| 1 | Demolishing roof lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer- in-charge. |
| 2 | Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. |
| 3 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead as per direction of Engineer-in- charge. |
| 4 | Demolishing brick work in lime mortor manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 5 | Demolishing brick work in lime mortor manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 6 | Dismantling roofing including ridges, hips, valleys and gutters etc., andstacking the material within 50 metres lead of: Asbestos Cement sheet |
| 7 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 8 | Laying water bound macadam sub-base with brick aggregate and binding material, earth etc. including screening, sorting and spreading to template and consolidation with light power road-roller etc.complete.(payment for brick aggregate and moorum etc. to be made separately) DSR16.5.1 |
| 9 | Supplying and filling in plinth with sand under floors, including wateringramming, consolidating and dressing complete. |
| 10 | Dry brick on edge flooring in required pattern with old bricks including filling joints with local sand, with common burnt clay non modular bricks. but with old servecable bricks.(Labour rate) |
| 11 | Cleaning mortor from brick in lime mortor brick work.DSR 15.8.2 |
| 12 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge.DSR2.6.1 All kinds of soil complete. |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering-All work up to plinth level 1:5:10 (1 cement: 5 approved coarse sand : 10 graded stone aggregate 40 mmnominal size) DSR 4.1.10 |
| 14 | Brick work with common burnt clay (non modular) bricks of Class-150 in foundation and plinth in cement mortar 1:4(1 cement :4 coarse sand . (SI 6.1.1) |
| 15 | Reinforced cement concrete work in beams,suspended floors,roofs having slope up to 15\\" ,landings, balconies, shelves ,chajjas,lintals, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding the cost of centring and shuttering,finishing and reinforcement with 1:1.5:3 (1 cement:1.5 approved coarse sand :3 graded brick aggregate 20 mmnominal size) SI 5.3 |
| 16 | Centring and shuttering including shuttering, proping etc and removal of Lintals, beams,plinth beams, girders,bressumers and cantilevers with water proof ply 12 mm thickDSR 5.9.21 |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete .DSR 5.22.1 Mild steel and Medium Tensile steel bars |
| 18 | 12 mm thick dado plaster in 1:3 cement& coarse sand mortor finished with a floating coat of neat cement of mix DSR 13.7.1 |
| 19 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 dsr 11.4 |
| 20 | Supply of 2.0 HP single phase STP M22 2 H.P. crompton/ approved make mud pump FOR at gorakhpur bus station complete. |
| 21 | Supply of water delivery pipes 4'' inch dia white colour of kisan or approved make complete. |
| 22 | Supply of 10 sqmm unarmoured 2 core pvc insulated weather proof 1100 v grade aluminium conductor cable(poly cabe) etc all complete. Please Enable Macros to View BoQ information |