| 1 | Description of works |
| 2 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. |
| 3 | Provision for retrofitting to old RCC members with filling of micro concrete and 10 mm aggregate including leakproof shuttering including cost of hire charges of all machineries cost of all tools and all labour charges etc. complte as per directions and approval of Engineer-in-charge. |
| 4 | Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. Complete as directed by site incharge. |
| 5 | Providing and constructing masonry in precast solid Concrete Block (Grade D - 50 As per I.S. 2185, Part-I, 1974, Reframed 1987 )having compressive strength 5-00 N / mm2) of size (300 mm x 200 mm x 150 mm)in cement mortar 1:6 for superstructure including striking joints on unexposed faces, racking out joints on exposed faces, watering, curing and scaffolding etc. Complete as directed by site incharge. |
| 6 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. (For Gable Roof with truss) etc. Complete as directed by site incharge. |
| 7 | Providing and fixing puf roofing panel sheet of 60 mm thickness for roofing including all fitting and fixing charges as per drawing etc. Complete as directed by site incharge. |
| 8 | Providing G.I. Precoated Ridge Sheet with 80 cm overall width etc. Complete as directed by site incharge. |
| 9 | Providing internal / external 20 mm thick Ready Mix plaster confirming to IS:4031(Part-4) 1988 and IS 383-1970 in a single coat using Cement mortar of proportion 1:4 containing special type of polymer additives about 0.4%, to all type of surfaces in all positions including scaffolding and curing etc. Complete as directed by site incharge. |
| 10 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. Complete as directed by site incharge. |
| 11 | Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand ,paint should decomposes organic substance sand inorganic gases (NOx, VOC’s ,CO, SOx, form aldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide .and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal /Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent .Warranty Should be given by the Manufacturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise on site technical reports from the concerned company technologist etc. Complete as directed by site incharge. |
| 12 | Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc. Complete as directed by site incharge. |
| 13 | Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45% or 65 to 70 % by roller. (With prior approval of S.E.) etc. Complete as directed by site incharge. |
| 14 | Removing old paint from steel and other metal surfaces and making the surfaces even with hand scrapping, scaffolding etc. Complete as directed by site incharge. |
| 15 | Providing and applying priming coat over new/old steel and other metal surfaces including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steel wool, scrappers and sand paper, scaffolding etc. Complete as directed by site incharge. |
| 16 | Providing and applying two coats of flat oil pain to of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat) etc. Complete as directed by site incharge. |
| 17 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handle etc. Complete as directed by site incharge. |
| 18 | Providing and fixing in position aluminium openable window of any size as per detailed drawing and as directed by Engineer in charge with all necessary aluminum sections including necessary fixtures and fastening with 5 mm thick clear float glass etc. complete. a) With colour anodizing Note While arriving at the rate of item of item weight at 6.90 Kilogram/ One Square Metre is considered etc. Complete as directed by site incharge. |
| 19 | Providing and fixing in position powder coated aluminium louvered windows/ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type,5 mm thick sheet glass louvers, of approved quality etc. Complete as directed by site incharge. |
| 20 | Providing and fixing fly proof mesh shutter toventilator / window using CCTW members of size 45 x 22 mm for frame work and 35 x 22 mm for middle support and fixing fly proof mesh on it and covering TW battens of size 20 x 10 mm including priming and two coats of oil painting to the new wood and steel work and all labour charges including all fixture and fastenings etc. Complete as directed by site incharge. |
| 21 | Providing and applying Varnish in two coats on onld & new wood work including knotting, preparing the surface, scaffolding etc. Complete as directed by site incharge. |
| 22 | Providing and Laying factory made coloured chamfered edge Cement concrete grass paver blocks of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine fine aggregate (natural sand/crushed sand VSI grade finely washed etc.), compacting and proper embedding/laying of inter locking paver blocks into the fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and cutting of paver blocks as per required size and pattern, finishing and sweeping extra fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and complete as per manufacturer specifications & direction of Engineer-in-Charge. 60mm thick CC paver block of M-35 grade concrete with approved colour and design & pattern etc. Complete as directed by site incharge. |
| 23 | Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work). |
| 24 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. Complete as directed by site incharge. |
| 25 | Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S.for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. Complete as directed by site incharge. |
| 26 | Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group DII-A)and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float,filling joint with white/colourcement slurry cleaning curing etc. Complete as directed by site incharge. |
| 27 | Providing and fixing Modular falseceiling of 600 x 600 mm center to center and 13 mm thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended falseceiling consisting of alluminium T2” x 1½” (50 mm x 40 mm)weighing 0.39 Kilogram / mat 60 cm scenter center and fixed with ½” x ½”(15 x 15 mm) flanges weighing 0.19 Kilogram / msuspended on 6 mm dia mild steel rod weighing 0.22 Kilogram /m, fixed on wall and beams including rounding of the edges with alluinium To f2” x 1½” (50 mm x 40 mm)weighing 0.39 Kilogram / m etc.(allalluminium sections shall be anodized) including all labour, material, lifts etc. Complete as directed by site incharge. |
| 28 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all etc. Complete as directed by site incharge. |
| 29 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bedcon-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc.carefully and throwingout the refusal outside etc. complete as per directions and approval of Engineer-in-charge. |
| 30 | Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc. Complete as directed by site incharge. |
| 31 | Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall without flushing cistern with flush cock and necessary fittings including cutting and making good to the walls and floors testing etc. complete.( prior approval of sample and brand by Ex. Engineer is necessary before use) etc. Complete as directed by site incharge. |
| 32 | Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. Complete as directed by site incharge. |
| 33 | Providing and fixing in position U.P.V.C. (Unplasticized PolyVinyl Chloride) having multi-chambered outer frame section (73x50) mm with an outerwall thickness of 2mm & steel reinforcement, multi-chambered slider frame (73x60)mm with steel reinforcement, multi-chambered sliders ash (46x82)mm with steel reinforcement designed to give optimum strength, 5mm thick toughened double glass with 12 mm spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets, silicon sealent, sliding handle, fixture and fastenings (couplings ,hinges) including with all required screw sand nuts with all necessary U.P.V.C sections as per the detailed drawing and as directed by Engineer-In- Charge etc. complete. |
| 34 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. Complete as directed by site incharge. |
| 35 | Providing and fixing 15 mm thick eco-friendly densified edge calcium silicate false ceiling of approved texture of size 595mm x 595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at @12 gm/sq.m including both sides) consisting of main T runner suitably spaced at joints to get required length and size 24X38mm. made from 0.33mm thick(minimum ) sheet, spaced 1200mm center to center and cross T of size 24X28mm made of 0.33mm thick(minimum ) sheet to be interlocked at the middle of the 1200x600 mm panel to form the grid of size 600x600mm resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24x24x3000 made of 0.4 mm thick (minimum) sheet with the help of all plugs at 450mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa) in the grid, including light fittings , fixtures , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling using 12.5mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along main T bottom exposed with 24mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings etc. complete.(currently this item should be used only for VIP cabins) etc. Complete as directed by site incharge. |
| 36 | Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge). |
| 37 | Full Height Partitions in Glass finish - Providing and Fixing 80mm to 85mm thick Full height Double Skin partition up to 3 mtr height with All visible sections in Anodized / Powdercoated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post made up of Aluminium Extruded and Tiles in 5mm thk. Non Toughened Glass on both side. With all the Joints in the partitions covered with PVC extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates. as per design and drawing etc. Complete as directed by site incharge. |
| 38 | Provision made for electrification of (Custom Branch New office) including material, labour charges and all lead & lift charges of electric material etc. Complete as directed by site incharge. |
| 39 | LED Light Power Point (5 Amp) |
| 40 | Fan Point Power (5 Amp) |
| 41 | Table Point Power (5 Amp) |
| 42 | Main Board Power Point (5 Amp) |
| 43 | AC Power Point (16 Amp) |
| 44 | Bathroom Light Power Point (5 Amp) |
| 45 | Bathroom Exhaust Fan Power Point (5 Amp) |
| 46 | Bathroom Geyser Power Point (16 Amp) |
| 47 | 12 W LED Celling light |
| 48 | GST 18% of SL.No.1 to 46 Please Enable Macros to View BoQ information |