| 1 | Attending of day to day electrical complaints pertaining to internal electrification received through telephone/ Armaan or in person on detailment at MES Service centre located at Tibri Mil Stn area by locating and rectification of fault from and including electric meter/DB onwards in respect of sub main/point wiring including provisioning of small pieces of electric cable of size 1.5/2.5 Sqmm to 10 Sqmm single core copper conductor and length not exceeding 0.50 mtrs and fixtures for power and light socket/light, fan and bell etc and carrying out repairs to the extent of tightening of loose connections, disconnection and dismantling of faulty wires, battens, conduits, boxes, main switches, MCB's, DB's and other E/M fixtures including providing necessary screws / nuts / bolts / nails for the rectification of defect and refixing of existing dismantled serviceable items and replacement of defective items with new ones complete all as specified and directed. (Note - (i) Cost of labour for the fixing/replacement of unserviceable item shall deemed to be included in item No 1 and cost of store replaced shall be measured as supply only against relevant items). |
| 2 | (ii) Complaint pertaining to location and rectification of fault in more than one length of point wiring/sub main wiring/DB's/fitting or fixtures etc shall be considered as an independent complaint. Similarly complaint pertaining to replacement of two fixtures in one Qtr will also be measured and paid as one complaint.(iii) Replacement of more than two fixtures/items but multiple of three fixtures or part thereof in one Qtr/Bldg will be measured as an additional complaint.(iv) In case a Qtr/room is found locked when tradesman is detailed to attend the complaint, the complaint shall be treated as one till its completion.(v) Necessary tools for tradesman shall be provided by the contractor.(vi) Transportation for tradesman and normal stores required for complaints shall be arranged by the contractor.(vii) Complaints of normal nature shall be attended and rectified within 3 hours of receipt of complaint. However, complaints of emergent nature i.e no light, short circuit, earth fault etc shall be attended immediately on receipt of complaint round the clock. (viii) Bldgs requiring rewiring of small qty of point wiring if ordered will be measured and paid separately under respective items below |
| 3 | (ix) Bldgs requiring rewiring of small qty of point wiring if ordered will be measured and paid separately under respective items. (x) Contractor will deposit all the items to EM Store in advance and unsv items will be collected by the contractor as schedule of credit(xi) Electrician will report to AGE EM complaint cell at 9 O'Clock daily for collecting of complaints. Complaint received on Armaan application will be done in the same day and after completion of complaint Electrician will report to Armaan Cell for uploading the completion report.(xii) Contractor shall deploy local electrician for the job so that urgent nature of complaints like no light, short circuit and earth fault will also done on Holidays/ Sunday. |
| 4 | Supply only in replacement switch piano flush type 5 Amps One-way, AC 230V on existing switch board all as specified and as directed. |
| 5 | Supply only in replacement of switch piano flush type 15 Amps single pole one-way, 230V complete all as specified and as directed. |
| 6 | Supply only in replacement switch piano type two ways AC 230 volts 6 Amps as per on existing switch board . |
| 7 | Supply only in replacement socket out let 2-in-1, 3 Pin 6 Amps flush type 230 volts complete all as specified and as directed. |
| 8 | Supply only in replacement socket outlet, flush type, 2-in-1, 3 pins, 6 & 16 Amps multipurpose complete all as specified and as directed. |
| 9 | Supply only in replacement bell push switch piano, flush type, 5 Amps complete all as specified and as directed. |
| 10 | Supply only in replacement batten type angular/ Batten lamp holder insulated body with back plate suitable for batten fitting including PVC round block complete all as specifed and as directed. |
| 11 | Supply only in replacement ceiling fan regulator, electronic socket type, single phase, 230 volts complete all as specified and as directed. |
| 12 | S&F Modular lamp holder with LED retrofit lamp 9 watt suitable for Lamp holder base all as specified and directed. |
| 13 | Supply only in replacement moduler bell push(different color as per site requirement) 6/10 Amp complete all as specified and as directed. |
| 14 | Supply only in replacement of modular switch 6 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed |
| 15 | Supply only in replacement of modular switch 16 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed. |
| 16 | Supply only in replacement of modular socket, 5/6A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed. |
| 17 | Supply only in replacement of modular socket, 15/16A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed . |
| 18 | Supply only in replacement of bell ding-dong 230 volts, single phase complete all as specified and as directed. |
| 19 | Supply only in replacement plug top 3 pin, 5 Amps complete all as specified and as directed. |
| 20 | Supply only in replacement plug top 3 pin, 15 Amps complete all as specified and as directed. |
| 21 | Supply only in replacement Modular ceiling fan regulator, electronic socket type, single phase, 230 volts complete all as specified and as directed. |
| 22 | Supply only in replacement Modular ceiling fan regulator, electronic switch type, single phase, 230 volts complete all as specified and as directed. |
| 23 | Supply only in replacement of capacitor AC 230 volts 0.75 MFD complete all as specified and directed. |
| 24 | Supply only in replacement of capacitor AC 230 volts 2.50 MFD complete all as specified and directed. |
| 25 | Supply only in replacement of capacitor AC 230 volts 3.15 MFD complete all as specified and directed. |
| 26 | Supply only in replacemnt box type PVC rectangular block for mounting switches, sockets, fan regulator etc 4 / 6 way, surface mounting including necessary gitti for fixing complete all as specified and as directed. |
| 27 | Supply only in replacement of frame plate with cover for modular switch 4/6 module including screws and washers etc model/make as per existing in site complete all as specified and as directed. |
| 28 | Supply only in replacement of frame plate with cover for modular switch 8 module including screws and washers etc model/make as per existing in site complete all as specified and as directed. |
| 29 | Supply only in replacement MS housing box 5 / 6 module suitable for modular switch as per existing including taking out old UNSV switch box and making good to the disturb surface by pcc complete all as specified and as directed. |
| 30 | S&F in replacement LED Tube(White/Warm white) rod with polycarbonate diffuser, 4 feet long of capacity 20 watts complete with all accessories base all as specified & directed by Engr-in-Charge. |
| 31 | S&F in replacement LED tube light fitting, 1 x 20W, 230V energy efficient T8, box type made of CRCA sheet heavy duty industrial type housing with reflector cover channel, bipin holders, connector block etc. complete with tube rod LED 20 watt, all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 32 | Supply and fixing LED mirror light(White/Warm white) fitting batten type with high output diffuser, 2 feet, 9/10 watt 230 V AC decorative type including connecting up with twin core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 33 | S&F in replacement LED tube light fitting(White/Warm white),1 x 20W,(Flicker-free), 230V energy efficient slim polycarbonate batten type housing with reflector cover channel, omplete with tube rod LED 20 watt, all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 34 | Supply and fix in replacement of 9W LED Motion sensor lamp It automatically turns on when it detects motion within 15 ft radius and turns off after one minute when no motion is detected. |
| 35 | Supply and fix in replacement of 9W LED Emergency rechargeable self charging inverter light, automatically turns on during power cuts, providing 3-4 hours of illumination using a buit-in Lithium-ion battery. |
| 36 | Supply only in replacement of LED 12 Watt Square shape surface mounted LED Panel down lighter complete all as specified and directed. |
| 37 | Supply only in replacement of 18 watt square recess mounted down lighter separate replaceable electronic driver celling cut out dia as per exising size/round square shaped polycarbonate fixture complete all as specified and directed. |
| 38 | Supply only in replacement LED bulk head light fittings including led lamp 10 watt as per IP65 and making necessary connections complete all as specified. |
| 39 | S&F decorative 9W, LED wall mounting fittings complete set including 9W LED lamp 9W polycarbonate type B-22 complete all as specified and directed. |
| 40 | S&F in-built PIR sensor (36 Watt LED, Size 2x2 feet) indoor type decorative recess mounted direct/ indrect luminaries light fixures (white/warm white as per ground reqmt) aluminium body, opal diffuser, IP20, suitable for false ceiling complete including making connection with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 41 | S&F indoor type decorative recess mounted direct/ indrect luminaries light fixures (white/warm white as per ground reqmt) aluminium body, opal/Prismatic for uniform light \\"Flicker free\\" IP20, suitable for false ceiling complete including making connection with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 42 | S&F in repair indoor type decorative recess mounted direct/ indrect 60cm x 60cm luminaries light fixures 36 watt LED (white/warm white as per ground reqmt) complete including making connection with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 43 | S&F in replacement MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of 'B' series in distribution boards all as specified. |
| 44 | S&F in replacement MCBs single pole and neutral (SPN) 32 Amps with 10 KA breaking capacity of 'B' series in distribution boards all as specified and directed. |
| 45 | S&F in replacement MCBs single pole and neutral (SPN) 40 to 63 Amps with 10 KA breaking capacity of 'B' series in distribution boards all as specified and directed. |
| 46 | Supply only in replacement of single pole and neutral sheet metal enclosures with two pin & earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed. |
| 47 | Supply only in replacement of MCCB 100 amps 4 pole, AC 415 volts 16 KA, four pole including making connections with suitable size of aluminium lugs of any make /model as per existing MCCB Fitted in DB complete all as specified and directed. |
| 48 | MCCB 3 Pole .415 V. fixed type, 25 to 100 Amps with breaking capacity 16 KA |
| 49 | MCCBs 415V,16KA, 4 Pole 63 Amps |
| 50 | Supply only in replacement MS machine screw 25 mm long suitable for fixing bakelite hylam sheets/square blocks complete all as specified and directed. |
| 51 | Supply only in replacement of 3 mm thick hylam sheet of any size including screws and washers etc as per required at site complete all as specified and as directed. |
| 52 | S&F in repacement PVC round fan cover plate of size 15cm to 20cm or as per exiting size complete all as specified and directed. |
| 53 | S&F in repacement casing caping of existing size as per site including laying of electric wire inside, making electric connection and fixing necessary saddle and gitti at regular interval complete all as specified and directed. |
| 54 | Rigid non-metallic PVC conduit (5-20 MM) exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. |
| 55 | Supply only in replacement of single core wire 2.5 Sqmm multi-strand PVC insulated copper conductor FRLSH cable including connections of cable with MCBs or bus bars complete all as specified and directed. |
| 56 | Supply only in replacement of single core wire 1.5 Sqmm multi-strand PVC insulated copper conductor FRLSH cable including connections of cable with MCBs or bus bars complete all as specified and directed. |
| 57 | M&L for point wiring with 1.5 Sqmm multi strand PVC insulated FRLSH copper conductor cable in existing concealed conduit for one light or bell point controlled by one switch including PVC insulated 1.5 sqmm copper conductor continuous earth wire using existing CI/MS sunken box and connecting earth with dolly complete all as specified and directed. ( Note :- Switch, socket measured as separate item) |
| 58 | All as per Srl item No 55.00 here-in-before but for one 5 Amps independent board. |
| 59 | All as per Srl item No 55.00 here-in-before but for one 5 amps socket out but on the same board. |
| 60 | M&L for point wiring with 2.5 sqmm multi strand PVC insulated copper conductor cable FRLSH in existing concealed conduit for one 15 amps socket outlet independent controlled by one switch including PVC insulated 2.5 sqmm copper conductor continuous earth wire connecting earth with dolly complete all as specified and directed. |
| 61 | M&L for sub main wiring with two runs of single core multi stranded PVC insulated, copper conductor, grade 1100 Volt , FRLSH cable of size 6 sqmm including 6 sqmm multistranded copper conductor FRLSH cable PVC insulated for earthing duly connected with earth dolly, with approved colour coding including PVC conduit heavy grade, of appropriate dia. concealed in wall with accessories including cutting chases and making good to the disturbed surfaces as per existing and taking down old unserviceable wiring complete all as specified and directed. (Note :- Three run of cable alongwith PVC conduit together shall be measured as single run). |
| 62 | M&L for sub main wiring with two runs of single core multi stranded PVC insulated, copper conductor, grade 1100 Volt , FRLSH cable of size 4 sqmm including 4 sqmm multistranded copper conductor FRLSH cable PVC insulated for earthing duly connected with earth dolly, with approved colour coding including PVC conduit heavy grade, of appropriate dia. concealed in wall with accessories including cutting chases and making good to the disturbed surfaces as per existing and taking down old unserviceable wiring complete all as specified and directed. (Note :- Three run of cable alongwith PVC conduit together shall be measured as single run). |
| 63 | M&L in replacement for service wire 10 Sqmm 2 core PVC insulated and PVC sheathed 1100 volts grade all as specified and directed. |
| 64 | S&F in replacement of building security LED light luminaire 45 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240,50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens complete all as specified and directed. |
| 65 | S&F in repair GI pipe bracket made out of GI pipe light grade 32 mm bore and bent to shape 1.5m long, MS clamps made out of MS flat iron of size 40mm x 5mm and drilling of hole for and including nuts, bolts and washers, painting MS clamps with two coats of synthetic enemal paint over a coat of red oxide primer including taking down the existing GI pipe bracket complete all as specified and directed. |
| 66 | S&F post top lantern LED Type 20 watt AC Outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. |
| 67 | Supply and fixing LED flood light (Different color all as groung requirement) 50 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. |
| 68 | M&L for taking down the existing faulty single phase tamper proof electronic energy meter with LCD display 230 volts 4 wire system, 10-60 amps, 50 Hz ,replacing the unserviceable chip board, unserviceable body and all burnt parts complete,making it to serviceable state including testing, caliberation & refixing the same complete all as specified and directed by Engr-in-Charge. |
| 69 | S&F in replacement cordless bell of different music complete all as specified and directed. |
| 70 | S&F in repair LED driver suitable for 36 watt 2'x2' panel ceiling fitting complete all as specified and directed. |
| 71 | S&F in repair LED driver suitable for PIR sensor 36 watt 2'x2' panel ceiling fitting complete all as specified and directed. |
| 72 | S&F in repair LED driver suitable for 24 watt 284mm x 284mm panel ceiling fitting complete all as specified and directed. |
| 73 | S&F Dual USB and Type C modular mobile charging socket, 1 Module, 2.4 A 12 Watt A+C USB complete all as specified and direcred. |
| 74 | S&F in replacement of down rod (for ceiling fan) of different size as per requirement 1/2/3/4/5/6 feet |
| 75 | Supply only in replacement bed switch AC 230 Volts 6Amps flush type . |
| 76 | A Schedule of Credit for old/unserviceable demolished/ dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Credit i.e Rs. 86,825/- from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit. Please Enable Macros to View BoQ information |