| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 2 | All kinds of soil |
| 3 | Earth work in rough excavation, banking excavated earth in layers not exceeding 20 cm in depth, breaking clods watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m : |
| 4 | All kinds of soil |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 7 | -All work upto plinth level: |
| 8 | 1:5:10 ( 1 Cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 9 | Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in |
| 10 | Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 11 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 12 | Double charge vitrified tile polished finish of size |
| 13 | Size of Tile 600 x 600 mm |
| 14 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 15 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 16 | W.C. pan with ISI marked white solid plastic seat and lid. |
| 17 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 18 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : |
| 19 | Local best quality Teak wood |
| 20 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. |
| 21 | Local best quality Teak wood |
| 22 | 35 mm thick shutters |
| 23 | Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete : |
| 24 | 100 mm |
| 25 | Providing and fixing ISI marked oxidised M.S.sliding door bolts with screws etc. complete |
| 26 | 250x16 mm |
| 27 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) |
| 28 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 29 | 100x10 mm |
| 30 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 31 | Internal work - Exposed on wall |
| 32 | 25 mm nominal outer dia Pipes |
| 33 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 34 | ProvidingandfixingUPVCsoil,waste,rainwaterandventpipes includingall requisite fittings, jointingof pipes&fittingswithsolventcement, trenching, refilling&testingof joints complete as per direction of Engineer in charge |
| 35 | 110 mm |
| 36 | 75 mm |
| 37 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 38 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications : |
| 39 | Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm. |
| 40 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 41 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 42 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge. |
| 43 | In Cement mortar |
| 44 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 45 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 46 | G.S. Sheet |
| 47 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 48 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 49 | With float glass panes of 5.50 mm thickness |
| 50 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: |
| 51 | Two or more coats on new work |
| 52 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 53 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- |
| 54 | (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass |
| 55 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 56 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 57 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 58 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : |
| 59 | With cement mortar 1:4 (1 cement: 4 coarse sand) |
| 60 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 61 | 15 mm nominal bore |
| 62 | Wiring Item |
| 63 | Wiring for light point / Fan point/ Exhaust Fan ponit / Call bell point with 1.5mm2 PVC insulated copper conductor single core cable in pvc casing and capping with piano type switch, phenolic laminated sheet suitable size M.S. Box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc. as reqd. |
| 64 | Group C |
| 65 | 1. Light point |
| 66 | 2. Ceiling fan pt. |
| 67 | 3. wall fan pt. |
| 68 | 4. Exhaust fan pt. |
| 69 | Wiring for circuit / sub- main wiring along with earth wire with ( the following sizes of ) PVC insulated copper conductor single core cable in PVC casing and capping etc as reqd. |
| 70 | 2. 2x2.5mm2 + 1x2.5mm2 earth wire |
| 71 | 3. 2x4mm2 + 1x4mm2 earth wire |
| 72 | 4. 2x6mm2 + 1x6mm2 earth wire |
| 73 | FITTING ITEMS |
| 74 | S/F suitable size G.I box with modular plate and cover in front on surface or in recess i/c P/F 3 pin 5/6 amp modular socket outlet 5/6 amp modular switch , connection painting etc as reqd. ( for light plugs to use in non-residential building). |
| 75 | S/F suitable size G.I box with modular plate and cover in front on surface or in recess i/c P/F 6 pin 15/16 and 15/16 amp modular socket outlet 15/16 amp modular switch , connection painting etc as reqd. |
| 76 | 76.2mmX76.2mm conical round plate |
| 77 | S/F 3 pin 5 amp ceiling rose on the existing junction box /wooden block i/c connection etc as reqd |
| 78 | S/Fbrass batten /angle holder i/c conection etc as reqd. |
| 79 | Supplying & fixing stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc as reqd. |
| 80 | S/F 48'' Sweep (1200mm) A.C ceilling fan complete with down rod canopy, 3 (three) blades but without regulator etc as reqd.( Make Bajaj/Usha or simillar) |
| 81 | S/F 305mm sweep exhaust fan complete with all accessories i/c connection etc as reqd. |
| 82 | S/F 450 mm dia wall mounting Fan complete with all accessories etc. as reqd. |
| 83 | Supplying and fixing 5 amp to 32amp rating 230 V 'B' series MCB for lighting and other load of ( following poles ) in the existing MCB DB complete with connection testing and commissioning etc as reqd. |
| 84 | 1. Single pole |
| 85 | S/F( following rating) double pole 240v isolator in the existing MCB DB complete with connection ,testing and commissioning as reqd. |
| 86 | 1. 40 amp |
| 87 | 2. 63 amp |
| 88 | S/F 18 w LED Please Enable Macros to View BoQ information |