintenance of RO/water cooler excluding mazor breadown ,as per instruction of Engr incharge. |
| 69 | Writing and lettering by radium sticker at existing board up to height 5.00 m including all man and material complete job as per instruction of Engr incharge. |
| 70 | Painting and letter Writing by synthetic enamel paint at existing board up to height 5.00 m including all man and material complete job as per instruction of Engr incharge. |
| 71 | P&F PVC Water Storage Tank cover of different size, as per instruction of Engr incharge. |
| 72 | Dismantling and disposal of WC Pan and its rubbish of any size and lead of 50 metre all complete as per instruction of as per Instruction of Engineer In Charge. |
| 73 | Repairing and renovation of submersible pump & moter of 3.00 HP including binding, bush,water seal,impeller lath work and fitting charges,as per instructions oh Engg. Incharge. |
| 74 | Providing and fixing of control panel board ( starter ) 3.00 H.P.,three phase of approved make as per instruction of Engr. Incharge. |
| 75 | Providing and fixing submersible cable 4.00 sqmm with copper wire ISI Make as per instruction of engineer in charge. |
| 76 | Cleaning ,moppng and washing of floor, toilets ,fixities ,yard, road ,drain,roof of NRB buildings other places neatly all complete with tools,tackles etc to make the floor clean & hygienic as per instruction of Engr incharge.(cost of disinfectent seperatly paid ) Transit camp (diploying 4.00 Man Power per day ) |
| 77 | Cleaning ,moppng and washing of floor, toilets ,fixities ,yard, road ,drain,roof of NRB buildings other places neatly all complete with tools,tackles etc to make the floor clean & hygienic as per instruction of Engr incharge.(cost of disinfectent seperatly paid ) Central Hospital (diploying 9.00 Man Power per day ) |
| 78 | Cleaning ,moppng and washing of floor, toilets ,fixities ,yard, road ,drain,roof of NRB buildings other places neatly all complete with tools,tackles etc to make the floor clean & hygienic as per instruction of Engr incharge.(cost of disinfectent seperatly paid ) Officer club (diploying 1.00 Man Power per day ) |
| 79 | Cleaning ,moppng and washing of floor, toilets ,fixities ,yard, road ,drain,roof of NRB buildings other places neatly all complete with tools,tackles etc to make the floor clean & hygienic as per instruction of Engr incharge.(cost of disinfectent seperatly paid ) Sneh Milan (diploying 2.00 Man Power per day ) |
| 80 | Cleaning ,moppng and washing of floor, toilets ,fixities ,yard, road ,drain,roof of NRB buildings other places neatly all complete with tools,tackles etc to make the floor clean & hygienic as per instruction of Engr incharge.(cost of disinfectent seperatly paid )Audotorium (diploying 1.00 Man Power per day ) |
| 81 | Maintenance of Garden,lawn of already planted decorative plants including removal of unwanted vegation,grass and watering of plants etc complete ,as per insruction of Engineer -in-charge .Maintenance of garden at central hospital (02 man power mali) |
| 82 | Maintenance of Garden,lawn of already planted decorative plants including removal of unwanted vegation,grass and watering of plants etc complete ,as per insruction of Engineer -in-charge .Maintenance of garden at Transit camp (02 man power mali) |
| 83 | Maintenance of Garden,lawn of already planted decorative plants including removal of unwanted vegation,grass and watering of plants etc complete ,as per insruction of Engineer -in-charge .Maintenance of garden at officer club (02 man power mali) |
| 84 | Providing & fixing fly proof wire gauge to window,clerestory window & doors complete,stainless steel ( grade 304) wire gauge ( mosquito jali of 0.5 mm dia wire and 1.4 mm aperture on both sides. |
| 85 | Providing and fixing Maruti lock of approved quality as per instruction of engineer incharge. |
| 86 | Supply of phenyl of approved brand as per instruction of engineer in charge. |
| 87 | Supply of Nepthalene ball of approved brand as per instruction of engineer in charge. |
| 88 | Supply of Harpic of approved brand as per instruction of engineer in charge. |
| 89 | Supply of washing powder for domestic use of aooroved brand as per instruction of engineer in charge. |
| 90 | Providing of liquid soap 200 ml with bottel as per instruction of engineer in charge. |
| 91 | Supply of Air packet or equavalent as per instruction of engineer in charge. |
| 92 | Supply of room freshner of approved brand as per instruction of engineer in charge. |
| 93 | Supply of Dahalia plant ,as per instruction of engineer in charge. |
| 94 | Supply of Merygold (Genda) plant ( hybrid) ,as per instruction of engineer in charge. |
| 95 | Supply of Rose ( Gulab) plant ,as per instruction of engineer in charge. |
| 96 | Supply of Gudhal plant ,as per instruction of engineer in charge. |
| 97 | Supply of Flexible PVC hose Pipe 25mm(for gardening) , as per instruction of ingineer in charge . |
| 98 | Providing and fixing wallpaper with Approved quality of glue as per instruction of eng incharge |
| 99 | Trimming and trenching of tree branch mannually ( Height more than 10 feet) and disposal of cutting branches upto a lead of 50 mtr all complete job as per instruction of Engineer in charge. |
| 100 | Supplying and stacking sludge/ manure at site including loading, unloading and carriage complete job .(sludge measured in stacks will be reduced by 8% for payment )as per instruction of engineer in charge. |
| 101 | Providing and fixing Mortise stainless steel Door handle lock (complete set)approved quality as per Eng in charge |
| 102 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |