| 1 | Part-A (Internal Electrification) |
| 2 | Wiring for Light point/Exhaust point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/ Finolex/ Anchor/ Salzer/ Havells/ Apar/ Grandlay/ eq. make to be approved by EIC) in surface/ recessed Conduits (Including Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/ ABB / eq. Antibacterical make & shall be approved before execution of work. |
| 3 | Supplying and Fixing of Indicator as required, ISO/IEC Certified Havells(Crab-Tree)/Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/ABB / eq. make Antibacterical & shall be approved before execution of work. |
| 4 | Wiring for Fan point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/ Finolex/ Salzer/ Anchor/ Havells/Grandlay/ Apar/ eq. make to be approved by EIC) in surface/recessed Conduits (Including Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/ABB / eq. Antibacterical Make & shall be approved before execution of work. |
| 5 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Havells(Crab-Tree)/ Legrand(Myris)/ Anchor Rooma Plus/ Schneider(Zencelo)/ABB/ eq. Antibacterical Make & shall be approved before execution of work. |
| 6 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (incl cost of conduits) (Polycab/Finolex/Anchor/Salzer/Havells/ Apar/ Grandlay / eq. make to be approved by EIC) |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work.(Including Inverter Input/Output) |
| 8 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (incl. cost of conduits) (Polycab/Finolex/Salzer/Paraflex / eq. make to be approved by EIC) |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells(Crab-Tree)/Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/ABB/ eq. Antibacterical Make & shall be approved before execution of work. |
| 10 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H/HFFR PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (incl. cost of conduits) (Polycab/ Anchor/ Finolex/ Salzer/Havells / eq. make) & shall be approved before execution of work. |
| 11 | 2x10 sq.mm+ 1x6 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards. |
| 12 | 2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/Inverter/AC Point Sub main in One run from Main Panel to Distribution Boards. |
| 13 | 2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Lighting/Inverter Circuit in One run from switch boards to Distribution Boards. |
| 14 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Havells(Crab-Tree)/ Legrand(Myris)/ Anchor Rooma Plus/ Schneider(Zencelo)/ ABB/ eq. Antibacterical Make & shall be approved before execution of work. |
| 15 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/ Siemens/ Legrand/ ABB /Schneider / eq. make to be approved by EIC) |
| 16 | Supply/Fixing/Testing and Commissioning of Supplying and fixing following rating, double pole,(single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (L&T/Siemens /Legrand/ABB/Schneider/BCH / eq. make to be approved by EIC) |
| 17 | 25-32Amp. |
| 18 | 40Amp. |
| 19 | 63Amp. |
| 20 | Supplying and Fixing of MCB 6-way horizontal typed , sheet steel, Double Door Distribution Board, SPN 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider/BCH / eq. make to be approved by EIC) |
| 21 | Supplying and Fixing of MCB 6-Way (4+18) horizontal typed , sheet steel, Double Door Distribution Board, TPN 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider/BCH / eq. make to be approved by EIC) |
| 22 | ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job. |
| 23 | Supply/Installation/Testing and Commissioning of 18W + LED Surface/Recess Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 120 lm/W with Pressure Die cast Aluminium body & Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Wipro/Bajaj/Jaquar/LT/Crompton/Surya/Equivalent Make to be approved by EIC |
| 24 | Supply/Installation/Testing and Commissioning of 22-24 watt ultra slim LED surface mounted lighting panels(300mm x 300mm) having CRCA Body (Commercial type), minimum lumens 100 lm/w ,the luminaire housing should be crca /aluminium and the luminair optics shall have a high efficency with transmittance ,average life of 50000 hrs operating temperature -10 C to + 45 C. The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Wipro/Jaquar/Bajaj/Surya/Equivalent Make |
| 25 | Supply/Installation/Testing and Commissioning of 36-40 watt ultra slim LED surface mounted lighting panels (600 mm x 600mm Square) having CRCA Body (Commercial type) ,minimum lumens 100 lm/w ,the luminaire housing should be crca /aluminium and the luminair optics shall have a high efficency with transmittance ,average life of 50000 hrs operating temperature -10 C to + 45 C.The Fixture should have In-built Surge Protection of 2kV,440V Protection. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/ Wipro/ Jaquar/ Bajaj/ Surya/ Equivalent Make to be approved by EIC |
| 26 | Providing & Fixing of IK08 IP-66 protected high power LED 100 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Philips/Wipro/Bajaj/Jaquar/LT/Crompton/Surya/Equivalent Make. as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. |
| 27 | Supply/Installation/Testing and Commissioning of upto 400mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB o including connection etc USHA/Anchor/Polycab/Havells/Orient/Crompton / eq. make to be approved by EIC.. |
| 28 | Supply/Installation/Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified. |
| 29 | Supply/Installation/Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G,acetylene and electrical fires. |
| 30 | Supply/Laying of 25/32mm Dia PVC Conduit of Anchor/ Ravinder/ Polypack/ Finolex / eq. make to be approved by EIC. with other accessories like bends,etc complete. |
| 31 | Supply and Fixing of Modular 25-32Amp industrial Socket outlet having fitted with 25-3232 Amps DP MCB and Top with Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo) / eq. make to be approved by EIC for AC Points. |
| 32 | Supply and Fixing of single pole blanking plates on existing MCB boxes, excluding cost of Boxes. |
| 33 | Providing and fixing of bakelite hylam sheets of required size including cutting, filing with S/F screws etc. |
| 34 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required of Legrand/ Panasonic/ Anchor/ Schneider / eq. make to be approved by EIC. |
| 35 | Supply/installation/testing and commissioning of CPRI-approved panel Wall/floor-mounted compartmentalized, 415 volts TPN MCCB Main Distribution panels, fabricated out of sheet steel of 16 gauge dust-protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel.The Panel is to be provided and fitted with the following adjustable-type controlling/protection switchgear devices:1. Normal Incoming:200 Amp TPN MCCB with breaking capacity of 36 KA with extended thimbles of Legrand/Siemens/ABB//LK make = 1 No.,200 Amp Bus bar Al Strips(3+1) = 1 Set,Digital Voltmeter =1 No., Digital Ammeter = 1 No., CT coils for Ammeter 300 / 5A = 1 set, phase indicators =1 set2. Generator Incomer:100 Amp Four Pole Change over Switch of Legrand/Siemens/ABB//LK make = 1 No., 100 Amp Bus bar Al Strips(3+1) = 1 Set, Digital Voltmeter =1 No., Digital Ammeter = 1 No., CT coils for Ammeter 300 / 5A = 1 set, phase indicators =1 set3. Bypass Switch:100 Amp 4-Pole Bypass Switch for bypassing 15 KVA AVROutgoing:(1) 63 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T / eq. make to be approved by EIC. = 08 No for normal heating sub main(2) 40 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T / eq. make to be approved by EIC. = 08 No for Sub main lighting(3) 32 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T / eq. make to be approved by EIC. = 08 No for Sub main invertorThe Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to be approved by Engineer Incharge before manufacturing. |
| 36 | Supply/Installation/Testing & Commissioning of 1-phase 15 KVA,50 Hz Oil cooled unbalanced type Voltage Stabilizer SERVO control of Approved brand COPPER wound of AE/Chinar/Cosco / eq. make to be approved by EIC. ISI/1SO/IEC certified for smooth functioning/constant voltage supply having Technical Specifications :Input voltage(Ph-Ph) ranging from 90 Volts to 240 Volts and a balanced output Voltage of 230 Volts, ±2% Buck Boost Transformer Copper wound 99.9% ,OIL Immersed COOLING OIL, High cut/Low Cut /Time delay/Over Cut through Micro Controller and Spike Protection. |
| 37 | Providing and Laying of shock proof rubber mats of 2mx1mx12mm thick in size of Standard Make. |
| 38 | Supply/Laying/Testing and Commissioning of 3.5-Core 70 mm sq. Al armored XLPE Insulated,PVC cable Havells/Polycab/RR Kabel/Paramount/KEI / eq. make to be approved by EIC.. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation where required and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping. Please Enable Macros to View BoQ information |