| 1 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. DSR 2.6.1 |
| 2 | Providing and laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. DSR 4.1.10 |
| 3 | Supplying and filling in plinth with sand under floors, including watering ramming, consolidating and dressing complete. DSR 2.27 |
| 4 | Class M-150 brick work in 1:4 cement coarse sand (of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands,plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : of lintal, beam, plinth beams girders and cantilevers with water proof ply 12mm thick DSR 5.9.21 |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : of lintal, of suspended floors, roofs, landings, balconies and access with water proof ply 12mm thick DSR 5.9.20 |
| 9 | Steel reinforcement work for RCC work including straightening, cutting bending placing in position and binding all complete. DSR 5.22.1 mild steel and medium tensile steel. |
| 10 | Brick work with common burnt clay (non modular) bricks of designation 7.5 in super structre above plinnth level up to floor V level in cement mortar 1:4 (1 cement :4 coarse sand . (SI 6.4.1) |
| 11 | 12 mm. cement plaster of mix 1:4 (1 cement :4 coarse sand) (SI 13.4.1) |
| 12 | 12 mm cement plaster finished with a floating coat of neat cement of mix DSR 13.7.1 ,1:3 (1 cement : 3 coarse sand) |
| 13 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 dsr 11.4 |
| 14 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR 2018 13.80 |
| 15 | Finishing walls with Acrylic Smooth exterior paint of required shade New work Two coat applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm i/c all material, labour, T & P etc complete for proper completion of work. 13.47.1 |
| 16 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 17 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. 16.83 |
| 18 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineerin-charge. |
| 19 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. DSR 10.25.1 In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 20 | Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x 60 cm of mix 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size), every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50 cm of the same mix, provided with welded steel wire fabricfixed between the posts fitted and fixed with G.I. staples on wooden plugs or tied to 6 mm bar nibs with G.I. binding wire (cost of posts,welded steel wire fabric, painting, earth work in excavation and concrete to be paid for separately). |
| 21 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding. |
| 22 | Providing and fixing 1mm thick M.S. sheet doors with frame of 40x40x6mm angle iron and 3mm M.S. gusset plate at rhe junctions and corners, all necessary fittingscomplete, including applying apriming coat of approved steel primer 10>5.1 Using M.S. angles 40x40x6mm for digonal braces. |
| 23 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :13.62.1 Two or more coats on new work |
| 24 | W/P for light with 1.50 sqmm. FR PVC insulated multistrand single core copper conductor cable in PVC conduit pipe on surface complete with 1.5 Sqmm FR PVC insulated multistrand single core copper conductor cable as earth wire drawn in side the conduit, 121C |
| 25 | W/P for fan/Fresh Air Fan with 1.50 sqmm. FR PVC insulated multistrand single core copper conductor cable in PVC conduit pipe on surface complete with 1.5 Sqmm FR PVC insulated multistrand single core copper conductor cable as earth wire drawn in side PWD 123 C |
| 26 | S/F of 40 Amp DP isolator (10 KA) Cat A1005 A |
| 27 | S/F of factory wired, LED Tubelight 1x22 watt & without end covers for 1 no 22 watt LED lamp complete in all respect.SI1413 |
| 28 | Supply of AC 230/250 volts, 50 HZ ceiling fan with standard down rod, blades, 2 nos. caps etc. complete (Make : Bajaj / Crompton / Havells)1200 mm sweep |
| 29 | Supply & fixing of electronic Fan dimmer, 300/400 watt, ISI marked, on the existing switch board including making connections, required material, labour T/P etc. for proper completion of work to the satisfaction of Engineer of work. |
| 30 | S/F of LED street light fitting having die cast aluminium body and diffuser with driyer set Suitable for 75 to 90 watt. Confirming to IP 65 Protection complete in all respect. (S.I. No. 1423) Cat AA |
| 31 | W/P for H.P.M.V./Sodium Vapour with 1.5 sqmm. FR PVC insulated multistrand single core copper conductor cable in PVC conduit pipe on surface complete with 1.5 Sqmm FR PVC insulated multistrand single core copper conductor cable as earth wire drawn in side complete. S.I. 153(C) |
| 32 | S/F of heavy duty AC 230/250 volts, 50 HZ 450 mm dia heay duty exhaust fan with standard down rod, blades, 2 nos. caps etc. complete (Make : Bajaj / Crompton / Havells) |
| 33 | Erection and testing of ceiling fan/exhaust and regulator etc excluding supply of down rod, complete in all respect. |
| 34 | Supply & burrying of 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnel for watering and one earthing lead of no. 8 SWG G.I. wire in 15 mm dia. GI pipe upto switch board (from apron to switch board the cost of GI pipe & GI wire will be extra) 300mm square C.I. box with hinged cover, masonary housing alternate layer of charcoal/ coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect. S.I. no 703 |
| 35 | Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects. |
| 36 | S/F of hexagonal fan box with hexagonal side of approx. 80 mm.in length fabricated from 16 SWG M.S. sheet incorporating with 10 mm. dia. M.S. round bar duly bent for supporting fan hanger duly painted with red oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour, T&P etc. for proper completion of work. S. I. no 1149 |
| 37 | SUB STATION WORKSH.T. SYSTEM11 KV DOUBBLE POLE STRUCTURESupply, erection, testing and commissioning of 2 pole structure for providing 1 No. 11KV,400A GOS in accordance with IE rules, & local authority specification and drawings and comprising of the following.a. 2 Nos. 11 mtr. long MS STEEL poles complete with, pole excavation, MS STEEL foundation, and back filling complete MS steel channel/angle iron etc.b. 1 Set of cross arms, branching, clamps and painting complete with GI nut,bolts & washers as required (for GO & DO), LA connection.c 1 set 11KV Insulator complete with spindles & hardware & DOG 11KV ACSR conductors complete as required.d .1 No. 11KV 400A TP Gang operated Air break switches complete with 25mm dia GI pipe operating machanism, handle & locking arrangement.e. 1 set of 3 nos.11KV single pole drop out fuse complete with barrel fuses,and mounting arrangement.f. 1 set (3 nos.) 11KV lightning arrestor and connecting to all phases.g. 1 No. 150 mm dia GI pipe class 'B' (for XLPE cable protection) as required.h. 2 Set 50mm dia 3m long GI pipe earting with 25 x 6 mm GI earth strip complete as required (for GO & DO & LA).i 1 nos. 11KV HT danger boards and 2 set of anticlimbing devices.11 KV Double Pole Structure |
| 38 | OUTDOOR TYPE HT PanelThree Way, 11kV, 800Amps 21kA for 3 sec., SF6 insulated Non-Extensible Compact switchgear (Type CCT2 ) consisting of Two Nos. Fixed Isolators & One No. Fixed Vacuum Circuit Breaker in SF6 insulated Stainless steel enclosure with self-powered series trip microprocessor base numerical over current & earth fault relay (IDMTL+Inst.) for protection (AS Per SLD)B. OUTGOINGS :1 No. VCB each having following1 No. 630A, 11kV, 3 Phase, 50Hz., metal clad, dead front, 350 MVA rupturing capacity, Fully Drawout type, Vacuum Circuit Breaker (VCB)1 set of 11kV/110V Potential Transformers with HRC fuses1 Set of Phase indicating lamps with HRC fuses1 No. 0-15 kV Digital voltmeter with selector switch1 set of indicating lamps to indicate OPEN, CLOSE, TRIP,SPRING CHARGED, TRIP CIRCUIT HEALTHYPush button for ON, OFF,TRIP&TRIP circuit healthy1 set of 100/5-5A Current Transformer for metering and protectionDigital Multifunction meter (KVA,KWh,P.F ,Amp.,Voltage)(a) 3 Over Current + 1 Earthing fault (50/51/50N/51N ) + Over voltage (59) + Under voltage (27) and master trip relay. (b) Lockout relay, supervisionary trip relay.AccessariesTNC Switch Panel space HeaterPush button trip circuit healthy cheakPanel illumination lamp with switch.3 pin plug with socket of 15Amp.Local/Remote switch8 window Aunnciation with hooterEmergency Trip ButtonMCB for AC & DCBUSBARS :11kV, 350 MVA, 630 Amps Three Phase busbars of copperH.T. Panel described as above RMU |
| 39 | HT SWITCH GEARThree Way, 11kV, 630Amps 21kA for 3 sec., SF6 insulated Non-Extensible Compact switchgear (Type CCT2 ) consisting of Two Nos. Fixed Isolators & One No. Fixed Vacuum Circuit Breaker in SF6 insulated Stainless steel enclosure with self-powered series trip microprocessor base numerical over current & earth fault relay (IDMTL+Inst.) for protection\\"RMU-NON-Extensible FBX-C /CCT2(2 isolators (C), 1 Vacuum circuit breaker (T2) with AL Busbar)-BIL 28/75kVC FUNCTION Type:- 3 position Disconnector and Earthing switch equipped with separate drive unit.1. Operation of LBS- Manual2. Cable Switch Rating- 12KV, 630A, 21/3sec.3. Cable Bushing Rating- 630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication-6. ON/OFF/Earth indication on the front mimic of the panel.7. Bottom Cable Termination- Suitable upto 3 No 1C X 240sqmm Cu,8. Cable Entry-Bottom,FrontT2 FUNCTION Type:- 3 position Disconnector and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV,630 A, 21/4sec.2. Operation of breaker – Manual3. Self Powered Electronic numerical protection relay providing over-current & earthfault protection –C&S make CSDPR/SEIL Make DPX-V54. Tape Wound protection current transformers (Details During Detailed Engineering)5. Capacitive voltage indication fixed type.6. ON, OFF, EARTH indication on the front mimic of the panel.7. Cable box for termination of cable8. Cable cover standard.9. Emergency trip push button.10. Shunt trip Coil - 230VAC\\"RMU AccessoriesOperating Handle - 1 No.Manometer for SF6 gas pressure indication.Right Angled Cable Boots suitable for 3 Run x 1 C x 240 Sq mm |
| 40 | TRANSFORMER (Manufactured as per IS -1180 Level-2)TYPE:- ONAN, Hermatically sealed corrugated tank (WITH VEGETABLE TRF OIL)1. Ratio- 11 KV/433V,2. Capacity:- 1250 KVA,3. Vector Group- DYn11,4. Off Load Tappings +5% to -10% in steps of 2.5%,5. Winding- Double Wound Copper,6. Class of Insulation- A,7. Ambient Temperature- 50 Deg C,8. Temperature rise in oil over ambient- 40 Deg C9. Temperature rise in winding over ambient- 50 Deg C9. Load Losses- 980 Watts Max (@ 50% loading),10. Full Load Losses- 2930 Watts Max (@ 100% loading),11. %Impedance- 4.5 % (IS Tolerance)\\"Transformer AccessoriesOil Temperature Indicator |
| 41 | MAIN LT PANELIncomer 2000 A, ACB, 4 Poles, Fixed Manual, 50 KA, Motorised based release for O/C,S/C,ST, UV & E/F Protection On, OFF, TRIP lamps -R/Y/B indicating lamps- MFM 2000/5A,CL0.2,2.5VAOutgoing400 Amp. 35KA TPN MCCB 5 No.INSTRUMENTS1 set of multifunction of meter with RS 485 port.1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).1 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).1 Sets auto trip indicating lamp .Energy meter is supplied seperately cost of the meter as approved in department.3 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).3 Sets auto trip indicating lamp .Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams.RELAYS AS PER SLD |
| 42 | Earthing G.I. Earth plate Electrode: Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 43 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but with charcoal/ coke and salt ) as required |
| 44 | Earthing with G.I. pipe 4.5m long, 40mm dia including all accessories and providing mesonry encloser with cover plate having locking arrengement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 45 | Supply and laying of 6SWG GI earth wire at 0.50m below ground level for conductor earth electrode, including connection/termination with GI themble as required. |
| 46 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 47 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 48 | CABLE & END TERMINATIONSSupply of 3 core standered aluminium conductor XLPE insulated PVC bedded, Galvanised flat steel strip armound cables confirming to IS 7098 II KV grade 3 Core 240 sq.mm |
| 49 | Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :240sq. mm |
| 50 | SAFETY EQUIPMENTSSupplying and Fixing of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge. |
| 51 | Supplying & Laying of 1800 mm x 900 mm X 12 mm thick chequered rubber matting of tested quality |
| 52 | Supply and fixing danger board fabricated from 10 gauge MS sheet as per IE Rules |
| 53 | S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T & P for proper completion of work. |
| 54 | Supply and fixing of fire extinguishers, ABC Type 4.00 kg. capacity(ISI Marked IS : 15683 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 55 | Supply and fixing of CO2 type fire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work. Please Enable Macros to View BoQ information |